2900582

2900582

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

  • 数据手册
  • 价格&库存
2900582 数据手册
https://www.phoenixcontact.com/us/products/2900582 Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-0,6 - 2900582 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and screw connection. Product Features ■ ■ ■ ■ ■ ■ 22.5 mm wide Safety level according to IEC 61508-1: SIL 3, ISO 13849: PL e Reduction in wiring Long service life Space saving 3-phase loop bridges Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 300.0 g Custom tariff number 85371099 Country of origin Germany Technical data Dimensions Width 22.5 mm Height 99 mm Depth 114.5 mm Ambient conditions Ambient temperature (operation) -25 °C ... 70 °C (observe derating) Ambient temperature (storage/transport) -40 °C ... 80 °C Degree of protection IP20 04/05/2016   Page 1 / 8 https://www.phoenixcontact.com/us/products/2900582 Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-0,6 - 2900582 Technical data Device supply Rated control circuit supply voltage US 24 V DC Control supply voltage range 19.2 V DC ... 30 V DC Rated control supply current IS 40 mA Protective circuit Reverse polarity protection Parallel polarity protection diode Surge protection Input data Input name Control input right/left Rated actuating voltage UC 24 V DC Voltage range 19.2 V DC ... 30 V DC Rated actuating current IC 5 mA Switching threshold 9.6 V (“0” signal) 19.2 V (“1” signal) Switching level < 5 V DC (For EMERGENCY STOP) Protective circuit Reverse polarity protection Typical turn-off time < 30 ms Output data load output Output name AC output Rated operating voltage Ue 500 V AC Operating voltage range 42 V AC ... 550 V AC Load current range 75 mA ... 600 mA (see to derating) Trigger characteristic in acc. with IEC 60947 Class 10A Cooling time 20 min. (for auto reset) Rated operating current at AC-51 0.6 A Rated operating current at AC-53a 0.6 A Leakage current 0 mA Protective circuit Surge protection Varistor Output data reply output Output name Acknowledge output Note Confirmation: floating change-over contact, signal contact Contact type 1 PDT Switching capacity according to IEC 60947-5-1 3 A (230 V, AC15) 2 A (24 V, DC13) General Switching frequency ≤ 2 Hz (Load-dependent) Mounting position vertical (horizontal DIN rail, motor output below) 04/05/2016   Page 2 / 8 https://www.phoenixcontact.com/us/products/2900582 Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-0,6 - 2900582 Technical data General Assembly instructions alignable, for spacing see derating Operating mode 100% operating factor Maximum power dissipation 2.5 W Minimum power dissipation 0.88 W Operating voltage display Green LED Status display Yellow LED Indication Red LED Connection data, input side Connection name Control circuits Connection method Screw connection Stripping length 8 mm Screw thread M3 Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 Torque 0.5 Nm ... 0.6 Nm Connection data, output side Connection name Load circuit Connection method Screw connection Stripping length 8 mm Screw thread M3 Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 Torque 0.5 Nm ... 0.6 Nm Standards/regulations Designation Standards/regulations Standards/regulations IEC 60947-1 EN 60947-4-2 IEC 61508 ISO 13849 Insulation characteristics Rated insulation voltage 500 V Rated surge voltage 6 kV Overvoltage category III 04/05/2016   Page 3 / 8 https://www.phoenixcontact.com/us/products/2900582 Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-0,6 - 2900582 Technical data Insulation characteristics Degree of pollution 2 Designation Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit Insulation Safe isolation (IEC 60947-1) at operating voltage ≤ 300 V AC (e.g., 230/400 V AC, 277/480 V AC) Safe isolation (EN 50178) at operating voltage ≤ 300 V A (e.g., 230/400 V AC, 277/480 V AC) Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC Designation Isolation characteristics between the control input and control supply voltage to auxiliary circuit Insulation Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC Approvals/conformities Safety Integrity Level according to IEC 61508 SIL 3 (safe shutdown) SIL 2 (motor protection) Category acc. to EN ISO 13849 3 (Safe shutdown) Performance level according to ISO 13849 e (Safe shutdown) ATEX  II (2) G [Ex e] [Ex d] [Ex px]  II (2) D [Ex t] [Ex p] EU type-examination certificate PTB 07 ATEX 3145 UL data SCCR 100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault))) 5 kA (480 V AC (fuse: 20 A RK5 (standard fault))) FLA 0.6 A (480 V AC) Group installation 20 A (class RK5, SCCR 5kA, 24 - 14 AWG max. solid and stranded) 30 A (class CC or J, SCCR 100kA, 24 - 14 AWG max, solid and stranded) Category code NLDX / NRNT Standards and Regulations Designation Standards/regulations Standards/regulations IEC 60947-1 EN 60947-4-2 IEC 61508 ISO 13849 ATEX  II (2) G [Ex e] [Ex d] [Ex px]  II (2) D [Ex t] [Ex p] 04/05/2016   Page 4 / 8 https://www.phoenixcontact.com/us/products/2900582 Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-0,6 - 2900582 Classifications eCl@ss eCl@ss 4.0 27371102 eCl@ss 4.1 27371102 eCl@ss 5.0 27371601 eCl@ss 5.1 27371601 eCl@ss 6.0 27371601 eCl@ss 7.0 27371601 eCl@ss 8.0 27370905 eCl@ss 9.0 27370905 ETIM ETIM 2.0 EC000066 ETIM 3.0 EC000066 ETIM 4.0 EC000066 ETIM 5.0 EC002055 UNSPSC UNSPSC 6.01 30211915 UNSPSC 7.0901 39121514 UNSPSC 11 39121514 UNSPSC 12.01 39121514 UNSPSC 13.2 39121514 Approvals Approvals Approvals UL Listed / cUL Listed / IECEE CB Scheme / GL / GL-SW / UL Listed / cUL Listed / EAC / cULus Listed / GL Ex Approvals ATEX Approvals submitted Approval details 04/05/2016   Page 5 / 8 https://www.phoenixcontact.com/us/products/2900582 Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-0,6 - 2900582 Approvals UL Listed  cUL Listed  IECEE CB Scheme  GL  GL-SW  UL Listed  cUL Listed  EAC  cULus Listed  GL  Drawings 04/05/2016   Page 6 / 8 https://www.phoenixcontact.com/us/products/2900582 Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-0,6 - 2900582 Load current [A] Diagram Block diagram MAN RES AUTO 9 8 7 6 5 4 3 2 1 0,18 1/L1 3/L2 5/L3 RES Logic µP Us T T 0 50 60 70 Ambient temperature [°C] = aligned with > 20 mm spacing = aligned without spacing 10 20 30 40 E & Error R L 97 96 95 2/T1 4/T2 6/T3 Derating diagram Circuit diagram L1 L2 L3 Circuit diagram +24V DC F5 F1 F2 F3 K5 K5 K5 K5 S2 F4 K1 T1 K2 K5 T2 K3 T3 K4 K1 K4 K3 K5 K5 K1 K2 K2 F4 M 3~ M1 K3 PE K4 K5 K5 GND Conventional structure Main current path for reversing contactor according to category 3 Conventional structure Control current path reversing contactor according to category 3 K1 + K2 = Emergency stop contactor K3 = Left contactor K4 = Right contactor F4 = Motor protection relay K1 + K2 = Emergency stop contactor K3 = Left contactor K4 = Right contactor K5 = PSR SCP-24DC.../Safety relay T1 = Right, T2 = Left, T3 = Reset S2 = Emergency stop F4 = Motor protection relay 04/05/2016   Page 7 / 8 https://www.phoenixcontact.com/us/products/2900582 Hybrid motor starter - ELR H5-IES-SC- 24DC/500AC-0,6 - 2900582 Circuit diagram L1 F1 F2 L2 F3 L3 +24V DC K5 L1 L2 L3 T3 K1 T1 T2 T3 T1 T2 K5 M 3~ M1 K5 K1 +US R L K5 K5 K5 K5 S2 E PE K5 GND Structure with CONTACTRON , , Main and control current path for 4 in 1 hybrid motor starter with reversing function according to category 3 , , K1 = 4 in 1 hybrid motor starter with reversing function K5 = PSR SCP-24DC.../Safety relay T1 = Right, T2 = Left, T3 = Reset S2 = Emergency stop Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 04/05/2016   Page 8 / 8
2900582 价格&库存

很抱歉,暂时无法提供与“2900582”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2900582
  •  国内价格
  • 1+1810.35185

库存:5