2901533

2901533

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    I/OMODULE3DIG/ANALOG3RELAY

  • 数据手册
  • 价格&库存
2901533 数据手册
https://www.phoenixcontact.com/us/products/2901533 I/O extension module - RAD-DAIO6-IFS - 2901533 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Analog/digital I/O extension module with 2 digital inputs/outputs (0...250 V AC/DC) and 1 analog input (0/4...20 mA) and output (0/4 ... 20 mA, 0...10 V), with screw connection, incl. DIN rail connector Product Features ■ ■ ■ ■ ■ ■ Channel-to-channel electrical isolation Extended temperature range, -40°C ... +70°C Easy module replacement even during operation (hot swap) Digital wide-range inputs/outputs (0 ...250 V AC/DC) Suitable for ATEX zone 2 Easy startup via thumbwheel Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 240.0 g Custom tariff number 85389091 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 17.5 mm Height 99 mm Depth 114.5 mm 03/13/2016   Page 1 / 11 https://www.phoenixcontact.com/us/products/2901533 I/O extension module - RAD-DAIO6-IFS - 2901533 Technical data Ambient conditions Degree of protection IP20 Ambient temperature (operation) -40 °C ... 70 °C (>55°C derating) -40 °F ... 158 °F (>131°F derating) Ambient temperature (storage/transport) -40 °C ... 85 °C -40 °F ... 185 °F Permissible humidity (operation) 20 % ... 85 % Permissible humidity (storage/transport) 20 % ... 85 % Altitude 2000 m Vibration (operation) in accordance with IEC 60068-2-6: 5g, 10 Hz ... 150 Hz Shock 16g, 11 ms General Overvoltage category II Mounting position any Assembly instructions on standard DIN rail NS 35 in accordance with EN 60715 Degree of pollution 2 Housing material PA 6.6-FR Flammability rating according to UL 94 V0 MTTF 889 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) 391 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) 151 Years (Telcordia standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day)) Supply Supply voltage range 19.2 V DC ... 30.5 V DC (DIN rail connector) Max. current consumption ≤ 95 mA (At 24 V DC, at 25°C) Transient surge protection Yes Analog inputs Number of inputs 1 Current input signal 0 mA ... 20 mA (can be set via DIP switches) 4 mA ... 20 mA (can be set via DIP switches) Max. current input signal 22 mA Input resistance current input < 70 Ω Precision ≤ 0.02 % (at 25 °C) Temperature coefficient, typical typ. 0.0025 %/K (at -40 °C ... +70 °C) Supply voltage ≥ 12 V DC (For passive sensors (via terminal PWR1, +I1)) Resolution 16 (Bit) 03/13/2016   Page 2 / 11 https://www.phoenixcontact.com/us/products/2901533 I/O extension module - RAD-DAIO6-IFS - 2901533 Technical data Analog inputs Protective circuit Short-circuit and overload protection Digital inputs Description of the input Digital input Number of inputs 2 Switching level "1" signal 10 V AC/DC ... 50 V AC/DC (Low-voltage input) 50 V AC/DC ... 250 V AC/DC (High-voltage input) Switching level "0" signal 0 V AC/DC ... 4 V AC/DC (Low-voltage input) 0 V AC/DC ... 20 V AC/DC (High-voltage input) Input frequency ≤ 2 Hz Analog outputs Number of outputs 1 Voltage output signal 0 V ... 10 V Max. voltage output signal approx. 10.83 V Load ≥ 10 kΩ Precision typ. 0.5 % (Voltage output) Current output signal 0 mA ... 20 mA 4 mA ... 20 mA Max. current output signal approx. 21.67 mA Load ≤ 500 Ω Precision ≤ 0.02 % (at 25 °C) Resolution 16 bit Temperature coefficient, typical typ. 0.0025 %/K (at -40 °C ... +70 °C) Behavior of the outputs (adjustable via DIP switch) Hold / Reset Protective circuit Transient protection of outputs Digital outputs Number of outputs 2 Contact type PDT Contact material AgSnO2 Maximum switching voltage 250 V AC 24 V DC Min. switching current ≥ 10 mA Max. switching current 2A Mechanical service life 1 x 10 cycles Electrical service life 2 x 10 cycles (At 2 A, 250 V AC, cosφ 0.4) 7 5 5 2 x 10 cycles (At 1 A, 24 V DC, L/R = 48 ms) 03/13/2016   Page 3 / 11 https://www.phoenixcontact.com/us/products/2901533 I/O extension module - RAD-DAIO6-IFS - 2901533 Technical data Digital outputs Maximum switching frequency 2 Hz Switching capacity 48 W (24 V DC) 60 W (30 V DC) 20 W (48 V DC) 18 W (60 V DC) 22 W (110 V DC) 40 W (220 V DC) 42 W (250 V DC) Behavior of the outputs (adjustable via DIP switch) Hold / Reset Electrical isolation Digital I/O 300 V (Rated insulation voltage (in each case between the digital inputs // digital outputs // TBUS supply, reinforced insulation according to EN 61010)) Analog I/O 50 V (Rated insulation voltage (in each case between the TBUS analog inputs / analog outputs / supply, reinforced insulation according to EN 61010)) Digital/analog I/O 300 V (Rated insulation voltage (in each case between the digital inputs and outputs // analog inputs and outputs, reinforced insulation according to EN 61010)) Test voltage Digital I/O 2.5 kV AC (50 Hz, 1 min.) Analog I/O 1.5 kV AC (50 Hz, 1 min.) Connection data Connection method Screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 14 Stripping length 7 mm Tightening torque 0.6 Nm Screw thread M3 Status indicator Status display Green LED (supply voltage, PWR) Green LED (bus communication, DAT) Red LED (periphery error, ERR) Yellow LED (digital input, DI1) 03/13/2016   Page 4 / 11 https://www.phoenixcontact.com/us/products/2901533 I/O extension module - RAD-DAIO6-IFS - 2901533 Technical data Status indicator Yellow LED (digital input, DI2) Yellow LED (digital output, DO1) Yellow LED (digital output, DO2) Approvals and conformance Conformance CE-compliant IECEx Ex nA nC IIC T4 Gc UL, USA / Canada UL 508 Listed Standard designation EMC Directive 2004/108/EC Standards/regulations EN 61000-6-2 Standard designation EMC Directive 2004/108/EC Standards/regulations EN 61000-6-4 Standard designation Ex Directive (ATEX) Standards/regulations EN 60079-0 Standard designation Ex Directive (ATEX) Standards/regulations EN-60079-15 Standards and Regulations Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC (valid until 19.04.2016) / 2014/30/EU (valid from 20.04.2016) Standard designation EMC Directive 2004/108/EC Standards/regulations EN 61000-6-2 Standard designation EMC Directive 2004/108/EC Standards/regulations EN 61000-6-4 Standard designation Ex Directive (ATEX) Standards/regulations EN 60079-0 Standard designation Ex Directive (ATEX) Standards/regulations EN-60079-15 Shock 16g, 11 ms Flammability rating according to UL 94 V0 Vibration (operation) in accordance with IEC 60068-2-6: 5g, 10 Hz ... 150 Hz Conformance CE-compliant ATEX  II 3 G Ex nA nC IIC T4 Gc X IECEx Ex nA nC IIC T4 Gc UL, USA / Canada UL 508 Listed Class I, Div. 2, Groups A, B, C, D T4A Class I, Zone 2, IIC T4 03/13/2016   Page 5 / 11 https://www.phoenixcontact.com/us/products/2901533 I/O extension module - RAD-DAIO6-IFS - 2901533 Classifications eCl@ss eCl@ss 4.0 27230207 eCl@ss 4.1 27230207 eCl@ss 5.0 27230207 eCl@ss 5.1 27242208 eCl@ss 6.0 27242208 eCl@ss 7.0 27242208 eCl@ss 8.0 27242602 ETIM ETIM 3.0 EC001423 ETIM 4.0 EC000310 ETIM 5.0 EC001597 UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 43223108 UNSPSC 11 39121008 UNSPSC 12.01 43223108 UNSPSC 13.2 43223108 Approvals Approvals Approvals UL Listed / cUL Listed / EAC / cULus Listed Ex Approvals ATEX / IECEx / UL Listed / cUL Listed Approvals submitted Approval details 03/13/2016   Page 6 / 11 https://www.phoenixcontact.com/us/products/2901533 I/O extension module - RAD-DAIO6-IFS - 2901533 Approvals UL Listed  cUL Listed  EAC  cULus Listed  Drawings Schematic diagram Schematic diagram DI1L DI1N DI1 DI2L DI 02N DI2 -I1 U1 +I1 ANT DI1L DI1N DI1 DI2L DI 02N DI2 -I1 U1 +I1 ANT OFF ON OFF ON 1 2 3 4 1 2 3 4 DAT 1 2 DIP-1 PWR IO-MAP PWR DAT ERR ERR DO1 DO1 DO2 1 2 IO-MAP DIP-1 DO2 DO3 DO3 DO4 DO4 U1 I1 1 COM1 NO1 NC1 COM2 NO2 NC2 U1 I1 1 COM1 NO1 NC1 COM2 NO2 NC2 DIP switches Thumb wheel Schematic diagram DI1L DI1N DI1 DI2L DI 02N DI2 -I1 U1 +I1 ANT Block diagram PWR IN 3.1 2 Wire Out 3.2 PWR IN OFF ON 1 2 3 4 3 Wire DIP-1 Out DAT 1 2 IO-MAP GND PWR ERR Out US 4 Wire GND DI1 3.2 3.2 3.3 3.3 3.2 3.3 DO4 U1 I1 1 COM1 NO1 NC1 COM2 NO2 NC2 10...50V AC/DC GND 50...250V AC/DC GND 0...10V DC LED indicators 0/4...20 mA GND 2.1 2.2 2.3 DI2 DO3 3.1 3.1 IO-MAP PWR1 -I1 U I VLOOP +I1 I U1 I1 1 DI2L COM1 DI2H NO1 µC DI2 NC1 4.1 4.2 4.3 5.1 5.2 5.3 2.1 2.3 1.1 1.2 1.2 1.3 1.3 4.1 4.2 DI1L COM2 DI1H NO2 DI1 NC2 DC 6.1 6.2 6.3 IFS DC IFS 4.3 5.1 24 V DC/250 V AC 5.2 03/13/2016   Page 7 / 11 https://www.phoenixcontact.com/us/products/2901533 I/O extension module - RAD-DAIO6-IFS - 2901533 Functional drawing Dimensional drawing 99 +24 V 0 V RSSI+ RSSIANT 1 2 DAT 114,5 PWR ERR RAD-DAIO6-IFS OFF ON 1 2 3 4 DIP-1 IO-MAP SPORT RAD-2400-IFS 0 1 RAD-ID DI1L DI1H DI1 DI2L DI2H DI2 UL1 +I1 -I1 PWR DAT 17,5 Reset ERR DI1 DI2 DO1 RX TX DO2 D(A) D(B) RX TX GND CO1 CO2 NC1 U1 I1 1 COM1 NO1 NC1 COM2 NO2 NC2 +24 V 0 V RSSI+ RSSIANT PWR DAT ERR PWR DAT 1 2 RAD-DAIO6-IFS OFF ON 1 2 3 4 DIP-1 IO-MAP SPORT RAD-2400-IFS 0 2 RAD-ID DI1L DI1H DI1 DI2L DI2H DI2 UL1 +I1 -I1 Reset ERR DI1 DI2 DO1 RX TX D(A) D(B) RX TX GND CO1 CO2 NC1 DO2 U1 I1 1 COM1 NO1 NC1 COM2 NO2 NC2 RAD-DAIO6-IFS assignment: analog/digital inputs and outputs 03/13/2016   Page 8 / 11 https://www.phoenixcontact.com/us/products/2901533 I/O extension module - RAD-DAIO6-IFS - 2901533 Schematic diagram 3 2 1 DI 1L DI 1H DI 1 DI 2L DI 2H 6 DI 2 Pw r1 +I 1 -I 1 7 3 4 15 DI P-1 PW R 8 DA T 14 ER R 8 RAD-DAIO6-IFS F ON 13 8 1 OF 1 2 5 IO-MAP 16 4 DI DI 1L DI Pw2L D 1H D r1 I2H I +I DI 1 1 2 -I DI 1 DI 2 12 DO 1 DO 2 U 1 CO M CO I1 1 M 2 NO 1 NO1 N C 2 NC1 11 2 10 9 Function elements 03/13/2016   Page 9 / 11 https://www.phoenixcontact.com/us/products/2901533 I/O extension module - RAD-DAIO6-IFS - 2901533 Application drawing Wireless module in I/O data mode 03/13/2016   Page 10 / 11 https://www.phoenixcontact.com/us/products/2901533 I/O extension module - RAD-DAIO6-IFS - 2901533 Application drawing Wireless module in PLC/Modbus RTU mode Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 03/13/2016   Page 11 / 11