2901995

2901995

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    PHOENIX CONTACT - 2901995 - LOOP-POWERED ISOLATOR, 1CH, CURRENT, 30V

  • 数据手册
  • 价格&库存
2901995 数据手册
https://www.phoenixcontact.com/gb/products/2901995 Loop-powered isolators - MINI MCR-2-I-I-ILP-PT - 2901995 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Single-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology. Product Description Single-channel input-loop-powered 2-way isolator with plug-in connection technology for the electrical isolation and filtering of analog signals. The input-loop-powered isolator allows operation with active sensor technology with a supply voltage of 9.6 V DC ... 30 V DC. The device is powered via the current loop of the sensor. Input signal = output signal: 0(4) mA ... 20 mA. The measuring transducer supports NFC communication. Key Commercial Data Packing unit 1 STK GTIN GTIN 4046356649261 Weight per Piece (excluding packing) 52.200 g Custom tariff number 85437090 Country of origin Germany Technical data Dimensions Width 6.2 mm Height 110.5 mm Depth 120.5 mm Ambient conditions Ambient temperature (operation) -40 °C ... 70 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Maximum altitude < 2000 m Input data Description of the input Current input 04/16/2018   Page 1 / 9 https://www.phoenixcontact.com/gb/products/2901995 Loop-powered isolators - MINI MCR-2-I-I-ILP-PT - 2901995 Technical data Input data Number of inputs 1 Configurable/programmable no Current input signal 0 mA ... 20 mA 4 mA ... 20 mA Response current approx. 200 µA Input voltage limitation 30 V Voltage dissipation 3.1 V (I = 20 mA) Output data Output name Current output Number of outputs 1 Configurable/programmable no Current output signal 0 mA ... 20 mA 4 mA ... 20 mA Load/output load current output < 600 Ω (at I = 20 mA output signal) Transmission Behavior 1:1 to input signal Power supply Supply voltage range 9.6 V DC ... 30 V DC (no separate supply voltage necessary) Power consumption 600 mW Connection data Connection method Push-in connection Single conductor/terminal point, solid, with ferrule, min. 0.14 mm² Single conductor/terminal point, solid, with ferrule, max. 2.5 mm² Single conductor/terminal point, solid, without ferrule, min. 0.14 mm² Single conductor/terminal point, solid, without ferrule, max. 2.5 mm² Conductor cross section flexible min. 0.14 mm² Conductor cross section flexible max. 2.5 mm² Min. AWG conductor cross section, flexible 24 Max. AWG conductor cross section, flexible 12 Stripping length 10 mm General No. of channels 1 Maximum transmission error ≤ 0.1 % (of final value) Maximum temperature coefficient ≤ 0.002 %/K (of measured value / 100 Ω load) Additional error, load-dependent < 0.075 % (of measured value / 100 Ω load) Limit frequency (3 dB) 100 Hz Electrical isolation Reinforced insulation in accordance with IEC 61010-1 Overvoltage category II Degree of pollution 2 Rated insulation voltage 300 V (effective) 04/16/2018   Page 2 / 9 https://www.phoenixcontact.com/gb/products/2901995 Loop-powered isolators - MINI MCR-2-I-I-ILP-PT - 2901995 Technical data General Test voltage, input/output/supply 3 kV (50 Hz, 1 min.) Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Color gray Housing material PBT Mounting position any Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA/Canada UL 508 Listed Class I, Div. 2, Groups A, B, C, D T6 Class I, Zone 2, Group IIC T6 GL GL applied for Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2 Standards and Regulations Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Electrical isolation Reinforced insulation in accordance with IEC 61010-1 Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA/Canada UL 508 Listed Class I, Div. 2, Groups A, B, C, D T6 Class I, Zone 2, Group IIC T6 GL GL applied for Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2 HL 1 - HL 2 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2 HL 1 - HL 2 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2 HL 1 - HL 2 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 2 HL 1 - HL 2 HL 1 - HL 2 Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings 04/16/2018   Page 3 / 9 https://www.phoenixcontact.com/gb/products/2901995 Loop-powered isolators - MINI MCR-2-I-I-ILP-PT - 2901995 Application drawing UV = 3,1 V I US 4-wire Pictogram UE I RB I US = ! 30 V DC MINI MCR-2-I-I-ILP Us " UE = 3,1 V + 20 mA x RB IN POWER I I OUT Block diagram Sensor / Field OUT IN TI– + 1 OUT I+ US 4-wire 1 PWR max 30VDC 2 OUT I- IN I+ TI+ 5 + OUT I+ active – 2 5 passive 6 – IN I– 3 PLC / DCS 6 OUT I– 7 8 4 Zone 2 Classifications eCl@ss eCl@ss 4.0 27210120 eCl@ss 4.1 27210120 eCl@ss 5.0 27210120 eCl@ss 5.1 27210120 eCl@ss 6.0 27210120 eCl@ss 7.0 27210120 eCl@ss 8.0 27210120 eCl@ss 9.0 27210120 ETIM ETIM 4.0 EC002653 ETIM 5.0 EC002653 ETIM 6.0 EC002653 04/16/2018   Page 4 / 9 https://www.phoenixcontact.com/gb/products/2901995 Loop-powered isolators - MINI MCR-2-I-I-ILP-PT - 2901995 Classifications UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 39121008 Approvals Approvals Approvals UL Listed / cUL Listed / cULus Listed Ex Approvals UL Listed / cUL Listed / ATEX / cULus Listed Approval details UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 238705 cUL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 238705 cULus Listed       Accessories Accessories Communication module Communication module - MINI MCR-2-V8-MOD-RTU - 2905634 Eight MINI Analog Pro signal conditioners and measuring transducers can be quickly and easily integrated into a Modbus/RTU network via a communication adapter.     04/16/2018   Page 5 / 9 https://www.phoenixcontact.com/gb/products/2901995 Loop-powered isolators - MINI MCR-2-I-I-ILP-PT - 2901995 Accessories Communication module - MINI MCR-2-V8-MOD-TCP - 2905635 Eight MINI Analog Pro signal conditioners and measuring transducers can be quickly and easily integrated into a Modbus/TCP network via a communication adapter.     Communication module - MINI MCR-2-V8-PB-DP - 2905636 Eight MINI Analog Pro signal conditioners and measuring transducers can be quickly and easily integrated into a PROFIBUS DP network via a communication adapter.     Device marking Marker for end clamp - UCT-EM (30X5) - 0801505 Marker for end clamp, Sheet, white, unlabeled, can be labeled with: THERMOMARK PRIME, THERMOMARK CARD, BLUEMARK CLED, BLUEMARK LED, TOPMARK LASER, mounting type: snapped into marker carrier, lettering field size: 30 x 5 mm     Marker for end clamp - UCT-EM (30X5) YE - 0830340 Marker for end clamp, Sheet, yellow, unlabeled, can be labeled with: THERMOMARK PRIME, THERMOMARK CARD, BLUEMARK CLED, BLUEMARK LED, TOPMARK LASER, mounting type: snapped into marker carrier, lettering field size: 30 x 5 mm     Plastic label - UC-EMLP (15X5) - 0819301 Plastic label, Sheet, white, unlabeled, can be labeled with: BLUEMARK CLED, BLUEMARK LED, CMS-P1PLOTTER, PLOTMARK, mounting type: adhesive, lettering field size: 15 x 5 mm     04/16/2018   Page 6 / 9 https://www.phoenixcontact.com/gb/products/2901995 Loop-powered isolators - MINI MCR-2-I-I-ILP-PT - 2901995 Accessories Plastic label - UC-EMLP (15X5) YE - 0822615 Plastic label, Sheet, yellow, unlabeled, can be labeled with: BLUEMARK CLED, BLUEMARK LED, CMS-P1PLOTTER, PLOTMARK, mounting type: adhesive, lettering field size: 15 x 5 mm     Plastic label - UC-EMLP (15X5) SR - 0828095 Plastic label, Sheet, silver, unlabeled, can be labeled with: BLUEMARK CLED, BLUEMARK LED, CMS-P1PLOTTER, PLOTMARK, mounting type: adhesive, lettering field size: 15 x 5 mm     Plastic label - US-EMLP (15X5) - 0828790 Plastic label, Card, white, unlabeled, can be labeled with: THERMOMARK PRIME, THERMOMARK CARD, mounting type: adhesive, lettering field size: 15 x 5 mm     Plastic label - US-EMLP (15X5) YE - 0828873 Plastic label, Card, yellow, unlabeled, can be labeled with: THERMOMARK PRIME, THERMOMARK CARD, mounting type: adhesive, lettering field size: 15 x 5 mm     Plastic label - US-EMLP (15X5) SR - 0828874 Plastic label, Card, silver, unlabeled, can be labeled with: THERMOMARK PRIME, THERMOMARK CARD, mounting type: adhesive, lettering field size: 15 x 5 mm     Labeled device marker 04/16/2018   Page 7 / 9 https://www.phoenixcontact.com/gb/products/2901995 Loop-powered isolators - MINI MCR-2-I-I-ILP-PT - 2901995 Accessories Marker for end clamp - UCT-EM (30X5) CUS - 0801589 Marker for end clamp, can be ordered: by sheet, white, labeled according to customer specifications, mounting type: snapped into marker carrier, lettering field size: 30 x 5 mm     Marker for end clamp - UCT-EM (30X5) YE CUS - 0830348 Marker for end clamp, can be ordered: by sheet, yellow, labeled according to customer specifications, mounting type: snapped into marker carrier, lettering field size: 30 x 5 mm     Plastic label - UC-EMLP (15X5) CUS - 0824550 Plastic label, can be ordered: by sheet, white, labeled according to customer specifications, mounting type: adhesive, lettering field size: 15 x 5 mm     Plastic label - UC-EMLP (15X5) YE CUS - 0824551 Plastic label, can be ordered: by sheet, yellow, labeled according to customer specifications, mounting type: adhesive, lettering field size: 15 x 5 mm     Plastic label - UC-EMLP (15X5) SR CUS - 0828099 Plastic label, can be ordered: by sheet, silver, labeled according to customer specifications, mounting type: adhesive, lettering field size: 15 x 5 mm     04/16/2018   Page 8 / 9 https://www.phoenixcontact.com/gb/products/2901995 Loop-powered isolators - MINI MCR-2-I-I-ILP-PT - 2901995 Accessories Plastic label - US-EMLP (15X5) CUS - 0830076 Plastic label, can be ordered: By card, white, labeled according to customer specifications, mounting type: adhesive, lettering field size: 15 x 5 mm     Plastic label - US-EMLP (15X5) YE CUS - 0830077 Plastic label, can be ordered: By card, yellow, labeled according to customer specifications, mounting type: adhesive, lettering field size: 15 x 5 mm     Plastic label - US-EMLP (15X5) SR CUS - 0830078 Plastic label, can be ordered: By card, silver, labeled according to customer specifications, mounting type: adhesive, lettering field size: 15 x 5 mm     System adapter System adapter - MINI MCR-2-V8-FLK 16 - 2901993 Eight MINI Analog Pro signal conditioners and measuring transducers can be connected to a controller with minimal cabling effort and without any errors using system adapters and system cabling.     Terminal marking Marker strip - SK 5,0 WH:REEL - 0805221 Marker strip, Roll, white, unlabeled, can be labeled with: THERMOMARK ROLL, THERMOMARK ROLL X1, THERMOMARK ROLLMASTER 300/600, THERMOMARK X1.2, THERMOMARK S1.1, mounting type: adhesive, for terminal block width: 5 mm, lettering field size: continuous x 5 mm     Phoenix Contact 2018 © - all rights reserved http://www.phoenixcontact.com 04/16/2018   Page 9 / 9
2901995 价格&库存

很抱歉,暂时无法提供与“2901995”相匹配的价格&库存,您可以联系我们找货

免费人工找货