0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2902019

2902019

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    MINI MCR-2-U-UI

  • 数据手册
  • 价格&库存
2902019 数据手册
MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 Please be informed that the data shown in this PDF document is generated from our online catalog. Please find the complete data in the user documentation. Our general terms of use for downloads are valid. 3-way signal conditioner, with configurable input/output, for electrical isolation and conversion of analog signals in the mV and V range, unipolar as well as bipolar. Screw connection technology, standard configuration. Product description Voltage signal 3-way signal conditioner with pluggable connection technology for the electrical isolation, conversion, amplification, and filtering of mV signals to V signals. Input signals from -50 mV ... 50 mV / -30 V ... 30 V and output signals from -10 V ... 10 V / 0(4) mA ... 20mA  are supported. The measuring transducer supports fault monitoring and NFC communication. Commercial data Item number 2902019 Packing unit 1 pc Minimum order quantity 1 pc Sales key C404 Product key CK1411 Catalog page Page 74 (C-5-2019) GTIN 4046356649674 Weight per piece (including packing) 123.2 g Weight per piece (excluding packing) 74.43 g Customs tariff number 85437090 Country of origin DE Jan 8, 2024, 9:04 AM Page 1 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 Technical data Notes Utilization restriction EMC note EMC: class A product, see manufacturer's declaration in the download area Product properties Product type Signal conditioner Product family MINI Analog Pro No. of channels 1 Type Signal conditioner Configuration DIP switches Insulation characteristics: GB Standard Overvoltage category II Pollution degree 2 Electrical properties No. of channels 1 Electrical isolation 3-way isolation Electrical isolation between input and output yes Limit frequency (3 dB) 30 Hz (via DIP switch) 5 kHz (via DIP switch) Protective circuit Transient protection Step response (10-90%) < 8.5 ms (with 30 Hz filter) Maximum temperature coefficient 0.01 %/K Maximum transmission error ≤ 0.1 % (of final value) Electrical isolation Input/output/power supply Rated insulation voltage 300 Vrms Test voltage 3 kV AC (50 Hz, 60 s) Insulation Reinforced insulation according to IEC/EN 61010-1 Supply Nominal supply voltage 24 V DC Supply voltage range 9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) Typical current consumption 25 mA (Current output, at 24 V DC incl. load) 54 mA (Current output, at 12 V DC incl. load) Power consumption ≤ 800 mW (at IOUT = 20 mA, 9.6 V DC, 600 Ω load) Input data Jan 8, 2024, 9:04 AM Page 2 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 Signal: Voltage Number of inputs 1 Configurable/programmable Yes Input signal Voltage Voltage input signal -50 mV ... 50 mV (via DIP switch) 0 mV ... 50 mV (via DIP switch) -60 mV ... 60 mV (via DIP switch) 0 mV ... 60 mV (via DIP switch) -75 mV ... 75 mV (via DIP switch) 0 mV ... 75 mV (via DIP switch) -80 mV ... 80 mV (via DIP switch) 0 mV ... 80 mV (via DIP switch) -100 mV ... 100 mV (via DIP switch) 0 mV ... 100 mV (via DIP switch) -120 mV ... 120 mV (via DIP switch) 0 mV ... 120 mV (via DIP switch) -150 mV ... 150 mV (via DIP switch) 0 mV ... 150 mV (via DIP switch) -200 mV ... 200 mV (via DIP switch) 0 mV ... 200 mV (via DIP switch) -240 mV ... 240 mV (via DIP switch) 0 mV ... 240 mV (via DIP switch) -300 mV ... 300 mV (via DIP switch) 0 mV ... 300 mV (via DIP switch) -500 mV ... 500 mV (via DIP switch) 0 mV ... 500 mV (via DIP switch) -600 mV ... 600 mV (via DIP switch) 0 mV ... 600 mV (via DIP switch) -750 mV ... 750 mV (via DIP switch) 0 mV ... 750 mV (via DIP switch) -800 mV ... 800 mV (via DIP switch) 0 mV ... 800 mV (via DIP switch) -1 V ... 1 V (via DIP switch) 0 V ... 1 V (via DIP switch) -1.2 V ... 1.2 V (via DIP switch) 0 V ... 1.2 V (via DIP switch) -1.5 V ... 1.5 V (via DIP switch) 0 V ... 1.5 V (via DIP switch) -2 V ... 2 V (via DIP switch) 0 V ... 2 V (via DIP switch) -2.4 V ... 2.4 V (via DIP switch) 0 V ... 2.4 V (via DIP switch) -3 V ... 3 V (via DIP switch) Jan 8, 2024, 9:04 AM Page 3 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 0 V ... 3 V (via DIP switch) -5 V ... 5 V (via DIP switch) 0 V ... 5 V (via DIP switch) -6 V ... 6 V (via DIP switch) 0 V ... 6 V (via DIP switch) -7.5 V ... 7.5 V (via DIP switch) 0 V ... 7.5 V (via DIP switch) -8 V ... 8 V (via DIP switch) 0 V ... 8 V (via DIP switch) -10 V ... 10 V (via DIP switch) 0 V ... 10 V (via DIP switch) -12 V ... 12 V (via DIP switch) 0 V ... 12 V (via DIP switch) -15 V ... 15 V (via DIP switch) 0 V ... 15 V (via DIP switch) -20 V ... 20 V (via DIP switch) 0 V ... 20 V (via DIP switch) -24 V ... 24 V (via DIP switch) 0 V ... 24 V (via DIP switch) -30 V ... 30 V (via DIP switch) 0 V ... 30 V (via DIP switch) Max. voltage input signal 33 V Input resistance of voltage input > 10 kΩ Output data Signal: Voltage/current Number of outputs 1 Configurable/programmable Yes Voltage output signal 0 V ... 5 V (via DIP switch) 1 V ... 5 V (via DIP switch) -5 V ... 5 V (via DIP switch) 0 V ... 10 V (via DIP switch) 2 V ... 10 V (via DIP switch) -10 V ... 10 V (via DIP switch) Non-load voltage < 17 V Current output signal 0 mA ... 20 mA (via DIP switch) 4 mA ... 20 mA (via DIP switch) Max. current output signal 22 mA Short-circuit current < 32 mA Load/output load voltage output ≥ 10 kΩ Load/output load current output ≤ 600 Ω (at 20 mA) Ripple < 20 mVPP (at 600 Ω) < 20 mVPP (at 600 Ω) Jan 8, 2024, 9:04 AM Page 4 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 Connection data Connection method Screw connection Stripping length 10 mm Screw thread M3 Conductor cross section rigid 0.2 mm² ... 1.5 mm² (with ferrule) 0.14 mm² ... 2.5 mm² (without ferrule) Conductor cross section flexible 0.14 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 12 (flexible) Tightening torque 0.5 Nm ... 0.6 Nm Ex data Ex installation (EPL) Gc Div. 2 Signaling Status display Green LED (supply voltage) Dimensions Width 6.2 mm Height 109.81 mm Depth 119.2 mm Material specifications Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2 Housing material PBT Environmental and real-life conditions Ambient conditions Degree of protection IP20 (not assessed by UL) Ambient temperature (operation) -40 °C ... 70 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Altitude ≤ 2000 m Permissible humidity (operation) 5 % ... 95 % (non-condensing) Approvals CE Certificate CE-compliant ATEX Identification  II 3 G Ex ec ic IIC T4 Gc Certificate BVS 19 ATEX E 047 X Jan 8, 2024, 9:04 AM Page 5 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 UKCA Ex (UKEX) Identification  II 3 G Ex ec ic IIC T4 Gc Certificate PxCIF21UKEX2902000X IECEx Identification Ex ec ic IIC T4 Gc Certificate IECEx BVS 19.0041X CCC / China-Ex Identification Ex nA ic IIC T4 Gc UL, USA/Canada Identification UL 508 Listed Class I, Div. 2, Groups A, B, C, D T6 Class I, Zone 2, Group IIC T6 Shipbuilding approval Certificate DNV GL TAA00002UA EAC Ex Identification  2Ex ec ic IIC T4 Gc Certificate BY/112 02.01 TP012 103.01 00079 DNV GL data Temperature B Humidity B Vibration A EMC A Enclosure Required protection according to the Rules shall be provided upon installation on board EMC data Noise immunity EN 61000-6-2 Note When being exposed to interference, there may be minimal deviations. Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Electrostatic discharge Standards/regulations EN 61000-4-2 Electrostatic discharge Comments Safety measures must be taken to prevent electrostatic discharge. Electromagnetic HF field Designation Electromagnetic RF field Standards/regulations EN 61000-4-3 Jan 8, 2024, 9:04 AM Page 6 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 Fast transients (burst) Designation Fast transients (burst) Standards/regulations EN 61000-4-4 Surge current load (surge) Standards/regulations EN 61000-4-5 Conducted interference Designation Conducted interferences Standards/regulations EN 61000-4-6 Standards and regulations Electrical isolation 3-way isolation GB Standard Standards/regulations GB 3836.1 GB 3836.4 GB 3836.8 Mounting Mounting type DIN rail mounting Assembly instructions The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail. Mounting position any Jan 8, 2024, 9:04 AM Page 7 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 Drawings Block diagram IN Sensor / Field G OUT PLC / DCS M + ±...mV 2 – 2 + 3 – Battery – 4 IN U + TI+ 5 + OUT U, I+ active IN U – OUT U, I– PWR+ PWR+ PWR– passive 6 6 7 PWR– FM 5 8 PWR– PWR+ Shunt resistor + 1 1 Zone 2 Jan 8, 2024, 9:04 AM Page 8 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 Block diagram 4-wire OUT 1 U+ U- 2 + 1 – 2 + 3 – 4 IN U + PLC / DCS TI+ 5 + OUT U, I+ active 5 passive IN U – 6 OUT U, I– PWR+ PWR+ PWR– 7 PWR– FM 6 8 PWR– PWR+ US OUT IN Sensor / Field Zone 2 Jan 8, 2024, 9:04 AM Page 9 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 Approvals To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/2902019  DNV GL  UL Listed Approval ID: TAA00002UA Approval ID: FILE E 238705 CCC  Approval ID: 2021322310003859 cUL Listed  Approval ID: FILE E 238705  IECEx Approval ID: IECEx BVS 19.0041X  cUL Listed  UL Listed Approval ID: FILE E 196811 Approval ID: FILE E 196811  ATEX Approval ID: BVS 19 ATEX E 047 X cULus Listed cULus Listed Jan 8, 2024, 9:04 AM Page 10 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 Classifications ECLASS ECLASS-11.0 27210120 ECLASS-12.0 27210120 ECLASS-13.0 27210120 ETIM ETIM 9.0 EC002653 UNSPSC UNSPSC 21.0 39121000 Jan 8, 2024, 9:04 AM Page 11 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 Environmental product compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” Jan 8, 2024, 9:04 AM Page 12 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 Accessories ME 6,2 TBUS-2 1,5/5-ST-3,81 GY - DIN rail bus connectors 2695439 https://www.phoenixcontact.com/us/products/2695439 DIN rail connector (TBUS), 5-pos., for bridging the supply voltage, can be snapped onto NS 35/... DIN rail in accordance with EN 60715 ME 6,2 TBUS-2 1,5/5-ST-3,81 GN - DIN rail bus connectors 2869728 https://www.phoenixcontact.com/us/products/2869728 DIN rail connector for DIN rail mounting. Universal for TBUS housing. Goldplated contacts, 5-pos. Jan 8, 2024, 9:04 AM Page 13 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 TC-D37SUB-AIO16-MP-PS-UNI - Module carrier 2906640 https://www.phoenixcontact.com/us/products/2906640 Universal Termination Carrier for connecting 16 MINI Analog Pro signal conditioners to digital or analog I/O cards, via D-SUB connector, 37-pos. (1:1 connection), with HART multiplexer connection TC-D37SUB-ADIO16-MP-P-UNI - Module carrier 2906639 https://www.phoenixcontact.com/us/products/2906639 Universal Termination Carrier for connecting 16 MINI Analog Pro signal conditioners to digital or analog I/O cards, via D-SUB connector, 37-pos. (1:1 connection) Jan 8, 2024, 9:04 AM Page 14 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 MINI MCR-2-V8-FLK 16 - System adapter 2901993 https://www.phoenixcontact.com/us/products/2901993 Eight MINI Analog Pro signal conditioners and measuring transducers can be connected to a controller with minimal cabling effort and without any errors using system adapters and system cabling. MINI MCR-2-V8-MOD-RTU - Communication module 2905634 https://www.phoenixcontact.com/us/products/2905634 Eight MINI Analog Pro signal conditioners and measuring transducers are quickly and easily integrated into a Modbus/RTU network via a communication adapter. Jan 8, 2024, 9:04 AM Page 15 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 MINI MCR-2-V8-MOD-TCP - Communication module 2905635 https://www.phoenixcontact.com/us/products/2905635 Eight MINI Analog Pro signal conditioners and measuring transducers are quickly and easily integrated into a Modbus/TCP network via a communication adapter. MINI MCR-2-V8-PB-DP - Communication module 2905636 https://www.phoenixcontact.com/us/products/2905636 Eight MINI Analog Pro signal conditioners and measuring transducers are quickly and easily integrated into a PROFIBUS DP network via a communication adapter. Jan 8, 2024, 9:04 AM Page 16 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 MINI MCR-2-V8-PN - Communication module 2905637 https://www.phoenixcontact.com/us/products/2905637 Eight MINI Analog Pro signal conditioners and measuring transducers can be quickly and easily integrated into a PROFINET network via a communication adapter. FASTCON PRO-SET - Connector set 2906227 https://www.phoenixcontact.com/us/products/2906227 FASTCON Pro plug set consisting of four plugs with screw connection, one for each position on the module. Suitable for all MINI Analog Pro modules. Jan 8, 2024, 9:04 AM Page 17 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 FASTCON PRO-SET-PT - Connector set 2906228 https://www.phoenixcontact.com/us/products/2906228 FASTCON Pro plug set consisting of four plugs with push-in connection, one for each position on the module. Suitable for all MINI Analog Pro modules. UCT-EM (30X5) - Marker for end clamp 0801505 https://www.phoenixcontact.com/us/products/0801505 Marker for end clamp, Sheet, white, unlabeled, can be labeled with: TOPMARK NEO, TOPMARK LASER, BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: snapped, lettering field size: 30 x 5 mm, Number of individual labels: 24 Jan 8, 2024, 9:04 AM Page 18 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 UCT-EM (30X5) CUS - Marker for end clamp 0801589 https://www.phoenixcontact.com/us/products/0801589 Marker for end clamp, can be ordered: by sheet, white, labeled according to customer specifications, mounting type: snapped into marker carrier, lettering field size: 30 x 5 mm, Number of individual labels: 24 SK 5,0 WH:REEL - Marker strip 0805221 https://www.phoenixcontact.com/us/products/0805221 Marker strip, Roll, white, unlabeled, can be labeled with: THERMOMARK E.300 (D)/600 (D), THERMOMARK ROLL 2.0, THERMOMARK ROLL, THERMOMARK ROLL X1, THERMOMARK ROLLMASTER 300/600, THERMOMARK X1.2, mounting type: adhesive, lettering field size: continuous x 5 mm, Number of individual labels: 10 Jan 8, 2024, 9:04 AM Page 19 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 UC-EMLP (15X5) - Plastic label 0819301 https://www.phoenixcontact.com/us/products/0819301 Plastic label, Sheet, white, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels: 10 UC-EMLP (15X5) YE - Plastic label 0822615 https://www.phoenixcontact.com/us/products/0822615 Plastic label, Sheet, yellow, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels: 10 Jan 8, 2024, 9:04 AM Page 20 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 UC-EMLP (15X5) CUS - Plastic label 0824550 https://www.phoenixcontact.com/us/products/0824550 Plastic label, can be ordered: by sheet, white, labeled according to customer specifications, mounting type: adhesive, lettering field size: 15 x 5 mm UC-EMLP (15X5) YE CUS - Plastic label 0824551 https://www.phoenixcontact.com/us/products/0824551 Plastic label, can be ordered: by sheet, yellow, labeled according to customer specifications, mounting type: adhesive, lettering field size: 15 x 5 mm Jan 8, 2024, 9:04 AM Page 21 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 UC-EMLP (15X5) SR - Plastic label 0828095 https://www.phoenixcontact.com/us/products/0828095 Plastic label, Sheet, silver, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels: 10 UC-EMLP (15X5) SR CUS - Plastic label 0828099 https://www.phoenixcontact.com/us/products/0828099 Plastic label, can be ordered: by sheet, silver, labeled according to customer specifications, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels: 10 Jan 8, 2024, 9:04 AM Page 22 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 US-EMLP (15X5) - Plastic label 0828790 https://www.phoenixcontact.com/us/products/0828790 Plastic label, Card, white, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels: 189 US-EMLP (15X5) YE - Plastic label 0828873 https://www.phoenixcontact.com/us/products/0828873 Plastic label, Card, yellow, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels: 189 Jan 8, 2024, 9:04 AM Page 23 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 US-EMLP (15X5) SR - Plastic label 0828874 https://www.phoenixcontact.com/us/products/0828874 Plastic label, Card, silver, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels: 189 US-EMLP (15X5) CUS - Plastic label 0830076 https://www.phoenixcontact.com/us/products/0830076 Plastic label, can be ordered: by card, white, labeled according to customer specifications, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels: 189 Jan 8, 2024, 9:04 AM Page 24 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 US-EMLP (15X5) YE CUS - Plastic label 0830077 https://www.phoenixcontact.com/us/products/0830077 Plastic label, can be ordered: by card, yellow, labeled according to customer specifications, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels: 189 US-EMLP (15X5) SR CUS - Plastic label 0830078 https://www.phoenixcontact.com/us/products/0830078 Plastic label, can be ordered: by card, silver, labeled according to customer specifications, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels: 189 Jan 8, 2024, 9:04 AM Page 25 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 UCT-EM (30X5) YE - Marker for end clamp 0830340 https://www.phoenixcontact.com/us/products/0830340 Marker for end clamp, Sheet, yellow, unlabeled, can be labeled with: TOPMARK NEO, TOPMARK LASER, BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: snapped, lettering field size: 30 x 5 mm, Number of individual labels: 24 UCT-EM (30X5) YE CUS - Marker for end clamp 0830348 https://www.phoenixcontact.com/us/products/0830348 Marker for end clamp, can be ordered: by sheet, yellow, labeled according to customer specifications, mounting type: snapped into marker carrier, lettering field size: 30 x 5 mm, Number of individual labels: 24 Jan 8, 2024, 9:04 AM Page 26 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 MINI MCR-2-PTB - Power terminal block 2902066 https://www.phoenixcontact.com/us/products/2902066 Power terminal with plug-in connection technology for delivering the supply voltage to the DIN rail connector. Monitoring of the supply voltages in combination with the fault monitoring module. Screw connection technology MINI MCR-2-PTB-PT - Power terminal block 2902067 https://www.phoenixcontact.com/us/products/2902067 Power terminal with plug-in connection technology for delivering the supply voltage to the DIN rail connector. Monitoring of the supply voltages in combination with the fault monitoring module. Push-in connection technology Jan 8, 2024, 9:04 AM Page 27 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 QUINT4-SYS-PS/1AC/24DC/2.5/SC - Power supply unit 2904614 https://www.phoenixcontact.com/us/products/2904614 Primary-switched power supply, QUINT POWER, screw connection, DIN rail mounting, supply of devices possible via the TBUS DIN rail connector, protective coating, input: single-phase, output: 24 V DC/2.5 A MINI MCR-2-FM-RC - Monitoring block 2904504 https://www.phoenixcontact.com/us/products/2904504 Fault monitoring module with plug-in connection technology for evaluating and reporting group errors from the FM system and for monitoring the supply voltages. Error message via N/C contact. Screw connection technology, standard configuration Jan 8, 2024, 9:04 AM Page 28 (29) MINI MCR-2-U-UI - Signal conditioner 2902019 https://www.phoenixcontact.com/us/products/2902019 MINI MCR-2-FM-RC-PT - Monitoring block 2904508 https://www.phoenixcontact.com/us/products/2904508 Fault monitoring module with plug-in connection technology for evaluating and reporting group errors from the FM system and for monitoring the supply voltages. Error message via N/C contact. Push-in connection technology, standard configuration SZS 0,6X3,5 - Screwdriver 1205053 https://www.phoenixcontact.com/us/products/1205053 Actuation tool, for ST terminal blocks, insulated, also suitable for use as a bladed screwdriver, size: 0.6 x 3.5 x 100 mm, 2-component grip, with non-slip grip Phoenix Contact 2024 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA 586 Fulling Mill Road Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com Jan 8, 2024, 9:04 AM Page 29 (29)
2902019 价格&库存

很抱歉,暂时无法提供与“2902019”相匹配的价格&库存,您可以联系我们找货

免费人工找货