0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2902037

2902037

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    MINIMCR-2-UI-UI

  • 数据手册
  • 价格&库存
2902037 数据手册
MINI MCR-2-UI-UI(-PT)(-C) 3-way signal conditioner Data sheet 106006_en_02 1 © PHOENIX CONTACT 2016-02-10 Description The 3-way signal conditioner with pluggable connection technology and calibrated measuring range changeover can be configured using DIP switches and is used for the electrical isolation, conditioning, amplification, and filtering of unipolar and bipolar standard and normalized signals. On the input side, the standard analog signals 0 - 20 mA, 4 - 20 mA, 0 - 10 V, 0 - 5 V, 1 - 5 V, or -10 - 10 V and the signals 2 - 10 V, 0 - 20 V, 4 - 20 V, 0 - 24 V, 4.8 - 24 V, 6 - 30 V, 0 - 30 V, -5 - 5 V, -20 - 20 V, -24 - 24 V, -30 - 30 V, and -20 - 20 mA are available. On the output side, 0 - 20 mA, 4 - 20 mA, 0 - 10 V, 2...10 V, 0 - 5 V, 1 - 5 V, -10 - 10 V, and -5 - 5 V are available. Features – – – – – – – – Configurable 3-way signal conditioner with plug-in connection technology Input and output signal range and cut-off frequencies configurable via DIP switches Calibrated measuring range switch-over Approval for Ex-zone 2 (nA) Screw or push-in connection available Can be supplied configured or unconfigured Reinforced insulation according to IEC 61010-1 Supply voltage range 9.6 ... 30 V DC There is no need for adjustment following a measuring range changeover. WARNING: Correct usage in potentially explosive areas The module is a category 3 item of electrical equipment. It is absolutely vital to follow the instructions provided here during installation and observe the information in the "Safety regulations and installation notes". This device offers the option of NFC communication. You can use the MINI Analog Pro Smartphone app to call-up DIP switch setting help and comprehensive module information via the NFC interface of your Smartphone. The MINI Analog Pro Smartphone app is available to you free. Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products. This document is valid for the products listed in the “Ordering data”. MINI MCR-2-UI-UI(-PT)(-C) 2 Table of contents 1 Description .............................................................................................................................. 1 2 Table of contents ..................................................................................................................... 2 3 Ordering data .......................................................................................................................... 3 4 Technical data ......................................................................................................................... 5 5 Safety regulations and installation notes.................................................................................. 7 5.1 Installation notes ................................................................................................................. 7 5.2 Installation in Zone 2............................................................................................................. 7 5.3 UL Notes ........................................................................................................................... 7 6 Installation ............................................................................................................................... 8 6.1 Connection notes ................................................................................................................ 8 6.2 Structure ........................................................................................................................... 8 6.3 Block diagram ..................................................................................................................... 8 6.4 Power supply ...................................................................................................................... 8 6.5 Assembly........................................................................................................................... 9 6.6 FASTCON Pro plugs ............................................................................................................ 9 6.7 Fault monitoring FM ............................................................................................................. 9 6.8 Current measurement ......................................................................................................... 10 6.9 Marking ........................................................................................................................... 10 7 Configuration ......................................................................................................................... 11 7.1 Configuration table ............................................................................................................. 12 8 Status indicator...................................................................................................................... 12 106006_en_02 PHOENIX CONTACT 2 / 12 MINI MCR-2-UI-UI(-PT)(-C) 3 Ordering data Description Type Order No. Pcs./Pkt. 3-way signal conditioner with plug-in connection technology and calibrated measuring range changeover for the electrical isolation of unipolar and bipolar analog signals. Input/output configurable via DIP switch. Screw connection technology, standard configuration. MINI MCR-2-UI-UI 2902037 1 3-way signal conditioner with plug-in connection technology and calibrated measuring range changeover, for the electrical isolation of unipolar and bipolar analog signals. Input/output configurable via DIP switch. push-in connection technology, standard configuration. MINI MCR-2-UI-UI-PT 2902040 1 3-way signal conditioner with plug-in connection technology and calibrated measuring range changeover for the electrical isolation of unipolar and bipolar analog signals. Input/output configurable via DIP switch. Screw connection technology, order configuration. MINI MCR-2-UI-UI-C 2902036 1 3-way signal conditioner with plug-in connection technology and calibrated measuring range changeover for the electrical isolation of unipolar and bipolar analog signals. Input/output configurable via DIP switch. push-in connection technology, order configuration. MINI MCR-2-UI-UI-PT-C 2902039 1 Accessories Type Order No. Pcs./Pkt. DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold- ME 6,2 TBUS-2 1,5/5-ST-3,81 GN plated contacts, 5-pos. Plug component, Number of positions: 5, Pitch: 3.81 mm 2869728 10 Power terminal with plug-in connection technology for delivering the supply voltage to the DIN rail connector. Monitoring of the supply voltages in combination with the fault monitoring module. Screw connection technology MINI MCR-2-PTB 2902066 1 Power terminal with plug-in connection technology for delivering the supply voltage to the DIN rail connector. Monitoring of the supply voltages in combination with the fault monitoring module. Push-in connection technology MINI MCR-2-PTB-PT 2902067 1 Fault monitoring module with plug-in connection technology for evaluating and reporting group errors from the FM system and for monitoring the supply voltages. Error reporting via N/O contact. Screw connection technology, standard configuration MINI MCR-2-FM-RC 2904504 1 Fault monitoring module with plug-in connection technology for evaluating and reporting group errors from the FM system and for monitoring the supply voltages. Error reporting via N/O contact. Push-in connection technology, standard configuration MINI MCR-2-FM-RC-PT 2904508 1 Primary-switched MINI POWER supply for DIN rail mounting, input: 1phase, output: 24 V DC/1.5 A MINI-SYS-PS-100-240AC/24DC/1.5 2866983 1 Marker for end clamp, Sheet, white, unlabeled, can be labeled with: THERMOMARK CARD, BLUEMARK CLED, BLUEMARK LED, TOPMARK LASER, Mounting type: snapped into marker carrier, Lettering field: 30 x 5 mm UCT-EM (30X5) 0801505 10 Marker for end clamp, can be ordered: by sheet, white, labeled according to customer specifications, Mounting type: snapped into marker carrier, Lettering field: 30 x 5 mm UCT-EM (30X5) CUS 0801589 1 Marker for end clamp, Sheet, yellow, unlabeled, can be labeled with: THERMOMARK CARD, BLUEMARK CLED, BLUEMARK LED, TOPMARK LASER, Mounting type: snapped into marker carrier, Lettering field: 30 x 5 mm UCT-EM (30X5) YE 0830340 10 Marker for end clamp, can be ordered: by sheet, yellow, labeled according to customer specifications, Mounting type: snapped into marker carrier, Lettering field: 30 x 5 mm UCT-EM (30X5) YE CUS 0830348 1 Plastic label, Sheet, white, unlabeled, can be labeled with: BLUEMARK CLED, BLUEMARK LED, Plotter, Mounting type: Adhesive, Lettering field: 15 x 5 mm UC-EMLP (15X5) 0819301 10 Plastic label, Sheet, white, unlabeled, can be labeled with: BLUEMARK CLED, BLUEMARK LED, Plotter, Mounting type: Adhesive, Lettering field: 15 x 5 mm UC-EMLP (15X5)L 0820138 5 106006_en_02 PHOENIX CONTACT 3 / 12 MINI MCR-2-UI-UI(-PT)(-C) Accessories Type Order No. Pcs./Pkt. Plastic label, Sheet, yellow, unlabeled, can be labeled with: BLUEMARK CLED, BLUEMARK LED, Plotter, Mounting type: Adhesive, Lettering field: 15 x 5 mm UC-EMLP (15X5) YE 0822615 10 Plastic label, can be ordered: by sheet, white, labeled according to customer specifications, Mounting type: Adhesive, Lettering field: 15 x 5 mm UC-EMLP (15X5) CUS 0824550 1 Plastic label, can be ordered: by sheet, yellow, labeled according to customer specifications, Mounting type: Adhesive, Lettering field: 15 x 5 mm UC-EMLP (15X5) YE CUS 0824551 1 Plastic label, can be ordered: by sheet, white, labeled according to customer specifications, Mounting type: Adhesive, Lettering field: 15 x 5 mm UC-EMLP (15X5)L CUS 0824552 1 Plastic label, Sheet, yellow, unlabeled, can be labeled with: BLUEMARK CLED, BLUEMARK LED, Plotter, Mounting type: Adhesive, Lettering field: 15 x 5 mm UC-EMLP (15X5)L YE 0825325 5 Plastic label, can be ordered: by sheet, yellow, labeled according to customer specifications, Mounting type: Adhesive, Lettering field: 15 x 5 mm UC-EMLP (15X5)L YE CUS 0826680 1 Plastic label, Sheet, silver, unlabeled, can be labeled with: BLUEMARK CLED, BLUEMARK LED, Plotter, Mounting type: Adhesive, Lettering field: 15 x 5 mm UC-EMLP (15X5) SR 0828095 10 Plastic label, can be ordered: by sheet, silver, labeled according to customer specifications, Mounting type: Adhesive, Lettering field: 15 x 5 mm UC-EMLP (15X5) SR CUS 0828099 1 Plastic label, Sheet, silver, unlabeled, can be labeled with: BLUEMARK CLED, BLUEMARK LED, Plotter, Mounting type: Adhesive, Lettering field: 15 x 5 mm UC-EMLP (15X5)L SR 0828103 5 Marker strip, Roll, white, unlabeled, can be labeled with: THERMOMARK ROLL, THERMOMARK X, THERMOMARK S1.1, THERMOMARK ROLL X1, Mounting type: Adhesive, Lettering field: continuous x 5 mm SK 5,0 WH:REEL 0805221 1 Electronics housing ME 6,2 TBUS-2 1,5/5-ST-3,81 GY 2695439 10 106006_en_02 PHOENIX CONTACT 4 / 12 MINI MCR-2-UI-UI(-PT)(-C) 4 Technical data Input Number of inputs 1 Configurable/programmable Yes Voltage input signal 0 V ... 5 V (via DIP switch) 1 V ... 5 V (via DIP switch) -5 V ... 5 V (via DIP switch) 0 V ... 10 V (via DIP switch) 2 V ... 10 V (via DIP switch) -10 V ... 10 V (via DIP switch) 0 V ... 20 V (via DIP switch) 4 V ... 20 V (via DIP switch) -20 V ... 20 V (via DIP switch) 0 V ... 24 V (via DIP switch) 4.8 V ... 24 V (via DIP switch) -24 V ... 24 V (via DIP switch) 0 V ... 30 V (via DIP switch) 6 V ... 30 V (via DIP switch) -30 V ... 30 V (via DIP switch) Max. voltage input signal 33 V Current input signal 0 mA ... 20 mA (via DIP switch) 4 mA ... 20 mA (via DIP switch) -20 mA ... 20 mA (via DIP switch) Max. current input signal 24 mA Input resistance of voltage input > 1000 kΩ Input resistance current input approx. 63 Ω Output Number of outputs 1 Voltage output signal 0 V ... 5 V (via DIP switch) 1 V ... 5 V (via DIP switch) -5 V ... 5 V (via DIP switch) 0 V ... 10 V (via DIP switch) 2 V ... 10 V (via DIP switch) -10 V ... 10 V (via DIP switch) Short-circuit current < 32 mA Current output signal 0 mA ... 20 mA (via DIP switch) 4 mA ... 20 mA (via DIP switch) Max. current output signal 22 mA Non-load voltage < 17 V Configurable/programmable Yes Load/output load voltage output ≥ 10 kΩ Ripple < 20 mVPP (at 600 Ω) Load/output load current output ≤ 600 Ω (at 20 mA) Supply Nominal supply voltage 24 V DC Supply voltage range 9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715)) Typical current consumption 25 mA (Current output, at 24 V DC incl. load) 54 mA (Current output, at 12 V DC incl. load) Power consumption ≤ 800 mW (at IOUT = 20 mA, 9.6 V DC, 600 Ω load) Diagnostic and status indicators Operating voltage display 106006_en_02 Green LED PHOENIX CONTACT 5 / 12 MINI MCR-2-UI-UI(-PT)(-C) General data Limit frequency (3 dB) 30 Hz (via DIP switch) 5 kHz (via DIP switch) Maximum transmission error ≤ 0.1 % (of final value) ≤ 0.15 % (of final value, at IN: 4 ... 20 mA / OUT: -10 V ... 10 V) Maximum temperature coefficient 0.01 %/K Step response (10-90%) < 8.5 ms (with 30 Hz filter) Electrical isolation Reinforced insulation in accordance with IEC 61010-1 Overvoltage category II Mounting position any Degree of protection IP20 Degree of pollution 2 Rated insulation voltage 300 V (effective) Test voltage, input/output/supply 3 kV (50 Hz, 1 min.) Dimensions W/H/D 6.2 mm / 110.5 mm / 120.5 mm Type of housing PBT gray Connection data Screw connection Solid conductor cross section with ferrule 0.2 mm² ... 1.5 mm² 0.14 mm² ... 2.5 mm² Solid conductor cross section without ferrule 0.2 mm² ... 2.5 mm² 0.14 mm² ... 2.5 mm² Conductor cross section, flexible 0.2 mm² ... 1.5 mm² 0.14 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 12 24 ... 12 Stripping length 10 mm 10 mm Push-in connection Ambient conditions Ambient temperature (operation) -40 °C ... 70 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 5 % ... 95 % (non-condensing) Conformance with EMC Directive 2004/108/EC (valid until 19.04.2016) / 2014/30/EU (valid from 20.04.2016) Noise immunity according to EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Noise emission according to EN 61000-6-4 Conformance / approvals Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA / Canada UL 508 Listed UL, USA / Canada Class I, Div. 2, Groups A, B, C, D T6 UL, USA / Canada Class I, Zone 2, Group IIC T6 Shipbuilding DNV GL 14445-15HH C, EMC2 106006_en_02 PHOENIX CONTACT 6 / 12 MINI MCR-2-UI-UI(-PT)(-C) 5 Safety regulations and installation notes 5.1 Installation notes • • • • • • • • • • • The category 3 device is suitable for installation in potentially explosive area zone 2. It fulfills the requirements of EN 60079-0:2012 and EN 6007915:2010. Installation, operation, and maintenance may only be carried out by qualified electricians. Follow the installation instructions as described. When installing and operating the device, the applicable regulations and safety directives (including national safety directives), as well as generally approved technical regulations, must be observed. The safety data is provided in this package slip and on the certificates (conformity assessment, additional approvals where applicable). While the devices are in operation, contact-dangerous voltages may be present on the control elements. For this reason parameterization, conductor connection, and opening of the module lid are allowed only when devices are in a de-energized state unless the connected circuits are exclusively SELV or PELV circuits. The device must not be opened or modified. Do not repair the device yourself, replace it with an equivalent device. Repairs may only be carried out by the manufacturer. The manufacturer is not liable for damage resulting from violation. The IP20 protection (IEC 60529/EN 60529) of the device is intended for use in a clean and dry environment. The device must not be subject to mechanical strain and/or thermal loads, which exceed the limits described. The device is not designed for use in atmospheres with a danger of dust explosions. The device complies with the EMC regulations for industrial areas (EMC class A). When using the device in residential areas, it may cause radio interference. If the device is not used as described in the documentation, the intended protection can be negatively affected. To protect the device against mechanical or electrical damage, install it in a suitable housing with appropriate degree of protection as per IEC 60529. Provide a switch/circuit breaker close to the device, which is labeled as the disconnecting device for this device. Provide for a overcurrent protection device (I ≤ 4 A) in the installation. 106006_en_02 • • • • 5.2 • • • • 5.3 Thanks to its housing, the device has basic insulation to the neighboring devices, for 150 Veff. If several devices are installed next to each other, this has to be taken into account, and additional insulation has to be installed if necessary! The voltages present at the input, output and supply are extra-low voltages (ELV). Depending on the application, dangerous voltage (> 30 V) against ground could occur. For this event, safe electrical isolation from the other connections has been implemented. The device must be stopped if it is damaged, has been subjected to an impermissible load, stored incorrectly, or if it malfunctions. Only use copper connecting cables providing the permitted temperature range (60°C/75°C). Installation in Zone 2 Observe the specified conditions for use in potentially explosive areas! Install the device in a suitable approved housing (with a minimum of IP54 protection) that meets the requirements of EN 60079-15. Observe the requirements of EN 60079-14. Only devices which are designed for operation in Ex zone 2 and are suitable for the conditions at the installation location may be connected to the circuits in the Ex zone. In potentially explosive areas, terminals may only be snapped onto or off the DIN rail connector and wires may only be connected or disconnected when the power is switched off. The device must be stopped and immediately removed from the Ex area if it is damaged, was subject to an impermissible load, stored incorrectly or if it malfunctions. UL Notes INDUSTRIAL CONTROL EQUIPMENT FOR HAZARDOUS LOCATIONS 45FP 1 Suitable for use in class 1, division 2, groups A, B, C and D hazardous locations, or nonhazardous locations only. 2 WARNING - EXPLOSION HAZARD: Do not disconnect equipment unless power has been removed or the area is known to be non-hazardous. 3 WARNING - EXPLOSION HAZARD: Substitution of any components may impair suitability for Class I, Division 2. 4 This device is open-type and is required to be installed in an enclosure suitable for the environment and can only be accessed with the use of a tool or key. PHOENIX CONTACT 7 / 12 MINI MCR-2-UI-UI(-PT)(-C) 6 Installation 6.1 Connection notes 6.3 Block diagram The device contains components that can be damaged or destroyed by electrostatic discharge. When handling the device, observe the necessary safety precautions against electrostatic discharge (ESD) according to EN 61340-5-1 and IEC 61340-51. US OUT IN Sensor / Field TI– + 1 OUT 1 U,I IN U, I+ 4-wire GND – 2 2 + 3 – 4 PLC / DCS TI+ 5 + OUT U, I+ active 5 passive 6 – OUT U, I– IN U, I– PWR+ PWR+ PWR– 6 7 + PWR– 8 – FM Structure PWR– PWR+ 6.2 2 1 Zone 2 3 12 Figure 2 4 11 5 9 Supply via the module 6 7 8 Structure Green “PWR” LED, power supply Cover with labeling option Voltage/current input DIP switch S1 Supply voltage NFC coil Universal snap-on foot for EN DIN rails Connection for DIN rail connector Spindle screw DIP switch S2 Voltage output / current output Current measuring socket 106006_en_02 You must refer to the MACX and MINI Analog power manual for the design of the power supply. Never connect the supply voltage directly to the DIN rail connector. Drawing power from individual devices is not permitted!. 5 1 2 3 4 5 6 7 8 9 10 11 12 Power supply NOTE 10 Figure 1 6.4 Block diagram Where the total current consumption of the aligned modules does not exceed 400 mA, the power can be supplied directly at the connection terminal blocks of the module. We recommend connecting a 630 mA fuse (normal-blow or slow-blow) upstream. Supply via a power terminal block The MINI MCR-2-PTB power terminal block (Order No. 2902066) or the MINI MCR-2-PTB-PT power terminal block (Order No. 2902067) of the same shape is used to supply the supply voltage to the DIN rail connector. We recommend connecting a 4 A fuse upstream. PHOENIX CONTACT 8 / 12 MINI MCR-2-UI-UI(-PT)(-C) Supply via a system power supply unit Screw connection: The system power supply unit with 1.5 A output current connects the DIN rail connector to the supply voltage and can thus be used to supply several modules from the mains. – MINI-SYS-PS-100-240AC/24DC/1.5 (Order No. 2866983) – Potentially explosive areas: MINI-PS-100-240AC/24DC/1.5/EX (Order No. 2866653) 6.5 AWG 26-16 2 0,2-1,5 mm MINI MCR-2-… B 10 mm Assembly A A B Figure 4 C • E 0,5-0,6 Nm 5-7 lb ln Screw connection Insert the wire into the corresponding connection terminal block. Use a screwdriver to tighten the screw in the opening above the connection terminal block. • D Push-in connection: AWG 26-12 0,2-2,5 mm2 Figure 3 – – 6.6 FASTCON Pro plugs The device has pluggable connection terminals with an integrated test disconnect terminal block, with either push-in or screw-in connection technology. You can plug or screw the FASTCON Pro plugs onto the device directly without tools. You can use the integrated spindle screw to easily remove the plugs from the module or set the isolating position, even when the plugs are connected. For this purpose, use a screwdriver of sufficient width, e.g. SZF 1-0.6x3.5 (order number: 1204517). 4-way coding prevents incorrect insertion into the module. 106006_en_02 A 10 mm Mounting and removing Mount the module on a 35 mm DIN rail according to EN 60715. When using the DIN rail connector, first place it into the DIN rail (see A – C). It is used to bridge the power supply. It is also absolutely vital that you snap the module and the DIN rail connector into position in the correct direction: the snap-on foot should be at the bottom and the connector on the left. MINI MCR-2-…-PT A B Figure 5 • 6.7 Push-in connection Insert the wire into the corresponding connection terminal block. Fault monitoring FM A module or power supply failure is reported to the formmatched MINI MCR-2-FM-RC fault monitoring module (order number 2904504) or MINI MCR-2-FM-RC-PT fault monitoring module (order number 2904508) via the DIN rail connector. The module reports the error centrally via an N/C contact. A fault monitoring module is only required once in a group. There is no need for individual evaluation of up to 115 connected Mini Analog Pro signal conditioners. PHOENIX CONTACT 9 / 12 MINI MCR-2-UI-UI(-PT)(-C) 6.8 Current measurement The device allows current measurement without disconnection of the conductors by means of integrated test disconnect terminals. Test sockets which support current measurement are marked TI+ or TI-. For the current measurement, use 2 mm probe tips of the type Fluke TL75-1 or probe tips with a comparable tip shape. Figure 6 Test disconnect terminal block Furthermore, individual circuits can be specifically disconnected, e.g. for commissioning. You can set the isolating position by turning the integrated spindle screw through 180°. The isolating position is indicated by the marking on the plugs. Figure 7 6.9 Disconnect position Marking Standard UCT-EM... or UC-EMLP tags are available for marking the devices and can be printed as per customer requirements. In addition, the covers provide enough space for the use of freely chosen sticky labels such as SK 5.0 WH:REEL without concealing the LED diagnostic indicators. 106006_en_02 PHOENIX CONTACT 10 / 12 MINI MCR-2-UI-UI(-PT)(-C) 7 Configuration Standard configuration for devicesnot configured to order: Input 0...10 V, output 0...20 mA (all DIP switches in the "off" position; transmission error
2902037 价格&库存

很抱歉,暂时无法提供与“2902037”相匹配的价格&库存,您可以联系我们找货

免费人工找货