https://www.phoenixcontact.com/us/products/2902646
Power supply unit - TRIO-PS/1AC/5DC/10 - 2902646
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Primary-switched TRIO POWER power supply for DIN rail mounting, input: 1-phase, output: 5 V DC/10 A
Product Description
TRIO POWER power supplies with standard functionality
TRIO POWER is particularly suited to standard machine production, thanks to 1- and 3-phase versions up to 960 W. The wide-range input and the
international approval package enable worldwide use.
The robust metal housing, the high electric strength, and the wide temperature range ensure a high level of power supply reliability.
Key Commercial Data
Packing unit
1 pc
Weight per Piece (excluding packing)
800.0 g
Custom tariff number
85044030
Country of origin
China
Technical data
Dimensions
Width
40 mm
Height
130 mm
Depth
115 mm
Ambient conditions
Degree of protection
IP20
Ambient temperature (operation)
-25 °C ... 70 °C (> 55° C derating : 2.5%/K)
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Max. permissible relative humidity (operation)
≤ 95 % (at 25 °C, non-condensing)
Noise immunity
EN 61000-6-2:2005
Input data
03/13/2016 Page 1 / 5
https://www.phoenixcontact.com/us/products/2902646
Power supply unit - TRIO-PS/1AC/5DC/10 - 2902646
Technical data
Input data
Nominal input voltage range
100 V AC ... 240 V AC
Input voltage range
85 V AC ... 264 V AC (Derating < 90 V AC: 2.5 %/K)
Dielectric strength maximum
300 V AC
AC frequency range
45 Hz ... 65 Hz
Discharge current to PE
< 3.5 mA
Nominal power consumption
> 12 V DC, constant capacity restricted
Inrush surge current
< 30 A
Power failure bypass
> 40 ms (120 V AC)
> 180 ms (230 V AC)
Choice of suitable circuit breakers
6 A ... 16 A (Characteristics B, C, D, K)
Type of protection
Transient surge protection
Protective circuit/component
Varistor
Output data
Nominal output voltage
5 V DC ±1 %
Setting range of the output voltage (USet)
4.5 V DC ... 6 V DC (> 12 V DC, constant capacity restricted)
Nominal output current (IN)
10 A (-25°C ... 55°C)
Derating
55 °C ... 70 °C (2.5%/K)
Connection in parallel
Yes, for redundancy and increased capacity
Connection in series
Yes
Max. capacitive load
Unlimited
Active current limitation
Approx. 12 A (in the event of a short-circuit)
Control deviation
< 1 % (change in load, static 10 % ... 90 %)
< 2 % (change in load, dynamic 10 % ... 90 %)
< 0.1 % (change in input voltage ±10 %)
Residual ripple
< 60 mVPP
Output power
120 W
Typical response time
80 % (230 V AC)
Insulation voltage input/output
4 kV AC (type test)
2 kV AC (routine test)
Protection class
I
03/13/2016 Page 2 / 5
https://www.phoenixcontact.com/us/products/2902646
Power supply unit - TRIO-PS/1AC/5DC/10 - 2902646
Technical data
General
MTTF/ MTBF (IEC 61709, SN 29500)
> 500000 h
Mounting position
horizontal DIN rail NS 35, EN 60715
Assembly instructions
Can be aligned: Horizontally 0 mm, vertically 50 mm
Connection data, input
Connection method
Screw connection
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
14
Stripping length
9 mm
Screw thread
M2,5
Connection data, output
Connection method
Screw connection
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
14
Stripping length
9 mm
Screw thread
M2,5
Standards and Regulations
Electromagnetic compatibility
Conformance with EMC Directive 2004/108/EC
Shock
15g in all directions in acc. with IEC 60068-2-27
Noise immunity
EN 61000-6-2:2005
Standards/regulations
EN 61000-4-3
EN 61000-4-4
EN 61000-4-6
Standard – Electrical equipment of machines
EN 60204-1
Standard - Safety of transformers
EN 61558-2-17
Standard - Electrical safety
EN 60950-1/VDE 0805 (SELV)
EN 61558-2-17
Standard – Electronic equipment for use in electrical power installations
and their assembly into electrical power installations
EN 50178/VDE 0160 (PELV)
03/13/2016 Page 3 / 5
https://www.phoenixcontact.com/us/products/2902646
Power supply unit - TRIO-PS/1AC/5DC/10 - 2902646
Technical data
Standards and Regulations
Standard – Safety extra-low voltage
EN 60950-1 (SELV)
EN 60204 (PELV)
Standard - Safe isolation
DIN VDE 0100-410
Standard – Protection against shock currents, basic requirements for
protective separation in electrical equipment
EN 50178
Standard – Limitation of mains harmonic currents
EN 61000-3-2
UL approvals
UL/C-UL listed UL 508
UL/C-UL Recognized UL 60950
Vibration (operation)
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Low Voltage Directive
Conformance with LV directive 2006/95/EC
Rail applications
EN 50121-4
Classifications
eCl@ss
eCl@ss 4.0
27040702
eCl@ss 4.1
27040702
eCl@ss 5.0
27242213
eCl@ss 5.1
27049002
eCl@ss 6.0
27049002
eCl@ss 7.0
27049002
eCl@ss 8.0
27049002
eCl@ss 9.0
27040701
ETIM
ETIM 3.0
EC001039
ETIM 4.0
EC002540
ETIM 5.0
EC002540
UNSPSC
UNSPSC 6.01
30211502
UNSPSC 7.0901
39121004
UNSPSC 11
39121004
UNSPSC 12.01
39121004
UNSPSC 13.2
39121004
Approvals
Approvals
03/13/2016 Page 4 / 5
https://www.phoenixcontact.com/us/products/2902646
Power supply unit - TRIO-PS/1AC/5DC/10 - 2902646
Approvals
Approvals
EAC / EAC
Ex Approvals
Approvals submitted
Approval details
EAC
EAC
Drawings
Block diagram
L
N
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
03/13/2016 Page 5 / 5
很抱歉,暂时无法提供与“2902646”相匹配的价格&库存,您可以联系我们找货
免费人工找货