0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2902744

2902744

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    电机启动器,可反向 24VDC 电源 2.4A 42 ~ 550V 负载

  • 数据手册
  • 价格&库存
2902744 数据手册
https://www.phoenixcontact.com/us/products/2902744 Hybrid motor starter - ELR H51-IESSC-24DC500AC-2 - 2902744 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Short-circuit-proof hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 24 V DC input, 2.4 A output current, emergency stop function, and adjustable overload shutdown. Can only be used with EM-RD and EM-RI adapters or power distribution board. Your advantages  22.5 mm wide  Safety level according to IEC 61508-1: SIL 3, ISO 13849: PL e  Reduction in wiring  Long service life  Space saving  Adjustable current for bimetal function  Low-wear switching Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356674539 Weight per Piece (excluding packing) 400.000 g Custom tariff number 85371098 Country of origin Germany Technical data Dimensions Width 22.5 mm Height 160 mm Depth 114.5 mm 05/14/2019   Page 1 / 13 https://www.phoenixcontact.com/us/products/2902744 Hybrid motor starter - ELR H51-IESSC-24DC500AC-2 - 2902744 Technical data Ambient conditions Ambient temperature (operation) -25 °C ... 70 °C (observe derating) Ambient temperature (storage/transport) -40 °C ... 80 °C Degree of protection IP20 IP20 Device supply Rated control circuit supply voltage US 24 V DC Control supply voltage range 19.2 V DC ... 30 V DC Rated control supply current IS 40 mA Type of protection Surge protection Reverse polarity protection Input data Input name Control input right/left Rated actuating voltage UC 24 V DC Triggering voltage range 19.2 V DC ... 30 V DC Rated actuating current IC 5 mA Switching threshold 9.6 V (“0” signal) 19.2 V (“1” signal) Switching level < 5 V DC (For EMERGENCY STOP) Typical turn-off time < 30 ms Type of protection Reverse polarity protection Output data load output Output name AC output Rated operating voltage Ue 500 V AC Operating voltage range 42 V AC ... 550 V AC Mains frequency 50/60 Hz Load current range 180 mA ... 2.4 A (see to derating) Trigger characteristic in acc. with IEC 60947-4-2 Class 10A Cooling time 20 min. (for auto reset) Leakage current 0 mA Type of protection Surge protection Short-circuit protection Output data reply output Output name Acknowledge output Note Confirmation: floating change-over contact, signal contact Contact type 1 PDT 05/14/2019   Page 2 / 13 https://www.phoenixcontact.com/us/products/2902744 Hybrid motor starter - ELR H51-IESSC-24DC500AC-2 - 2902744 Technical data Output data reply output Switching capacity according to IEC 60947-5-1 3 A (230 V, AC15) 2 A (24 V, DC13) General Switching frequency ≤ 2 Hz (Load-dependent) Mounting position vertical (horizontal DIN rail, motor output below) Mounting type DIN rail mounting Assembly instructions alignable, for spacing see derating Operating mode 100% operating factor Maximum power dissipation 5.5 W Minimum power dissipation 0.88 W Operating voltage display Green LED Status display Yellow LED Indication Red LED Connection data 1 Connection name Control circuits Connection method Screw connection Stripping length 8 mm Screw thread M3 Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 Torque 0.5 Nm ... 0.6 Nm Connection data 2 Connection name Load circuit Connection method Screw connection Stripping length 8 mm Screw thread M3 Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 Torque 0.5 Nm ... 0.6 Nm UL data SCCR 100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault))) 5 kA (500 V AC (fuse: 20 A RK5 (standard fault))) FLA 2.4 A (500 V AC) 05/14/2019   Page 3 / 13 https://www.phoenixcontact.com/us/products/2902744 Hybrid motor starter - ELR H51-IESSC-24DC500AC-2 - 2902744 Technical data UL data Group installation 20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded) 30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded) Category code NLDX / NRNT Insulation characteristics Rated insulation voltage 500 V Rated surge voltage 6 kV Overvoltage category III Degree of pollution 2 Designation Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit Insulation Safe isolation (IEC 60947-1) at operating voltage ≤ 300 V AC Safe isolation (EN 50178) at operating voltage ≤ 300 V AC Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC Designation Isolation characteristics between the control input and control supply voltage to auxiliary circuit Insulation Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC Standards and Regulations Designation Standards/regulations Standards/regulations IEC 60947-1 EN 60947-4-2 IEC 61508 ISO 13849 ATEX # II (2) G [Ex e] [Ex d] [Ex px] # II (2) D [Ex t] [Ex p] Approvals/conformities Safety Integrity Level according to IEC 61508 ≤ 3 (Safe shutdown) 2 (Motor protection) Category acc. to EN ISO 13849 ≤ 3 (Safe shutdown) Performance level according to ISO 13849 e (Safe shutdown) ATEX # II (2) G [Ex e] [Ex d] [Ex px] # II (2) D [Ex t] [Ex p] EU-type examination certificate PTB 07 ATEX 3145 UL certificate NLDX.E228652 Environmental Product Compliance 05/14/2019   Page 4 / 13 https://www.phoenixcontact.com/us/products/2902744 Hybrid motor starter - ELR H51-IESSC-24DC500AC-2 - 2902744 Technical data Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings Block diagram Reset Autoreset Us T T MAN RES AUT Reset2 24 VDC & Error E R L L1 L2 L3 Logic µP Reset 24VDC 97 96 95 2/T1 6/T3 4/T2 Articles in set Fuse - FUSE-10X38-16A-GR - 2903126 Fuse, number: 10 Pcs., fuse type: Fuse (CC), nominal current: 16 A, tripping characteristic: super-fast blow (gR)     Classifications eCl@ss eCl@ss 5.0 27024002 eCl@ss 5.1 27024002 eCl@ss 6.0 27024002 eCl@ss 7.0 27024002 eCl@ss 8.0 27024002 eCl@ss 9.0 27370905 ETIM ETIM 2.0 EC001037 ETIM 3.0 EC001037 ETIM 4.0 EC001037 05/14/2019   Page 5 / 13 https://www.phoenixcontact.com/us/products/2902744 Hybrid motor starter - ELR H51-IESSC-24DC500AC-2 - 2902744 Classifications ETIM ETIM 5.0 EC001037 ETIM 6.0 EC001037 UNSPSC UNSPSC 6.01 30211915 UNSPSC 7.0901 39121514 UNSPSC 11 39121514 UNSPSC 12.01 39121514 UNSPSC 13.2 25173902 Accessories Accessories Assembly adapter Power distribution board - EM-CPS-225 - 1002634 ® Modular power distribution board with CrossLink interface, 125 A, 3-pos., touch-proof and protection against polarity reversal, width: 225 mm     Power distribution board - EM-CPS-405 - 1002635 ® Modular power distribution board with CrossLink interface, 125 A, 3-pos., touch-proof and protection against polarity reversal, width: 405 mm     Connection module - EM-CPS-TB3/63A - 1002633 Connection module with integrated spring-loaded terminals for cables from 1.5 to 16 mm², 3-pos., maximum 63 A     Bridge 05/14/2019   Page 6 / 13 https://www.phoenixcontact.com/us/products/2902744 Hybrid motor starter - ELR H51-IESSC-24DC500AC-2 - 2902744 Accessories Jumper - BRIDGE- 4-3M - 2901659 3-phase loop bridge for 4 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Cover Covering hood - BRIDGE COVER - 2906240 The BRIDGE COVER covering hood is used to cover unused plugs on the CONTACTRON bridge that may subsequently be used to extend the system. The hood can be used with the screw and Push-in version of the bridge.     Device marking Plastic label - US-EMLP (15X5) - 0828790 Plastic label, Card, white, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 15 x 5 mm     Plastic label - UC-EMLP (15X5) - 0819301 Plastic label, Sheet, white, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 15 x 5 mm     Loop bridge 05/14/2019   Page 7 / 13 https://www.phoenixcontact.com/us/products/2902744 Hybrid motor starter - ELR H51-IESSC-24DC500AC-2 - 2902744 Accessories Jumper - BRIDGE- 2 - 2900746 3-phase loop bridge for 2 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.     Jumper - BRIDGE- 3 - 2900747 3-phase loop bridge for 3 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.     Jumper - BRIDGE- 4 - 2900748 3-phase loop bridge for 4 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.     Jumper - BRIDGE- 5 - 2900749 3-phase loop bridge for 5 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.     Jumper - BRIDGE- 6 - 2900750 3-phase loop bridge for 6 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.     05/14/2019   Page 8 / 13 https://www.phoenixcontact.com/us/products/2902744 Hybrid motor starter - ELR H51-IESSC-24DC500AC-2 - 2902744 Accessories Jumper - BRIDGE- 7 - 2900751 3-phase loop bridge for 7 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.     Jumper - BRIDGE- 8 - 2900752 3-phase loop bridge for 8 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.     Jumper - BRIDGE- 9 - 2900753 3-phase loop bridge for 9 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.     Jumper - BRIDGE-10 - 2900754 3-phase loop bridge for 10 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.     Jumper - BRIDGE- 2-3M - 2901543 3-phase loop bridge for 2 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     05/14/2019   Page 9 / 13 https://www.phoenixcontact.com/us/products/2902744 Hybrid motor starter - ELR H51-IESSC-24DC500AC-2 - 2902744 Accessories Jumper - BRIDGE- 3-3M - 2901656 3-phase loop bridge for 3 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Jumper - BRIDGE- 5-3M - 2901545 3-phase loop bridge for 5 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Jumper - BRIDGE- 6-3M - 2901697 3-phase loop bridge for 6 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Jumper - BRIDGE- 7-3M - 2901698 3-phase loop bridge for 7 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Jumper - BRIDGE- 8-3M - 2901700 3-phase loop bridge for 8 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     05/14/2019   Page 10 / 13 https://www.phoenixcontact.com/us/products/2902744 Hybrid motor starter - ELR H51-IESSC-24DC500AC-2 - 2902744 Accessories Jumper - BRIDGE- 9-3M - 2901701 3-phase loop bridge for 9 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Jumper - BRIDGE-10-3M - 2901702 3-phase loop bridge for 10 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Jumper - BRIDGE- 2-1M - 2901542 3-phase loop bridge for 2 modules from the CONTACTRON family with screw connection and 22.5 mm housing width, 1 m long connecting cable, without ferrules.     Jumper - BRIDGE- 3-1M - 2901655 3-phase loop bridge for 3 modules from the CONTACTRON family with screw connection and 22.5 mm housing width, 1 m long connecting cable, without ferrules.     Jumper - BRIDGE- 4-1M - 2901658 3-phase loop bridge for 4 modules from the CONTACTRON family with screw connection and 22.5 mm housing width, 1 m long connecting cable, without ferrules.     05/14/2019   Page 11 / 13 https://www.phoenixcontact.com/us/products/2902744 Hybrid motor starter - ELR H51-IESSC-24DC500AC-2 - 2902744 Accessories Jumper - BRIDGE- 5-1M - 2901544 3-phase loop bridge for 5 modules from the CONTACTRON family with screw connection and 22.5 mm housing width, 1 m long connecting cable, without ferrules.     Jumper - BRIDGE- 6-1M - 2901649 3-phase loop bridge for 6 modules in the CONTACTRON family with 1 m long connecting cable without ferrules, 22.5 mm housing width.     Necessary add-on products Adapter - EM RD-ADAPTER - 2902747 Adapter for mounting short circuit-proof hybrid motor starters of type ELR-H51 ... on 35 mm DIN rails.     Adapter - EM RI-ADAPTER COMPACT - 2902748 Adapter for mounting short circuit-proof hybrid motor starters of type ELR-H51 ... on 60 mm power busbars. Compact design with 160 mm design height.     Adapter - EM RI-ADAPTER CLASSIC - 2902831 Adapter for mounting short-circuit proof hybrid motor starters of type ELR-H51 ... on 60 mm power busbars. Classic design with 200 mm design height.     05/14/2019   Page 12 / 13 https://www.phoenixcontact.com/us/products/2902744 Hybrid motor starter - ELR H51-IESSC-24DC500AC-2 - 2902744 Accessories Spare parts Fuse - FUSE-10X38-30A-MR - 2903119 Fuse, number: 10 Pcs., fuse type: Fuse (CC), nominal current: 30 A, tripping characteristic: fast-blow     Fuse - FUSE-10X38-20A-GR - 2903384 Fuse, number: 10 Pcs., fuse type: Fuse (CC), nominal current: 20 A, tripping characteristic: super-fast blow (gR)     Fuse - FUSE-10X38-16A-GR - 2903126 Fuse, number: 10 Pcs., fuse type: Fuse (CC), nominal current: 16 A, tripping characteristic: super-fast blow (gR)     Phoenix Contact 2019 © - all rights reserved http://www.phoenixcontact.com 05/14/2019   Page 13 / 13
2902744 价格&库存

很抱歉,暂时无法提供与“2902744”相匹配的价格&库存,您可以联系我们找货

免费人工找货