0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2902832

2902832

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    FREQ TRANS MINI MCR-SL-F-UI-NC

  • 数据手册
  • 价格&库存
2902832 数据手册
https://www.phoenixcontact.com/us/products/2902832 Frequency transducer - MINI MCR-SL-F-UI-NC - 2902832 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) The configurable frequency transducer is suitable for the connection of NAMUR proximity sensors as well as for sensors with NPN and PNP outputs. Configurable via DIP switch and teach-in wheel. Screw connection, standard configuration. Product Description The configurable 3-way isolated frequency transducer is suitable for the connection of NAMUR proximity sensors (IEC 60947-5-6 and EN 50227) as well as for sensors with NPN and PNP outputs that generate a frequency signal. The measured values are converted into a linear current or voltage signal. The device is configured via DIP switches. Alternatively, the frequency range can be configured with extended options via the teach-in wheel. The measuring transducer supports fault monitoring. Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356682367 Weight per Piece (excluding packing) 100.000 g Custom tariff number 85437090 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 6.2 mm Height 93.1 mm 11/08/2019   Page 1 / 9 https://www.phoenixcontact.com/us/products/2902832 Frequency transducer - MINI MCR-SL-F-UI-NC - 2902832 Technical data Dimensions Depth 102.5 mm Ambient conditions Ambient temperature (operation) -20 °C ... 65 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 5 % ... 95 % (non-condensing) Degree of protection IP20 Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Input data Frequency input Frequency input Configurable/programmable Yes Frequency measuring range 0.002 Hz ... 20 kHz (DIP switch) Available input sources NPN/PNP transistor outputs NAMUR initiators Floating relay contact (dry contact) Max. input amplitude 30 V (incl. DC voltage) Output data Output name Voltage output / current output Number of outputs 1 Configurable/programmable Yes Voltage output signal 0 V ... 5 V 1 V ... 5 V 0 V ... 10 V 10 V ... 0 V Current output signal 0 mA ... 20 mA 4 mA ... 20 mA 20 mA ... 0 mA 20 mA ... 4 mA Max. output voltage approx. 12.3 V Max. output current 24.6 mA Load/output load voltage output ≥ 10 kΩ Load/output load current output 500 Ω (at 20 mA) Ripple < 20 mVPP < 20 mVPP (at 500 Ω) Step response (0–99%) < 35 ms (At f > 500 Hz) Power supply 11/08/2019   Page 2 / 9 https://www.phoenixcontact.com/us/products/2902832 Frequency transducer - MINI MCR-SL-F-UI-NC - 2902832 Technical data Power supply Supply voltage range 9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715)) Typical current consumption < 28 mA (at IOUT = 20 mA, 24 V DC, load 500 Ω) Power consumption < 800 mW (at IOUT = 20 mA, 9.6 V DC, load 500 Ω) Connection data Connection method Screw connection Stripping length 12 mm Screw thread M3 Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 26 ... 12 General No. of channels 1 Transmission error in the set measuring range 0.1 % Maximum temperature coefficient 0.01 %/K Status display LED red Operating elements Press/slide button Protective circuit Transient protection Electrical isolation Basic insulation according to EN 61010 Overvoltage category II Degree of pollution 2 Rated insulation voltage 50 V AC/DC Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.) Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Color green Housing material PBT Mounting position any Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA/Canada UL 508 Listed Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, Group IIC 11/08/2019   Page 3 / 9 https://www.phoenixcontact.com/us/products/2902832 Frequency transducer - MINI MCR-SL-F-UI-NC - 2902832 Technical data General Certificate of classification DNV GL 14085-15HH Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2 EMC data Designation Electromagnetic RF field Standards/regulations EN 61000-4-3 Typical deviation from the measuring range final value 0.1 % Designation Fast transients (burst) Standards/regulations EN 61000-4-4 Typical deviation from the measuring range final value 2% Designation Conducted interferences Standards/regulations EN 61000-4-6 Typical deviation from the measuring range final value 0.3 % Standards and Regulations Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Standards/regulations EN 61000-4-2 Designation Electromagnetic RF field Standards/regulations EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 Designation Conducted interferences Standards/regulations EN 61000-4-6 Electrical isolation Basic insulation according to EN 61010 Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA/Canada UL 508 Listed Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, Group IIC Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2 Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 11/08/2019   Page 4 / 9 https://www.phoenixcontact.com/us/products/2902832 Frequency transducer - MINI MCR-SL-F-UI-NC - 2902832 Technical data Environmental Product Compliance For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings Block diagram 11/08/2019   Page 5 / 9 https://www.phoenixcontact.com/us/products/2902832 Frequency transducer - MINI MCR-SL-F-UI-NC - 2902832 Pictogram Classifications eCl@ss eCl@ss 4.0 27210100 eCl@ss 4.1 27210100 eCl@ss 5.0 27210100 eCl@ss 5.1 27210100 eCl@ss 6.0 27210100 eCl@ss 7.0 27210120 eCl@ss 8.0 27210120 eCl@ss 9.0 27210120 ETIM ETIM 4.0 EC002653 ETIM 5.0 EC002653 ETIM 6.0 EC002653 ETIM 7.0 EC002653 UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 39121008 11/08/2019   Page 6 / 9 https://www.phoenixcontact.com/us/products/2902832 Frequency transducer - MINI MCR-SL-F-UI-NC - 2902832 Approvals Approvals Approvals GL / UL Listed / cUL Listed / cULus Listed Ex Approvals ATEX / UL Listed / cUL Listed / EAC Ex / cULus Listed Approval details GL    https://approvalfinder.dnvgl.com/  14085-15 HH UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 238705 cUL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 238705 cULus Listed       Accessories Accessories DIN rail connector DIN rail bus connectors - ME 6,2 TBUS-2 1,5/5-ST-3,81 GN - 2869728 DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold-plated contacts, 5-pos.     11/08/2019   Page 7 / 9 https://www.phoenixcontact.com/us/products/2902832 Frequency transducer - MINI MCR-SL-F-UI-NC - 2902832 Accessories Evaluation unit Monitoring module - MINI MCR-SL-FM-RC-NC - 2902961 The fault monitoring module is used to evaluate and report group errors from the fault monitoring system and to monitor the supply voltages. The error is reported via an N/O contact. Screw connection, standard configuration.     Monitoring module - MINI MCR-SL-FM-RC-SP-NC - 2902962 The fault monitoring module is used to evaluate and report group errors from the fault monitoring system and monitor supply voltages. Spring-cage connection, standard configuration. Replacement part: 2904508 MINI MCR-2-FM-RC-PT.     Multiplexer Multiplexer - MINI MCR-SL-MUX-V8-FLK 16 - 2811815 MINI analog multiplexer, generates one analog output from 8 analog input signals, for MINI analog module with screw connection.     Power module Power terminal block - MINI MCR-SL-PTB-FM - 2902958 The MINI MCR-SL-PTB-FM(-SP) power terminal block is used to supply the supply voltage to the DIN rail connector. The FM power terminal block offers the additional function of monitoring in combination with the fault monitoring module. Screw connection.     11/08/2019   Page 8 / 9 https://www.phoenixcontact.com/us/products/2902832 Frequency transducer - MINI MCR-SL-F-UI-NC - 2902832 Accessories Power terminal block - MINI MCR-SL-PTB-FM-SP - 2902959 The MINI MCR-SL-PTB-FM(-SP) feed-in terminal is used to feed in the supply voltage to the DIN rail connector. The FM feed-in terminal offers an additional function: monitoring. Spring-cage connection. Replacement part: 2902067 MINI MCR-2-PTB-PT.     Power supply Power supply unit - MINI-SYS-PS-100-240AC/24DC/1.5 - 2866983 Primary-switched MINI POWER supply for DIN rail mounting, input: 1-phase, output: 24 V DC/1.5 A     System adapter System adapter - MINI MCR-SL-V8-FLK 16-A - 2811268 Eight MINI analog signal converters with screw connection method can be connected to a control system using a system adapter and system cabling with a minimum of wiring and very low error risk.     Phoenix Contact 2019 © - all rights reserved http://www.phoenixcontact.com 11/08/2019   Page 9 / 9
2902832 价格&库存

很抱歉,暂时无法提供与“2902832”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2902832

库存:19