https://www.phoenixcontact.com/us/products/2902833
Frequency transducer - MINI MCR-SL-F-UI-SP-NC - 2902833
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://download.phoenixcontact.com)
The configurable frequency transducer is suitable for the connection of NAMUR proximity sensors as well as for
sensors with NPN and PNP outputs. Configurable via DIP switch and teach-in wheel. Spring-cage connection,
standard configuration.
The figure shows a version with a
screw connection
Product description
The configurable 3-way isolated frequency transducer is suitable for the connection of NAMUR proximity sensors (IEC 60947-5-6 and EN 50227) as well
as for sensors with NPN and PNP outputs that generate a frequency signal.
The measured values are converted into a linear current or voltage signal.
The device is configured via DIP switches. Alternatively, the frequency range can be configured with extended options via the teach-in wheel. The
measuring transducer supports fault monitoring.
Key commercial data
Packing unit
1 PCE
GTIN
Custom tariff number
85437090
Country of origin
GERMANY
Technical data
Note:
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
6.2 mm
Height
93.1 mm
Depth
102.5 mm
Ambient conditions
Ambient temperature (operation)
-20 °C ... 65 °C
29.08.2013 Page 1 / 7
https://www.phoenixcontact.com/us/products/2902833
Frequency transducer - MINI MCR-SL-F-UI-SP-NC - 2902833
Technical data
Ambient conditions
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Degree of protection
IP20
Input data
Frequency input
Frequency input
Configurable/programmable
Yes
Frequency measuring range
0.002 Hz ... 20 kHz (DIP switch)
Available input sources
NPN/PNP transistor outputs
NAMUR initiators
Floating relay contact (dry contact)
Max. input amplitude
30 V (incl. DC voltage)
A/D conversion time
10 ms (At f > 500 Hz)
Output data
Output name
Voltage output
Configurable/programmable
Yes
Voltage output signal
0 V ... 5 V
1 V ... 5 V
0 V ... 10 V
10 V ... 0 V
Current output signal
0 mA ... 20 mA
4 mA ... 20 mA
20 mA ... 0 mA
20 mA ... 4 mA
Max. output voltage
approx. 12.3 V
Max. output current
24.6 mA
Load/output load voltage output
≥ 10 kΩ
Load/output load current output
500 Ω (at 20 mA)
Power supply
Supply voltage range
9.6 V DC ... 30 V DC (The T connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN,
Order No. 2869728) can be used to bridge the supply voltage. It can be
snapped onto a 35 mm DIN rail according to EN 60715))
Typical current consumption
< 28 mA (at IOUT = 20 mA, 24 V DC, load 500 Ω)
Power consumption
< 800 mW (at IOUT = 20 mA, 9.6 V DC, load 500 Ω)
Connection data
Connection method
Spring-cage conn.
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
2.5 mm²
29.08.2013 Page 2 / 7
https://www.phoenixcontact.com/us/products/2902833
Frequency transducer - MINI MCR-SL-F-UI-SP-NC - 2902833
Technical data
Connection data
Conductor cross section stranded min.
0.2 mm²
Conductor cross section stranded max.
2.5 mm²
Conductor cross section AWG/kcmil min.
24
Conductor cross section AWG/kcmil max
12
Stripping length
8 mm
General
Maximum temperature coefficient
0.01 %/K
Status display
LED red
Operating elements
Press/slide button
Protective circuit
Transient protection
Electrical isolation
Basic insulation according to EN 61010
Surge voltage category
II
Pollution degree
2
Rated insulation voltage
50 V AC/DC
Test voltage, input/output/supply
1.5 kV (50 Hz, 1 min.)
Electromagnetic compatibility
Conformance with EMC Directive 2004/108/EC
Noise emission
EN 61000-6-4
Noise immunity
EN 61000-6-2 When being exposed to interference, there may be minimal
deviations.
Color
green
Housing material
PBT
Mounting position
Any
Assembly instructions
The T connector can be used to bridge the supply voltage. It can be
snapped onto a 35 mm DIN rail according to EN 60715.
Conformance
CE-compliant
ATEX
II 3 G Ex nA IIC T4 Gc X
UL, USA / Canada
508 listed
Class I, Div. 2, Groups A, B, C, D T5 applied for
GL
GL applied for
EMC data
Name
Electromagnetic RF field
Standards/regulations
EN 61000-4-3
Typical deviation from the measuring range final value
0.1 %
Name
Fast transients (burst)
Standards/regulations
EN 61000-4-4
Typical deviation from the measuring range final value
2%
Name
Conducted interferences
29.08.2013 Page 3 / 7
https://www.phoenixcontact.com/us/products/2902833
Frequency transducer - MINI MCR-SL-F-UI-SP-NC - 2902833
Technical data
EMC data
Standards/regulations
EN 61000-4-6
Typical deviation from the measuring range final value
0.3 %
Classifications
ETIM
ETIM 3.0
EC001446
ETIM 4.0
EC001485
ETIM 5.0
EC001485
UNSPSC
UNSPSC 11
39121008
UNSPSC 12.01
39121008
UNSPSC 13.2
39121008
UNSPSC 6.01
30211506
UNSPSC 7.0901
39121008
eCl@ss
eCl@ss 4.0
27200206
eCl@ss 4.1
27200206
eCl@ss 5.0
27200206
eCl@ss 5.1
27200206
eCl@ss 6.0
27200206
eCl@ss 7.0
27200206
eCl@ss 8.0
27200206
Approvals
Approvals
Approvals
UL Listed / cUL Listed / cULus Listed
Ex Approvals
Approvals submitted
29.08.2013 Page 4 / 7
https://www.phoenixcontact.com/us/products/2902833
Frequency transducer - MINI MCR-SL-F-UI-SP-NC - 2902833
Approvals
Approval details
UL Listed
cUL Listed
cULus Listed
Accessories
Accessories
Power terminal block - MINI MCR-SL-PTB-FM - 2902958
The MINI MCR-SL-PTB-FM(-SP) power terminal block is used to supply the supply voltage to the T-connector. The FM
power terminal block offers the additional function of monitoring in combination with the fault monitoring module. Screw
connection.
Power terminal block - MINI MCR-SL-PTB-FM-SP - 2902959
The MINI MCR-SL-PTB-FM(-SP) power terminal block is used to supply the supply voltage to the T-connector. The FM
power terminal block offers the additional function of monitoring in combination with the fault monitoring module. Springcage connection.
Monitoring module - MINI MCR-SL-FM-RC-NC - 2902961
The fault monitoring module is used to evaluate and report group errors from the fault monitoring system and to monitor
the supply voltages. The error is reported via an N/O contact. Screw connection, standard configuration.
29.08.2013 Page 5 / 7
https://www.phoenixcontact.com/us/products/2902833
Frequency transducer - MINI MCR-SL-F-UI-SP-NC - 2902833
Accessories
Monitoring module - MINI MCR-SL-FM-RC-SP-NC - 2902962
The fault monitoring module is used to evaluate and report group errors from the fault monitoring system and to monitor
the supply voltages. The error is reported via an N/O contact. Spring-cage connection, standard configuration.
Electronic housing - ME 6,2 TBUS-2 1,5/5-ST-3,81 GN - 2869728
DIN rail connector for DIN rail mounting. Universal for T-BUS housing. Gold-plated contacts, 5-pos.
Power supply unit - MINI-SYS-PS-100-240AC/24DC/1.5 - 2866983
DIN rail power supply unit, primary-switched mode, slim design, output: 24 V DC / 1.5 A
System adapter - MINI MCR-SL-V8-FLK 16-A - 2811268
Eight MINI analog signal converters with screw connection method can be connected to a control system using a system
adapter and system cabling with a minimum of wiring and very low error risk.
Multiplexer - MINI MCR-SL-MUX-V8-FLK 16 - 2811815
MINI analog multiplexer, generates one analog output from 8 analog input signals, for MINI analog module with screw
connection.
Drawings
29.08.2013 Page 6 / 7
https://www.phoenixcontact.com/us/products/2902833
Frequency transducer - MINI MCR-SL-F-UI-SP-NC - 2902833
Pictogram
NPN
PNP
IN
U,I
OUT
FM
POWER
© Phoenix Contact 2013 - all rights reserved
http://www.phoenixcontact.com
29.08.2013 Page 7 / 7