0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2902833

2902833

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    Module

  • 描述:

    SENSOR ANALOG REMOTE MODULE

  • 数据手册
  • 价格&库存
2902833 数据手册
https://www.phoenixcontact.com/us/products/2902833 Frequency transducer - MINI MCR-SL-F-UI-SP-NC - 2902833 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://download.phoenixcontact.com) The configurable frequency transducer is suitable for the connection of NAMUR proximity sensors as well as for sensors with NPN and PNP outputs. Configurable via DIP switch and teach-in wheel. Spring-cage connection, standard configuration. The figure shows a version with a screw connection Product description The configurable 3-way isolated frequency transducer is suitable for the connection of NAMUR proximity sensors (IEC 60947-5-6 and EN 50227) as well as for sensors with NPN and PNP outputs that generate a frequency signal. The measured values are converted into a linear current or voltage signal. The device is configured via DIP switches. Alternatively, the frequency range can be configured with extended options via the teach-in wheel. The measuring transducer supports fault monitoring.     Key commercial data Packing unit 1 PCE GTIN Custom tariff number 85437090 Country of origin GERMANY Technical data Note: Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 6.2 mm Height 93.1 mm Depth 102.5 mm Ambient conditions Ambient temperature (operation) -20 °C ... 65 °C 29.08.2013   Page 1 / 7 https://www.phoenixcontact.com/us/products/2902833 Frequency transducer - MINI MCR-SL-F-UI-SP-NC - 2902833 Technical data Ambient conditions Ambient temperature (storage/transport) -40 °C ... 85 °C Degree of protection IP20 Input data Frequency input Frequency input Configurable/programmable Yes Frequency measuring range 0.002 Hz ... 20 kHz (DIP switch) Available input sources NPN/PNP transistor outputs NAMUR initiators Floating relay contact (dry contact) Max. input amplitude 30 V (incl. DC voltage) A/D conversion time 10 ms (At f > 500 Hz) Output data Output name Voltage output Configurable/programmable Yes Voltage output signal 0 V ... 5 V 1 V ... 5 V 0 V ... 10 V 10 V ... 0 V Current output signal 0 mA ... 20 mA 4 mA ... 20 mA 20 mA ... 0 mA 20 mA ... 4 mA Max. output voltage approx. 12.3 V Max. output current 24.6 mA Load/output load voltage output ≥ 10 kΩ Load/output load current output 500 Ω (at 20 mA) Power supply Supply voltage range 9.6 V DC ... 30 V DC (The T connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715)) Typical current consumption < 28 mA (at IOUT = 20 mA, 24 V DC, load 500 Ω) Power consumption < 800 mW (at IOUT = 20 mA, 9.6 V DC, load 500 Ω) Connection data Connection method Spring-cage conn. Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² 29.08.2013   Page 2 / 7 https://www.phoenixcontact.com/us/products/2902833 Frequency transducer - MINI MCR-SL-F-UI-SP-NC - 2902833 Technical data Connection data Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 12 Stripping length 8 mm General Maximum temperature coefficient 0.01 %/K Status display LED red Operating elements Press/slide button Protective circuit Transient protection Electrical isolation Basic insulation according to EN 61010 Surge voltage category II Pollution degree 2 Rated insulation voltage 50 V AC/DC Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.) Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Color green Housing material PBT Mounting position Any Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA / Canada 508 listed Class I, Div. 2, Groups A, B, C, D T5 applied for GL GL applied for EMC data Name Electromagnetic RF field Standards/regulations EN 61000-4-3 Typical deviation from the measuring range final value 0.1 % Name Fast transients (burst) Standards/regulations EN 61000-4-4 Typical deviation from the measuring range final value 2% Name Conducted interferences 29.08.2013   Page 3 / 7 https://www.phoenixcontact.com/us/products/2902833 Frequency transducer - MINI MCR-SL-F-UI-SP-NC - 2902833 Technical data EMC data Standards/regulations EN 61000-4-6 Typical deviation from the measuring range final value 0.3 % Classifications ETIM ETIM 3.0 EC001446 ETIM 4.0 EC001485 ETIM 5.0 EC001485 UNSPSC UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 39121008 UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 eCl@ss eCl@ss 4.0 27200206 eCl@ss 4.1 27200206 eCl@ss 5.0 27200206 eCl@ss 5.1 27200206 eCl@ss 6.0 27200206 eCl@ss 7.0 27200206 eCl@ss 8.0 27200206 Approvals Approvals Approvals UL Listed / cUL Listed / cULus Listed Ex Approvals Approvals submitted 29.08.2013   Page 4 / 7 https://www.phoenixcontact.com/us/products/2902833 Frequency transducer - MINI MCR-SL-F-UI-SP-NC - 2902833 Approvals Approval details UL Listed  cUL Listed  cULus Listed  Accessories Accessories Power terminal block - MINI MCR-SL-PTB-FM - 2902958 The MINI MCR-SL-PTB-FM(-SP) power terminal block is used to supply the supply voltage to the T-connector. The FM power terminal block offers the additional function of monitoring in combination with the fault monitoring module. Screw connection.     Power terminal block - MINI MCR-SL-PTB-FM-SP - 2902959 The MINI MCR-SL-PTB-FM(-SP) power terminal block is used to supply the supply voltage to the T-connector. The FM power terminal block offers the additional function of monitoring in combination with the fault monitoring module. Springcage connection.     Monitoring module - MINI MCR-SL-FM-RC-NC - 2902961 The fault monitoring module is used to evaluate and report group errors from the fault monitoring system and to monitor the supply voltages. The error is reported via an N/O contact. Screw connection, standard configuration.     29.08.2013   Page 5 / 7 https://www.phoenixcontact.com/us/products/2902833 Frequency transducer - MINI MCR-SL-F-UI-SP-NC - 2902833 Accessories Monitoring module - MINI MCR-SL-FM-RC-SP-NC - 2902962 The fault monitoring module is used to evaluate and report group errors from the fault monitoring system and to monitor the supply voltages. The error is reported via an N/O contact. Spring-cage connection, standard configuration.     Electronic housing - ME 6,2 TBUS-2 1,5/5-ST-3,81 GN - 2869728 DIN rail connector for DIN rail mounting. Universal for T-BUS housing. Gold-plated contacts, 5-pos.     Power supply unit - MINI-SYS-PS-100-240AC/24DC/1.5 - 2866983 DIN rail power supply unit, primary-switched mode, slim design, output: 24 V DC / 1.5 A     System adapter - MINI MCR-SL-V8-FLK 16-A - 2811268 Eight MINI analog signal converters with screw connection method can be connected to a control system using a system adapter and system cabling with a minimum of wiring and very low error risk.     Multiplexer - MINI MCR-SL-MUX-V8-FLK 16 - 2811815 MINI analog multiplexer, generates one analog output from 8 analog input signals, for MINI analog module with screw connection.     Drawings 29.08.2013   Page 6 / 7 https://www.phoenixcontact.com/us/products/2902833 Frequency transducer - MINI MCR-SL-F-UI-SP-NC - 2902833 Pictogram NPN PNP IN U,I OUT FM POWER © Phoenix Contact 2013 - all rights reserved http://www.phoenixcontact.com 29.08.2013   Page 7 / 7
2902833 价格&库存

很抱歉,暂时无法提供与“2902833”相匹配的价格&库存,您可以联系我们找货

免费人工找货