https://www.phoenixcontact.com/us/products/2902851
Thermocouple measuring transducer - MINI MCR-TC-UI-NC - 2902851
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://download.phoenixcontact.com)
Configurable temperature transducer for the connection of thermocouples. Can be configured via DIP switches
or, with extended functionality, using the software. Screw connection, standard configuration.
Product description
The configurable temperature transducer with 3-way isolation is suitable for the connection of thermocouples.
The measured values are converted into a linear current or voltage signal.
The device can either be configured via DIP switches or, with extended functionality, via the S port using the software (FDT/DTM). The measuring
transducer supports fault monitoring.
Key commercial data
Packing unit
1 PCE
GTIN
Custom tariff number
85437090
Country of origin
GERMANY
Technical data
Note:
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
6.2 mm
Height
93.1 mm
Depth
102.5 mm
Ambient conditions
29.08.2013 Page 1 / 7
https://www.phoenixcontact.com/us/products/2902851
Thermocouple measuring transducer - MINI MCR-TC-UI-NC - 2902851
Technical data
Ambient conditions
Ambient temperature (operation)
-20 °C ... 65 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Degree of protection
IP20
Input data
Configurable/programmable
Yes
Sensor types that can be used (TC)
B, E, J, K, N, R, S, T, L, U, A-1, A-2, A-3, M, L
Temperature measuring range
-250 °C ... 2500 °C (Range depending on the sensor type)
Output data
Configurable/programmable
Yes
Voltage output signal
0 V ... 10 V
10 V ... 0 V
0 V ... 5 V
1 V ... 5 V
Current output signal
0 mA ... 20 mA
4 mA ... 20 mA
20 mA ... 0 mA
20 mA ... 4 mA
Max. output voltage
approx. 12.3 V
Max. output current
24.6 mA
Load/output load voltage output
≥ 10 kΩ
Load/output load current output
< 500 Ω (at 20 mA)
Power supply
Supply voltage range
9.6 V DC ... 30 V DC (The T connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN,
Order No. 2869728) can be used to bridge the supply voltage. It can be
snapped onto a 35 mm DIN rail according to EN 60715))
Typical current consumption
< 27 mA (at 24 V DC)
Power consumption
≤ 700 mW (at IOUT = 20 mA, 9.6 V DC, load 500 Ω)
Connection data
Connection method
Screw connection
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section stranded min.
0.2 mm²
Conductor cross section stranded max.
2.5 mm²
Conductor cross section AWG/kcmil min.
26
Conductor cross section AWG/kcmil max
12
Stripping length
12 mm
29.08.2013 Page 2 / 7
https://www.phoenixcontact.com/us/products/2902851
Thermocouple measuring transducer - MINI MCR-TC-UI-NC - 2902851
Technical data
Connection data
Screw thread
M3
General
Maximum temperature coefficient
≤ 0.01 %/K
Cold point error, max.
很抱歉,暂时无法提供与“2902851”相匹配的价格&库存,您可以联系我们找货