2903144

2903144

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    TRIO-PS-2G/1AC/24DC/5/B+D

  • 数据手册
  • 价格&库存
2903144 数据手册
https://www.phoenixcontact.com/in/products/2903144 Power supply unit - TRIO-PS-2G/1AC/24DC/5/B+D - 2903144 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 1-phase, output: 24 V DC/5 A Product Description TRIO POWER power supplies for more stringent EMC requirements in shipbuilding The TRIO POWER power supply range with Push-in connection has been perfected for use in shipbuilding. All functions and the space-saving design of the single and three-phase modules are optimally tailored to the stringent requirements. Under challenging ambient conditions, the power supply units, which feature an extremely robust electrical and mechanical design, ensure the reliable supply of all loads. Your advantages  Can be used on the bridge of a ship in accordance with EN 60945  Increase system availability, thanks to dynamic boost with 150% of the nominal current for five seconds  Maximum flexibility due to the wide temperature range from -25°C to +70°C and device startup at -40°C  Electrically robust, thanks to high electric strength  Mechanically robust, thanks to high vibration and shock resistance  Save time and costs, thanks to the Push-in connection and narrow design Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356726955 Weight per Piece (excluding packing) 572.840 g Custom tariff number 85044030 Country of origin China Technical data Dimensions Width 35 mm Height 130 mm Depth 115 mm 06/17/2020   Page 1 / 9 https://www.phoenixcontact.com/in/products/2903144 Power supply unit - TRIO-PS-2G/1AC/24DC/5/B+D - 2903144 Technical data Dimensions Installation distance right/left 0 mm / 0 mm Installation distance top/bottom 50 mm / 50 mm Ambient conditions Degree of protection IP20 Inflammability class in acc. with UL 94 (housing / terminal blocks) V0 Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) Ambient temperature (storage/transport) -40 °C ... 85 °C Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing) Climatic class 3K3 (in acc. with EN 60721) Degree of pollution 2 Installation height ≤ 5000 m (> 2000 m, observe derating) Input data Nominal input voltage range 100 V AC ... 240 V AC 110 V DC ... 250 V DC Input voltage range 100 V AC ... 240 V AC -15 % ... +10 % 99 V DC ... 275 V DC Dielectric strength maximum ≤ 300 V AC 15 s AC frequency range 50 Hz ... 60 Hz ±5 Hz Frequency range (fN) 50 Hz ... 60 Hz ±10 % Discharge current to PE < 0.25 mA Current consumption 2.2 A (100 V AC) 1.9 A (120 V AC) 1.1 A (230 V AC) 1.1 A (240 V AC) Nominal power consumption 272 VA Inrush current ≤ 16 A (typical) Mains buffering time typ. 20 ms (120 V AC) typ. 100 ms (230 V AC) Input fuse 6.3 A (internal (device protection)) Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K) Power factor (cos phi) 0.5 Type of protection Transient surge protection Protective circuit/component Varistor Output data Nominal output voltage 24 V DC ±1 % Setting range of the output voltage (USet) 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted) Nominal output current (IN) 5A Dynamic Boost (IDyn.Boost) 7.5 A (5 s) Derating > 60 °C ... 70 °C (2.5%/K) 06/17/2020   Page 2 / 9 https://www.phoenixcontact.com/in/products/2903144 Power supply unit - TRIO-PS-2G/1AC/24DC/5/B+D - 2903144 Technical data Output data Connection in parallel Yes, for redundancy and increased capacity Connection in series yes Feedback voltage resistance ≤ 35 V DC Protection against overvoltage at the output (OVP) ≤ 30 V DC Control deviation < 1 % (change in load, static 10 % ... 90 %) < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz) < 0.1 % (change in input voltage ±10 %) Residual ripple < 50 mVPP (with nominal values) Output power 120 W Typical response time 3380000 h (25 °C) > 1970000 h (40 °C) > 900000 h (60 °C) Insulation voltage input/output 3 kV AC (type test) 1.5 kV AC (routine test) Degree of protection IP20 Protection class II (in closed control cabinet) Inflammability class in acc. with UL 94 (housing / terminal blocks) V0 Mounting position horizontal DIN rail NS 35, EN 60715 Assembly instructions alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm Connection data, input Connection method Push-in connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 4 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 Stripping length 10 mm Connection data, output Connection method Push-in connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 4 mm² Conductor cross section flexible min. 0.2 mm² 06/17/2020   Page 3 / 9 https://www.phoenixcontact.com/in/products/2903144 Power supply unit - TRIO-PS-2G/1AC/24DC/5/B+D - 2903144 Technical data Connection data, output Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 Stripping length 8 mm Connection data for signaling Connection method Push-in connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 16 Stripping length 8 mm Standards EMC requirements for noise immunity EN 61000-6-1 EN 61000-6-2 EMC requirements for noise emission EN 61000-6-3 EN 61000-6-4 Standard - Safety of transformers EN 61558-2-16 (air clearances and creepage distances only) Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV) Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV) Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV) Standard - Safe isolation DIN VDE 0100-410 Standard – Limitation of mains harmonic currents EN 61000-3-2 Mains variation/undervoltage Semi F47-0706 Rail applications EN 50121-4 Conformance/approvals UL approvals UL Listed UL 508 UL/C-UL Recognized UL 60950-1 Shipbuilding approval DNV GL (EMC B) IEC 60945 EMC data Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC Electrostatic discharge EN 61000-4-2 Contact discharge 6 kV (Test Level 4) Discharge in air 8 kV (Test Level 4) Electromagnetic HF field EN 61000-4-3 06/17/2020   Page 4 / 9 https://www.phoenixcontact.com/in/products/2903144 Power supply unit - TRIO-PS-2G/1AC/24DC/5/B+D - 2903144 Technical data EMC data Frequency range 80 MHz ... 1 GHz Test field strength 10 V/m (Test Level 3) Frequency range 1 GHz ... 2 GHz Test field strength 10 V/m (Test Level 3) Frequency range 2 GHz ... 3 GHz Test field strength 10 V/m (Test Level 3) Comments Criterion A Fast transients (burst) EN 61000-4-4 Input 4 kV (Test Level 4 - asymmetrical) Output 2 kV (Test Level 3 - asymmetrical) Signal 1 kV (Test Level 2 - asymmetrical) Comments Criterion A Surge voltage load (surge) EN 61000-4-5 Input 2 kV (Test Level 3 - symmetrical) 6 kV (Test Level 4 - asymmetrical) Output 1 kV (Test Level 2 - symmetrical) 2 kV (Test Level 3 - asymmetrical) Signal 1 kV (Test Level 2 - asymmetrical) Comments Criterion B Conducted interference EN 61000-4-6 Frequency range 0.15 MHz ... 80 MHz Voltage 10 V (Test Level 3) Comments Criterion A Criterion A Normal operating behavior within the specified limits. Criterion B Temporary impairment to operational behavior that is corrected by the device itself. Environmental Product Compliance REACh SVHC Lead 7439-92-1 Drawings 06/17/2020   Page 5 / 9 https://www.phoenixcontact.com/in/products/2903144 Power supply unit - TRIO-PS-2G/1AC/24DC/5/B+D - 2903144 Block diagram Classifications eCl@ss eCl@ss 10.0.1 27040701 eCl@ss 4.0 27040700 eCl@ss 4.1 27040700 eCl@ss 5.0 27049000 eCl@ss 5.1 27049000 eCl@ss 6.0 27049000 eCl@ss 7.0 27049002 eCl@ss 8.0 27049002 eCl@ss 9.0 27040701 ETIM ETIM 3.0 EC001039 ETIM 4.0 EC000599 ETIM 5.0 EC002540 ETIM 6.0 EC002540 ETIM 7.0 EC002540 UNSPSC UNSPSC 6.01 30211502 UNSPSC 7.0901 39121004 UNSPSC 11 39121004 UNSPSC 12.01 39121004 UNSPSC 13.2 39121004 UNSPSC 18.0 39121004 UNSPSC 19.0 39121004 UNSPSC 20.0 39121004 06/17/2020   Page 6 / 9 https://www.phoenixcontact.com/in/products/2903144 Power supply unit - TRIO-PS-2G/1AC/24DC/5/B+D - 2903144 Classifications UNSPSC UNSPSC 21.0 39121004 Approvals Approvals Approvals DNV GL / BSH / UL Listed / UL Recognized / cUL Recognized / cUL Listed / EAC / cULus Recognized / cULus Listed Ex Approvals Approval details DNV GL   BSH   https://approvalfinder.dnvgl.com/  TAA00000BM    Nr. 967 UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 123528 UL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 211944 cUL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 211944 cUL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 123528 EAC      RU*DE*08.B.01873/19 06/17/2020   Page 7 / 9 https://www.phoenixcontact.com/in/products/2903144 Power supply unit - TRIO-PS-2G/1AC/24DC/5/B+D - 2903144 Approvals cULus Recognized       cULus Listed       Accessories Accessories Device circuit breakers Electronic device circuit breaker - CBM E4 24DC/0.5-10A NO-R - 2905743 Multi-channel, electronic device circuit breaker with active current limitation for protecting four loads at 24 V DC in the event of overload and short circuit. With nominal current assistant and electronic locking of the set nominal currents. For installation on DIN rails.     Electronic device circuit breaker - CBM E8 24DC/0.5-10A NO-R - 2905744 Multi-channel, electronic device circuit breaker with active current limitation for protecting eight loads at 24 V DC in the event of overload and short circuit. With nominal current assistant and electronic locking of the set nominal currents. For installation on DIN rails.     Potential distributor Potential distributors - VIP-2/SC/PDM-2/24 - 2315269 VARIOFACE module, with two equipotential busbars (P1, P2) for potential distribution, for mounting on NS 35 rails. Module width: 70.4 mm     Potential distributors - VIP-3/PT/PDM-2/24 - 2903798 VARIOFACE module with push-in connection and two equipotential busbars (P1, P2) for potential distribution, for mounting on NS 35 rails. Module width: 57.1 mm     06/17/2020   Page 8 / 9 https://www.phoenixcontact.com/in/products/2903144 Power supply unit - TRIO-PS-2G/1AC/24DC/5/B+D - 2903144 Accessories Phoenix Contact 2020 © - all rights reserved http://www.phoenixcontact.com 06/17/2020   Page 9 / 9
2903144 价格&库存

很抱歉,暂时无法提供与“2903144”相匹配的价格&库存,您可以联系我们找货

免费人工找货