    AC/DC CONVERTER 24V 240W

  • 数据手册
  • 价格&库存
2903145 数据手册
https://www.phoenixcontact.com/gb/products/2903145 Power supply unit - TRIO-PS-2G/1AC/24DC/10/B+D - 2903145 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: single phase, output: 24 V DC/10 A Product Description TRIO POWER power supplies for more stringent EMC requirements in shipbuilding The TRIO POWER power supply range with Push-in connection has been perfected for use in shipbuilding. All functions and the space-saving design of the single and three-phase modules are optimally tailored to the stringent requirements. Under challenging ambient conditions, the power supply units, which feature an extremely robust electrical and mechanical design, ensure the reliable supply of all loads. Why buy this product  Can be used on the bridge of a ship in accordance with EN 60945  Increase system availability, thanks to dynamic boost with 150% of the nominal current for five seconds  Maximum flexibility due to the wide temperature range from -25°C to +70°C and device startup at -40°C  Rugged design  Save time and costs, thanks to the Push-in connection and narrow design Key Commercial Data Packing unit 1 STK GTIN GTIN 4046356726948 Weight per Piece (excluding packing) 1,188.200 g Custom tariff number 85044030 Country of origin China Technical data Dimensions Width 42 mm Height 130 mm Depth 160 mm Ambient conditions 08/16/2017   Page 1 / 6 https://www.phoenixcontact.com/gb/products/2903145 Power supply unit - TRIO-PS-2G/1AC/24DC/10/B+D - 2903145 Technical data Ambient conditions Degree of protection IP20 Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) Ambient temperature (start-up type tested) -40 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing) Climatic class 3K3 (in acc. with EN 60721) Degree of pollution 2 Installation height ≤ 5000 m (> 2000 m, observe derating) Input data Nominal input voltage range 100 V AC ... 240 V AC 110 V DC ... 250 V DC Input voltage range 100 V AC ... 240 V AC -15 % ... +10 % 110 V DC ... 250 V DC -10 % ... +10 % Dielectric strength maximum 300 V AC 15 s AC frequency range 50 Hz ... 60 Hz ±5 Hz Discharge current to PE < 3.5 mA Current consumption 3.1 A (100 V AC) 2.4 A (120 V AC) 1.3 A (230 V AC) 1.4 A (240 V AC) Nominal power consumption 21.8 W Inrush surge current typ. 20 A Power failure bypass > 20 ms (120 V AC) > 20 ms (230 V AC) Input fuse 6.3 A (internal (device protection)) Choice of suitable circuit breakers 6 A ... 16 A (Characteristics B, C, D, K) Type of protection Transient surge protection Protective circuit/component Varistor Output data Nominal output voltage 24 V DC ±1 % Setting range of the output voltage (USet) 24 V DC ... 28 V DC (constant capacity) Nominal output current (IN) 10 A Dynamic Boost (IDyn.Boost) 15 A (5 s) Derating > 60 °C ... 70 °C (2.5%/K) Connection in parallel Yes, for redundancy and increased capacity Connection in series yes Feedback resistance ≤ 35 V DC Circuit breaker against surge voltage at output by invasive foreign matter ≤ 30 V DC Control deviation < 1 % (change in load, static 10 % ... 90 %) < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz) 08/16/2017   Page 2 / 6 https://www.phoenixcontact.com/gb/products/2903145 Power supply unit - TRIO-PS-2G/1AC/24DC/10/B+D - 2903145 Technical data Output data < 0.1 % (change in input voltage ±10 %) Residual ripple < 20 mVPP (with nominal values) Output power 240 W Typical response time 1800000 h (25 °C) > 1000000 h (40 °C) > 480000 h (60 °C) Mounting position horizontal DIN rail NS 35, EN 60715 Assembly instructions Can be aligned: Horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm Connection data, input Connection method Push-in connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 4 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 Stripping length 10 mm Connection data, output Connection method Push-in connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 4 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 Stripping length 8 mm Connection data for signaling 08/16/2017   Page 3 / 6 https://www.phoenixcontact.com/gb/products/2903145 Power supply unit - TRIO-PS-2G/1AC/24DC/10/B+D - 2903145 Technical data Connection data for signaling Connection method Push-in connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 16 Stripping length 8 mm Standards and Regulations Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Noise emission EN 55011 (EN 55022) Noise immunity EN 61000-6-2:2005 Standards/regulations EN 61000-4-2 Contact discharge 4 kV (Test Level 2) Standards/regulations EN 61000-4-3 Frequency range 80 MHz ... 1 GHz Test field strength 10 V/m (Test Level 3) Frequency range 1.4 GHz ... 2 GHz Test field strength 3 V/m (Test Level 2) Standards/regulations EN 61000-4-4 Comments Criterion B Standards/regulations EN 61000-4-5 Signal 1 kV (Test Level 2 - asymmetrical) Standards/regulations EN 61000-6-3 EN 61000-4-6 Frequency range 0.15 MHz ... 80 MHz Voltage 10 V (Test Level 3) Low Voltage Directive Conformance with LV directive 2006/95/EC Standard - Safety of transformers EN 61558-2-16 (air clearances and creepage distances only) Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV) Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV) Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV) Standard - Safe isolation DIN VDE 0100-410 Standard – Limitation of mains harmonic currents EN 61000-3-2 Shipbuilding approval DNV GL (EMC B) UL approvals UL Listed UL 508 UL/C-UL Recognized UL 60950-1 Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27) 15 Hz ... 150 Hz, 4g, 90 min. 08/16/2017   Page 4 / 6 https://www.phoenixcontact.com/gb/products/2903145 Power supply unit - TRIO-PS-2G/1AC/24DC/10/B+D - 2903145 Technical data Standards and Regulations Approval - requirement of the semiconductor industry with regard to mains voltage dips Semi F47-0706 Rail applications EN 50121-4 Drawings Block diagram L/+ active N/- PFC + + 13 14 Accessories Accessories Device circuit breakers Electronic device circuit breaker - CBM E4 24DC/0.5-10A NO-R - 2905743 Multi-channel, electronic device circuit breaker with active current limitation for protecting four loads at 24 V DC in the event of overload and short circuit. With nominal current assistant and electronic locking of the set nominal currents. For installation on DIN rails.     Electronic device circuit breaker - CBM E8 24DC/0.5-10A NO-R - 2905744 Multi-channel, electronic device circuit breaker with active current limitation for protecting eight loads at 24 V DC in the event of overload and short circuit. With nominal current assistant and electronic locking of the set nominal currents. For installation on DIN rails.     Potential distributor Potential distributors - VIP-2/SC/PDM-2/24 - 2315269 VARIOFACE module, with two equipotential busbars (P1, P2) for potential distribution, for mounting on NS 35 rails. Module width: 70.4 mm     08/16/2017   Page 5 / 6 https://www.phoenixcontact.com/gb/products/2903145 Power supply unit - TRIO-PS-2G/1AC/24DC/10/B+D - 2903145 Accessories Potential distributors - VIP-3/PT/PDM-2/24 - 2903798 VARIOFACE module with push-in connection and two equipotential busbars (P1, P2) for potential distribution, for mounting on NS 35 rails. Module width: 57.1 mm     Redundancy module Diode - TRIO2-DIODE/12-24DC/2X20/1X40 - 2907379 Redundancy module, 12 V - 24 V DC, 2 x 20 A, 1 x 40 A     Diode - TRIO2-DIODE/12-24DC/2X10/1X20 - 2907380 Redundancy module, 12 V - 24 V DC, 2 x 10 A, 1 x 20 A     Phoenix Contact 2017 © - all rights reserved http://www.phoenixcontact.com 08/16/2017   Page 6 / 6
2903145 价格&库存

很抱歉,暂时无法提供与“2903145”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2903145
  •  国内价格 香港价格
  • 1+2336.378511+299.90200
  • 25+2055.3792525+263.83240

库存:0

2903145
  •  国内价格 香港价格
  • 1+2646.101831+339.65868

库存:1

2903145
    •  国内价格
    • 1+2115.30024

    库存:2

    2903145

      库存:100