2903157

2903157

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    AC/DC DIN RAIL SUPPLY 12V 60W

  • 数据手册
  • 价格&库存
2903157 数据手册
https://www.phoenixcontact.com/gb/products/2903157 Power supply unit - TRIO-PS-2G/1AC/12DC/5/C2LPS - 2903157 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 1-phase, output: 12 V DC/5 A C2LPS Product Description TRIO POWER power supplies with standard functionality The TRIO POWER power supply range with push-in connection has been perfected for use in machine building. All functions and the space-saving design of the single and three-phase modules are optimally tailored to the stringent requirements. Under challenging ambient conditions, the power supply units, which feature an extremely robust electrical and mechanical design, ensure the reliable supply of all loads. Why buy this product  Save time and costs, thanks to the Push-in connection and narrow design  Increase system availability, thanks to dynamic boost with 150% of the nominal current for five seconds  Maximum flexibility due to the wide temperature range from -25°C to +70°C and device startup at -40°C  Rugged design Key Commercial Data Packing unit 1 STK GTIN GTIN 4055626248486 Weight per Piece (excluding packing) 486.500 g Custom tariff number 85044030 Country of origin China Technical data Dimensions Width 30 mm Height 130 mm Depth 115 mm Ambient conditions Degree of protection IP20 08/16/2017   Page 1 / 5 https://www.phoenixcontact.com/gb/products/2903157 Power supply unit - TRIO-PS-2G/1AC/12DC/5/C2LPS - 2903157 Technical data Ambient conditions Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) Ambient temperature (storage/transport) -40 °C ... 85 °C Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing) Climatic class 3K3 (in acc. with EN 60721) Degree of pollution 2 Installation height ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m) Input data Nominal input voltage range 100 V AC ... 240 V AC 110 V DC ... 250 V DC Input voltage range 100 V AC ... 240 V AC -15 % ... +10 % 99 V DC ... 275 V DC Dielectric strength maximum ≤ 300 V AC 15 s AC frequency range 50 Hz ... 60 Hz 10 % Discharge current to PE < 0.25 mA Current consumption 1.1 A (100 V AC) 1 A (120 V AC) 0.6 A (230 V AC) 0.6 A (240 V AC) Nominal power consumption 9.9 W Inrush surge current ≤ 25 A (typical) Power failure bypass > 20 ms (120 V AC) > 110 ms (230 V AC) Input fuse 6.3 A Slow-blow Choice of suitable circuit breakers 6 A ... 16 A (Characteristics B, C, D, K) Type of protection Transient surge protection Protective circuit/component Varistor Output data Nominal output voltage 12 V DC ±1 % Setting range of the output voltage (USet) 12 V DC ... 18 V DC (> 12 V DC, constant capacity restricted) Nominal output current (IN) 5A Derating > 60 °C ... 70 °C (2.5%/K) Connection in parallel Yes, for redundancy and increased capacity Connection in series yes Feedback resistance < 25 V Circuit breaker against surge voltage at output by invasive foreign matter ≤ 22 V DC Control deviation < 1 % (change in load, static 10 % ... 90 %) < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz) < 0.1 % (change in input voltage ±10 %) Residual ripple < 50 mVPP (with nominal values) Output power 60 W 08/16/2017   Page 2 / 5 https://www.phoenixcontact.com/gb/products/2903157 Power supply unit - TRIO-PS-2G/1AC/12DC/5/C2LPS - 2903157 Technical data Output data Typical response time 86 % (for 230 V AC and nominal values) Insulation voltage input/output 3 kV AC (type test) 1.5 kV AC (routine test) Protection class II (in closed control cabinet) Degree of protection IP20 MTBF (IEC 61709, SN 29500) > (25 °C) > 2900000 h (40 °C) 60 °C Mounting position horizontal DIN rail NS 35, EN 60715 Assembly instructions Can be aligned: Horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm Connection data, input Connection method Push-in connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 4 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 Stripping length 10 mm Connection data, output Connection method Push-in connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 4 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 Stripping length 8 mm Connection data for signaling Connection method Push-in connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² 08/16/2017   Page 3 / 5 https://www.phoenixcontact.com/gb/products/2903157 Power supply unit - TRIO-PS-2G/1AC/12DC/5/C2LPS - 2903157 Technical data Connection data for signaling Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 16 Stripping length 8 mm Standards and Regulations Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Noise emission EN 55011 (EN 55022) Noise immunity EN 61000-6-2:2005 Standards/regulations EN 61000-4-2 Contact discharge 4 kV (Test Level 2) Standards/regulations EN 61000-4-3 Frequency range 80 MHz ... 1 GHz Test field strength 10 V/m (Test Level 3) Frequency range 1.4 GHz ... 2 GHz Test field strength 3 V/m (Test Level 2) Standards/regulations EN 61000-4-4 Comments Criterion B Standards/regulations EN 61000-4-5 Signal 0.5 kV (Test Level 1 - asymmetrical) Standards/regulations EN 61000-6-3 EN 61000-4-6 Frequency range 0.15 MHz ... 80 MHz Voltage 10 V (Test Level 3) Standards/regulations EN 61000-4-11 Low Voltage Directive Conformance with LV directive 2006/95/EC Standard - Safety of transformers EN 61558-2-16 (air clearances and creepage distances only) Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV) Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV) Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV) Standard - Safe isolation DIN VDE 0100-410 Standard – Limitation of mains harmonic currents EN 61000-3-2 UL approvals UL Listed UL 508 UL/C-UL Recognized UL 60950-1 NEC Class 2 as per UL 1310 Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27) Vibration (operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) 15 Hz ... 150 Hz, 4g, 90 min. Rail applications EN 50121-4 Overvoltage category (EN 60950-1) II 08/16/2017   Page 4 / 5 https://www.phoenixcontact.com/gb/products/2903157 Power supply unit - TRIO-PS-2G/1AC/12DC/5/C2LPS - 2903157 Drawings Block diagram L/+ N/- + + 13 14 Phoenix Contact 2017 © - all rights reserved http://www.phoenixcontact.com 08/16/2017   Page 5 / 5
2903157 价格&库存

很抱歉,暂时无法提供与“2903157”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2903157
    •  国内价格 香港价格
    • 1+1009.215711+125.19274

    库存:4