https://www.phoenixcontact.com/gb/products/2903157
Power supply unit - TRIO-PS-2G/1AC/12DC/5/C2LPS - 2903157
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 1-phase,
output: 12 V DC/5 A C2LPS
Product Description
TRIO POWER power supplies with standard functionality
The TRIO POWER power supply range with push-in connection has been perfected for use in machine building. All functions and the space-saving
design of the single and three-phase modules are optimally tailored to the stringent requirements. Under challenging ambient conditions, the power
supply units, which feature an extremely robust electrical and mechanical design, ensure the reliable supply of all loads.
Why buy this product
Save time and costs, thanks to the Push-in connection and narrow design
Increase system availability, thanks to dynamic boost with 150% of the nominal current for five seconds
Maximum flexibility due to the wide temperature range from -25°C to +70°C and device startup at -40°C
Rugged design
Key Commercial Data
Packing unit
1 STK
GTIN
GTIN
4055626248486
Weight per Piece (excluding packing)
486.500 g
Custom tariff number
85044030
Country of origin
China
Technical data
Dimensions
Width
30 mm
Height
130 mm
Depth
115 mm
Ambient conditions
Degree of protection
IP20
08/16/2017 Page 1 / 5
https://www.phoenixcontact.com/gb/products/2903157
Power supply unit - TRIO-PS-2G/1AC/12DC/5/C2LPS - 2903157
Technical data
Ambient conditions
Ambient temperature (operation)
-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Max. permissible relative humidity (operation)
≤ 95 % (at 25 °C, non-condensing)
Climatic class
3K3 (in acc. with EN 60721)
Degree of pollution
2
Installation height
≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
Input data
Nominal input voltage range
100 V AC ... 240 V AC
110 V DC ... 250 V DC
Input voltage range
100 V AC ... 240 V AC -15 % ... +10 %
99 V DC ... 275 V DC
Dielectric strength maximum
≤ 300 V AC 15 s
AC frequency range
50 Hz ... 60 Hz 10 %
Discharge current to PE
< 0.25 mA
Current consumption
1.1 A (100 V AC)
1 A (120 V AC)
0.6 A (230 V AC)
0.6 A (240 V AC)
Nominal power consumption
9.9 W
Inrush surge current
≤ 25 A (typical)
Power failure bypass
> 20 ms (120 V AC)
> 110 ms (230 V AC)
Input fuse
6.3 A Slow-blow
Choice of suitable circuit breakers
6 A ... 16 A (Characteristics B, C, D, K)
Type of protection
Transient surge protection
Protective circuit/component
Varistor
Output data
Nominal output voltage
12 V DC ±1 %
Setting range of the output voltage (USet)
12 V DC ... 18 V DC (> 12 V DC, constant capacity restricted)
Nominal output current (IN)
5A
Derating
> 60 °C ... 70 °C (2.5%/K)
Connection in parallel
Yes, for redundancy and increased capacity
Connection in series
yes
Feedback resistance
< 25 V
Circuit breaker against surge voltage at output by invasive foreign matter ≤ 22 V DC
Control deviation
< 1 % (change in load, static 10 % ... 90 %)
< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
< 0.1 % (change in input voltage ±10 %)
Residual ripple
< 50 mVPP (with nominal values)
Output power
60 W
08/16/2017 Page 2 / 5
https://www.phoenixcontact.com/gb/products/2903157
Power supply unit - TRIO-PS-2G/1AC/12DC/5/C2LPS - 2903157
Technical data
Output data
Typical response time
86 % (for 230 V AC and nominal values)
Insulation voltage input/output
3 kV AC (type test)
1.5 kV AC (routine test)
Protection class
II (in closed control cabinet)
Degree of protection
IP20
MTBF (IEC 61709, SN 29500)
> (25 °C)
> 2900000 h (40 °C)
60 °C
Mounting position
horizontal DIN rail NS 35, EN 60715
Assembly instructions
Can be aligned: Horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically
50 mm
Connection data, input
Connection method
Push-in connection
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
4 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
12
Stripping length
10 mm
Connection data, output
Connection method
Push-in connection
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
4 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
12
Stripping length
8 mm
Connection data for signaling
Connection method
Push-in connection
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
1.5 mm²
Conductor cross section flexible min.
0.2 mm²
08/16/2017 Page 3 / 5
https://www.phoenixcontact.com/gb/products/2903157
Power supply unit - TRIO-PS-2G/1AC/12DC/5/C2LPS - 2903157
Technical data
Connection data for signaling
Conductor cross section flexible max.
1.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
16
Stripping length
8 mm
Standards and Regulations
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Noise emission
EN 55011 (EN 55022)
Noise immunity
EN 61000-6-2:2005
Standards/regulations
EN 61000-4-2
Contact discharge
4 kV (Test Level 2)
Standards/regulations
EN 61000-4-3
Frequency range
80 MHz ... 1 GHz
Test field strength
10 V/m (Test Level 3)
Frequency range
1.4 GHz ... 2 GHz
Test field strength
3 V/m (Test Level 2)
Standards/regulations
EN 61000-4-4
Comments
Criterion B
Standards/regulations
EN 61000-4-5
Signal
0.5 kV (Test Level 1 - asymmetrical)
Standards/regulations
EN 61000-6-3
EN 61000-4-6
Frequency range
0.15 MHz ... 80 MHz
Voltage
10 V (Test Level 3)
Standards/regulations
EN 61000-4-11
Low Voltage Directive
Conformance with LV directive 2006/95/EC
Standard - Safety of transformers
EN 61558-2-16 (air clearances and creepage distances only)
Standard - Electrical safety
IEC 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations
and their assembly into electrical power installations
EN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltage
IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard - Safe isolation
DIN VDE 0100-410
Standard – Limitation of mains harmonic currents
EN 61000-3-2
UL approvals
UL Listed UL 508
UL/C-UL Recognized UL 60950-1
NEC Class 2 as per UL 1310
Shock
18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 4g, 90 min.
Rail applications
EN 50121-4
Overvoltage category (EN 60950-1)
II
08/16/2017 Page 4 / 5
https://www.phoenixcontact.com/gb/products/2903157
Power supply unit - TRIO-PS-2G/1AC/12DC/5/C2LPS - 2903157
Drawings
Block diagram
L/+
N/-
+
+
13
14
Phoenix Contact 2017 © - all rights reserved
http://www.phoenixcontact.com
08/16/2017 Page 5 / 5