https://www.phoenixcontact.com/us/products/2903335
Relay Module - RIF-1-RPT-LV-230AC/1X21AU - 2903335
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Pre-assembled relay module with push-in connection, consisting of: relay base, multi-layer contact relay, plug-in
display/suppressor module, and retaining bracket. Contact type: 1 PDT. Input voltage: 230 V AC
The figure shows the 24 V DC
version
Key Commercial Data
Packing unit
1 pc
Weight per Piece (excluding packing)
68.0 g
Custom tariff number
85364900
Country of origin
Germany
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
16 mm
Height
93 mm
Depth
75 mm
Ambient conditions
Ambient temperature (operation)
-40 °C ... 50 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Coil side
Nominal input voltage UN
230 V AC
Input voltage range in reference to UN
see diagram
Mains frequency
50 Hz
04/11/2016 Page 1 / 7
https://www.phoenixcontact.com/us/products/2903335
Relay Module - RIF-1-RPT-LV-230AC/1X21AU - 2903335
Technical data
Coil side
60 Hz
Typical input current at UN
6 mA
Typical response time
3 ms ... 12 ms
Typical release time range
3 ms ... 20 ms
Coil voltage
230 V AC
Protective circuit
Varistor
Operating voltage display
Yellow LED
Contact side
Contact type
1 PDT
Contact material
AgNi, hard gold-plated
Maximum switching voltage
30 V AC
36 V DC
Minimum switching voltage
100 mV (at 10 mA)
Min. switching current
1 mA (at 24 V)
Maximum inrush current
50 mA
Limiting continuous current
50 mA
Interrupting rating (ohmic load) max.
1.2 W (at 24 V DC)
Switching capacity in acc. with DIN VDE 0660/IEC 60947
2 A (at 24 V, AC15)
Note
the following values are applicable if a gold layer is destroyed
Maximum switching voltage
250 V AC/DC
Minimum switching voltage
12 V (at 10 mA)
Limiting continuous current
25 A (20 ms, N/O contact)
Min. switching current
10 mA (at 12 V)
Interrupting rating (ohmic load) max.
240 W (at 24 V DC)
58 W (at 48 V DC)
48 W (at 60 V DC)
50 W (at 110 V DC)
80 W (at 220 V DC)
2500 VA (for 250 V AC)
Switching capacity in acc. with DIN VDE 0660/IEC 60947
2 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.2 A (at 250 V, DC13)
2 A (at 24 V, AC15)
2 A (at 120 V, AC15)
2 A (at 250 V, AC15)
Connection data input side
04/11/2016 Page 2 / 7
https://www.phoenixcontact.com/us/products/2903335
Relay Module - RIF-1-RPT-LV-230AC/1X21AU - 2903335
Technical data
Connection data input side
Connection name
Coil side
Connection method
Push-in connection
Stripping length
8 mm
Conductor cross section solid
0.14 mm² ... 1.5 mm²
Conductor cross section flexible
0.14 mm² ... 1.5 mm²
0.14 mm² ... 1 mm² (Ferrule with plastic sleeve)
0.14 mm² ... 1.5 mm² (Ferrules without plastic sleeve)
Conductor cross section AWG
26 ... 16
Connection data output side
Connection name
Contact side
Connection method
Push-in connection
Stripping length
8 mm
Conductor cross section solid
0.14 mm² ... 1.5 mm²
Conductor cross section flexible
0.14 mm² ... 1.5 mm²
0.14 mm² ... 1 mm² (Ferrule with plastic sleeve)
0.14 mm² ... 1.5 mm² (Ferrules without plastic sleeve)
Conductor cross section AWG
26 ... 16
General
Type of note
Notes on operation
Note
FBS 2-6... plug-in bridge for the input side (A2) and FBS-2-8... plug-in
bridge for the output side (11/21)
Test voltage relay winding/relay contact
4 kVrms (50 Hz, 1 min.)
Operating mode
100% operating factor
Degree of protection
IP20 (Relay socket)
RT II (Relay)
Mechanical service life
Approx. 10 cycles
Standards/regulations
DIN EN 50178
7
IEC 62103
Rated insulation voltage
250 V AC
Degree of pollution
2
Overvoltage category
III
Mounting position
any
Assembly instructions
In rows with zero spacing
Standards and Regulations
Standards/regulations
DIN EN 50178
IEC 62103
04/11/2016 Page 3 / 7
https://www.phoenixcontact.com/us/products/2903335
Relay Module - RIF-1-RPT-LV-230AC/1X21AU - 2903335
Technical data
Standards and Regulations
Rated insulation voltage
250 V AC
Insulation
safe isolation
Degree of pollution
2
Overvoltage category
III
Articles in set
Relay socket - RIF-1-BPT/2X21 - 2900931
RIF-1... relay base, for miniature power relay with 1 or 2 PDTs or solid-state relays of the same design, push-in
connection, plug-in option for input/suppressor modules, for mounting on NS 35/7,5
Single relay - REL-MR-230AC/21HC AU - 2961529
Plug-in miniature power relay, with multi-layer gold contact for high continuous currents, 1 PDT, input voltage 230 V AC
Plug-in module - RIF-LV-120-230 AC/110 DC - 2900944
Plug-in module, for mounting on RIF-1, RIF-2, RIF-3, and RIF-4, with varistor and yellow LED, input voltage: 120 - 230 V
AC/110 V DC ±20%
Retaining bracket - RIF-RH-1 - 2900953
Relay retaining bracket, with ejector function and holder for marking material, suitable for RIF-1 relay base, for 16 mm tall
miniature power relay and solid-state relay
04/11/2016 Page 4 / 7
https://www.phoenixcontact.com/us/products/2903335
Relay Module - RIF-1-RPT-LV-230AC/1X21AU - 2903335
Classifications
eCl@ss
eCl@ss 4.0
27371102
eCl@ss 4.1
27371102
eCl@ss 5.0
27371603
eCl@ss 5.1
27371603
eCl@ss 6.0
27371603
eCl@ss 7.0
27371603
eCl@ss 8.0
27371601
eCl@ss 9.0
27371601
ETIM
ETIM 3.0
EC001456
ETIM 4.0
EC001456
ETIM 5.0
EC001437
UNSPSC
UNSPSC 6.01
30211917
UNSPSC 7.0901
39121516
UNSPSC 11
39121516
UNSPSC 12.01
39121516
UNSPSC 13.2
39121516
Approvals
Approvals
Approvals
EAC / GL / LR / EAC
Ex Approvals
Approvals submitted
Approval details
EAC
04/11/2016 Page 5 / 7
https://www.phoenixcontact.com/us/products/2903335
Relay Module - RIF-1-RPT-LV-230AC/1X21AU - 2903335
Approvals
GL
LR
EAC
Drawings
22
12
24
14
21
11
A2
Diagram
Coil voltage U/UN
Circuit diagram
A1
AC coils
1,8
1,7
1,6
1,5
1,4
1,3
1,2
1,1
1,0
0,9
0,8
0,7
0,6
20
30
40
50
60
70
Ambient temperature [°C]
80
DC coils
AC coils
Operating voltage range
Diagram
Diagram
10
6
4
Cycles
Switching current [A]
20
2
10
7
10
6
1
1
0,5
0,3
0,2
0,1
10
20
30
AC, ohmic load
DC, ohmic load
DC, L/R = 40 ms
Interrupting rating
50 70 100
200
Switching voltage [V]
300
10
5
10
4
0
2
1
2
3
4
5
6
7 8
9 10 11 12 13 14 15 16
Switching current [A]
1 250 V AC, ohmic load (DC coils)
2 250 V AC, ohmic load (AC coils)
Electrical service life
04/11/2016 Page 6 / 7
https://www.phoenixcontact.com/us/products/2903335
Relay Module - RIF-1-RPT-LV-230AC/1X21AU - 2903335
Diagram
1
Reduction factor
0,9
0,8
0,7
0,6
0,5
0,4
0,3
1
0,9
0,8
0,7
0,6
0,5
0,4
0,3
0,2
COS j
Service life reduction factor
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
04/11/2016 Page 7 / 7