2903920

2903920

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

  • 数据手册
  • 价格&库存
2903920 数据手册
https://www.phoenixcontact.com/us/products/2903920 Hybrid motor starter - ELR H3-I-PT- 24DC/500AC-0,6 - 2903920 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection. Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356771436 Weight per Piece (excluding packing) 280.000 g Custom tariff number 85371098 Country of origin Germany Technical data Dimensions Width 22.5 mm Height 107.5 mm Depth 114 mm Ambient conditions Ambient temperature (operation) -25 °C ... 70 °C (observe derating) Ambient temperature (storage/transport) -40 °C ... 80 °C Maximum altitude ≤ 2000 m Degree of protection IP20 Device supply Rated control circuit supply voltage US 24 V DC 02/09/2020   Page 1 / 11 https://www.phoenixcontact.com/us/products/2903920 Hybrid motor starter - ELR H3-I-PT- 24DC/500AC-0,6 - 2903920 Technical data Device supply Control supply voltage range 19.2 V DC ... 30 V DC Rated control supply current IS 40 mA Type of protection Surge protection Reverse polarity protection Input data Input name Control input Rated actuating voltage UC 24 V DC Triggering voltage range 19.2 V DC ... 30 V DC Rated actuating current IC 5 mA (Input type 1) Switching threshold 9.6 V (“0” signal) 19.2 V (“1” signal) Typical turn-off time < 30 ms Type of protection Reverse polarity protection Output data load output Output name AC output Rated operating voltage Ue 500 V AC Operating voltage range 42 V AC ... 550 V AC Rated operating current Ie 0.6 A (AC-51) 0.6 A (AC-53a) Mains frequency 50/60 Hz Load current range 75 mA ... 600 mA (see to derating) Trigger characteristic in acc. with IEC 60947-4-2 Class 10A Cooling time 20 min. (for auto reset) Leakage current 0 mA Type of protection Surge protection Output data reply output Output name Acknowledge output Note Confirmation: floating change-over contact, signal contact Contact type 1 PDT Switching capacity according to IEC 60947-5-1 3 A (230 V, AC15) 2 A (24 V, DC13) General Motor starter type Direct starter Switching frequency ≤ 2 Hz (Load-dependent) Mounting position vertical (horizontal DIN rail, motor output below) 02/09/2020   Page 2 / 11 https://www.phoenixcontact.com/us/products/2903920 Hybrid motor starter - ELR H3-I-PT- 24DC/500AC-0,6 - 2903920 Technical data General Mounting type DIN rail mounting Assembly instructions alignable, for spacing see derating Operating mode 100% operating factor Maximum power dissipation 1.5 W Minimum power dissipation 1.1 W Operating voltage display Green LED Status display Yellow LED Indication Red LED Connection data Connection name Control circuits Connection method Push-in connection Stripping length 10 mm Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 Connection data 2 Connection name Load circuit Connection method Push-in connection Stripping length 10 mm Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 Insulation characteristics Rated insulation voltage 500 V Rated surge voltage 6 kV Overvoltage category III Degree of pollution 2 Designation Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit Insulation Safe isolation (IEC 60947-1) at operating voltage ≤ 300 V AC (e.g., 230/400 V AC, 277/480 V AC) Safe isolation (EN 50178) at operating voltage ≤ 300 V A (e.g., 230/400 V AC, 277/480 V AC) Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC Designation Isolation characteristics between the control input and control supply voltage to auxiliary circuit 02/09/2020   Page 3 / 11 https://www.phoenixcontact.com/us/products/2903920 Hybrid motor starter - ELR H3-I-PT- 24DC/500AC-0,6 - 2903920 Technical data Insulation characteristics Insulation Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC Standards and Regulations Designation Standards/regulations Standards/regulations IEC 60947-1 IEC 60947-4-2 IEC 61508 ISO 13849 Conformance/approvals Designation UL approval Certificate NLDX.E228652 UL data SCCR 100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault))) 5 kA (500 V AC (fuse: 20 A RK5 (standard fault))) FLA 0.6 A (500 V AC) Group installation 20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded) 30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded) Category code NLDX / NRNT Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings 02/09/2020   Page 4 / 11 https://www.phoenixcontact.com/us/products/2903920 Hybrid motor starter - ELR H3-I-PT- 24DC/500AC-0,6 - 2903920 Block diagram Diagram Derating diagram 02/09/2020   Page 5 / 11 https://www.phoenixcontact.com/us/products/2903920 Hybrid motor starter - ELR H3-I-PT- 24DC/500AC-0,6 - 2903920 Classifications eCl@ss eCl@ss 4.0 27021100 eCl@ss 4.1 27021100 eCl@ss 5.0 27024000 eCl@ss 5.1 27024000 eCl@ss 6.0 27024000 eCl@ss 7.0 27024002 eCl@ss 8.0 27024002 eCl@ss 9.0 27370905 ETIM ETIM 2.0 EC001037 ETIM 3.0 EC001037 ETIM 4.0 EC001037 ETIM 5.0 EC001037 ETIM 6.0 EC001037 ETIM 7.0 EC001037 UNSPSC UNSPSC 6.01 30211915 UNSPSC 7.0901 39121514 UNSPSC 11 39121514 UNSPSC 12.01 39121514 UNSPSC 13.2 25173902 UNSPSC 18.0 25173902 UNSPSC 19.0 25173902 UNSPSC 20.0 25173902 UNSPSC 21.0 25173902 Approvals Approvals Approvals UL Listed / cUL Listed / UL Listed / IECEE CB Scheme / cUL Listed / CCC / EAC Ex Approvals 02/09/2020   Page 6 / 11 https://www.phoenixcontact.com/us/products/2903920 Hybrid motor starter - ELR H3-I-PT- 24DC/500AC-0,6 - 2903920 Approvals Approval details UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 228652 cUL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 228652 UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 323771 IECEE CB Scheme    http://www.iecee.org/  DE1-55728 cUL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 323771 CCC      2016010304871315 EAC      TR_TS_S_00520_19_C Accessories Accessories Adapter 02/09/2020   Page 7 / 11 https://www.phoenixcontact.com/us/products/2903920 Hybrid motor starter - ELR H3-I-PT- 24DC/500AC-0,6 - 2903920 Accessories Adapter - EM-CPS-DA-22,5F/16A - 1002668 ® Device adapter with fuse holder for 16 A fuse (10x38/Class CC), CrossLink interface and fixed DIN rail     Assembly adapter Power distribution board - EM-CPS-225 - 1002634 ® Modular power distribution board with CrossLink interface, 125 A, 3-pos., touch-proof and protection against polarity reversal, width: 225 mm     Power distribution board - EM-CPS-405 - 1002635 ® Modular power distribution board with CrossLink interface, 125 A, 3-pos., touch-proof and protection against polarity reversal, width: 405 mm     Connection module - EM-CPS-TB3/63A - 1002633 Connection module with integrated spring-loaded terminals for cables from 1.5 to 16 mm², 3-pos., maximum 63 A     Cover Covering hood - BRIDGE COVER - 2906240 The BRIDGE COVER covering hood is used to cover unused plugs on the CONTACTRON bridge that may subsequently be used to extend the system. The hood can be used with the screw and Push-in version of the bridge.     02/09/2020   Page 8 / 11 https://www.phoenixcontact.com/us/products/2903920 Hybrid motor starter - ELR H3-I-PT- 24DC/500AC-0,6 - 2903920 Accessories Device marking Plastic label - US-EMLP (15X5) - 0828790 Plastic label, Card, white, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels: 189     Plastic label - UC-EMLP (15X5) - 0819301 Plastic label, Sheet, white, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels: 10     Loop bridge Jumper - BRIDGE-PT 2 - 2904490 3-phase loop bridge for 2 CONTACTRON modules, with push-in connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Jumper - BRIDGE-PT 3 - 2904491 3-phase loop bridge for 3 CONTACTRON modules, with push-in connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     02/09/2020   Page 9 / 11 https://www.phoenixcontact.com/us/products/2903920 Hybrid motor starter - ELR H3-I-PT- 24DC/500AC-0,6 - 2903920 Accessories Jumper - BRIDGE-PT 4 - 2904492 3-phase loop bridge for 4 CONTACTRON modules, with push-in connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Jumper - BRIDGE-PT 5 - 2904493 3-phase loop bridge for 5 CONTACTRON modules, with push-in connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Jumper - BRIDGE-PT 6 - 2904494 3-phase loop bridge for 6 CONTACTRON modules, with push-in connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Jumper - BRIDGE-PT 7 - 2904495 3-phase loop bridge for 7 CONTACTRON modules, with push-in connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Jumper - BRIDGE-PT 8 - 2904496 3-phase loop bridge for 8 CONTACTRON modules, with push-in connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     02/09/2020   Page 10 / 11 https://www.phoenixcontact.com/us/products/2903920 Hybrid motor starter - ELR H3-I-PT- 24DC/500AC-0,6 - 2903920 Accessories Jumper - BRIDGE-PT 9 - 2904497 3-phase loop bridge for 9 CONTACTRON modules, with push-in connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Jumper - BRIDGE-PT 10 - 2904498 3-phase loop bridge for 10 CONTACTRON modules, with push-in connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Phoenix Contact 2020 © - all rights reserved http://www.phoenixcontact.com 02/09/2020   Page 11 / 11
2903920 价格&库存

很抱歉,暂时无法提供与“2903920”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2903920
  •  国内价格 香港价格
  • 1+1657.275121+207.62106

库存:1