0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2904089

2904089

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    MACX MCR-SL-RPSS-2I-2I

  • 数据手册
  • 价格&库存
2904089 数据手册
https://www.phoenixcontact.com/us/products/2904089 Signal isolator - MACX MCR-SL-RPSS-2I-2I - 2904089 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) 2-channel repeater power supply for operating 2-wire measuring transducers, input: 4…20 mA (powered), output: 4…20 mA (active), bidirectional transmission of digital HART communication signals, with screw connection Key Commercial Data Packing unit 1 STK Weight per Piece (excluding packing) 160.000 g Custom tariff number 85437090 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 12.5 mm Height 99 mm Depth 114.5 mm Ambient conditions Ambient temperature (operation) -20 °C ... 60 °C (Any mounting position) Ambient temperature (storage/transport) -40 °C ... 80 °C Maximum altitude ≤ 2000 m Permissible humidity (operation) 10 % ... 95 % (non-condensing) Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. 09/06/2016   Page 1 / 6 https://www.phoenixcontact.com/us/products/2904089 Signal isolator - MACX MCR-SL-RPSS-2I-2I - 2904089 Technical data Ambient conditions Degree of protection IP20 Input data Current input signal 4 mA ... 20 mA Transmitter supply voltage > 16 V (at 20 mA) Output data Signal output Current output Current output signal 4 mA ... 20 mA (active) Transmission Behavior 1:1 to input signal Load/output load current output ≤ 450 Ω (20 mA) ≤ 375 Ω (24 mA) Output behavior in the event of an error < 3.6 mA (In the event of cable break at the input (as per NE 43)) > 22.5 mA (In the event of cable short circuit at the input (as per NE 43)) Power supply Nominal supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC (24 V DC -20%...+25%) Max. current consumption < 100 mA (24 V / 20 mA) Power consumption < 1.4 W (at 24 V DC / 20 mA) Connection data Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 16 Stripping length 8 mm Screw thread M3 Connection method Screw connection Tightening torque, min 0.5 Nm Tightening torque max 0.6 Nm General Maximum transmission error < 0.1 % (of final value) Transmission error, typical < 0.05 % (of final value) Maximum temperature coefficient < 0.01 %/K Step response (10-90%) < 1.3 ms (for 4 mA ... 20 mA step) Status display Green LED (supply voltage) 09/06/2016   Page 2 / 6 https://www.phoenixcontact.com/us/products/2904089 Signal isolator - MACX MCR-SL-RPSS-2I-2I - 2904089 Technical data General Flammability rating according to UL 94 V0 Degree of pollution 2 Overvoltage category II Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Interference emission EN 61000-6-4 Housing material PA 66-FR Color green Designation Input/output, power supply Electrical isolation 300 Vrms (Rated insulation voltage (overvoltage category II; degree of pollution 2, safe isolation as per EN 61010-1)) 2.5 kV (50 Hz, 1 min., test voltage) Designation Input/output Electrical isolation 375 V (Peak value in accordance with EN 60079-11) Designation Input/power supply Electrical isolation 375 V (Peak value in accordance with EN 60079-11) Designation Output 1/output 2/ power supply Electrical isolation 1.5 kV (50 Hz, 1 min., test voltage) Conformance CE-compliant, additionally EN 61326 ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA/Canada UL 61010 Listed Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, Group IIC T4 Data communication (bypass) HART function Yes Protocols supported HART Standards and Regulations Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Noise emission EN 61000-6-4 Flammability rating according to UL 94 V0 Conformance CE-compliant, additionally EN 61326 ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA/Canada UL 61010 Listed Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, Group IIC T4 Drawings 09/06/2016   Page 3 / 6 https://www.phoenixcontact.com/us/products/2904089 Signal isolator - MACX MCR-SL-RPSS-2I-2I - 2904089 Block diagram Sensor / Field Pictogram OUT IN PLC / DCS AI passive 4.2 - 4.2 CH1 + 4.1 4.1 3.2 active 3.2 CH1 3.1 + 3.1 HHT HHT passive 5.2 - 5.2 CH2 + 5.1 5.1 active 2.2 2.2 CH2 2.1 HHT GND +24V 2.1 POWER IN POWER IN - + HHT 1.2 I I OUT I I OUT POWER 1.1 Power GND +24V Zone 2 Classifications eCl@ss eCl@ss 4.0 27210120 eCl@ss 4.1 27210120 eCl@ss 5.0 27210120 eCl@ss 5.1 27210120 eCl@ss 6.0 27210120 eCl@ss 7.0 27210120 eCl@ss 8.0 27210120 eCl@ss 9.0 27210120 ETIM ETIM 3.0 EC001485 ETIM 4.0 EC002498 ETIM 5.0 EC002653 UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 39121008 Approvals Approvals 09/06/2016   Page 4 / 6 https://www.phoenixcontact.com/us/products/2904089 Signal isolator - MACX MCR-SL-RPSS-2I-2I - 2904089 Approvals Approvals UL Listed / cUL Listed / Functional Safety / cULus Listed Ex Approvals UL Listed / cUL Listed / cULus Listed Approval details UL Listed  cUL Listed   http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 330267  http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 330267 Functional Safety   BVS Pb 04/13 cULus Listed    Accessories Accessories DIN rail connector DIN rail bus connectors - ME 6,2 TBUS-2 1,5/5-ST-3,81 GN - 2869728 DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold-plated contacts, 5-pos.     Power module 09/06/2016   Page 5 / 6 https://www.phoenixcontact.com/us/products/2904089 Signal isolator - MACX MCR-SL-RPSS-2I-2I - 2904089 Accessories Power and error message module - MACX MCR-PTB - 2865625 Power and fault signaling module with screw connection, including corresponding ME 17,5 TBUS 1,5/ 5-ST-3,81 GN DIN rail connector     Power and error message module - MACX MCR-PTB-SP - 2924184 Power and fault signaling module with push-in connection, including corresponding ME 17,5 TBUS 1,5/ 5-ST-3,81 GN DIN rail connector     Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 09/06/2016   Page 6 / 6
2904089 价格&库存

很抱歉,暂时无法提供与“2904089”相匹配的价格&库存,您可以联系我们找货

免费人工找货