Fault monitoring module with plug-in connection technology for evaluating and reporting group errors from the
FM system and for monitoring the supply voltages. Error message via N/C contact. Screw connection technology,
standard configuration
Product Description
The fault monitoring module with plug-in connection technology is used to evaluate and report group errors from the fault monitoring system of up to
115 connected MINI Analog Pro signal conditioners via the ME 6,2 TBUS-2 DIN rail connector (Order No.: 2869728). You can also monitor the supply
voltages of MINI MCR-2-PTB(-PT) power terminals (Order No.: 2902066, 2902067). Drawing off the supply is also possible. The error is reported via an
N/C contact. The error reporting module supports NFC communication.
Key Commercial Data
Packing unit
1 pc
GTIN
GTIN
4046356857406
Weight per Piece (excluding packing)
40.000 g
Custom tariff number
85437090
Country of origin
Germany
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
6.2 mm
Height
109.81 mm
Depth
119.2 mm
06/14/2020 Page 1 / 11
https://www.phoenixcontact.com/us/products/2904504
Monitoring module - MINI MCR-2-FM-RC - 2904504
Technical data
Ambient conditions
Ambient temperature (operation)
-40 °C ... 70 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Maximum altitude
≤ 2000 m
Permissible humidity (operation)
5 % ... 95 % (non-condensing)
Degree of protection
IP20 (not assessed by UL)
Noise immunity
EN 61000-6-2 When being exposed to interference, there may be minimal
deviations.
Input data
Description of the input
Voltage input for redundancy monitoring
Number of inputs
1
Voltage input signal
9.9 V DC ... 30 V DC
Output data
Number of outputs
1
Voltage output signal
9.6 V DC ... 29.7 V DC
Max. output current
3.2 A
Switching output
Output name
Switching output
Maximum switching voltage
30 V DC
Max. switching current
50 mA DC
Power supply
Supply voltage range
9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5ST-3,81 GN, Order No. 2869728) can be used to bridge the supply
voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
Max. current consumption
< 16 mA (at 24 V DC)
Power consumption
< 410 mW (at 24 V DC)
Connection data
Connection method
Screw connection
Stripping length
10 mm
Screw thread
M3
Conductor cross section solid
0.2 mm² ... 1.5 mm² (with ferrule)
0.14 mm² ... 2.5 mm² (without ferrule)
Conductor cross section flexible
0.14 mm² ... 2.5 mm²
Conductor cross section AWG
24 ... 12 (flexible)
Torque
0.5 Nm ... 0.6 Nm
General
Maximum temperature coefficient
< 0.01 %/K
06/14/2020 Page 2 / 11
https://www.phoenixcontact.com/us/products/2904504
Monitoring module - MINI MCR-2-FM-RC - 2904504
Technical data
General
Test voltage
1500 V AC (50 Hz, 1 min.)
Status display
Yellow LED (switching output)
Electrical isolation
Basic insulation according to EN 61010
Overvoltage category
II
Degree of pollution
2
Rated insulation voltage
50 V AC/DC (effective)
Test voltage input/output
1.5 kV AC (50 Hz, 1 min.)
Electromagnetic compatibility
Conformance with EMC directive
Noise emission
EN 61000-6-4
Noise immunity
EN 61000-6-2 When being exposed to interference, there may be minimal
deviations.
Housing material
PBT
Mounting position
any
Conformance
CE-compliant
ATEX
II 3 G Ex nA IIC T4 Gc X
UL, USA/Canada
UL 508 Listed
Class I, Div. 2, Groups A, B, C, D T6
Class I, Zone 2, Group IIC T6
Certificate of classification
DNV GL 14445-15HH
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 2
Standards and Regulations
Electromagnetic compatibility
Conformance with EMC directive
Noise emission
EN 61000-6-4
Standards/regulations
EN 61000-4-2
Designation
Electromagnetic RF field
Standards/regulations
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
Designation
Conducted interferences
Standards/regulations
EN 61000-4-6
Electrical isolation
Basic insulation according to EN 61010
Conformance
CE-compliant
ATEX
II 3 G Ex nA IIC T4 Gc X
UL, USA/Canada
UL 508 Listed
Class I, Div. 2, Groups A, B, C, D T6
06/14/2020 Page 3 / 11
https://www.phoenixcontact.com/us/products/2904504
Monitoring module - MINI MCR-2-FM-RC - 2904504
Technical data
Standards and Regulations
Class I, Zone 2, Group IIC T6
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category
“Manufacturer's declaration”
Drawings
Block diagram
Classifications
eCl@ss
eCl@ss 10.0.1
27371392
eCl@ss 4.0
27378000
eCl@ss 4.1
27378000
eCl@ss 5.0
27379100
eCl@ss 5.1
27379100
eCl@ss 6.0
27379200
06/14/2020 Page 4 / 11
https://www.phoenixcontact.com/us/products/2904504
Monitoring module - MINI MCR-2-FM-RC - 2904504
Classifications
eCl@ss
eCl@ss 7.0
27379201
eCl@ss 8.0
27379201
eCl@ss 9.0
27379201
ETIM
ETIM 4.0
EC002498
ETIM 5.0
EC002498
ETIM 6.0
EC002498
ETIM 7.0
EC002498
UNSPSC
UNSPSC 6.01
26121604
UNSPSC 7.0901
26121604
UNSPSC 11
26121604
UNSPSC 12.01
26121604
UNSPSC 13.2
26121604
UNSPSC 18.0
39121421
UNSPSC 19.0
39121421
UNSPSC 20.0
39121421
UNSPSC 21.0
39121421
Approvals
Approvals
Approvals
GL / UL Listed / cUL Listed / cULus Listed
Ex Approvals
ATEX / UL Listed / cUL Listed / EAC Ex / cULus Listed
Approval details
GL
https://approvalfinder.dnvgl.com/
14445-15 HH
06/14/2020 Page 5 / 11
https://www.phoenixcontact.com/us/products/2904504
Monitoring module - MINI MCR-2-FM-RC - 2904504
Approvals
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 238705
cUL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 238705
cULus Listed
Accessories
Accessories
Communication module
Communication module - MINI MCR-2-V8-MOD-RTU - 2905634
Eight MINI Analog Pro signal conditioners and measuring transducers can be quickly and easily integrated into a
Modbus/RTU network via a communication adapter.
Communication module - MINI MCR-2-V8-MOD-TCP - 2905635
Eight MINI Analog Pro signal conditioners and measuring transducers can be quickly and easily integrated into a
Modbus/TCP network via a communication adapter.
Communication module - MINI MCR-2-V8-PB-DP - 2905636
Eight MINI Analog Pro signal conditioners and measuring transducers can be quickly and easily integrated into a
PROFIBUS DP network via a communication adapter.
06/14/2020 Page 6 / 11
https://www.phoenixcontact.com/us/products/2904504
Monitoring module - MINI MCR-2-FM-RC - 2904504
Accessories
Device marking
Marker for end clamp - UCT-EM (30X5) - 0801505
Marker for end clamp, Sheet, white, unlabeled, can be labeled with: TOPMARK NEO, TOPMARK LASER,
BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, THERMOMARK PRIME, THERMOMARK CARD 2.0,
THERMOMARK CARD, mounting type: snapped into marker carrier, lettering field size: 30 x 5 mm, Number of individual
labels: 24
Marker for end clamp - UCT-EM (30X5) YE - 0830340
Marker for end clamp, Sheet, yellow, unlabeled, can be labeled with: TOPMARK NEO, TOPMARK LASER,
BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, THERMOMARK PRIME, THERMOMARK CARD 2.0,
THERMOMARK CARD, mounting type: snapped into marker carrier, lettering field size: 30 x 5 mm, Number of individual
labels: 24
Plastic label - UC-EMLP (15X5) - 0819301
Plastic label, Sheet, white, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED,
PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels:
10
Plastic label - UC-EMLP (15X5) YE - 0822615
Plastic label, Sheet, yellow, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED,
PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels:
10
Plastic label - UC-EMLP (15X5) SR - 0828095
Plastic label, Sheet, silver, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED,
PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels:
10
06/14/2020 Page 7 / 11
https://www.phoenixcontact.com/us/products/2904504
Monitoring module - MINI MCR-2-FM-RC - 2904504
Accessories
Plastic label - US-EMLP (15X5) - 0828790
Plastic label, Card, white, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK
PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 15 x 5 mm,
Number of individual labels: 189
Plastic label - US-EMLP (15X5) YE - 0828873
Plastic label, Card, yellow, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK
PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 15 x 5 mm,
Number of individual labels: 189
Plastic label - US-EMLP (15X5) SR - 0828874
Plastic label, Card, silver, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK
PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 15 x 5 mm,
Number of individual labels: 189
DIN rail connector
DIN rail bus connectors - ME 6,2 TBUS-2 1,5/5-ST-3,81 GY - 2695439
DIN rail connector (TBUS), 5-pos., for bridging the supply voltage, can be snapped onto NS 35/... DIN rails according to
EN 60715
DIN rail bus connectors - ME 6,2 TBUS-2 1,5/5-ST-3,81 GN - 2869728
DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold-plated contacts, 5-pos.
06/14/2020 Page 8 / 11
https://www.phoenixcontact.com/us/products/2904504
Monitoring module - MINI MCR-2-FM-RC - 2904504
Accessories
Labeled device marker
Marker for end clamp - UCT-EM (30X5) CUS - 0801589
Marker for end clamp, can be ordered: by sheet, white, labeled according to customer specifications, mounting type:
snapped into marker carrier, lettering field size: 30 x 5 mm, Number of individual labels: 24
Marker for end clamp - UCT-EM (30X5) YE CUS - 0830348
Marker for end clamp, can be ordered: by sheet, yellow, labeled according to customer specifications, mounting type:
snapped into marker carrier, lettering field size: 30 x 5 mm, Number of individual labels: 24
Plastic label - UC-EMLP (15X5) CUS - 0824550
Plastic label, can be ordered: by sheet, white, labeled according to customer specifications, mounting type: adhesive,
lettering field size: 15 x 5 mm
Plastic label - UC-EMLP (15X5) YE CUS - 0824551
Plastic label, can be ordered: by sheet, yellow, labeled according to customer specifications, mounting type: adhesive,
lettering field size: 15 x 5 mm
Plastic label - UC-EMLP (15X5) SR CUS - 0828099
Plastic label, can be ordered: by sheet, silver, labeled according to customer specifications, mounting type: adhesive,
lettering field size: 15 x 5 mm, Number of individual labels: 10
06/14/2020 Page 9 / 11
https://www.phoenixcontact.com/us/products/2904504
Monitoring module - MINI MCR-2-FM-RC - 2904504
Accessories
Plastic label - US-EMLP (15X5) CUS - 0830076
Plastic label, can be ordered: By card, white, labeled according to customer specifications, mounting type: adhesive,
lettering field size: 15 x 5 mm, Number of individual labels: 189
Plastic label - US-EMLP (15X5) YE CUS - 0830077
Plastic label, can be ordered: By card, yellow, labeled according to customer specifications, mounting type: adhesive,
lettering field size: 15 x 5 mm, Number of individual labels: 189
Plastic label - US-EMLP (15X5) SR CUS - 0830078
Plastic label, can be ordered: By card, silver, labeled according to customer specifications, mounting type: adhesive,
lettering field size: 15 x 5 mm, Number of individual labels: 189
Power module
Power terminal block - MINI MCR-2-PTB - 2902066
Power terminal with plug-in connection technology for delivering the supply voltage to the DIN rail connector. Monitoring
of the supply voltages in combination with the fault monitoring module. Screw connection technology
Power terminal block - MINI MCR-2-PTB-PT - 2902067
Power terminal with plug-in connection technology for delivering the supply voltage to the DIN rail connector. Monitoring
of the supply voltages in combination with the fault monitoring module. Push-in connection technology
06/14/2020 Page 10 / 11
https://www.phoenixcontact.com/us/products/2904504
Monitoring module - MINI MCR-2-FM-RC - 2904504
Accessories
Power supply
Power supply unit - MINI-SYS-PS-100-240AC/24DC/1.5 - 2866983
Primary-switched MINI POWER supply for DIN rail mounting, input: 1-phase, output: 24 V DC/1.5 A
Power supply unit - MINI-PS-100-240AC/24DC/1.5/EX - 2866653
Primary-switched power supply MINI POWER for DIN rail mounting, input: 1-phase, output: 24 V DC/1,5 A, for the
potentially explosive area
System adapter
System adapter - MINI MCR-2-V8-FLK 16 - 2901993
Eight MINI Analog Pro signal conditioners and measuring transducers can be connected to a controller with minimal
cabling effort and without any errors using system adapters and system cabling.
Terminal marking
Marker strip - SK 5,0 WH:REEL - 0805221
Marker strip, Roll, white, unlabeled, can be labeled with: THERMOMARK ROLL 2.0, THERMOMARK ROLL,
THERMOMARK ROLL X1, THERMOMARK ROLLMASTER 300/600, THERMOMARK X1.2, mounting type: adhesive, for
terminal block width: 5 mm, lettering field size: continuous x 5 mm, Number of individual labels: 90000
Phoenix Contact 2020 © - all rights reserved
http://www.phoenixcontact.com
06/14/2020 Page 11 / 11