https://www.phoenixcontact.com/in/products/2904607
Power supply unit - QUINT4-PS/1AC/12DC/7.5/PT - 2904607
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Primary-switched power supply unit, QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase,
output: 12 V DC / 7.5 A
Your advantages
Starting of heavy loads with dynamic boost
Preventive function monitoring indicates critical operating states before errors occur
High efficiency and long service life, with low power dissipation and low heating
Space savings in the control cabinet, thanks to a narrow, slim-line design
Fast and easy startup, thanks to tool-free Push-in connection technology
Key Commercial Data
Packing unit
1 pc
GTIN
GTIN
4055626255767
Weight per Piece (excluding packing)
370.700 g
Custom tariff number
85044030
Country of origin
Germany
Technical data
Dimensions
Width
45 mm
Height
106 mm
Depth
90 mm
Installation distance right/left (active, passive)
0 mm / 0 mm (POut ≤50 %)
Installation distance right/left (passive)
5 mm / 5 mm (POut ≥50% )
Installation distance right/left (active)
15 mm / 15 mm (POut ≥50% )
Installation distance top/bottom (active, passive)
30 mm / 30 mm (POut ≤50 %)
Installation distance top/bottom (passive)
30 mm / 30 mm (POut ≥50% )
06/17/2020 Page 1 / 12
https://www.phoenixcontact.com/in/products/2904607
Power supply unit - QUINT4-PS/1AC/12DC/7.5/PT - 2904607
Technical data
Dimensions
Installation distance top/bottom (active)
30 mm / 30 mm (POut ≥50% )
Ambient conditions
Degree of protection
IP20
Inflammability class in acc. with UL 94 (housing / terminal blocks)
V0
Ambient temperature (operation)
-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (start-up type tested)
-40 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Max. permissible relative humidity (operation)
≤ 95 % (at 25 °C, non-condensing)
Climatic class
3K3 (in acc. with EN 60721)
Degree of pollution
2
Installation height
≤ 5000 m (> 2000 m, observe derating)
Input data
Input voltage range
100 V AC ... 240 V AC -15 % ... +10 %
110 V DC ... 250 V DC -20 % ... +40 %
Dielectric strength maximum
300 V AC 60 s
Frequency range (fN)
50 Hz ... 60 Hz -10 % ... +10 %
Discharge current to PE
< 0.25 mA (264 V AC, 60 Hz)
Current consumption
1 A (100 V AC)
0.85 A (120 V AC)
0.46 A (230 V AC)
0.44 A (240 V AC)
Nominal power consumption
96.3 VA
Inrush current
typ. 11.4 A (at 25 °C)
Mains buffering time
typ. 48 ms (120 V AC)
typ. 48 ms (230 V AC)
Input fuse
3.15 A (slow-blow, internal)
Recommended breaker for input protection
6 A ... 16 A (Characteristic B, C or comparable)
Type of protection
Transient surge protection
Protective circuit/component
Varistor
Output data
Nominal output voltage
12 V DC
Setting range of the output voltage (USet)
12 V DC ... 15 V DC (constant capacity)
Nominal output current (IN)
7.5 A
Dynamic Boost (IDyn.Boost)
12.75 A (≤ 60 °C (5 s))
Connection in parallel
Yes, for redundancy and increased capacity
Connection in series
yes
Feedback voltage resistance
≤ 25 V DC
Protection against overvoltage at the output (OVP)
≤ 18 V DC
Control deviation
< 0.3 % (Static load change 10 % ... 90 %)
06/17/2020 Page 2 / 12
https://www.phoenixcontact.com/in/products/2904607
Power supply unit - QUINT4-PS/1AC/12DC/7.5/PT - 2904607
Technical data
Output data
< 3 % (Dynamic load change 10 % ... 90 %, (10 Hz))
< 0.1 % (change in input voltage ±10 %)
Residual ripple
< 35 mVPP (with nominal values)
Output power
90 W
Typical response time
300 ms
Maximum power dissipation in no-load condition
< 0.6 W (230 V AC)
< 0.6 W (120 V AC)
Power loss nominal load max.
< 8.1 W (120 V AC)
< 7.1 W (230 V AC)
General
Net weight
0.3 kg
Efficiency
typ. 91.5 % (120 V AC)
typ. 92.5 % (230 V AC)
MTBF (IEC 61709, SN 29500)
> 1221000 h (25 °C)
> 671000 h (40 °C)
> 248000 h (60 °C)
Insulation voltage input/output
4 kV AC (type test)
3 kV AC (routine test)
Degree of protection
IP20
Protection class
II
Inflammability class in acc. with UL 94 (housing / terminal blocks)
V0
Connection data, input
Connection method
Push-in connection
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
14
Stripping length
10 mm
Connection data, output
Connection method
Push-in connection
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
14
Stripping length
10 mm
06/17/2020 Page 3 / 12
https://www.phoenixcontact.com/in/products/2904607
Power supply unit - QUINT4-PS/1AC/12DC/7.5/PT - 2904607
Technical data
Connection data for signaling
Connection method
Push-in connection
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
14
Stripping length
10 mm
Standards
Standard - Safety of transformers
EN 61558-2-16
Standard - safety for equipment for measurement, control, and
laboratory use
IEC 61010-1
Standard – Safety extra-low voltage
IEC 61010-1 (SELV)
IEC 61010-2-201 (PELV)
Standard - Safe isolation
IEC 61558-2-16
Standard – Limitation of mains harmonic currents
EN 61000-3-2
Conformance/approvals
UL approvals
UL Listed UL 61010-1
UL Listed UL 61010-2-201
ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous
Location)
SIQ
CB-Scheme (IEC 61010-1, IEC 61010-2-201)
EMC data
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Conducted noise emission
EN 55016
EN 61000-6-3 (Class B)
Noise emission
EN 55016
EN 61000-6-3 (Class B)
Harmonic currents
EN 61000-3-2
EN 61000-3-2 (Class A)
Flicker
EN 61000-3-3
Electrostatic discharge
EN 61000-4-2
Contact discharge
8 kV (Test Level 4)
Discharge in air
15 kV (Test Level 4)
Electromagnetic HF field
EN 61000-4-3
Frequency range
80 MHz ... 1 GHz
Test field strength
20 V/m (Test Level 3)
Frequency range
1 GHz ... 6 GHz
Test field strength
10 V/m (Test Level 3)
Comments
Criterion A
06/17/2020 Page 4 / 12
https://www.phoenixcontact.com/in/products/2904607
Power supply unit - QUINT4-PS/1AC/12DC/7.5/PT - 2904607
Technical data
EMC data
Fast transients (burst)
EN 61000-4-4
Input
4 kV (Test Level 4 - asymmetrical)
Output
4 kV (Test Level 4 - asymmetrical)
Signal
4 kV (Test Level 4 - asymmetrical)
Comments
Criterion A
Surge voltage load (surge)
EN 61000-4-5
Input
2 kV (Test Level 4 - symmetrical)
4 kV (Test Level 4 - asymmetrical)
Output
1 kV (Test Level 3 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Signal
0.5 kV (Test Level 2 - symmetrical)
Comments
Criterion A
I/O/S
asymmetrical
Frequency range
0.15 MHz ... 80 MHz
Voltage
10 V (Test Level 3)
Comments
Criterion A
Frequency
16.67 Hz
50 Hz
60 Hz
Test field strength
100 A/m
Additional text
60 s
Comments
Criterion A
Frequency
50 Hz
60 Hz
Test field strength
1 kA/m
Additional text
3s
Frequency
0 Hz
Test field strength
300 A/m
Additional text
DC, 60 s
Voltage dips
EN 61000-4-11
Voltage
100 V AC
Frequency
60 Hz
Voltage dip
70 %
Number of periods
0.5 / 1 / 30 periods
Additional text
Test Level 2
Comments
Criterion A
Voltage dip
40 %
Number of periods
5 / 10 / 50 periods
Additional text
Test Level 2
Comments
Criterion B
06/17/2020 Page 5 / 12
https://www.phoenixcontact.com/in/products/2904607
Power supply unit - QUINT4-PS/1AC/12DC/7.5/PT - 2904607
Technical data
EMC data
Voltage dip
0%
Number of periods
0.5 / 1 / 5 / 50 periods
Additional text
Test Level 2
Comments
Criterion B
Pulse-shape magnetic field
EN 61000-4-9
Test field strength
1000 A/m
Comments
Criterion A
Attenuated sinusoidal oscillations (ring wave)
EN 61000-4-12
Input
2 kV (symmetrical)
4 kV (asymmetrical)
Comments
Criterion A
Asymmetrical conducted disturbance variables
EN 61000-4-16
Test level 1
16.67 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
Voltage
30 V (10 s)
Test level 2
16.67 Hz 50 Hz 60 Hz (Test Level 2)
Voltage
300 V (1 s)
Comments
Criterion A
Attenuated oscillating wave
EN 61000-4-18
Voltage
1 kV (symmetrical)
2.5 kV (asymmetrical)
1 kV (symmetrical)
Comments
Criterion A
Criterion A
Normal operating behavior within the specified limits.
Criterion B
Temporary impairment to operational behavior that is corrected by the
device itself.
Criterion C
Temporary adverse effects on the operating behavior, which the
device corrects automatically or which can be restored by actuating the
operating elements.
Drawings
06/17/2020 Page 6 / 12
https://www.phoenixcontact.com/in/products/2904607
Power supply unit - QUINT4-PS/1AC/12DC/7.5/PT - 2904607
Schematic diagram
06/17/2020 Page 7 / 12
https://www.phoenixcontact.com/in/products/2904607
Power supply unit - QUINT4-PS/1AC/12DC/7.5/PT - 2904607
Diagram
Diagram
06/17/2020 Page 8 / 12
https://www.phoenixcontact.com/in/products/2904607
Power supply unit - QUINT4-PS/1AC/12DC/7.5/PT - 2904607
Diagram
Block diagram
Classifications
eCl@ss
eCl@ss 10.0.1
27040701
eCl@ss 5.1
27242213
eCl@ss 6.0
27049000
06/17/2020 Page 9 / 12
https://www.phoenixcontact.com/in/products/2904607
Power supply unit - QUINT4-PS/1AC/12DC/7.5/PT - 2904607
Classifications
eCl@ss
eCl@ss 7.0
27049002
eCl@ss 8.0
27049002
eCl@ss 9.0
27040701
ETIM
ETIM 5.0
EC002540
ETIM 6.0
EC002540
ETIM 7.0
EC002540
UNSPSC
UNSPSC 13.2
39121004
UNSPSC 18.0
39121004
UNSPSC 19.0
39121004
UNSPSC 20.0
39121004
UNSPSC 21.0
39121004
Approvals
Approvals
Approvals
UL Listed / IECEE CB Scheme / cUL Listed / EAC / DNV GL / cULus Listed
Ex Approvals
UL Listed / cUL Listed / cULus Listed
Approval details
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 123528
IECEE CB Scheme
http://www.iecee.org/
SI-7008
cUL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 123528
06/17/2020 Page 10 / 12
https://www.phoenixcontact.com/in/products/2904607
Power supply unit - QUINT4-PS/1AC/12DC/7.5/PT - 2904607
Approvals
EAC
RU*DE*08.B.01873/19
DNV GL
https://approvalfinder.dnvgl.com/
TAA00001SN
cULus Listed
Accessories
Accessories
Device protection
Type 3 surge protection device - PLT-SEC-T3-230-FM-UT - 2907919
Type 2/3 surge protection, consisting of protective plug and base element with screw connection. For single-phase
power supply network with integrated status indicator and remote signaling. Nominal voltage 230 V AC/DC.
Type 3 surge protection device - PLT-SEC-T3-24-FM-UT - 2907916
Type 3 surge protection, consisting of protective plug and base element, with integrated status indicator and remote
signaling for single-phase power supply networks. Nominal voltage 24 V AC/DC.
Type 3 surge protection device - PLT-SEC-T3-230-FM-PT - 2907928
Type 2/3 surge protection, consisting of protective plug and base element with Push-in connection. For single-phase
power supply network with integrated status indicator and remote signaling. Nominal voltage 230 V AC/DC.
06/17/2020 Page 11 / 12
https://www.phoenixcontact.com/in/products/2904607
Power supply unit - QUINT4-PS/1AC/12DC/7.5/PT - 2904607
Accessories
Type 3 surge protection device - PLT-SEC-T3-24-FM-PT - 2907925
Type 3 surge protection, consisting of protective plug and base element, with integrated status indicator and remote
signaling for single-phase power supply networks. Nominal voltage 24 V AC/DC.
Screwdriver tools
Screwdriver - SF-SL 0,4X2,0-60 - 1212546
Screwdriver, flat bladed, size: 0.4 x 2.0 x 60 mm, 2-component grip, with non-slip grip
Phoenix Contact 2020 © - all rights reserved
http://www.phoenixcontact.com
06/17/2020 Page 12 / 12
很抱歉,暂时无法提供与“2904607”相匹配的价格&库存,您可以联系我们找货