    2-CHANNEL EX I OUTPUT SIGNAL CON

  • 数据手册
  • 价格&库存
2904931 数据手册
MACX MCR-EX-IDS-2I-2I(-SP) Output signal conditioner, Ex i, 2-channel Data sheet 109174_en_02 1 © PHOENIX CONTACT 2021-05-20 Description The 2-channel output signal conditioner is used for controlling the intrinsically safe (Ex i) I/P converters, regulating valves, and indicators installed in the Ex area. Features For operating the intrinsically safe SMART actuators, the analog measuring value can be overlayed with digital communication signals (HART) on the Ex or non-Ex side and transmitted bidirectionally in an electrically isolated manner. – – – – – – – – Sockets are integrated into the COMBICON connectors for connecting HART (HHT) communicators. – The device enables open-circuit and short-circuit monitoring. – An open or short-circuited field circuit causes a high input impedance on the controller side, thus enabling open-circuit and short-circuit monitoring via the control system. – – The device isolates and transmits 0.2/4 mA ... 20 mA signals to the Ex area in an with intrinsic safety. Readiness for operation is indicated via a green LED. The device is approved for safety-related applications up to SIL 2 (1oo1) / SIL 3 (1oo2). – – 2-channel Input 0.2/4 mA ... 20 mA Output 0.2/4 mA ... 20 mA, intrinsically safe [Ex ia] Output load up to 700 Ω Bidirectional HART signal transmission Short circuit monitoring Line break monitoring Up to SIL 2 (1oo1) / SIL 3 (1oo2) in accordance with IEC/EN 61508 Safe electrical isolation between input, output, and supply Energy supply and error indication possible via DIN rail connector Installation in Ex zone 2 permitted Plug-in connection terminal blocks, either screw or spring-cage connection technology (Push-in technology) Housing width of 12.5 mm High transmission accuracy WARNING: Explosion hazard The device is an item of associated equipment with an EPL [Ga], [Da] (ATEX category 1) with "intrinsic safety" type of protection and can be installed in zone 2 potentially explosive areas as an EPL Gc (ATEX category 3) device. Intrinsically safe circuits can be led up to zone 0/zone 20. It satisfies the requirements of the following standards. Comprehensive details are to be found in the EU Declaration of Conformity, which is enclosed and also available on our website in the latest version: IEC/EN 60079-0, IEC/EN 60079-7, IEC/EN 60079-11 When installing and operating the device, the applicable safety directives (including national safety directives), accident prevention regulations, as well as general technical regulations must be observed. Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products. This document is valid for the products listed in the “Ordering data”. MACX MCR-EX-IDS-2I-2I(-SP) 2 Table of contents 1 Description .............................................................................................................................. 1 2 Table of contents ..................................................................................................................... 2 3 Ordering data .......................................................................................................................... 3 4 Technical data ......................................................................................................................... 5 5 Safety regulations and installation notes................................................................................ 10 5.1 Installation notes ............................................................................................................... 10 5.2 Intrinsic safety ................................................................................................................... 10 5.3 Installation in Zone 2........................................................................................................... 10 5.4 Potentially dust-explosive areas ............................................................................................ 11 5.5 UL note ........................................................................................................................... 11 5.6 Safety-related applications (SIL) ............................................................................................ 11 6 Installation ............................................................................................................................. 12 6.1 Connection notes .............................................................................................................. 12 6.2 Electrostatic discharge ........................................................................................................ 12 6.3 Structure ......................................................................................................................... 12 6.4 Basic circuit diagram with connection terminal blocks ................................................................. 13 6.5 Input ............................................................................................................................... 13 6.6 Output (intrinsically safe) ..................................................................................................... 13 6.7 Power supply .................................................................................................................... 13 6.8 Dimensions ...................................................................................................................... 13 6.9 Mounting ......................................................................................................................... 14 6.10 Connecting the cables ........................................................................................................ 14 6.11 Startup ............................................................................................................................ 14 7 Comparison of the safety data ............................................................................................... 15 8 Safety-related applications .................................................................................................... 16 8.1 Safety function .................................................................................................................. 16 8.2 Safety integrity requirements ................................................................................................ 17 8.3 Conditions ....................................................................................................................... 20 8.4 Installation and startup ........................................................................................................ 20 8.5 Notes on operation ............................................................................................................. 21 8.6 Recurring checks ............................................................................................................... 21 8.7 Repair ............................................................................................................................. 21 8.8 Standards ........................................................................................................................ 22 8.9 Abbreviations ................................................................................................................... 22 109174_en_02 PHOENIX CONTACT 2/22 MACX MCR-EX-IDS-2I-2I(-SP) 3 Ordering data Description Type Order No. Pcs./Pkt. 2865421 1 2-channel Ex i output signal conditioner, HART. Isolates MACX MCR-EX-IDS-2I-2I-SP 2904931 and transmits 0/420 mA signals with intrinsic safety to a load in the Ex area. Galvanic 4-way electrical isolation, line fault detection, SIL 2 (SC3) in accordance with IEC 61508, Push-in connection. 1 Accessories Pcs./Pkt. 2-channel Ex i output signal conditioner, HART. Isolates MACX MCR-EX-IDS-2I-2I and transmits 0/420 mA signals with intrinsic safety to a load in the Ex area. Galvanic 4-way electrical isolation, line fault detection, SIL 2 (SC3) in accordance with IEC 61508, screw connection. Type Order No. DIN rail connector (TBUS), 5-pos., for bridging the supply ME 6,2 TBUS-2 1,5/5-ST-3,81 2695439 voltage, can be snapped onto NS 35/... DIN rails GY according to EN 60715 10 Power and fault signaling module with screw connection, MACX MCR-PTB including corresponding ME 17,5 TBUS 1,5/ 5-ST-3,81 GY DIN rail connector 2865625 1 Power and fault signaling module with Push-in connection, including corresponding ME 17,5 TBUS 1,5/ 5-ST-3,81 GY DIN rail connector MACX MCR-PTB-SP 2924184 1 Universal termination carrier for connecting 16 MACX Analog Ex i signal conditioners to digital or analog I/O cards, via D-SUB connector, 37-pos. (1:1 connection), with HART multiplexer connection TC-D37SUB-AIO16-EX-PSUNI 2902932 1 Universal termination carrier for connecting 16 MACX Analog Ex i signal conditioners to digital or analog I/O cards, via D-SUB connector, 37-pos. (1:1 connection) TC-D37SUB-ADIO16-EX-PUNI 2924854 1 Insulating sleeve, color: white MPS-IH WH 0201663 10 Insulating sleeve, color: red MPS-IH RD 0201676 10 Insulating sleeve, color: blue MPS-IH BU 0201689 10 Insulating sleeve, color: yellow MPS-IH YE 0201692 10 Insulating sleeve, color: green MPS-IH GN 0201702 10 Insulating sleeve, color: gray MPS-IH GY 0201728 10 Insulating sleeve, color: black MPS-IH BK 0201731 10 Test plugs, with solder connection up to 1 mm² conductor MPS-MT cross section, color: gray 0201744 10 Plastic label, Sheet, white, unlabeled, can be labeled with: UC-EMLP (11X9) BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 10 0819291 10 109174_en_02 PHOENIX CONTACT 3/22 MACX MCR-EX-IDS-2I-2I(-SP) Accessories Type Order No. Pcs./Pkt. Plastic label, Sheet, yellow, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 10 UC-EMLP (11X9) YE 0822602 10 Plastic label, can be ordered: by sheet, white, labeled according to customer specifications, mounting type: adhesive, lettering field size: 11 x 9 mm UC-EMLP (11X9) CUS 0824547 1 Plastic label, can be ordered: by sheet, yellow, labeled according to customer specifications, mounting type: adhesive, lettering field size: 11 x 9 mm UC-EMLP (11X9) YE CUS 0824548 1 Plastic label, Sheet, silver, unlabeled, can be labeled with: UC-EMLP (11X9) SR BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 10 0828094 10 Plastic label, can be ordered: by sheet, silver, labeled according to customer specifications, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 10 0828098 1 Plastic label, Card, white, unlabeled, can be labeled with: US-EMLP (11X9) BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 135 0828789 10 Plastic label, Card, yellow, unlabeled, can be labeled with: US-EMLP (11X9) YE BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 135 0828871 10 Plastic label, Card, silver, unlabeled, can be labeled with: US-EMLP (11X9) SR BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 135 0828872 10 Device marker, Sheet, white, unlabeled, can be labeled LS-EMLP (11X9) WH with: TOPMARK NEO, TOPMARK LASER, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 255 0831678 10 Device marker, Sheet, silver, unlabeled, can be labeled LS-EMLP (11X9) SR with: TOPMARK NEO, TOPMARK LASER, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 255 0831705 10 Device marker, Sheet, yellow, unlabeled, can be labeled LS-EMLP (11X9) YE with: TOPMARK NEO, TOPMARK LASER, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 255 0831732 10 109174_en_02 UC-EMLP (11X9) SR CUS PHOENIX CONTACT 4/22 MACX MCR-EX-IDS-2I-2I(-SP) 4 Technical data Input data Current input signal 0.2 mA ... 20 mA (Function) 4 mA ... 20 mA (Safety) 0 mA ... 24 mA (Underload/overload range) Input current ≤ 30 mA Input impedance in the event of a line fault at the output > 1 MΩ (If there is a line fault) Line fault detection Response threshold of input current >0.2 mA Voltage drop < 2.4 V (at 20 mA) Output Output description Current output intrinsically safe Current output signal 0.2 mA ... 20 mA (Function) 4 mA ... 20 mA (Safety) 0 mA ... 24 mA (Underload/overload range) Transmission Behavior 1:1 to input signal Load 100 Ω ... 700 Ω (20 mA) 100 Ω ... 650 Ω (20.5 mA) 100 Ω ... 500 Ω (24 mA) Output ripple < 20 mVrms Non-load voltage ≤ 27 V Wire-break detection Load >10 kΩ Short-circuit detection Load  30 V DC, usable in DC circuits, slow-blow) in the installation. To protect the device against mechanical or electrical damage, install it in suitable housing with an appropriate degree of protection according to IEC/EN  60529. During maintenance work, disconnect the device from all effective power sources. If the device is not used as described in the documentation, the intended protection can be negatively affected. Thanks to its housing, the device has basic insulation to the neighboring devices, for 300 Veff. If several devices are installed next to each other, this has to be taken into account, and additional insulation has to be installed if necessary! If the neighboring device is equipped with basic insulation, no additional insulation is necessary. The voltages applied at the input, output, and power supply are extra-low voltages (ELV). Depending on the application, it can be the case that a voltage that is dangerous to the touch (>30 V AC / >60 V DC) against the ground could be present on the device. In this case, a safe galvanic isolation exists between the input side and the output side. 109174_en_02 Electrostatic discharge NOTE: Electrostatic discharge The device contains components that can be damaged or destroyed by electrostatic discharge. When handling the device, observe the necessary safety precautions against electrostatic discharge (ESD) according to EN 61340-5-1 and IEC 613405-1. 6.3 Structure Figure 1 Structure 1 1.1 4 1.2 1.1 2.1 PH FlacOENI 32 hsmX CO 82 ar NT 5 Bl kts AC om tr. 8 T Gm be rg, bH Ge & Co rm .KG an y Iso lati on ww 3.1 w.ph Dri oe nix co ve r ntac t.c 3.2 / A us Iso lati 2.1 on str en tärk er 1.2 1.1 2.2 2.1 3.2 3.1 PW 2.2 3.1 ww w.ph Dri oe nix co ve r ntac t.c 3.2 om / A us ga ng nve rs 1.2 PH FlacOENI 32 hsmX CO 82 ar NT 5 Bl kts AC om tr. 8 T Gm be rg, bH Ge & Co rm .KG an y om ga 3 2.2 ng str en nve rs tärk er R PW 4.2 4.1 5.2 5.1 1 2 3 4 1.2 1.1 2.2 2.1 3.2 3.1 2 R 4.2 4.1 5.2 5.1 COMBICON plug-in, screw, or push-in connection terminal with integrated test socket Green “PWR” LED, power supply Snap-on foot for DIN rail mounting Connection for DIN rail connector PHOENIX CONTACT 12/22 MACX MCR-EX-IDS-2I-2I(-SP) 6.4 Basic circuit diagram with connection terminal blocks Figure 2 Basic circuit diagram Sensor / Field OUT - 4.2 P + 4.1 P 5.2 + - CH1 3.1 5.2 2.2 – – 6.6 – – Never connect the supply voltage directly to the DIN rail connector. It is not permitted to draw power from the DIN rail connector or from individual modules. + - 2.2 + Supply via the MACX Analog Ex module 2.1 1.2 1.1 Where the total current consumption of the aligned modules does not exceed 400 mA, the power can be supplied directly at the connection terminal blocks of the module. Up to 16 modules can be supplied depending on the current consumption of the modules. GND +24V Div. 1,2 6.5 3.2 + +24V NOTE 3.1 2.1 Power Zone 0,1,2 Zone 20,21,22 + 4.1 GND The supply voltage can be supplied via terminal points 1.1 and 1.2 or via the DIN rail connector. AO 3.2 CH2 + + 5.1 5.1 Power supply PLC / DCS IN 4.2 6.7 Zone 2 Div. 2 We recommend connecting a 630 mA fuse (normal-blow or slow-blow) upstream. Input Channel 1 on terminal blocks 3.1 (+) and 3.2 (-) Channel 2 on terminal blocks 2.1 (+) and 2.2 (-) Output (intrinsically safe) Channel 1 on terminal blocks 4.1 (+) and 4.2 (-) Channel 2 on terminal blocks 5.1 (+) and 5.2 (-) Supply via power and error message module The MACX MCR-PTB (Order No. 2865625) or the MACX MCR-PTB-SP (Order No. 2924184) supply and error message module is used to provide the supply voltage to the DIN rail connector. Simple or redundant diode-decoupled power supply is possible. Depending on the current consumption of the modules, up to 150 individual modules can be supplied by a supply that is protected by a fuse. The module has integrated error evaluation. An auxiliary supply failure or fuse fault is indicated at a relay contact and displayed via a flashing LED. 6.8 Dimensions Figure 3 Dimensions 116 (SP) 112,5 12,5 7 114,5 99 109174_en_02 PHOENIX CONTACT 13/22 MACX MCR-EX-IDS-2I-2I(-SP) 6.9 Mounting Figure 4  6.10 Mounting and removing   Connecting the cables Screw Connection Figure 5 Screw connection AWG 24-14 2 0,2-2,5 mm MACX MCR-... A 7 mm B • • • • • • • Mount the device on a 35 mm DIN rail according to EN 60715. When using the DIN rail connector, first insert it in the 35 mm DIN rail according to EN 60715 (A - C). DIN rails with a height of 7.5 mm or more can be used. The DIN rail connector is used to bridge the power supply and communication. The snap-in direction of the device and DIN rail connector must be observed: snap-on foot on the bottom and plug on the left. Install the module in a suitable housing to meet the requirements for the protection class. Strip the wire by approximately 7 mm and crimp ferrules to the end of the wires. Insert the wire into the corresponding connection terminal block. Use a screwdriver to tighten the screw in the opening above the connection terminal block. Tightening torque: 0.6 Nm Push-in connection: Figure 6 • • • • Push-in connection Strip the wire by approximately 8 mm and crimp ferrules to the end of the wires. Insert the wire into the corresponding connection terminal block. Push in the pushbutton with a screwdriver to release. 6.11 109174_en_02 0,5-0,6 Nm 5-7 lb In Startup Before startup, check that the device is operating and wired correctly, in particular with regard to the wiring and marking of the intrinsically safe circuits. PHOENIX CONTACT 14/22 MACX MCR-EX-IDS-2I-2I(-SP) 7 Comparison of the safety data WARNING: Explosion hazard Compare the safety data before connecting a device located in the Ex i area to this device. Proof of intrinsic safety (mixed intrinsically safe circuit) Condition for the mixed intrinsically safe circuit with external concentrated capacitances (Ci) and/or external concentrated inductances (Li): – Li 
2904931 价格&库存

很抱歉,暂时无法提供与“2904931”相匹配的价格&库存,您可以联系我们找货

免费人工找货