0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2904964

2904964

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    TRANSDUCERMEASURING

  • 数据手册
  • 价格&库存
2904964 数据手册
https://www.phoenixcontact.com/us/products/2904964 Repeater power supply - MACX PL-EX-RPSS-2I-2I-SP - 2904964 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Ex i measuring transducer repeater power supply, 2-channel; HART-transparent. Supplies Ex i 2-wire measuring transducers and transmits the 4 - 20 mA signal from the Ex area to the safe area. 5-way electrical isolation, PLd, spring-cage connection. The figure shows a version with a screw connection Product Features     Key commercial data Packing unit 1 pc Custom tariff number 85437090 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 12.5 mm Height 99 mm Depth 114.5 mm Ambient conditions Ambient temperature (operation) -20 °C ... 60 °C (Any mounting position) Ambient temperature (storage/transport) -40 °C ... 80 °C Maximum altitude ≤ 2000 m Permissible humidity (operation) 10 % ... 95 % (non-condensing) Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. 05/18/2015   Page 1 / 5 https://www.phoenixcontact.com/us/products/2904964 Repeater power supply - MACX PL-EX-RPSS-2I-2I-SP - 2904964 Technical data Ambient conditions Degree of protection IP20 Input data Signal input Intrinsically safe Current input signal 4 mA ... 20 mA Transmitter supply voltage > 16 V (at 20 mA) Output data Signal output Current output Current output signal 4 mA ... 20 mA (active) Transmission Behavior 1:1 to input signal Load/output load current output ≤ 450 Ω (20 mA) ≤ 375 Ω (24 mA) Output behavior in the event of an error < 3.6 mA (In the event of cable break at the input (as per NE 43)) > 22.5 mA (In the event of cable short circuit at the input (as per NE 43)) Power supply Nominal supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC (24 V DC (-20% ... +25%)) Max. current consumption < 100 mA (24 V / 20 mA) Power consumption < 1.4 W (at 24 V DC / 20 mA) Connection data Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 16 Stripping length 8 mm Connection method Push-in connection General Maximum transmission error < 0.1 % (of final value) Transmission error, typical < 0.05 % (of final value) Maximum temperature coefficient < 0.01 %/K Step response (10-90%) < 1.3 ms (for 4 mA ... 20 mA step) Status display Green LED (supply voltage) Inflammability class according to UL 94 V0 Pollution degree 2 05/18/2015   Page 2 / 5 https://www.phoenixcontact.com/us/products/2904964 Repeater power supply - MACX PL-EX-RPSS-2I-2I-SP - 2904964 Technical data General Surge voltage category II Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Emitted interference EN 61000-6-4 Color yellow Electrical isolation 300 Vrms (Rated insulation voltage (surge voltage category II; pollution degree 2, safe isolation as per EN 61010-1)) 2.5 kV (50 Hz, 1 min., test voltage) Designation Input/output Electrical isolation 375 V (Peak value in accordance with EN 60079-11) Designation Input/power supply Electrical isolation 375 V (Peak value in accordance with EN 60079-11) Designation Output 1/output 2/ power supply Electrical isolation 1.5 kV (50 Hz, 1 min., test voltage) Conformance CE-compliant, additionally EN 61326 ATEX  II (1) G [Ex ia Ga] IIC/IIB  II (1) D [Ex ia Da] IIIC  II 3(1) G Ex nA [ia Ga] IIC T4 Gc IECEx [Ex ia Ga] IIC/IIB [Ex ia Da] IIIC Ex nA [ia Ga] IIC T4 Gc UL, USA / Canada UL 61010 Listed Data communication (bypass) HART function Yes Protocols supported HART Safety data Max. output voltage Uo 25.2 V Max. output current Io 93 mA Max. output power Po 587 mW Group IIC Max. external inductivity Lo 2 mH Max. external capacity Co 107 nF Group IIB Max. external inductivity Lo 4 mH Max. external capacity Co 820 nF Safety-related maximum voltage Um 253 V AC (125 V DC) 05/18/2015   Page 3 / 5 https://www.phoenixcontact.com/us/products/2904964 Repeater power supply - MACX PL-EX-RPSS-2I-2I-SP - 2904964 Classifications eCl@ss eCl@ss 5.1 27210121 eCl@ss 6.0 27200206 eCl@ss 8.0 27210121 ETIM ETIM 4.0 EC002653 ETIM 5.0 EC002653 Approvals Approvals Approvals UL Listed / cUL Listed / GL / Functional Safety / cULus Listed Ex Approvals ATEX / IECEx / UL Listed / cUL Listed / cULus Listed Approvals submitted Approval details UL Listed  cUL Listed  GL  Functional Safety  05/18/2015   Page 4 / 5 https://www.phoenixcontact.com/us/products/2904964 Repeater power supply - MACX PL-EX-RPSS-2I-2I-SP - 2904964 Approvals cULus Listed  Drawings Block diagram OUT IN Sensor / Field PLC / DCS AI passive 4.2 - 4.2 CH1 + 4.1 4.1 3.2 3.2 CH1 active 3.1 3.1 HHT + HHT passive 5.2 - 5.2 CH2 + 5.1 5.1 active 2.2 2.2 CH2 2.1 HHT GND +24V 2.1 - + HHT 1.2 1.1 Power GND +24V Zone 0,1,2 Zone 20,21,22 Zone 2 Div. 1,2 Div. 1 Phoenix Contact 2015 © - all rights reserved http://www.phoenixcontact.com 05/18/2015   Page 5 / 5
2904964 价格&库存

很抱歉,暂时无法提供与“2904964”相匹配的价格&库存,您可以联系我们找货

免费人工找货