2905136

2905136

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    CONTROLLOGIC8IN8OUT24V

  • 数据手册
  • 价格&库存
2905136 数据手册
https://www.phoenixcontact.com/us/products/2905136 Controller - PLC-V8C/PT-24DC/SAM - 2905136 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) PLC logic standalone logic module with 16 I/Os for plug-in connection to 8 PLC-INTERFACE terminal blocks, cannot be extended, integrated realtime clock, connection to PC via micro USB socket, accommodates external memory block, push-in connection   Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 140.0 g Custom tariff number 85389091 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Power supply Supply voltage 24 V DC Supply voltage range 19.2 V DC ... 26.4 V DC Maximum input current at UN 120 mA Protective circuit Protection against polarity reversal Surge protection Status display Green LED Input data (digital) Number of inputs 8 (2 configurable as analog) Description of the input EN 61131-2, type 3 Input voltage 24 V DC Signal level "0" signal 11 V 10/29/2015   Page 1 / 6 https://www.phoenixcontact.com/us/products/2905136 Controller - PLC-V8C/PT-24DC/SAM - 2905136 Technical data Input data (digital) Input current "0" signal < 1 mA Input current "1" signal typ. 2.5 mA Status display Yellow LED Input data (analog) Number of inputs 2 (IN6 and IN7 are configurable as analog) Input voltage range 0 V ... 10 V Input resistance > 3.5 kΩ Input data (PLC-INTERFACE) Number of inputs ≤8 Description of the input technical data depends on the PLC used Input voltage 19 V DC Typical current consumption 4 mA Input resistance < 100 mΩ Output data Number of outputs ≤8 Nominal output voltage 24 V DC Nominal current 9 mA General Realtime clock accuracy ±2 s/d Realtime clock buffer time 24 h (Capacitor) Color green Mounting position any Assembly instructions Can be plugged onto 8 x PLC-INTERFACE Operating mode 100% operating factor Degree of protection IP20 Standards/regulations Designation Air clearances and creepage distances between the power circuits Standards/regulations DIN EN 50178 Rated insulation voltage 50 V Rated surge voltage 0.8 kV Insulation Basic insulation Pollution degree 2 Overvoltage category III Connection data (supply and digital inputs) Connection method Push-in connection 10/29/2015   Page 2 / 6 https://www.phoenixcontact.com/us/products/2905136 Controller - PLC-V8C/PT-24DC/SAM - 2905136 Technical data Connection data (supply and digital inputs) Stripping length 9 mm Conductor cross section solid 0.14 mm² ... 1.5 mm² Conductor cross section flexible 0.14 mm² ... 1.5 mm² 0.25 mm² ... 0.5 mm² (Ferrule with plastic sleeve) 0.25 mm² ... 1.5 mm² (Ferrules without plastic sleeve) AWG conductor cross section 26 ... 16 Number of connections 1 Number of positions 10 Note Device supply and 8 x inputs Connection data (programming interface) Connection method Micro USB type B Number of connections 1 Connection data (memory) Connection method S-PORT (socket) Number of connections 1 Number of positions 12 Note For connecting the memory module Ambient conditions Ambient temperature (operation) -20 °C ... 45 °C Ambient temperature (storage/transport) -20 °C ... 70 °C Max. permissible relative humidity (operation) 95 % Dimensions Width 50 mm Height 111 mm Depth 87 mm Classifications eCl@ss eCl@ss 5.1 27250313 eCl@ss 6.0 27242608 eCl@ss 8.0 27242216 ETIM ETIM 4.0 EC001417 ETIM 5.0 EC001417 10/29/2015   Page 3 / 6 https://www.phoenixcontact.com/us/products/2905136 Controller - PLC-V8C/PT-24DC/SAM - 2905136 Approvals Approvals Approvals UL Listed / cUL Listed / cULus Listed Ex Approvals Approvals submitted Approval details UL Listed  cUL Listed  cULus Listed  Drawings 10/29/2015   Page 4 / 6 https://www.phoenixcontact.com/us/products/2905136 Controller - PLC-V8C/PT-24DC/SAM - 2905136 Connection diagram Dimensional drawing 24 V 0V IN 0 IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 IN 7 24 V 0V IO 14 IO 15 IO 12 87 IO 11 IO 13 A2 13 BB 14 13 BB 14 13 BB 14 13 BB 14 IO 10 A2 A1 A2 A1 IO 9 A2 A1 A1 IO 8 PLC-V8C/.../SAM 24 V 0V 40 66 106 111 Circuit diagram Circuit diagram 24 V 24V 0V USB 0 V IN 0 IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 IN 7 Memory DI DI AI AI 24 V 0 V IN 0 IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 IN 7 DI DI AI AI Internal Logic Internal Logic 24V 24V IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IO8 IO9 IO10 IO11 IO12 IO13 IO14 IO15 A2 A2 A2 A2 13 13 13 13 IN OUT IN OUT IO8 IO9 IN OUT IO10 IN OUT IO11 IN OUT IN OUT IO12 IO13 IN OUT IO14 IN OUT IO15 IN OUT BB BB BB BB BB BB BB BB A1 A1 A1 A1 14 14 14 14 PLC-INTERFACE 24V 0V 10/29/2015   Page 5 / 6 https://www.phoenixcontact.com/us/products/2905136 Controller - PLC-V8C/PT-24DC/SAM - 2905136 Circuit diagram Circuit diagram A1 230 V N BB A2 PLC-V8C... A1 13 A2 (-) A1 24 V 0V BB A2 12 230 V N A1 A2 (-) 2966676 PLC-OSC- 24DC/ 24DC/ 2/ACT 14 2966171 PLC-RSC- 24DC/21 13 2966333 PLC-RSC-230UC/ 1AU/SEN 14 2904690 PLC-OSC-24DC/48DC/100/V8C/SEN PLC-V8C... 14 11 14 BB 13 24 V 0V Basic circuit diagram: inputs via PLC-INTERFACE with the example of one Basic circuit diagram: outputs via PLC-INTERFACE with the example of an input terminal block with relay (230 V AC) and one input terminal block with output terminal block with relay, 1 PDT, and an output terminal block with solid-state relay (24 V DC). solid-state relay. Phoenix Contact 2015 © - all rights reserved http://www.phoenixcontact.com 10/29/2015   Page 6 / 6
2905136 价格&库存

很抱歉,暂时无法提供与“2905136”相匹配的价格&库存,您可以联系我们找货

免费人工找货