0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2905139

2905139

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    电机启动器,可反向 19.2 ~ 30VDC 电源 3A 42 ~ 550V 负载

  • 数据手册
  • 价格&库存
2905139 数据手册
ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 Please be informed that the data shown in this PDF document is generated from our online catalog. Please find the complete data in the user documentation. Our general terms of use for downloads are valid. Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 3 A output current, with adjustable overload shutdown, emergency stop function to SIL 3 / PL e and push-in connection, DIN rail connector provided. Your advantages • 22.5 mm wide • Safety level in accordance with IEC 61508-1: SIL 3, ISO 13849: PL e • Reduction in wiring • Space saving • Long service life • 3-phase loop bridges • Adjustable current for bimetal function • Low-wear switching Commercial data Item number 2905139 Packing unit 1 pc Minimum order quantity 1 pc Sales key C478 Product key CK7432 Catalog page Page 24 (C-5-2019) GTIN 4046356919548 Weight per piece (including packing) 309.3 g Weight per piece (excluding packing) 282.7 g Customs tariff number 85371098 Country of origin DE Jan 8, 2024, 9:09 AM Page 1 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 Technical data Product properties Product type Hybrid motor starters Product family CONTACTRON Operating mode 100% operating factor Electrical properties Number of phases 3 Motor starter type Reversing starter Maximum power dissipation for nominal condition 2.5 W Switching frequency ≤ 2 Hz (Load-dependent) Maximum power dissipation 4.1 W Minimum power dissipation 0.88 W Coordination type 1 Supply Rated control circuit supply voltage US 24 V DC Control supply voltage range 19.2 V DC ... 30 V DC Rated control supply current IS 60 mA Protective circuit Surge protection Reverse polarity protection Insulation characteristics Rated insulation voltage 550 V Rated surge voltage 6 kV Overvoltage category III Degree of pollution 2 Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit Safe isolation (IEC 60947-1) Isolation characteristics between the control input and control supply voltage to auxiliary circuit Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC Emergency tripping Operate threshold > 33 A Response time < 0.5 s Input data Control Input name Enable input Note The enable input is compatible with signals with blanking (semiconductor output signals with test pulse with max. 3 ms duration), unblanking pulses of max. 4 ms are tolerated without adversely affecting the safety function. Rated actuating voltage UC 24 V DC Jan 8, 2024, 9:09 AM Page 2 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 Triggering voltage range 19.2 V DC ... 30 V DC Rated actuating current IC 7 mA Switching threshold 9.6 V (“0” signal) 19.2 V (“1” signal) Switching level < 5 V DC (For EMERGENCY STOP) Typical turn-off time < 30 ms Protective circuit Reverse polarity protection Output data AC output Rated operating voltage Ue 500 V AC Operating voltage range 42 V AC ... 550 V AC Rated operating current Ie 3 A (AC-51) 3 A (AC-53a) Mains frequency 50/60 Hz Load current range 180 mA ... 3 A (see to derating) Trigger characteristic in acc. with IEC 60947-4-2 Class 10 Cooling time 20 min. (for auto reset) Leakage current 0 mA Protective circuit Surge protection; Varistor Connection data Control circuits Connection method Push-in connection Stripping length 10 mm Conductor cross section rigid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 Load circuit Connection method Push-in connection Stripping length 10 mm Conductor cross section rigid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 Signaling Status display Yellow LED Operating voltage display Green LED Error indication Red LED Dimensions Width 22.5 mm Height 107.5 mm Jan 8, 2024, 9:09 AM Page 3 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 Depth 114 mm Material specifications Flammability rating according to UL 94 V0 (Housing) Environmental and real-life conditions Ambient conditions Degree of protection IP20 Ambient temperature (operation) -5 °C ... 60 °C (observe derating) Ambient temperature (storage/transport) -40 °C ... 80 °C Altitude ≤ 2000 m Approvals UKCA Certificate UKCA-compliant ATEX Identification  II (2) G [Ex eb] [Ex db] [Ex pxb]  II (2) D [Ex tb] [Ex pb] Certificate PTB 15 ATEX 3000 UL approval Certificate NLDX.E228652 NRNT.E172140 Safety Integrity Level (SIL, IEC 61508) Identification ≤ 3 Note Safe shutdown Safety Integrity Level (SIL, IEC 61508) Identification 2 Note Motor protection Performance Level (ISO 13849) Identification e Note Safe shutdown Category (ISO 13849) Identification ≤ 3 Note Safe shutdown UL data SCCR 100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault))) 5 kA (480 V AC (fuse: 20 A RK5 (standard fault))) FLA 3 A (480 V AC) Group installation 20 A (class RK5, SCCR 5kA (480 V AC), #24 - 14 AWG max. solid and stranded) Jan 8, 2024, 9:09 AM Page 4 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 30 A (class CC or J, SCCR 100kA (480 V AC), #24 - 14 AWG max, solid and stranded) Category code NLDX / NRNT Horsepower ratings 0.5 hp (208 V AC) 0.5 hp (230 V AC) 0.5 hp (240 V AC) 1.5 hp (480 V AC) Standards and regulations Standards/regulations Standards/regulations IEC 60947-1 EN 60947-4-2 IEC 61508 ISO 13849 Mounting Mounting type DIN rail mounting Assembly instructions alignable, for spacing see derating Mounting position vertical (horizontal DIN rail, motor output below) Jan 8, 2024, 9:09 AM Page 5 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 Drawings Load current [A] Diagram 9 8 7 6 5 4 3 2 1 0,18 0 10 20 30 40 50 60 70 Ambient temperature [°C] = aligned with > 20 mm spacing = aligned without spacing Derating diagram Block diagram Reset EN- EN+ Enable Logic µP + 1/L1 3/L2 5/L3 2/T1 4/T2 6/T3 T-BUS Jan 8, 2024, 9:09 AM Page 6 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 Approvals To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/2905139     IECEE CB Scheme Approval ID: DE1-60807 EAC Approval ID: RU*C-DE.*08.B.00520* UL Listed Approval ID: FILE E 172140 CCC Approval ID: 2016010304900298  cUL Listed  cUL Listed  UL Listed  Approval ID: FILE E 172140 Approval ID: FILE E 228652 Approval ID: FILE E 228652 ATEX Approval ID: PTB 15 ATEX 3000 Jan 8, 2024, 9:09 AM Page 7 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 Classifications ECLASS ECLASS-11.0 27370905 ECLASS-13.0 27370905 ECLASS-12.0 27370905 ETIM ETIM 9.0 EC001037 UNSPSC UNSPSC 21.0 25173900 Jan 8, 2024, 9:09 AM Page 8 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 Environmental product compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” Jan 8, 2024, 9:09 AM Page 9 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 Accessories BRIDGE-PT 1 - Bridge 1161777 https://www.phoenixcontact.com/us/products/1161777 3-phase loop bridge for 1 CONTACTRON module, with Push-in connection and 22.5 mm housing width, connecting cable: 3 m BRIDGE-PT 2 - Bridge 2904490 https://www.phoenixcontact.com/us/products/2904490 3-phase loop bridge for 2 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, connecting cable: 3 m Jan 8, 2024, 9:09 AM Page 10 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 BRIDGE-PT 3 - Bridge 2904491 https://www.phoenixcontact.com/us/products/2904491 3-phase loop bridge for 3 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, connecting cable: 3 m BRIDGE-PT 4 - Bridge 2904492 https://www.phoenixcontact.com/us/products/2904492 3-phase loop bridge for 4 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, connecting cable: 3 m Jan 8, 2024, 9:09 AM Page 11 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 BRIDGE-PT 5 - Bridge 2904493 https://www.phoenixcontact.com/us/products/2904493 3-phase loop bridge for 5 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, connecting cable: 3 m BRIDGE-PT 6 - Bridge 2904494 https://www.phoenixcontact.com/us/products/2904494 3-phase loop bridge for 6 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, connecting cable: 3 m Jan 8, 2024, 9:09 AM Page 12 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 BRIDGE-PT 7 - Bridge 2904495 https://www.phoenixcontact.com/us/products/2904495 3-phase loop bridge for 7 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, connecting cable: 3 m BRIDGE-PT 8 - Bridge 2904496 https://www.phoenixcontact.com/us/products/2904496 3-phase loop bridge for 8 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, connecting cable: 3 m Jan 8, 2024, 9:09 AM Page 13 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 BRIDGE-PT 9 - Bridge 2904497 https://www.phoenixcontact.com/us/products/2904497 3-phase loop bridge for 9 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, connecting cable: 3 m BRIDGE-PT 10 - Bridge 2904498 https://www.phoenixcontact.com/us/products/2904498 3-phase loop bridge for 10 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, connecting cable: 3 m Jan 8, 2024, 9:09 AM Page 14 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 BRIDGE-PT 1-1M - Bridge 1161778 https://www.phoenixcontact.com/us/products/1161778 3-phase loop bridge for 1 CONTACTRON module, with Push-in connection and 22.5 mm housing width, connecting cable: 1 m BRIDGE-PT-2-1M - Bridge 1049407 https://www.phoenixcontact.com/us/products/1049407 3-phase loop bridge for 2 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, connecting cable: 1 m Jan 8, 2024, 9:09 AM Page 15 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 BRIDGE-PT-3-1M - Bridge 1049408 https://www.phoenixcontact.com/us/products/1049408 3-phase loop bridge for 3 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, connecting cable: 1 m BRIDGE-PT-4-1M - Bridge 1049409 https://www.phoenixcontact.com/us/products/1049409 3-phase loop bridge for 4 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, connecting cable: 1 m Jan 8, 2024, 9:09 AM Page 16 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 BRIDGE-PT-5-1M - Bridge 1049413 https://www.phoenixcontact.com/us/products/1049413 3-phase loop bridge for 5 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, connecting cable: 1 m BRIDGE-PT-2-2M/0,3M - Bridge 1107649 https://www.phoenixcontact.com/us/products/1107649 3-phase loop bridge for 2 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, cable length between the modules: 0.3 m, connecting cable: 2 m Jan 8, 2024, 9:09 AM Page 17 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 BRIDGE-PT-3-2M/0,3M - Bridge 1107650 https://www.phoenixcontact.com/us/products/1107650 3-phase loop bridge for 3 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, cable length between the modules: 0.3 m, connecting cable: 2 m BRIDGE-PT-4-2M/0,3M - Bridge 1107644 https://www.phoenixcontact.com/us/products/1107644 3-phase loop bridge for 4 CONTACTRON modules, with Push-in connection and 22.5 mm housing width, cable length between the modules: 0.3 m, connecting cable: 2 m Jan 8, 2024, 9:09 AM Page 18 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 US-EMLP (15X5) - Plastic label 0828790 https://www.phoenixcontact.com/us/products/0828790 Plastic label, Card, white, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels: 189 UC-EMLP (15X5) - Plastic label 0819301 https://www.phoenixcontact.com/us/products/0819301 Plastic label, Sheet, white, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 15 x 5 mm, Number of individual labels: 10 Jan 8, 2024, 9:09 AM Page 19 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 ME 22,5 TBUS 1,5/ 5-ST-3,81 GY - DIN rail bus connectors 2201937 https://www.phoenixcontact.com/us/products/2201937 DIN rail connector, color: gray, nominal current: 8 A (parallel contacts), rated voltage (III/2): 125 V, number of positions: 5, pitch: 3.81 mm, mounting: DIN rail mounting, locking: without, mounting: without, type of packaging: packed in cardboard, Item with gold-plated contacts, bus connectors for connecting with electronics housings, 5 parallel contacts EM-PB-GATEWAY-IFS - Data interface 2297620 https://www.phoenixcontact.com/us/products/2297620 Gateway for the connection of up to 32 INTERFACE system devices to a higherlevel controller via PROFIBUS DP. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided. Jan 8, 2024, 9:09 AM Page 20 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 EM-CAN-GATEWAY-IFS - Data interface 2901504 https://www.phoenixcontact.com/us/products/2901504 Gateway for the connection of up to 32 INTERFACE system devices to a higherlevel controller via CANopen®. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided. EM-MODBUS-GATEWAY-IFS - Data interface 2901528 https://www.phoenixcontact.com/us/products/2901528 Gateway for the connection of up to 32 INTERFACE system devices via Modbus/TCP to a higher-level controller. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided. Jan 8, 2024, 9:09 AM Page 21 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 EM-PNET-GATEWAY-IFS - Data interface 2904472 https://www.phoenixcontact.com/us/products/2904472 Gateway for the connection of up to 32 INTERFACE system devices via PROFINET to a higher-level controller. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided. EM-ETH-GATEWAY-IFS - Data interface 2901988 https://www.phoenixcontact.com/us/products/2901988 Gateway for the connection of up to 32 INTERFACE system devices to a higherlevel controller via EtherNet/IP™. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided. Jan 8, 2024, 9:09 AM Page 22 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 EM-D-8/4-24DC-IFS - Extension module 2904473 https://www.phoenixcontact.com/us/products/2904473 For more complex applications with Interface system devices (IFS), the extension module offers digital inputs and outputs for processing additional signals in the field. Easy connection to IFS gateway via the DIN rail connector as the slave. QUINT4-SYS-PS/1AC/24DC/2.5/SC - Power supply unit 2904614 https://www.phoenixcontact.com/us/products/2904614 Primary-switched power supply, QUINT POWER, screw connection, DIN rail mounting, supply of devices possible via the TBUS DIN rail connector, protective coating, input: single-phase, output: 24 V DC/2.5 A ME 22,5 TBUS ADAPTER KMGY - DIN rail bus connectors 2201756 https://www.phoenixcontact.com/us/products/2201756 DIN rail bus adapter for ME and MEMAX, design width: 22.5 mm, 5 parallel positions, color: light gray (similar to RAL 7035) Jan 8, 2024, 9:09 AM Page 23 (24) ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter 2905139 https://www.phoenixcontact.com/us/products/2905139 Phoenix Contact 2024 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA 586 Fulling Mill Road Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com Jan 8, 2024, 9:09 AM Page 24 (24)
2905139 价格&库存

很抱歉,暂时无法提供与“2905139”相匹配的价格&库存,您可以联系我们找货

免费人工找货