2905229

2905229

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    模块

  • 描述:

    SURGEPROTECTIONMODULE264V

  • 数据手册
  • 价格&库存
2905229 数据手册
https://www.phoenixcontact.com/us/products/2905229 Type 3 surge protection device - PLT-SEC-T3-230-FM - 2905229 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Pluggable device protection, according to type 3/class III, for 1-phase power supply networks with separate N and PE (3-conductor system: L1, N, PE), with integrated surge-proof fuse and remote indication contact. Also suitable for DC applications. Product Features  Varistor-based device protection  Can be used without separate backup fuse thanks to integrated overcurrent protection  For 1-phase power supply units (AC/DC)  Pluggable  Optical status indicator via LED  With floating remote indication contact  Plugs can be checked with CHECKMASTER 2     Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 100.0 g Custom tariff number 85363030 Country of origin Germany Technical data Dimensions Height 90 mm Width 17.7 mm Depth 74.5 mm Horizontal pitch 1 Div. Ambient conditions Degree of protection IP20 Ambient temperature (operation) -40 °C ... 80 °C 09/29/2015   Page 1 / 7 https://www.phoenixcontact.com/us/products/2905229 Type 3 surge protection device - PLT-SEC-T3-230-FM - 2905229 Technical data Ambient conditions Ambient temperature (storage/transport) -40 °C ... 80 °C Altitude ≤ 2000 m (amsl (above mean sea level)) Permissible humidity (operation) 5 % ... 95 % Shock (operation) 30g (half sinus / 11 ms / 3x ±X, ±Y, ±Z) Vibration (operation) 5g (10 ... 150 Hz/20 cycles/axis/X, Y, Z) General Standards/specifications IEC 61643-11 2011 EN 61643-11 2012 IEC test classification III T3 EN type T3 IEC power supply system TT TN-S Number of ports One SPD design Combination type Mode of protection L-N L-PE N-PE (L+) - (L-) (L+/L-) - PE Mounting type DIN rail: 35 mm Color light grey RAL 7035 traffic grey A RAL 7042 Housing material PA 6.6-FR 20% GF PA 6.6-FR Pollution degree 2 Flammability rating according to UL 94 V-0 Type DIN rail module, two-section, divisible Number of positions 2 Surge protection fault message Optical, remote indicator contact Protective circuit Nominal voltage UN 230 V AC (TN-S) 230 V AC (TT - only in use with RCD) Nominal frequency fN 50 Hz (60 Hz) Maximum continuous voltage UC 264 V AC 230 V DC 09/29/2015   Page 2 / 7 https://www.phoenixcontact.com/us/products/2905229 Type 3 surge protection device - PLT-SEC-T3-230-FM - 2905229 Technical data Protective circuit Rated load current IL 26 A (30 °C) Residual current IPE ≤ 5 µA Nominal discharge current In (8/20) µs 3 kA Standby power consumption PC ≤ 275 mVA (at UREF) ≤ 300 mVA (at UC) Reference test voltage UREF 255 V AC Combination wave UOC 6 kV Voltage protection level Up (L-N) ≤ 1.35 kV Voltage protection level Up (L-PE) ≤ 1.5 kV Voltage protection level Up (N-PE) ≤ 1.5 kV TOV behavior at UT (L-N) 440 V AC (5 s / withstand mode) 440 V AC (120 min / withstand mode) TOV behavior at UT (L-PE) 440 V AC (5 s / withstand mode) 440 V AC (120 min / withstand mode) 1455 V AC (200 ms / safe failure mode) TOV behavior at UT (N-PE) 1200 V AC (200 ms / safe failure mode) Response time tA (L-N) ≤ 25 ns Response time tA (L-PE) ≤ 100 ns Response time tA (N-PE) ≤ 100 ns Short-circuit current rating ISCCR 1.5 kA AC 0.25 kA DC Max. backup fuse with branch wiring Not required Maximum backup fuse for through wiring 25 A (gG / B / C) Indicator/remote signaling Connection name Remote fault indicator contact Switching function N/C contact Operating voltage 250 V AC 125 V DC (200 mA DC) Operating current 3 A AC 1 A DC (30 V DC) Connection method Screw connection Screw thread M3 Tightening torque 0.8 Nm Stripping length 8 mm Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² 09/29/2015   Page 3 / 7 https://www.phoenixcontact.com/us/products/2905229 Type 3 surge protection device - PLT-SEC-T3-230-FM - 2905229 Technical data Indicator/remote signaling Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 4 mm² AWG conductor cross section 24 ... 12 Connection data Connection method Screw connection Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 4 mm² AWG conductor cross section 24 ... 12 (IEC) 24 ... 12 (UL) Screw thread M3 Tightening torque 0.8 Nm Stripping length 8 mm UL specifications UL class SPD type 4CA Maximum continuous operating voltage MCOV 255 V AC 230 V DC Nominal voltage 230 V DC Mode of protection L-N L-G N-G (L+) - (L-) (L+) - G (L-) - G Power distribution system 1 Nominal frequency 50/60 Hz Measured limiting voltage MLV (L-N) 1270 V Measured limiting voltage MLV (L-G) 1280 V Measured limiting voltage MLV (N-G) 1208 V Measured limiting voltage MLV (L+) - (L-) 1270 V Measured limiting voltage MLV (L+) - G 1280 V Measured limiting voltage MLV (L-) - G 1280 V Nominal discharge current In 3 kA 09/29/2015   Page 4 / 7 https://www.phoenixcontact.com/us/products/2905229 Type 3 surge protection device - PLT-SEC-T3-230-FM - 2905229 Classifications eCl@ss eCl@ss 5.1 27130801 eCl@ss 6.0 27130806 eCl@ss 8.0 27130803 ETIM ETIM 5.0 EC000942 Approvals Approvals Approvals KEMA-KEUR / CCA / IECEE CB Scheme / UL Recognized / cUL Recognized / EAC / GL / cULus Recognized Ex Approvals UL Recognized / cUL Recognized / cULus Recognized Approvals submitted Approval details KEMA-KEUR  CCA  IECEE CB Scheme  UL Recognized  09/29/2015   Page 5 / 7 https://www.phoenixcontact.com/us/products/2905229 Type 3 surge protection device - PLT-SEC-T3-230-FM - 2905229 Approvals cUL Recognized  EAC  GL  cULus Recognized  Drawings Diagram Dimensional drawing 90 17,7 I [A] 30 20 20 30 40 50 60 70 80 T [°C] 67 74,5 10 90 Nominal current depending on ambient temperature Product drawing Circuit diagram L 5 6 11 12 11 12 IN OUT PLUGTRAB T3 PLT-SEC T3-230-P 1 2 PE 3 N 4 09/29/2015   Page 6 / 7 https://www.phoenixcontact.com/us/products/2905229 Type 3 surge protection device - PLT-SEC-T3-230-FM - 2905229 Application drawing N PE L OUT 11 11 12 12 PLUGTRAB PLUGTRAB T3 T3 PLT-SEC T3-230-P PLT-SEC T3-230-P IN F1 N PE L F1 L N PE L N PE Phoenix Contact 2015 © - all rights reserved http://www.phoenixcontact.com 09/29/2015   Page 7 / 7
2905229 价格&库存

很抱歉,暂时无法提供与“2905229”相匹配的价格&库存,您可以联系我们找货

免费人工找货