https://www.phoenixcontact.com/us/products/2905251
Type 2 surge protection base element - VAL-MS 75X350/3EQ/
FM - 2905251
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Base element for type 2 arresters of the VALVETRAB MS product range, with remote indication contact. Version
for 3-mode protection of 2-wire signals.
Why buy this product
Versions with and without floating remote indication contact
3-Mode equalizer protection
Mechanical coding of all slots
Optical, mechanical status indication for the individual arresters
Type 2 consistent plug-in surge arresters
Key Commercial Data
Packing unit
1 STK
GTIN
GTIN
4046356958554
Weight per Piece (excluding packing)
300.000 g
Country of origin
Germany
Technical data
Note
Trade restriction
The products are offered exclusively for export outside the EU and the
European Economic Area.
Dimensions
Height
99 mm
Width
53.4 mm
04/13/2017 Page 1 / 5
https://www.phoenixcontact.com/us/products/2905251
Type 2 surge protection base element - VAL-MS 75X350/3EQ/
FM - 2905251
Technical data
Dimensions
Depth
65.5 mm
Horizontal pitch
3 Div.
Ambient conditions
Degree of protection
IP20
Ambient temperature (operation)
-40 °C ... 80 °C
Permissible humidity (operation)
5 % ... 95 %
Shock (operation)
25g
Vibration (operation)
5g
General
Housing material
PBT / PA
Flammability rating according to UL 94
V0
Color
black
Standards for cearances and creepage distances
EN 60664-1
EN 61643-1
Mounting type
DIN rail: 35 mm
Design
DIN rail module, two-section, divisible
Number of positions
3
Surge protection fault message
Optical, remote indicator contact
Direction of action
(L+)-PE & (L-)-PE & (L+)-(L-)
Protective circuit
IEC test classification
II
T2
Nominal voltage UN
5 V AC ... 48 V AC
Maximum continuous operating voltage UC
60 V
60 V
Maximum continuous operating voltage UC (L-PE)
230 V
Nominal frequency fN
50 Hz (60 Hz)
Rated load current IL
80 A (Serial through wiring at 16 mm²)
Residual current IPE
≤ 5 µA
Max. discharge current Imax (8/20) µs
20 kA
Max. discharge current Imax (8/20) µs maximum (L-N)
20 kA
Max. discharge current Imax (8/20) µs maximum (L-PE)
20 kA
Max. discharge current Imax (8/20) µs maximum (N-PE)
20 kA
Nominal discharge current In (8/20) µs
10 kA
04/13/2017 Page 2 / 5
https://www.phoenixcontact.com/us/products/2905251
Type 2 surge protection base element - VAL-MS 75X350/3EQ/
FM - 2905251
Technical data
Protective circuit
Nominal discharge current In (8/20) µs (L-PE)
10 kA
Voltage protection level Up
≤ 700 V
Voltage protection level Up (L-N)
≤ 1.4 kV
Voltage protection level Up (L-PE)
≤ 1500 V
Voltage protection level Up (N-PE)
≤ 1.5 kV
Voltage protection level Up (L+) - (L-)
≤ 700 V
Voltage protection level Up (L+/L-) - PE
≤ 1500 V
Response time tA
≤ 25 ns
Max. backup fuse with branch wiring
200 A (gL / gG)
Max. backup fuse with V-type through wiring
80 A (gL / gG)
Short-circuit resistance IP with max. backup fuse (effective)
25 kA
Short-circuit current rating ISCCR
10 kA (L-L)
Connection, protective circuit
Connection method
Screw connection
Connection method IN
Biconnect screw terminal block
Connection method OUT
Biconnect screw terminal block
Connection technology
Biconnect terminal block
Screw thread
M5
Tightening torque
26.5 lbf-in. ... 30 lbf-in. (UL)
Stripping length
16 mm
Conductor cross section flexible min.
1.5 mm²
Conductor cross section flexible max.
25 mm²
Conductor cross section solid min.
1.5 mm²
Conductor cross section solid max.
35 mm²
Conductor cross section AWG min.
15
Conductor cross section AWG max.
2
Conductor cross section AWG
10 ... 2 (UL)
Remote indication contact
Connection name
Remote fault indicator contact
Switching function
PDT, 1-pos.
Connection method
MC 1,5/3
Screw thread
M2
Tightening torque
0.25 Nm
4 lbf-in. (UL)
04/13/2017 Page 3 / 5
https://www.phoenixcontact.com/us/products/2905251
Type 2 surge protection base element - VAL-MS 75X350/3EQ/
FM - 2905251
Technical data
Remote indication contact
Stripping length
7 mm
Conductor cross section flexible min.
0.14 mm²
Conductor cross section flexible max.
1.5 mm²
Conductor cross section solid min.
0.14 mm²
Conductor cross section solid max.
1.5 mm²
Conductor cross section AWG min.
28
Conductor cross section AWG max.
16
Conductor cross section AWG
30 ... 14 (UL)
Maximum operating voltage Umax. AC
250 V AC
Maximum operating voltage Umax DC
30 V DC
Max. operating current Imax
1.5 A AC (250 V AC)
1.5 A DC (125 V AC)
1.5 A DC (30 V DC)
Standards and Regulations
Standards/regulations
IEC 61643-11
EN 61643-11
IEC 61643-11
EN 61643-11
Drawings
Circuit diagram
12
Dimensional drawing
14
99
11 FM
L1
58
22,5
51,5
65,5
45
L2
04/13/2017 Page 4 / 5
https://www.phoenixcontact.com/us/products/2905251
Type 2 surge protection base element - VAL-MS 75X350/3EQ/
FM - 2905251
Classifications
eCl@ss
eCl@ss 5.1
27130801
eCl@ss 6.0
27130805