    PLUG-IN LIGHTNING AND SURGE ARRE

  • 数据手册
  • 价格&库存
2905466 数据手册
https://www.phoenixcontact.com/us/products/2905466 Lightning/surge arrester combination type 1+2 - FLT-SECT1+T2-1S-350/25-FM - 2905466 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Plug-in lightning and surge arrester combination, in accordance with Type 1+2/Class I+II, for 1-phase power supply networks, with separate N and PE (L1, PE, N). Why buy this product  Directly coordinated combination of type 1 spark gap without line follow current and type 2 varistor arrester  Particularly suitable for maximum protection of sensitive devices in harsh environments  High continuous voltage of 350 V AC for 230/400 V AC networks with high voltage fluctuations  Pluggable  Low voltage protection level of 1.5 kV  Optical, mechanical status indicator  With floating remote indication contact  Plugs can be checked with CHECKMASTER 2 Key Commercial Data Packing unit 1 STK GTIN GTIN 4046356950169 Custom tariff number 85363030 Country of origin Germany Technical data Dimensions Height 95.2 mm 03/08/2017   Page 1 / 7 https://www.phoenixcontact.com/us/products/2905466 Lightning/surge arrester combination type 1+2 - FLT-SECT1+T2-1S-350/25-FM - 2905466 Technical data Dimensions Width 71.2 mm Horizontal pitch 4 Div. Ambient conditions Degree of protection IP20 (only when all terminal points are used) Ambient temperature (operation) -40 °C ... 80 °C Ambient temperature (storage/transport) -40 °C ... 80 °C Altitude ≤ 2000 m (amsl (above mean sea level)) Permissible humidity (operation) 5 % ... 95 % Shock (operation) 30g (half sinus / 11 ms / 3x ±X, ±Y, ±Z) Vibration (operation) 5g (5 - 500 Hz/2.5 h/X, Y, Z) General IEC test classification I + II T1 + T2 T1 I EN type T1 + T2 T1 IEC power supply system TN-S TT Mode of protection L-N L-PE N-PE Mounting type DIN rail: 35 mm Color light grey RAL 7035 traffic grey A RAL 7042 Housing material PA 6.6-FR 20% GF PBT-FR Degree of pollution 2 Flammability rating according to UL 94 V-0 Design DIN rail module, two-section, divisible Number of positions 2 Surge protection fault message Optical, remote indicator contact Protective circuit Nominal voltage UN 240 V AC (TN-S) 03/08/2017   Page 2 / 7 https://www.phoenixcontact.com/us/products/2905466 Lightning/surge arrester combination type 1+2 - FLT-SECT1+T2-1S-350/25-FM - 2905466 Technical data Protective circuit 240 V AC (TT) Nominal frequency fN 50 Hz (60 Hz) Maximum continuous voltage UC 350 V AC Rated load current IL 125 A (< 55 °C) Residual current IPE ≤ 0.01 mA Nominal discharge current In (8/20) µs (L-N) 25 kA Nominal discharge current In (8/20) µs (L-PE) 25 kA Nominal discharge current In (8/20) µs (N-PE) 100 kA Impulse discharge current (10/350) µs (L-N), charge 12.5 As Impulse discharge current (10/350) µs (L-N), specific energy 160 kJ/Ω Impulse discharge current (10/350) µs (L-N), peak current value Iimp 25 kA Impulse discharge current (10/350) µs (L-PE), charge 12.5 As Impulse discharge current (10/350) µs (L-PE), specific energy 160 kJ/Ω Impulse discharge current (10/350) µs (L-PE), peak current value Iimp 25 kA Impulse discharge current (10/350) µs (N-PE), charge 50 As Impulse discharge current (10/350) µs (N-PE), specific energy 2500 kJ/Ω Impulse discharge current (10/350) µs (N-PE), peak current value Iimp 100 kA Follow current interrupt rating Ifi (L-N) 25 kA (264 V AC) 3 kA (350 V AC) Follow current interrupt rating Ifi (N-PE) 100 A (350 V AC) Short-circuit current rating ISCCR 25 kA (264 V AC) 3 kA (350 V AC) Voltage protection level Up (L-N) ≤ 1.5 kV Voltage protection level Up (L-PE) ≤ 2.2 kV Voltage protection level Up (N-PE) ≤ 1.5 kV Residual voltage Ures (L-N) ≤ 1.5 kV (at In) ≤ 1.2 kV (at 10 kA) ≤ 1 kV (at 5 kA) ≤ 0.9 kV (at 3 kA) Residual voltage Ures (L-PE) ≤ 2.2 kV (at In) ≤ 2 kV (at 10 kA) ≤ 1.8 kV (at 5 kA) ≤ 1.6 kV (at 3 kA) Residual voltage Ures (N-PE) ≤ 1.5 kV (at In) ≤ 1 kV (at 10 kA) 03/08/2017   Page 3 / 7 https://www.phoenixcontact.com/us/products/2905466 Lightning/surge arrester combination type 1+2 - FLT-SECT1+T2-1S-350/25-FM - 2905466 Technical data Protective circuit ≤ 0.9 kV (at 5 kA) ≤ 0.8 kV (at 3 kA) TOV behavior at UT (L-N) 415 V AC (5 s / withstand mode) 457 V AC (120 min / safe failure mode) TOV behavior at UT (N-PE) 1200 V AC (200 ms / withstand mode) Response time tA (L-N) ≤ 25 ns Response time tA (N-PE) ≤ 100 ns Max. backup fuse with branch wiring 315 A (gG) Max. backup fuse with V-type through wiring 125 A (gG) Additional technical data Maximum discharge current Imax (8/20) µs (L-N) 50 kA Maximum discharge current Imax (8/20) µs (L-PE) 50 kA Maximum discharge current Imax (8/20) µs (N-PE) 100 kA Indicator/remote signaling Switching function PDT contact Operating voltage 12 V AC ... 250 V AC 125 V DC (200 mA DC) Operating current 10 mA AC ... 1 A AC 1 A DC (30 V DC) Connection method Plug-in/screw connection via COMBICON Screw thread M2 Tightening torque 0.25 Nm Stripping length 7 mm Conductor cross section flexible 0.14 mm² ... 1.5 mm² Conductor cross section solid 0.14 mm² ... 1.5 mm² Conductor cross section AWG 28 ... 16 Connection data Connection method Screw terminal blocks Screw thread M5 Tightening torque 4.5 Nm Stripping length 18 mm Conductor cross section flexible 2.5 mm² ... 35 mm² Conductor cross section solid 2.5 mm² ... 35 mm² Conductor cross section AWG 13 ... 2 03/08/2017   Page 4 / 7 https://www.phoenixcontact.com/us/products/2905466 Lightning/surge arrester combination type 1+2 - FLT-SECT1+T2-1S-350/25-FM - 2905466 Technical data UL specifications SPD Type 4CA Maximum continuous operating voltage MCOV (L-N) 264 V AC Maximum continuous operating voltage MCOV (L-G) 528 V AC Maximum continuous operating voltage MCOV (N-G) 264 V AC Nom. voltage 240 V AC Mode of protection L-N L-G N-G Power distribution system 1S Nominal frequency 50/60 Hz Measured limiting voltage MLV (L-N) 1340 V Measured limiting voltage MLV (L-G) 1550 V Measured limiting voltage MLV (N-G) 1080 V Nominal discharge current In (L-N) 20 kA Nominal discharge current In (L-G) 20 kA Nominal discharge current In (N-G) 20 kA UL indicator/remote signaling Operating voltage 125 V AC Operating current 1 A AC Tightening torque 4 lbf-in. Conductor cross section AWG 30 ... 14 UL connection data Conductor cross section AWG 12 ... 2 Tightening torque 40 lbf-in. Standards and Regulations Standards/regulations IEC 61643-11 2011 EN 61643-11 2012 Environmental Product Compliance REACh SVHC UV -328 25973-55-1 China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” 03/08/2017   Page 5 / 7 https://www.phoenixcontact.com/us/products/2905466 Lightning/surge arrester combination type 1+2 - FLT-SECT1+T2-1S-350/25-FM - 2905466 Approvals Approvals Approvals UL Recognized / KEMA-KEUR / cUL Recognized / CCA / IECEE CB Scheme / GL / EAC / cULus Recognized Ex Approvals Approval details UL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 330181 KEMA-KEUR    http://www.dekra-certification.com  2185820.01 cUL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 330181    NTR-NL 7348 CCA  IECEE CB Scheme    http://www.iecee.org/  NL-34357 GL    http://exchange.dnv.com/tari/  13946-15 HH EAC      RU CDE.A*30.B01561 03/08/2017   Page 6 / 7 https://www.phoenixcontact.com/us/products/2905466 Lightning/surge arrester combination type 1+2 - FLT-SECT1+T2-1S-350/25-FM - 2905466 Approvals cULus Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm   Phoenix Contact 2017 © - all rights reserved http://www.phoenixcontact.com 03/08/2017   Page 7 / 7
2905466 价格&库存

很抱歉,暂时无法提供与“2905466”相匹配的价格&库存,您可以联系我们找货

免费人工找货