Hybrid motor starter - ELR H3-IES-PT-24DC/500AC-06-T - 2906061
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Hybrid motor starter for starting 3~ AC motors up to 550 V AC, with 24 V DC input, 0.6 A output current,
emergency stop function, adjustable overload shutdown, higher transient voltage strength, and push-in
connection.
The figure shows the ELR H3-IESPT- 24DC/500AC-0,6 version
Product Features
Key commercial data
Packing unit
1 pc
Custom tariff number
85371099
Country of origin
Germany
Technical data
Input data
Input name
Device supply
Rated control supply voltage US
24 V DC (According to IEC 60947-1)
Voltage range with reference to US
0.8 ... 1.25
Rated control supply current IS
≤ 40 mA
Protective circuit
Protection against polarity reversal
Surge protection
Operating voltage display
Green LED
Status display
Yellow LED
Indication
Red LED
Input name
Control input
Rated actuating voltage UC
24 V DC
Voltage range with reference to UC
0.8 ... 1.25
Rated actuating current IC
≤ 5 mA
05/18/2015 Page 1 / 5
https://www.phoenixcontact.com/us/products/2906061
Hybrid motor starter - ELR H3-IES-PT-24DC/500AC-06-T - 2906061
Technical data
Input data
Switching level "safe off"
< 5 V DC
Protective circuit
Protection against polarity reversal
Typical response time
< 35 ms
Typical turn-off time
< 40 ms
Output data load output
Rated operating voltage Ue
500 V AC
Operating voltage range
42 V AC ... 550 V AC
Load current
max. 600 mA (see derating curve)
Min. load current
75 mA
Trigger characteristic in acc. with IEC 60947
Class 10A
Rated operating current at AC-51
0.6 A
Rated operating current at AC-53a
0.6 A
Leakage current
0 mA
Residual voltage
< 0.2 V (at Ie)
Protective circuit
Surge protection Varistor
Output data reply output
Note
Confirmation 01: floating change-over contact, signal contact
Contact type
1 PDT
Contact material
AgSnO2, hard gold-plated
Maximum switching voltage
30 V AC
36 V DC
Minimum switching voltage
100 mV AC/DC (at 10 mA)
Min. switching current
1 mA (at 24 V)
Maximum inrush current
50 mA
Limiting continuous current
50 mA
Interrupting rating (ohmic load) max.
1.2 W (at 24 V DC)
Note
the following values are applicable if a gold layer is destroyed
Maximum switching voltage
250 V AC/DC
Minimum switching voltage
5 V (at 100 mA)
Min. switching current
10 mA (at 12 V)
Limiting continuous current
6A
Interrupting rating (ohmic load) max.
140 W (at 24 V DC)
20 W (at 48 V DC)
18 W (at 60 V DC)
23 W (at 110 V DC)
40 W (at 220 V DC)
05/18/2015 Page 2 / 5
https://www.phoenixcontact.com/us/products/2906061
Hybrid motor starter - ELR H3-IES-PT-24DC/500AC-06-T - 2906061
Technical data
Output data reply output
1500 VA (for 250 V AC)
Switching capacity according to IEC 60947-5-1
2 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.1 A (at 220 V, DC13)
3 A (at 24 V, AC15)
3 A (at 120 V, AC15)
3 A (at 230 V, AC15)
Measuring technology and signaling contact
Measuring via
Current transformer for line current on L1 and L3
Connection data
Connection method
Push-in connection
Stripping length
10 mm
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
14
General
Mounting position
Vertical (horizontal DIN rail)
Assembly instructions
Can be aligned with spacing = 20 mm
Operating mode
100% operating factor
Designation
Standards/regulations
Standards/regulations
IEC 60947-1
EN 60947-4-2
IEC 61508
ISO 13849
Designation
Air clearances and creepage distances between the power circuits
Standards/regulations
DIN EN 50178
Rated surge voltage
6 kV
Insulation
Safe isolation (EN 50178) for mains voltage ≤ 500 V AC
Safe isolation (IEC 60947-1) for mains voltage ≤ 300 V AC
Basic insulation (IEC 60947-1) for mains voltage of 300 ... 500 V AC
Rated insulation voltage
500 V
Pollution degree
2
Surge voltage category
III
05/18/2015 Page 3 / 5
https://www.phoenixcontact.com/us/products/2906061
Hybrid motor starter - ELR H3-IES-PT-24DC/500AC-06-T - 2906061
Technical data
General
Safety Integrity Level according to IEC 61508
SIL 3 (safe shutdown)
SIL 2 (motor protection)
Category acc. to EN ISO 13849
3
Performance level according to ISO 13849
e
Dimensions
Width
22.5 mm
Height
99 mm
Depth
114.5 mm
Ambient conditions
Ambient temperature (operation)
5 °C ... 70 °C
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Degree of protection
IP20
UL data
Short-circuit current rating (SCCR)
100 kA (500 V AC (30 A CC/30 A J (high fault) fuse))
5 kA (500 V AC (20 A RK5 (standard fault) fuse))
Classifications
eCl@ss
eCl@ss 5.1
27371601
eCl@ss 6.0
27371601
ETIM
ETIM 5.0
EC001037
Approvals
Approvals
Approvals
UL Listed / cUL Listed / cULus Listed
Ex Approvals
ATEX
05/18/2015 Page 4 / 5
https://www.phoenixcontact.com/us/products/2906061
Hybrid motor starter - ELR H3-IES-PT-24DC/500AC-06-T - 2906061
Approvals
Approvals submitted
Approval details
UL Listed
cUL Listed
cULus Listed
Drawings
Output current [A]
Diagram
0,9
0,8
0,7
0,6
0,5
0,4
0,3
0,2
0,1
= aligned with 20 mm spacing
= aligned without spacing
5 10
20
30
40
50
60
70
Ambient temperature [°C]
Derating curve
Phoenix Contact 2015 © - all rights reserved
http://www.phoenixcontact.com
05/18/2015 Page 5 / 5