Modular Electronic Housing
ME.../TBUS
co
s.
nt
on
l
in
ec
om
po
ne
The ME...TBUS modular electronic housings have
been designed especially for bus applications in which
it is frequently necessary to disconnect entire individual
modules from the whole.
Mounting rail bus connectors ME 17,5 or ME 22,5
TBUS 1,5/5-ST-3,81 are positioned in the DIN rail and
snapped together to contact the communication and
power signals in parallel with one another. The
ME...TBUS modular electronic housings with widths of
17.5, 22.5, 35 and 45 mm can be combined with these
bus connectors. The housing is mounted on the rail by
swinging it in in the familiar manner and is mechanically
guided by the DIN rail connector.
This concept allows entire individual devices to be
removed from the whole without interrupting the signal
chain.
The DIN rail bus connector is designed as 5-pos.
with a 3.81 mm pitch. Gold-plated contacts guarantee
high reliability of transmission. An extensive MINI
COMBICON range and matching cable housings are
available for supplying the signals.
Owing to the position of the plug deep inside the DIN
rail, more assembly space is available on the printed
circuit board with the same external dimensions for the
ME housing.
Versions with integrated function earth contact can
be supplied to improve electromagnetic compatibility.
To guarantee optimum heat regulation, there are
both open and closed housing versions. Flexible wiring
options with p.c. terminal blocks or plug connection
systems, with either spring cage or screw connection
systems round off the range.
m
1. Description
Phoenix Contact GmbH & Co. KG • 32823 Blomberg, Germany
Phone +49 52 35 3-00 • Fax +49 52 35 3-4 12 00 • www.phoenixcontact.com
Modular electronic housing – ME.../TBUS
2. Technical Data
Dimensional drawing ME…TBUS…
99
7
114,5
B
Figure 03
Housing width [B]: 17.5 or 35 mm
Figure 04
m
ME…/TBUS
(IEC)
[mm2]
rigid
solid
flexible
stranded
AWG
U
[V]
co
17.5 or 35 mm wide, 12 or 24-pos.
I
[A]
nt
s.
MSTBT 2,5/...
0.2-2.5
0.2-2.5 24-12
250
12
MSTBT 2,5 HC/… 0.2-2.5
0.2-2.5 24-12
250
16
MKDSO 2,5/...
0.14-2.5
0.14-2.5 26-14
320
24
ME…TBUS 1,5…
–
–
–
125
8
The connection cross section refers to untreated conductors
without ferrules.
Order No.
Pcs.
Pkt.
ME 17,5 UT TBUS GN
ME 17,5 UTG TBUS GN
27 09 51 6
27 09 52 9
10
10
ME 35 UT TBUS GN
ME 35 UTG TBUS GN
27 09 53 2
27 09 54 5
10
10
ME 17,5 TBUS 1,5/5-ST-3,81
27 09 56 1
10
ME 17,5 OT-MSTBO SET
29 07 43 1
1
Housing upper part set, double-level,
complete with printed circuit termination blocks
for full equipment
ME 17,5 OT-MKDSO SET
29 07 46 0
1
Housing upper part set, double-level,
complete with COMBICON headers
and screw plugs for full equipment
ME 35 OT-MSTBO SET
27 07 73 8
1
ne
Type
open
closed
Housing base,
35 mm wide,
completely preassembled, w/o bus connector
open
closed
Bus connector1), gold-plated contacts,
for DIN rail mounting
5-pos.
1
on
l
in
ec
Housing upper part set, double-level,
complete with COMBICON headers
and screw plugs for full equipment
om
Housing base,
17.5 mm wide
completely preassembled, w/o bus connector
po
Description
) An extensive range of printed ciruit board connection systems is
available for supplying the signals. Please refer to the COMBICON
catalog or visit us on the Internet under
www.select.phoenixcontact.com.
Phoenix Contact page 2 of 5
Modular electronic housing – ME.../TBUS
2. Technical Data
Dimensional drawing ME…TBUS…
102
128,3
B
7
114,5
99
Housing width [B]: 22.5 or 45 mm
Figure 05
Figure 06
m
ME…/TBUS
(IEC)
[mm2]
rigid
solid
flexible
stranded
AWG
U
[V]
co
22.5 or 45 mm wide, 4/8/16/24/32-pos.
I
[A]
ne
nt
s.
MSTBT 2,5/...
0.2-2.5
0.2-2.5 24-12
250
12
MSTBT 2,5 HC/… 0.2-2.5
0.2-2.5 24-12
250
16
MKDSO 2,5/...
0.14-2.5
0.14-2.5 26-14
320
24
ME…TBUS 1,5/…
–
–
–
125
8
The connection cross section refers to untreated conductors
without ferrules.
Order No.
Pcs.
Pkt.
ME 22,5 UT TBUS GN
ME 22,5 UTG TBUS GN
27 07 38 5
27 07 40 8
10
10
ME 45 UT TBUS GN
ME 45 UTG TBUS GN
27 13 01 0
27 13 02 3
10
10
ME 22,5 TBUS 1,5/5-ST-3,81
27 07 43 7
10
1 x 4 positions
ME 22,5 OT-1MSTBO SET
27 07 74 1
1
Housing upper part set, as above,
however, double-level
4 x 4 positions
ME 22,5 OT-MSTBO SET
29 07 44 4
1
Housing upper part set, as above,
however, three-level
6 x 4 positions
ME 22,5 OT-3MSTBO SET
27 07 76 7
1
4 x 4 positions
ME 22,5 OT-MKDSO SET
29 07 47 3
1
8 x 4 positions
ME 45 OT-MKDSO SET
29 09 34 5
1
8 x 4 positions
ME 45 OT-MSTBO SET
29 09 90 5
1
2 x 4 positions
ME 45 OT-1MSTBO SET
27 07 75 4
1
Type
open
closed
Housing base,
45 mm wide,
completely preassembled, w/o bus connector
open
closed
Bus connector1), gold-plated contacts,
for DIN rail mounting
5-pos.
om
Housing base,
22,5 mm wide
completely preassembled, w/o bus connector
po
Description
on
l
in
ec
Housing upper part set, single-level, complete
with COMBICON headers and screw plugs for
full equipment, width: 22.5 mm
Housing upper part set, double-level,
complete with printed circuit termination blocks
for full equipment, width: 22.5 mm
Housing upper part set, as above,
however, width: 45 mm
Housing upper part set, double-level,
complete with COMBICON headers and screw
plugs for full equipment, width: 45 mm
Housing upper part set, as above,
however, single-level
1
) An extensive range of printed ciruit board connection systems is
available for supplying the signals. Please refer to the COMBICON
catalog or visit us on the Internet under
www.select.phoenixcontact.com.
Phoenix Contact page 3 of 5
Modular electronic housing – ME.../TBUS
General Data
Type of housing/insulation material
Inflammability class
Color
Polyamide PA 6.6
V0 (UL94)
Green
Power loss as a function of the
ambient temperature with vents ME… UT…
ME 17,5 ME 35
mounted in rows without/with spacing (≥ 20 mm)
power loss PV [W] at 20°C
Power loss as a function of the
ambient temperature without vents ME… UTG…
ME 22,5
ME 45
5.2
7.9
6.1
8.2
10.8
16.3
12.1
16.5
Equation for the calculation of power loss
dependent upon the ambient temperature
Pvtu = Pvt x KI
ME 45
7.5
5.7
7.6
8.9
13.8
10.1
14.1
= power loss
= ambient temperature
= 20 °C
= reduction factor
s.
Explanations: Pv
tu
t
KI
co
mounted in rows without/with spacing (≥ 20 mm)
power loss PV [W] at 20°C
ME 22,5
4.9
m
ME 17,5 ME 35
nt
Example:Power loss at 40 °C in ME 35
with vents, mounted in rows with spacing.
Pv40 °C = Pv20 °C x KI = 16.3 W x 0.81 = 13.20 W
As the maximum permissible power loss decreases with an increase in
the ambient temperature, the listed reduction factor (K1) must be taken
into account when calculating the permissible power loss.
ne
Reduction factor dependent
upon the ambient temperature
om
po
Ambient temperature [°C]
in
ec
Notes on power loss
30
40
50
60
1
0.91
0.81
0.7
0.57
The given power loss variables are dependent to a large extent
on
• the arrangement of the printed circuit boards in the housing
• the position ot the components (as a source of warmth)
• the number of equipped printed circuit terminal blocks in the housing.
• the housing installation position:
horizontal
on
l
Notes
KI
20
vertical
COMBICON plug connectors may only be actuated in the no-load
condition. If smaller loads need to be switched for operational
reasons, experimental values are available on request. (See also
COMBICON and P.C. Terminal Blocks).
At least one COMBICON pin strip or one p.c. terminal block per side
must be mounted on the p.c.b.
Ordering example:
ME 35 for mounting rail bus and p.c. terminal block connection
systems
1 x Housing base
ME 35 UT TBUS GN
Order No.: 27 09 53 2
2 x Housing upper part for
p.c. terminal block connection
ME 17,5 OT-MKDSO SET
Order No.: 29 07 46 0
2 x Bus connector for DIN rail
mounting
ME 17,5 TBUS 1,5/5-ST-3,81
Phoenix Contact page 4 of 5
Order No.: 27 09 56 1
Modular electronic housing – ME.../TBUS
3. Notes on Connecting
Dimensional drawing of the p.c.b. ME…/TBUS
for single-level upper part
Pin assignment right and left
84,7
37
27,3
Component side
3
2
3
5
6
5
6
3
2
3 1
2 3 1
7
5 6
7
5 6
2
3 1 4
2 3
8
7 5
8
7
R
1,
2
R
1,
2
5
15
R
1,
3
R
1,
2
2
1,3
1,1x45°
2
36,3
33,25
34,9
20,75
18,35
24,9
1,4
L1
3,5
1 4
6
5 6
20,27
18,24
8,9
8
4
12,25
20
Figure 07
Fase 0,5x45°
Dimensional drawing of the p.c.b. ME…/TBUS
for double-level upper part
s.
Inside view of the ME.../TBUS housing
80
73
nt
54,6
36,2
7
8
Component
side
5
6
3
7
4
8
47
77,6
20,27
18,24
3,81
1
1,5
10,8
15,8
16,1
2,2
15,9
1,5
21,1
1,5
1,5
4
2
8,9
in
ec
8
4,6
1,5
30°
7
9,6
1,2
2,5
1
2,84
2
12,62
2,2
10,9
1,5
om
49,8
4,1
2,2
2,2
45
L
31,4
35
20
12,25
Figure 09
Fase 0,5x45°
on
l
Dimensional drawing of the p.c.b. ME…/TBUS
for three-level upper part
Figure 10
http://www.phoenixcontact.com
2
1,
R
2
po
5
1
ne
2,2
20,7
6
5
2
4
22,5
17,5
5
3
33,2
80
41,6
32,2
6
3
7
4
8
2,4
5
2
6
3
7
8
4
1
Component side
2
3
2,4
5
2,6
6
7
4
8
77,6
L
5
2,2
12,4
5
2
5,1
28,8
18,6
1
2
1,
R
45,2
35
27,4
1
20,27
18,24
1
8,9
8
4
4,6
Fase 0,5x45°
12,62
2,84
12,25
1
2
4,1
30°
7
9,6
1,2
2,5
2
3,81
20
Figure 11
Phoenix Contact page 5 of 5
01.11.02
TNR: 5126633-01
55,8
Phoenix Contact
36,25
14,7
1,4
28,6
1
Figure 08
co
4,6
12,62
right
1
2,84
2
4,1
left
30°
7
9,6
1,2
2,5
m
1
2
3,81