0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2907918

2907918

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    SURGE PROTECTION

  • 数据手册
  • 价格&库存
2907918 数据手册
https://www.phoenixcontact.com/pi/products/2907918 Type 3 surge protection device - PLT-SEC-T3-120-FM-UT - 2907918 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Type 2/3 surge protection, consisting of protective plug and base element, with integrated status indicator and remote signaling for single-phase power supply networks. Nominal voltage 120 V AC/DC. Your advantages  Increased service life and availability of the system, thanks to optimal protection of your industrial power supply  5-year warranty on your QUINT 4 power supply when installed together with PLT-SEC, see document in the download area  Easy maintenance and testing of protective devices, thanks to pluggable connections Key Commercial Data Packing unit 5 pc GTIN GTIN 4055626257440 Technical data Dimensions Height 93.4 mm Width 17.7 mm Depth 74.5 mm (incl. DIN rail 7.5 mm) Horizontal pitch 1 Div. Ambient conditions Degree of protection IP20 Ambient temperature (operation) -40 °C ... 80 °C Ambient temperature (storage/transport) -40 °C ... 80 °C Altitude ≤ 2000 m (operating voltage remote contact ≤ 250 V) ≤ 6000 m (operating voltage remote contact ≤ 150 V) Permissible humidity (operation) 5 % ... 95 % Shock (operation) 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) 06/11/2019   Page 1 / 6 https://www.phoenixcontact.com/pi/products/2907918 Type 3 surge protection device - PLT-SEC-T3-120-FM-UT - 2907918 Technical data Ambient conditions Vibration (operation) 5g (5 ... 500 Hz / 2.5 h / X, Y, Z) General EN type T2 / T3 IEC power supply system TT TN-S Number of ports One Mode of protection L-N L-PE N-PE Mounting type DIN rail: 35 mm Color light grey RAL 7035 traffic grey A RAL 7042 Housing material PA 6.6-FR 20% GF PA 6.6-FR Degree of pollution 2 Flammability rating according to UL 94 V-0 Type DIN rail module, two-section, divisible Number of positions 2 Surge protection fault message Optical, remote indicator contact Protective circuit Nominal voltage UN 120 V AC (TN-S) 120 V AC (TT) Nominal frequency fN 50 Hz (60 Hz) Maximum continuous voltage UC 150 V AC Rated load current IL 26 A (at 30 °C) Residual current IPE ≤ 5 µA Nominal discharge current In (8/20) µs 5 kA Standby power consumption PC ≤ 10.6 mVA (at UREF) ≤ 13.5 mVA (at UC) Reference test voltage UREF 132 V AC Max. discharge current Imax (8/20) µs 10 kA Combination wave UOC 6 kV Voltage protection level Up (L-N) ≤ 0.75 kV (at UOC) ≤ 0.95 kV (at In) Voltage protection level Up (L-PE) ≤ 0.85 kV Voltage protection level Up (N-PE) ≤ 0.85 kV TOV behavior at UT (L-N) 240 V AC (5 s / withstand mode) 240 V AC (120 min / withstand mode) TOV behavior at UT (L-PE) 240 V AC (5 s / withstand mode) 06/11/2019   Page 2 / 6 https://www.phoenixcontact.com/pi/products/2907918 Type 3 surge protection device - PLT-SEC-T3-120-FM-UT - 2907918 Technical data Protective circuit 240 V AC (120 min / withstand mode) 1332 V AC (200 ms / safe failure mode) TOV behavior at UT (N-PE) 1200 V AC (200 ms / safe failure mode) Response time tA (L-N) ≤ 25 ns Response time tA (L-PE) ≤ 100 ns Response time tA (N-PE) ≤ 100 ns Short-circuit current rating ISCCR 10 kA AC Max. backup fuse with branch wiring 32 A (gG / B / C) Maximum backup fuse for through wiring 25 A (gG / B / C) Additional technical data Short-circuit current rating ISCCR 0.25 kA DC (without additional backup fuse) 5 kA DC (for 20 A gG / B backup fuse) Maximum continuous voltage UC 150 V DC Mode of protection (DC+) - (DC-) (DC+/DC-) - PE IEC test classification (in accordance with IEC 61643-21) D1 Impulse durability (line-line) D1 - 500 A Impulse durability (line-earth) D1 - 500 A Pulse discharge current Iimp (10/350) µs (line-line) 0.5 kA Pulse discharge current Iimp (10/350) µs (line-earth) 0.5 kA Indicator/remote signaling Switching function PDT contact Operating voltage 250 V AC 125 V DC (200 mA DC) Operating current 0.5 A AC 0.5 A DC (75 V DC) Connection method Screw connection Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section AWG 30 ... 12 Screw thread M3 Tightening torque 0.5 Nm Stripping length 10 mm Connection data Connection method Screw connection Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section solid 0.2 mm² ... 4 mm² Conductor cross section AWG 24 ... 12 Screw thread M3 06/11/2019   Page 3 / 6 https://www.phoenixcontact.com/pi/products/2907918 Type 3 surge protection device - PLT-SEC-T3-120-FM-UT - 2907918 Technical data Connection data Tightening torque 0.5 Nm Stripping length 10 mm UL specifications SPD Type 2 (Open-Type SPD) Maximum continuous operating voltage MCOV 150 V AC 150 V DC Nominal voltage 150 V DC Rated load current IL 20 A Mode of protection L-N L-G N-G (DC+) - (DC-) (DC+) - G (DC-) - G Power distribution system Single phase DC Nominal frequency 50/60 Hz Voltage protection rating VPR (L-N) 700 V Voltage protection rating VPR (L-G) 900 V Voltage protection rating VPR (N-G) 900 V Nominal discharge current In 5 kA Short-circuit current rating (SCCR) 10 kA AC 5 kA DC UL indicator/remote signaling Operating voltage 250 V AC (0.5 A) 12 V DC (4 A) 24 V DC (2 A) 48 V DC (1 A) Tightening torque 5 lbf-in. ... 7 lbf-in. Conductor cross section AWG 30 ... 12 UL connection data Conductor cross section AWG 16 ... 12 Tightening torque 4.4 lbf-in. Standards and Regulations Standards/specifications IEC 61643-11 2011 EN 61643-11 2012 Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 06/11/2019   Page 4 / 6 https://www.phoenixcontact.com/pi/products/2907918 Type 3 surge protection device - PLT-SEC-T3-120-FM-UT - 2907918 Technical data Environmental Product Compliance For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings Diagram Dimensional drawing 93,4 I [A] 30 90 17,7 20 30 40 50 60 70 80 T [°C] 90 67 20 74,5 10 Nominal current depending on ambient temperature Circuit diagram 6 L L 5 12 14 FM 11 N 1 2 N PE PE Approvals Approvals Approvals DNV GL / CCA / UL Listed / KEMA-KEUR / IECEE CB Scheme / cUL Listed / EAC / CSA / cULus Listed Ex Approvals UL Recognized / cUL Recognized / cULus Recognized Approval details DNV GL  CCA    http://exchange.dnv.com/tari/  TAE00002U7    NTR-NL 7676 06/11/2019   Page 5 / 6 https://www.phoenixcontact.com/pi/products/2907918 Type 3 surge protection device - PLT-SEC-T3-120-FM-UT - 2907918 Approvals UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 330181 KEMA-KEUR    http://www.dekra-certification.com  71-103027 IECEE CB Scheme    http://www.iecee.org/  NL-51083 cUL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 330181 EAC      RU CDE.A*30.B01561 CSA    http://www.csagroup.org/services-industries/product-listing/  70194378 cULus Listed       Phoenix Contact 2019 © - all rights reserved http://www.phoenixcontact.com PHOENIX CONTACT GmbH & Co. KG Flachsmarktstr. 8 32825 Blomberg Germany Tel. +49 5235 300 Fax +49 5235 3 41200 http://www.phoenixcontact.com 06/11/2019   Page 6 / 6
2907918 价格&库存

很抱歉,暂时无法提供与“2907918”相匹配的价格&库存,您可以联系我们找货

免费人工找货