https://www.phoenixcontact.com/pi/products/2907919
Type 3 surge protection device - PLT-SEC-T3-230-FM-UT - 2907919
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Type 2/3 surge protection, consisting of protective plug and base element with screw connection. For singlephase power supply network with integrated status indicator and remote signaling. Nominal voltage 230 V AC/
DC.
Your advantages
Increased service life and availability of the system, thanks to optimal protection of your industrial power supply
5-year warranty on your QUINT 4 power supply when installed together with PLT-SEC, see document in the download area
Easy maintenance and testing of protective devices, thanks to pluggable connections
Key Commercial Data
Packing unit
5 pc
GTIN
GTIN
4055626257457
Technical data
Dimensions
Height
93.4 mm
Width
17.7 mm
Depth
74.5 mm (incl. DIN rail 7.5 mm)
Horizontal pitch
1 Div.
Ambient conditions
Degree of protection
IP20
Ambient temperature (operation)
-40 °C ... 80 °C
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Altitude
≤ 2000 m (operating voltage remote contact ≤ 250 V)
≤ 6000 m (operating voltage remote contact ≤ 150 V)
Permissible humidity (operation)
5 % ... 95 %
Shock (operation)
30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
06/11/2019 Page 1 / 6
https://www.phoenixcontact.com/pi/products/2907919
Type 3 surge protection device - PLT-SEC-T3-230-FM-UT - 2907919
Technical data
Ambient conditions
Vibration (operation)
5g (5 ... 500 Hz / 2.5 h / X, Y, Z)
General
EN type
T2 / T3
IEC power supply system
TT
TN-S
Number of ports
One
Mode of protection
L-N
L-PE
N-PE
Mounting type
DIN rail: 35 mm
Color
light grey RAL 7035
traffic grey A RAL 7042
Housing material
PA 6.6-FR 20% GF
PA 6.6-FR
Degree of pollution
2
Flammability rating according to UL 94
V-0
Type
DIN rail module, two-section, divisible
Number of positions
2
Surge protection fault message
Optical, remote indicator contact
Protective circuit
Nominal voltage UN
240 V AC (TN-S)
240 V AC (TT)
Nominal frequency fN
50 Hz (60 Hz)
Maximum continuous voltage UC
264 V AC
Rated load current IL
26 A (at 30 °C)
Residual current IPE
≤ 5 µA
Nominal discharge current In (8/20) µs
5 kA
Standby power consumption PC
≤ 26.4 mVA (at UREF)
≤ 26.4 mVA (at UC)
Reference test voltage UREF
264 V AC
Max. discharge current Imax (8/20) µs
10 kA
Combination wave UOC
6 kV
Voltage protection level Up (L-N)
≤ 1.25 kV (at UOC)
≤ 1.4 kV (at In)
Voltage protection level Up (L-PE)
≤ 1.4 kV
Voltage protection level Up (N-PE)
≤ 1.4 kV
TOV behavior at UT (L-N)
400 V AC (5 s / withstand mode)
457 V AC (120 min / safe failure mode)
TOV behavior at UT (L-PE)
457 V AC (5 s / withstand mode)
06/11/2019 Page 2 / 6
https://www.phoenixcontact.com/pi/products/2907919
Type 3 surge protection device - PLT-SEC-T3-230-FM-UT - 2907919
Technical data
Protective circuit
457 V AC (120 min / withstand mode)
1464 V AC (200 ms / safe failure mode)
TOV behavior at UT (N-PE)
1200 V AC (200 ms / safe failure mode)
Response time tA (L-N)
≤ 25 ns
Response time tA (L-PE)
≤ 100 ns
Response time tA (N-PE)
≤ 100 ns
Short-circuit current rating ISCCR
10 kA AC
Max. backup fuse with branch wiring
32 A (gG / B / C)
Maximum backup fuse for through wiring
25 A (gG / B / C)
Additional technical data
Short-circuit current rating ISCCR
0.25 kA DC (without additional backup fuse)
5 kA DC (for 20 A gG / B backup fuse)
Maximum continuous voltage UC
275 V AC
240 V DC
Mode of protection
(DC+) - (DC-)
(DC+/DC-) - PE
IEC test classification (in accordance with IEC 61643-21)
D1
Impulse durability (line-line)
D1 - 500 A
Impulse durability (line-earth)
D1 - 500 A
Pulse discharge current Iimp (10/350) µs (line-line)
0.5 kA
Pulse discharge current Iimp (10/350) µs (line-earth)
0.5 kA
Indicator/remote signaling
Switching function
PDT contact
Operating voltage
250 V AC
125 V DC (200 mA DC)
Operating current
0.5 A AC
0.5 A DC (75 V DC)
Connection method
Screw connection
Conductor cross section flexible
0.2 mm² ... 2.5 mm²
Conductor cross section solid
0.2 mm² ... 2.5 mm²
Conductor cross section AWG
30 ... 12
Screw thread
M3
Tightening torque
0.5 Nm
Stripping length
10 mm
Connection data
Connection method
Screw connection
Conductor cross section flexible
0.2 mm² ... 2.5 mm²
Conductor cross section solid
0.2 mm² ... 4 mm²
Conductor cross section AWG
24 ... 12
06/11/2019 Page 3 / 6
https://www.phoenixcontact.com/pi/products/2907919
Type 3 surge protection device - PLT-SEC-T3-230-FM-UT - 2907919
Technical data
Connection data
Screw thread
M3
Tightening torque
0.5 Nm
Stripping length
10 mm
UL specifications
SPD Type
4CA
Maximum continuous operating voltage MCOV
264 V AC
240 V DC
Nominal voltage
240 V DC
Rated load current IL
20 A
Mode of protection
L-N
L-G
N-G
(DC+) - (DC-)
(DC+) - G
(DC-) - G
Power distribution system
Single phase
DC
Nominal frequency
50/60 Hz
Measured limiting voltage MLV (L-N)
1150 V
Measured limiting voltage MLV (L-G)
1180 V
Measured limiting voltage MLV (N-G)
1180 V
Nominal discharge current In
5 kA
UL indicator/remote signaling
Operating voltage
250 V AC (0.5 A)
12 V DC (4 A)
24 V DC (2 A)
48 V DC (1 A)
Tightening torque
5 lbf-in. ... 7 lbf-in.
Conductor cross section AWG
30 ... 12
UL connection data
Conductor cross section AWG
16 ... 12
Tightening torque
4.4 lbf-in.
Standards and Regulations
Standards/specifications
IEC 61643-11 2011
EN 61643-11 2012
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50
06/11/2019 Page 4 / 6
https://www.phoenixcontact.com/pi/products/2907919
Type 3 surge protection device - PLT-SEC-T3-230-FM-UT - 2907919
Technical data
Environmental Product Compliance
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings
Diagram
Dimensional drawing
93,4
I [A]
30
90
17,7
20
30
40
50
60
70
80
T [°C]
90
67
20
74,5
10
Nominal current depending on ambient temperature
Circuit diagram
6 L
L 5
12
14 FM
11
N 1
2 N
PE
PE
Approvals
Approvals
Approvals
DNV GL / CCA / UL Recognized / KEMA-KEUR / cUL Recognized / IECEE CB Scheme / EAC / CSA / cULus Recognized
Ex Approvals
UL Recognized / cUL Recognized / cULus Recognized
Approval details
DNV GL
CCA
http://exchange.dnv.com/tari/
TAE00002U7
NTR-NL 7676
06/11/2019 Page 5 / 6
https://www.phoenixcontact.com/pi/products/2907919
Type 3 surge protection device - PLT-SEC-T3-230-FM-UT - 2907919
Approvals
UL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 330181
KEMA-KEUR
http://www.dekra-certification.com
71-103027
cUL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 330181
IECEE CB Scheme
http://www.iecee.org/
NL-51083
EAC
RU CDE.A*30.B01561
CSA
http://www.csagroup.org/services-industries/product-listing/
70194378
cULus Recognized
Phoenix Contact 2019 © - all rights reserved
http://www.phoenixcontact.com
PHOENIX CONTACT GmbH & Co. KG
Flachsmarktstr. 8
32825 Blomberg
Germany
Tel. +49 5235 300
Fax +49 5235 3 41200
http://www.phoenixcontact.com