0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2908065

2908065

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    2-CHANNEL OUTPUT SIGNAL CONDITIO

  • 数据手册
  • 价格&库存
2908065 数据手册
MACX MCR-IDS-2I-2I(-SP) Output signal conditioner, 2-channel Data sheet 109173_en_02 1 © PHOENIX CONTACT 2021-05-27 Description The 2-channel output signal conditioner is used for electrically isolated actuation of I/P transducers, regulating valves, and displays. The device isolates and transmits 0.2/4 mA ... 20 mA signals. For the purpose of operating HART actuators, the analog measured value can be overlaid with digital communication signals (HART) and transmitted bidirectionally in an electrically isolated manner. Sockets are integrated into the COMBICON connectors for connecting HART (HHT) communicators. Features – – – – – – – – The device enables open-circuit and short-circuit monitoring. – An open or short-circuited field circuit causes a high input impedance on the controller side, thus enabling open-circuit and short-circuit monitoring via the control system. – – – Readiness for operation is indicated via a green LED. The device is approved for safety-related applications up to SIL 2 (1oo1) / SIL 3 (1oo2). – – 2-channel Input 0.2/4 mA ... 20 mA Output 0.2/4 mA ... 20 mA Output load up to 700 Ω Bidirectional HART signal transmission Short circuit monitoring Line break monitoring Up to SIL 2 (1oo1) / SIL 3 (1oo2) in accordance with IEC/EN 61508 Safe electrical isolation between input, output, and supply Power supply possible via DIN rail connector Installation in Ex zone 2 permitted Plug-in connection terminal blocks, either screw or spring-cage connection technology (Push-in technology) Housing width of 12.5 mm High transmission accuracy WARNING: Explosion hazard The EPL Gc (ATEX category 3) device is designed for installation in zone 2 potentially explosive areas. It satisfies the requirements of the following standards. Comprehensive details are to be found in the EU Declaration of Conformity, which is enclosed and also available on our website in the latest version: IEC/EN 60079-0, IEC/EN 60079-7 When installing and operating the device, the applicable safety directives (including national safety directives), accident prevention regulations, as well as general technical regulations must be observed. Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products. This document is valid for the products listed in the “Ordering data”. MACX MCR-IDS-2I-2I(-SP) 2 Table of contents 1 Description .............................................................................................................................. 1 2 Table of contents ..................................................................................................................... 2 3 Ordering data .......................................................................................................................... 3 4 Technical data ......................................................................................................................... 5 5 Safety regulations and installation notes.................................................................................. 9 5.1 Installation notes ................................................................................................................. 9 5.2 Installation in Zone 2............................................................................................................. 9 5.3 Potentially dust-explosive areas .............................................................................................. 9 5.4 UL note ............................................................................................................................. 9 5.5 Safety-related applications (SIL) .............................................................................................. 9 6 Installation ............................................................................................................................. 10 6.1 Connection notes .............................................................................................................. 10 6.2 Electrostatic discharge ........................................................................................................ 10 6.3 Structure ......................................................................................................................... 10 6.4 Basic circuit diagram with connection terminal blocks ................................................................. 11 6.5 Input ............................................................................................................................... 11 6.6 Output ............................................................................................................................ 11 6.7 Power supply .................................................................................................................... 11 6.8 Dimensions ...................................................................................................................... 12 6.9 Mounting ......................................................................................................................... 12 6.10 Connecting the cables ........................................................................................................ 13 6.11 Startup ............................................................................................................................ 13 7 Safety-related applications .................................................................................................... 14 7.1 Safety function .................................................................................................................. 14 7.2 Safety integrity requirements ................................................................................................ 15 7.3 Conditions ....................................................................................................................... 18 7.4 Installation and startup ........................................................................................................ 18 7.5 Notes on operation ............................................................................................................. 19 7.6 Recurring checks ............................................................................................................... 19 7.7 Repair ............................................................................................................................. 19 7.8 Standards ........................................................................................................................ 20 7.9 Abbreviations ................................................................................................................... 20 109173_en_02 PHOENIX CONTACT 2/20 MACX MCR-IDS-2I-2I(-SP) 3 Ordering data Description Type Order No. Pcs./Pkt. 2-channel output signal conditioner, HART. Isolates and transmits 0/4 ... 20 mA signals to a load in the safe zone. Galvanic 4-way electrical isolation, line fault detection, SIL 2 (SC3) in accordance with IEC 61508, screw connection. MACX MCR-IDS-2I-2I 2908065 1 2-channel output signal conditioner, HART. Isolates and transmits 0/4 ... 20 mA signals to a load in the safe zone. Galvanic 4-way electrical isolation, line fault detection, SIL 2 (SC3) in accordance with IEC 61508, Push-in connection. MACX MCR-IDS-2I-2I-SP 2908066 1 Accessories Type Order No. Pcs./Pkt. DIN rail connector (TBUS), 5-pos., for bridging the supply ME 6,2 TBUS-2 1,5/5-ST-3,81 2695439 voltage, can be snapped onto NS 35/... DIN rails GY according to EN 60715 10 Power and fault signaling module with screw connection, MACX MCR-PTB including corresponding ME 17,5 TBUS 1,5/ 5-ST-3,81 GY DIN rail connector 2865625 1 Power and fault signaling module with Push-in connection, including corresponding ME 17,5 TBUS 1,5/ 5-ST-3,81 GY DIN rail connector MACX MCR-PTB-SP 2924184 1 Universal termination carrier for connecting 16 MACX Analog Ex i signal conditioners to digital or analog I/O cards, via D-SUB connector, 37-pos. (1:1 connection), with HART multiplexer connection TC-D37SUB-AIO16-EX-PSUNI 2902932 1 Universal termination carrier for connecting 16 MACX Analog Ex i signal conditioners to digital or analog I/O cards, via D-SUB connector, 37-pos. (1:1 connection) TC-D37SUB-ADIO16-EX-PUNI 2924854 1 Insulating sleeve, color: white MPS-IH WH 0201663 10 Insulating sleeve, color: red MPS-IH RD 0201676 10 Insulating sleeve, color: blue MPS-IH BU 0201689 10 Insulating sleeve, color: yellow MPS-IH YE 0201692 10 Insulating sleeve, color: green MPS-IH GN 0201702 10 Insulating sleeve, color: gray MPS-IH GY 0201728 10 Insulating sleeve, color: black MPS-IH BK 0201731 10 Test plugs, with solder connection up to 1 mm² conductor MPS-MT cross section, color: gray 0201744 10 Plastic label, Sheet, white, unlabeled, can be labeled with: UC-EMLP (11X9) BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 10 0819291 10 109173_en_02 PHOENIX CONTACT 3/20 MACX MCR-IDS-2I-2I(-SP) Accessories Type Order No. Pcs./Pkt. Plastic label, Sheet, yellow, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 10 UC-EMLP (11X9) YE 0822602 10 Plastic label, can be ordered: by sheet, white, labeled according to customer specifications, mounting type: adhesive, lettering field size: 11 x 9 mm UC-EMLP (11X9) CUS 0824547 1 Plastic label, can be ordered: by sheet, yellow, labeled according to customer specifications, mounting type: adhesive, lettering field size: 11 x 9 mm UC-EMLP (11X9) YE CUS 0824548 1 Plastic label, Sheet, silver, unlabeled, can be labeled with: UC-EMLP (11X9) SR BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 10 0828094 10 Plastic label, can be ordered: by sheet, silver, labeled according to customer specifications, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 10 0828098 1 Plastic label, Card, white, unlabeled, can be labeled with: US-EMLP (11X9) BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 135 0828789 10 Plastic label, Card, yellow, unlabeled, can be labeled with: US-EMLP (11X9) YE BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 135 0828871 10 Plastic label, Card, silver, unlabeled, can be labeled with: US-EMLP (11X9) SR BLUEMARK ID COLOR, BLUEMARK ID, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 135 0828872 10 Device marker, Sheet, white, unlabeled, can be labeled LS-EMLP (11X9) WH with: TOPMARK NEO, TOPMARK LASER, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 255 0831678 10 Device marker, Sheet, silver, unlabeled, can be labeled LS-EMLP (11X9) SR with: TOPMARK NEO, TOPMARK LASER, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 255 0831705 10 Device marker, Sheet, yellow, unlabeled, can be labeled LS-EMLP (11X9) YE with: TOPMARK NEO, TOPMARK LASER, mounting type: adhesive, lettering field size: 11 x 9 mm, Number of individual labels: 255 0831732 10 109173_en_02 UC-EMLP (11X9) SR CUS PHOENIX CONTACT 4/20 MACX MCR-IDS-2I-2I(-SP) 4 Technical data Input data Current input signal 0.2 mA ... 20 mA (Function) 4 mA ... 20 mA (Safety) 0 mA ... 24 mA (Underload/overload range) Input current ≤ 30 mA Input impedance in the event of a line fault at the output > 1 MΩ (If there is a line fault) Line fault detection Response threshold of input current >0.2 mA Voltage drop < 2.4 V (at 20 mA) Output Output description Current output Current output signal 0.2 mA ... 20 mA (Function) 4 mA ... 20 mA (Safety) 0 mA ... 24 mA (Underload/overload range) Transmission Behavior 1:1 to input signal Load 100 Ω ... 700 Ω (20 mA) 100 Ω ... 650 Ω (20.5 mA) 100 Ω ... 500 Ω (24 mA) Output ripple < 20 mVrms Non-load voltage ≤ 27 V Wire-break detection Load >10 kΩ Short-circuit detection Load  30 V DC, usable in DC circuits, slow-blow) in the installation. To protect the device against mechanical or electrical damage, install it in suitable housing with an appropriate degree of protection according to IEC/EN  60529. During maintenance work, disconnect the device from all effective power sources. If the device is not used as described in the documentation, the intended protection can be negatively affected. Thanks to its housing, the device has basic insulation to the neighboring devices, for 300 Veff. If several devices are installed next to each other, this has to be taken into account, and additional insulation has to be installed if necessary! If the neighboring device is equipped with basic insulation, no additional insulation is necessary. The voltages applied at the input, output, and power supply are extra-low voltages (ELV). Depending on the application, it can be the case that a voltage that is dangerous to the touch (>30 V AC / >60 V DC) against the ground could be present on the device. In this case, a safe galvanic isolation exists between the input side and the output side. 109173_en_02 6.3 Structure Figure 1 Structure 1 1.1 4 1.2 1.1 2.1 PH FlacOENI 32 hsmX CO 82 ar NT 5 Bl kts AC om tr. 8 T Gm be rg, bH Ge & Co rm .KG an y Iso lati on ww 3.1 w.ph Dri oe nix co ve r ntac t.c 3.2 / A us Iso lati 2.1 on str en tärk er 1.2 1.1 2.2 2.1 3.2 3.1 PW 2.2 3.1 ww w.ph Dri oe nix co ve r ntac t.c 3.2 om / A us ga ng nve rs 1.2 PH FlacOENI 32 hsmX CO 82 ar NT 5 Bl kts AC om tr. 8 T Gm be rg, bH Ge & Co rm .KG an y om ga 3 2.2 ng str en nve rs tärk er R PW 4.2 4.1 5.2 5.1 1 2 3 4 1.2 1.1 2.2 2.1 3.2 3.1 2 R 4.2 4.1 5.2 5.1 COMBICON plug-in, screw, or push-in connection terminal with integrated test socket Green “PWR” LED, power supply Snap-on foot for DIN rail mounting Connection for DIN rail connector PHOENIX CONTACT 10/20 MACX MCR-IDS-2I-2I(-SP) 6.4 Basic circuit diagram with connection terminal blocks Figure 2 Basic circuit diagram Sensor / Field OUT - 4.2 P + 4.1 P 5.2 + - PLC / DCS IN 4.2 AO 3.2 CH1 - 3.2 + 4.1 3.1 5.2 2.2 CH2 + + 5.1 5.1 + 3.1 - 2.2 + 2.1 GND +24V Power - + 1.2 1.1 – – NOTE Never connect the supply voltage directly to the DIN rail connector. It is not permitted to draw power from the DIN rail connector or from individual modules. Supply via the MACX Analog module Where the total current consumption of the aligned modules does not exceed 400 mA, the power can be supplied directly at the connection terminal blocks of the module. Up to 16 modules can be supplied depending on the current consumption of the modules. Zone 2 6.6 The supply voltage can be supplied via terminal points 1.1 and 1.2 or via the DIN rail connector. 2.1 Div. 2 – – Power supply - GND +24V 6.5 6.7 We recommend connecting a 630 mA fuse (normal-blow or slow-blow) upstream. Input Channel 1 on terminal blocks 3.1 (+) and 3.2 (-) Channel 2 on terminal blocks 2.1 (+) and 2.2 (-) Output Channel 1 on terminal blocks 4.1 (+) and 4.2 (-) Channel 2 on terminal blocks 5.1 (+) and 5.2 (-) Supply via power and error message module The MACX MCR-PTB (Order No. 2865625) or the MACX MCR-PTB-SP (Order No. 2924184) supply and error message module is used to provide the supply voltage to the DIN rail connector. Simple or redundant diode-decoupled power supply is possible. Depending on the current consumption of the modules, up to 150 individual modules can be supplied by a supply that is protected by a fuse. The module has integrated error evaluation. An auxiliary supply failure or fuse fault is indicated at a relay contact and displayed via a flashing LED. 109173_en_02 PHOENIX CONTACT 11/20 MACX MCR-IDS-2I-2I(-SP) 6.8 Dimensions Figure 3 6.9 Dimensions Figure 4  116 (SP) 112,5 12,5 Mounting and removing   7 114,5 99 Mounting • • • • 109173_en_02 Mount the device on a 35 mm DIN rail according to EN 60715. When using the DIN rail connector, first insert it in the 35 mm DIN rail according to EN 60715 (A - C). DIN rails with a height of 7.5 mm or more can be used. The DIN rail connector is used to bridge the power supply and communication. The snap-in direction of the device and DIN rail connector must be observed: snap-on foot on the bottom and plug on the left. Install the module in a suitable housing to meet the requirements for the protection class. PHOENIX CONTACT 12/20 MACX MCR-IDS-2I-2I(-SP) 6.10 Connecting the cables Screw Connection Figure 5 Screw connection AWG 24-14 2 0,2-2,5 mm MACX MCR-... A 7 mm B • • • 0,5-0,6 Nm 5-7 lb In Strip the wire by approximately 7 mm and crimp ferrules to the end of the wires. Insert the wire into the corresponding connection terminal block. Use a screwdriver to tighten the screw in the opening above the connection terminal block. Tightening torque: 0.6 Nm Push-in connection: Figure 6 • • • Strip the wire by approximately 8 mm and crimp ferrules to the end of the wires. Insert the wire into the corresponding connection terminal block. Push in the pushbutton with a screwdriver to release. 6.11 • Push-in connection Startup Before startup, check that the device is operating and wired correctly 109173_en_02 PHOENIX CONTACT 13/20 MACX MCR-IDS-2I-2I(-SP) 7 Safety-related applications The following notes apply for the devices: Designation MACX MCR-IDS-2I-2I MACX MCR-IDS-2I-2I-SP MACX MCR-EX-IDS-2I-2I MACX MCR-EX-IDS-2I-2I-SP Order No. 2908065 2908066 2865421 2904931 The safety devices listed above are certified in compliance with DIN EN 61508-1:2011, DIN EN 61508-2:2011, and DIN EN 62061:2016. Certificate: ZP/C002/20 7.1 Safety function The device performs the safety function of galvanic electrically isolated forwarding an input current signal in a proportional (1:1) output signal of 4 mA ... 20 mA with a maximum error of 2%. Operating mode of the safety function In accordance with IEC 61508, the device is suitable for the following operating modes: – Low demand rate – Continuous demand rate – High demand rate You can operate the device in safety-related applications in the following modes: 1. SIL 3, SC 3, 1oo2: In 2-channel coupled mode, both channels will be operated redundantly for one safety application. 2. SIL 2, SC 3, 2x 1oo1: In 2-channel separated mode, each single channel will be operated for a separate safety application. 3. SIL 2, SC 3, 1x 1oo1: In 1-channel mode, one of the two channels will be operated for one safety application. The second channel is available for a non-safety technology application. The process safety time is 
2908065 价格&库存

很抱歉,暂时无法提供与“2908065”相匹配的价格&库存,您可以联系我们找货

免费人工找货