0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2908301

2908301

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    能量监视 LCD - 黑色字符,背光 显示 面板安装

  • 数据手册
  • 价格&库存
2908301 数据手册
EMpro - multi-functional energy measuring devices for front panel installation User manual User manual EMpro - multi-functional energy measuring devices for front panel installation 2020-03-05 UM EN EMpro front panel, Revision 00 This user manual is valid for: Order No. 2907945 2908286 2907944 2908285 2907946 2908301 2907953 2908302 108904_en_00 Designation EEM-MA770 EEM-MA771 EEM-MA770-R EEM-MA771-R EEM-MA770-PN EEM-MA771-PN EEM-MA770-EIP EEM-MA771-EIP PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany phoenixcontact.com Table of contents Table of contents 1 2 For your safety ...........................................................................................................................7 1.1 Identification of warning notes ...............................................................................7 1.2 Qualification of users .............................................................................................7 1.3 Field of application of the product ..........................................................................8 1.3.1 Intended use ..........................................................................................8 1.3.2 Product changes ....................................................................................8 1.4 Safety notes...........................................................................................................8 Device description ...................................................................................................................11 2.1 3 4 5 Product overview .................................................................................................15 Mounting and installation .........................................................................................................17 3.1 Mounting..............................................................................................................17 3.2 Installation ...........................................................................................................18 3.2.1 Pin assignment ....................................................................................19 3.2.2 Supply ..................................................................................................21 3.2.3 Grid types .............................................................................................22 Operating and indication elements ...........................................................................................27 4.1 Technical data of the display ...............................................................................27 4.2 Displaying the events...........................................................................................28 4.3 Operating elements on the display (softkeys) ......................................................29 Basic device configuration .......................................................................................................31 5.1 108904_en_00 Basic device configuration via the display ...........................................................31 5.1.1 Step 1: Language selection ..................................................................31 5.1.2 Step 2: Network settings ......................................................................32 5.1.3 Step 3: IPv4 ..........................................................................................32 5.1.4 Step 4: Grid type ..................................................................................33 5.1.5 Step 5a: Current input (energy measuring device with current transformer) 34 5.1.6 Step 5b: Current input (energy measuring device with Rogowski coil) .35 5.1.7 Step 6: Voltage input ............................................................................35 5.1.8 Step 7: Configuration overview ............................................................36 5.1.9 Step 8: Setting a personal PIN .............................................................36 5.1.10 Step 9: Activating the PIN ....................................................................37 PHOENIX CONTACT 3 / 192 EMpro - multi-functional energy measuring devices for front panel installation 5.2 6 7 8 Basic device configuration via the web server .....................................................37 5.2.1 Step 1: Network settings ......................................................................38 5.2.2 Step 2: Selecting the grid type .............................................................39 5.2.3 Step 3: Configuration of the current input (current transformer) ...........40 5.2.4 Step 3: Configuration of the current input (Rogowski coil) ....................41 5.2.5 Step 4: Voltage input ............................................................................43 5.2.6 Optional: Voltage transducer ................................................................44 5.2.7 Step 5: Configuration overview ............................................................45 Navigation structure and display ..............................................................................................47 6.1 Menu structure on the display..............................................................................47 6.2 Menu structure on the web server........................................................................48 Device settings and information ...............................................................................................51 7.1 Selecting the language ........................................................................................51 7.2 Date and time ......................................................................................................52 7.2.1 Reading the date and time ...................................................................52 7.2.2 Setting the date and time manually ......................................................53 7.2.3 Synchronizing the date and time with an SNTP server .........................54 7.2.4 Time zones ..........................................................................................55 7.2.5 Summer time rule .................................................................................57 7.3 Adjusting the display (contrast, brightness, illumination time of backlight)...........58 7.3.1 Adjusting the contrast of the display .....................................................58 7.3.2 Adjusting the brightness of the display .................................................59 7.3.3 Adjusting the illumination time of the backlight .....................................60 7.3.4 Selecting the format of the standard display (IEC or IEEE) ..................62 7.3.5 Activating color change for alarm .........................................................63 7.3.6 Selecting the refresh time for displaying measured values ...................64 7.3.7 Adjusting the display via the web server ..............................................65 7.4 Device information...............................................................................................66 7.5 Resetting the device to default settings ...............................................................67 Configuration ...........................................................................................................................69 8.1 4 / 192 PHOENIX CONTACT Access and passwords........................................................................................70 8.1.1 Editing access data via the display ......................................................70 8.1.2 Editing access data via the web server ................................................71 8.1.3 Deactivating the configuration via the display ......................................72 8.1.4 Deactivating the Modbus communication interface ..............................73 108904_en_00 Table of contents 8.2 9 Transferring configuration data ............................................................................75 8.2.1 Exporting configuration data ................................................................75 8.2.2 Importing configuration data .................................................................76 8.2.3 Direct transfer of configuration data .....................................................77 Measuring technology ..............................................................................................................79 9.1 Meter readings.....................................................................................................79 9.1.1 Energy meters ......................................................................................80 9.1.2 Energy resettable .................................................................................81 9.1.3 Tariff meter ...........................................................................................82 9.1.4 Operating hours counter ......................................................................83 9.2 Statistics ..............................................................................................................84 9.2.1 Average values ....................................................................................84 10 Functions .................................................................................................................................91 10.1 Digital input..........................................................................................................91 10.1.1 Impulse counter ...................................................................................93 10.1.2 Tariff selection ......................................................................................95 10.1.3 Synchronization of average values ......................................................97 10.1.4 Acknowledgment of alarms ..................................................................99 10.2 Digital output......................................................................................................100 10.2.1 Impulse ..............................................................................................102 10.2.2 Device status .....................................................................................104 10.2.3 Manually ............................................................................................106 10.2.4 Alarm .................................................................................................107 10.2.5 Rotary field direction ..........................................................................112 10.2.6 Deactivating the digital output ............................................................114 10.3 Tariff selection ...................................................................................................116 10.3.1 Tariff selection via the communication interface .................................117 10.3.2 Tariff selection using a time schedule ................................................118 10.4 Logic gate ..........................................................................................................121 10.5 Data logging ......................................................................................................126 10.6 Firmware update................................................................................................129 10.6.1 Execution ...........................................................................................129 10.6.2 Security ..............................................................................................131 11 Communication ......................................................................................................................133 11.1 108904_en_00 Ethernet .............................................................................................................133 11.1.1 IP addressing .....................................................................................133 11.1.2 Configuration of the communication interface ....................................134 11.1.3 Status of the communication interface ...............................................135 11.1.4 Security ..............................................................................................135 PHOENIX CONTACT 5 / 192 EMpro - multi-functional energy measuring devices for front panel installation 11.2 Modbus .............................................................................................................135 11.2.1 Function .............................................................................................135 11.2.2 Modbus/RTU ......................................................................................136 11.2.3 Modbus/TCP ......................................................................................140 11.2.4 Modbus gateway ................................................................................140 11.3 PROFINET ........................................................................................................142 11.3.1 Software .............................................................................................142 11.3.2 Preparing the GSDML file ..................................................................142 11.3.3 Integrating the GSDML file .................................................................142 11.3.4 Integrating hardware ..........................................................................145 11.3.5 Integrating modules and submodules ................................................151 11.3.6 Linking process data ..........................................................................156 11.3.7 Assigning a device name ...................................................................157 11.3.8 Function check ...................................................................................162 11.4 Configuration .....................................................................................................163 11.4.1 Modbus/RTU ......................................................................................163 11.4.2 Modbus/TCP ......................................................................................163 11.4.3 Modbus gateway ................................................................................163 11.5 Security .............................................................................................................164 11.6 Data types and registers ....................................................................................165 11.7 Register table ....................................................................................................167 11.8 Contents of the register table.............................................................................167 11.9 Description of the register table .........................................................................167 12 Technical data .......................................................................................................................173 A Appendixes.............................................................................................................................177 6 / 192 PHOENIX CONTACT A1 List of figures .....................................................................................................177 A2 List of tables ......................................................................................................183 A3 Index..................................................................................................................185 108904_en_00 For your safety 1 For your safety Read this user manual carefully and keep it for future reference. 1.1 Identification of warning notes This symbol indicates hazards that could lead to personal injury. There are three signal words indicating the severity of a potential injury. DANGER Indicates a hazard with a high risk level. If this hazardous situation is not avoided, it will result in death or serious injury. WARNING Indicates a hazard with a medium risk level. If this hazardous situation is not avoided, it could result in death or serious injury. CAUTION Indicates a hazard with a low risk level. If this hazardous situation is not avoided, it could result in minor or moderate injury. This symbol together with the NOTE signal word warns the reader of actions that might cause property damage or a malfunction. Here you will find additional information or detailed sources of information. 1.2 Qualification of users The use of products described in this user manual is oriented exclusively to: – Electrically skilled persons or persons instructed by them. The users must be familiar with the relevant safety concepts of automation technology as well as applicable standards and other regulations. – Qualified application programmers and software engineers. The users must be familiar with the relevant safety concepts of automation technology as well as applicable standards and other regulations. 108904_en_00 PHOENIX CONTACT 7 / 192 EMpro - multi-functional energy measuring devices for front panel installation 1.3 1.3.1 Field of application of the product Intended use The EMpro energy measuring devices described in this user manual are suitable for installation in electrical systems with different voltage levels and performance classes. Keep in mind that electrical systems pose hazards due to high voltages, high short-circuit currents, electric arcs and/or other hazards. 1.3.2 Product changes Modifications to hardware and firmware of the device are not permitted. Incorrect operation or modifications to the device can endanger your safety or damage the device. Do not repair the device yourself. If the device is defective, please contact Phoenix Contact. 1.4 Safety notes WARNING: Risk of death due to electric shock Only use external current transformers with reinforced or double insulation. Install current transformers and corresponding measuring devices only when the power supply of the system is disconnected. – – – – – – – – – – – – – 8 / 192 PHOENIX CONTACT Installation should be carried out as described in the installation notes. Accessing circuits within the device is prohibited. Always disconnect the device from the energy supply before performing any work on it. Short-circuit the secondary side of each current transformer. Use an appropriate voltage measuring device to ensure that no voltage is present. Re-install all the equipment, doors, and covers on the device before switching on the device again. Ensure that the control cabinet is grounded in accordance with DIN EN 61439-1. Ensure that the control cabinet door in which the device is installed is grounded. Provide a switch/circuit breaker close to a device, which is marked as the disconnecting device for this device. Provide overcurrent protection (16 A) for the supply voltage within the installation. To protect the device against mechanical or electrical damage, install it in a suitable housing with an appropriate degree of protection in accordance with IEC 60529. If the device is not used as described in the documentation, the provided protection may be impaired. The housing of the device is equipped with basic insulation against neighboring devices up to 300 V OVC III (overvoltage category). Please note that a minimum clearance of 6 mm to neighboring elements must be maintained to achieve double insulation. The device is maintenance-free. Repairs may only be carried out by the manufacturer. The device must be stopped if it is damaged, was subjected to an impermissible load, stored incorrectly or if it malfunctions. 108904_en_00 For your safety – – 108904_en_00 Check that the measuring device is working correctly by measuring a known voltage and a known current. Ground each current transformer on the secondary side. PHOENIX CONTACT 9 / 192 EMpro - multi-functional energy measuring devices for front panel installation 10 / 192 PHOENIX CONTACT 108904_en_00 Device description 2 Device description The EMpro energy measuring devices (EEM-MA77x types) are universally deployable, high-precision, network-compatible measuring devices with LC display, which can measure, evaluate and process voltages and currents in one, two and three-phase power supply systems. For voltage measurements, up to four inputs are available; for current measurements, up to three inputs are available. You can use EMpro energy measuring devices in TN and IT systems. Typical installation locations of EMpro energy measuring devices are: – Assemblies of switchgear and controlgear, assembly of switchgear and controlgear systems – Control panels – Control desks To enable versatile use, EMpro energy measuring devices are available for the following installation methods: – For front panel installation or with DIN rail adapter, with LC display, with control buttons – For DIN rail installation, with LC display, with control buttons (included in the EMpro product family, but not described in this user manual) – For DIN rail installation, without LC display, without control buttons (included in the EMpro product family, but not described in this user manual) If you use a DIN rail adapter (EEM-MKT-DRA, Order Number 2902078), you can mount EMpro energy measuring devices for front panel installation on a 35 mm DIN rail. Your advantages: – Precise knowledge of load profiles allows load management, optimization of the electrical energy usage and optimization of energy consumption from the public supply network and own production (e.g., CHP, PV system). – Meaningful load profiles are an important aid for planning system expansions and building new systems. – Energy costs can be assigned to individual functional divisions or cost centers. – A transparent overview of the energy flows increases the awareness of energy consumption, uncovers waste of energy and makes it possible to identify energy-intensive system components and equipment that harbors potential energy savings. – Critical system states can be detected, reported and registered. Such critical system states can, e.g., be caused by overload, unbalanced load, undervoltage, voltage and current distortion by non-linear consumers, etc. Detection of critical system states makes it possible to quickly react to such states in order to prevent potential decreases in availability or energy supply failures. When critical system states are detected in time, measures can be taken to ensure permanent system availability. – Seamless communication with control systems via Modbus/RTU, Modbus/TCP, PROFINET and EtherNet/IP™ and with higher-level energy management systems via standard TCP/IP networks (Ethernet, RJ45) – Intuitive configuration and operation of EMpro energy measuring devices with four front buttons or integrated web server 108904_en_00 PHOENIX CONTACT 11 / 192 EMpro - multi-functional energy measuring devices for front panel installation Numerous parameters that are important for operating an electrical system are determined by means of the voltages and currents measured by the EMpro energy measuring devices. Apparent power, active power and reactive power are measured in all four quadrants (consumption, supply). EMpro energy measuring devices have an integrated web server. It enables: – Convenient configuration – Data logging – Mains quality evaluations – Detailed recording of energy flows A configurable digital input and a configurable digital output are also available. Communication interfaces to higher-level control systems are integrated in the device, depending on the type. Currents can be measured with current transformers or Rogowski coils. If you use Rogowski coils, you do not need an external measuring transducer. EMpro energy measuring devices can be connected directly to Rogowski coils from any manufacturer. Different device types are deployed depending on whether current transformers or Rogowski coils are used. Voltages can be measured directly, or by means of voltage transducers. Voltages and currents are measured using the principle of true r.m.s. value measurement (TRMS) up to the 63rd harmonic, which enables detailed assessment of the mains quality. When EMpro energy measuring devices with LC display are used, it is possible to locally display measurement values and perform configuration tasks locally by means of buttons. All EMpro energy measuring devices have a Modbus communication interface and an integrated web server. Other communication interfaces are available, depending on the type. Via the web server, all relevant measurement values and parameters can be displayed and the energy measuring devices can be configured. On the web interface, settings can be configured for the following, among others: – Grid types – Average values – Four energy meters for apparent power, active power, reactive power, consumption/supply – Energy tariff meter – Logging – Alarms and behavior in the event of alarms – Network (TCP/IP) – Interfaces with higher-level control systems – Digital output (with logic functions) – Digital input – Impulse counter – Date/time (realtime clock, SNTP compatible) – Identifier (of metering point) – Display 12 / 192 PHOENIX CONTACT 108904_en_00 Device description Other features of the EMpro energy measuring devices are: – Firmware update function – Password protection (local and web-based management (WBM)) – Deactivation of control buttons for configuration – Sealable connection fields – Export, import and direct transfer of configuration data – Color changes on display (white, red) in the event of errors/events The following measurement values/parameters are shown on the LC displays of EMpro energy measuring devices: – Voltage U [V] (L-L, L-N) – Current I [A] – Frequency f [Hz] – Active power P [W] (string, total) – Reactive power Q [var] (string, total) – Apparent power S [VA] (string, total) – Power factor PF, λ – Active power factor, active factor cos Φ – Phase shift angle, phase angle Φ (U-U, U-I) – Total harmonic distortion (ratio) of the voltage, THD U (L-L, L-N) – Total harmonic distortion (ratio) of the current, THD I – Energy E [Wh, varh, VAh] (consumption/supply) – Energy tariff meter E [Wh, varh, VAh] (consumption, supply, meter 1-4) For the measurement values/parameters voltage U (L-L), U (L-N), current I, frequency f, active power P, reactive power Q and apparent power S, it is possible to switch between: – Instantaneous = Instantaneous value – Min = Minimum value (can be reset) – Max = Maximum value (can be reset) – AVG = Current average value – AVG Min = Minimum average value (can be reset) – AVG Max = Maximum average value (can be reset) All the measures described above are also available via the web server that has been integrated into the EMpro energy measuring device. In the web browser, the data cannot only be displayed numerically, but also in the form of a convenient analog display with trend charts. A variety of hardware and software interfaces can be used to communicate with higher-level control systems. At the time this document is written, the following interfaces are available: – Modbus/RTU (RS-485) – Modbus/TCP (Ethernet) – PROFINET (Ethernet, Dual Port) – EtherNet/IP (Ethernet, Dual Port) 108904_en_00 PHOENIX CONTACT 13 / 192 EMpro - multi-functional energy measuring devices for front panel installation A variety of parameters from the EMpro energy measuring device can be read or configured in order to communicate with higher-level control systems. These parameters, the associated addresses, additional information and help texts are available on the web server. All information required for setting up communication with higher-level control systems is contained in a register table on the integrated web server. It is therefore usually not necessary to look up parameters in the paper copy of the documentation. The register table contains: – Device data – Device information – Device configuration (digital input/digital output) – Network (TCP/IP) – Interfaces for higher-level control systems (e.g., Modbus/RTU, Modus/TCP, PROFINET, EtherNet/IP™) – Control and status registers – Device control – Device status – Measuring system control – Process data – Measured values – Counter values – Impulse counter – Statistics – Total harmonic distortion THD – Harmonics – Voltage quality 14 / 192 PHOENIX CONTACT 108904_en_00 Device description 2.1 Product overview Table 2-1 Product overview Description Current transformer Rogowski connection Modbus/TCP EEM-MA770 EEM-MA771 2907945 2908286 EEM-MA770-R EEM-MA771-R 2907944 2908285 Modbus/TCP + PROFINET EEM-MA770-PN EEM-MA771-PN 2907946 2908301 Modbus/TCP + Ethernet/IP EEM-MA770-EIP EEM-MA771-EIP 2907953 2908302 Modbus/TCP + Modbus/RTU 108904_en_00 Front panel devices Current measuring input PHOENIX CONTACT 15 / 192 EMpro - multi-functional energy measuring devices for front panel installation 16 / 192 PHOENIX CONTACT 108904_en_00 Mounting and installation 3 Mounting and installation 3.1 Mounting You can install the device in a front panel or control cabinet door. 5 B A Figure 3-1 Mounting B A B Figure 3-2 A Mounting terminal covers To ensure a firm and tight fit of the device in accordance with IEC 60529/EN 60529, proceed as follows during mounting: 1. Stretch the seal over the rear of the device and position it against the inside of the display. 2. Push the device into the mounting opening from the front. Ensure that the seal is positioned correctly. 3. Secure the device from the rear using the four retaining elements until the device snaps firmly into place. 4. Safeguard the voltage and current measurement inputs against unauthorized access by installing terminal covers. 108904_en_00 PHOENIX CONTACT 17 / 192 EMpro - multi-functional energy measuring devices for front panel installation 3.2 Installation DANGER: Risk of electric shock If the device is disconnected, the secondary side of the relevant current transformers must be short circuited. Install the current sensors and corresponding measuring devices only when the power supply of the system is disconnected. When the current transformer is operated with an open secondary circuit, hazardous voltages may occur at the secondary terminal blocks. When measuring by means of current transformers or Rogowski coils, the accuracy is greatly influenced by the quality of the current sensors used. 18 / 192 PHOENIX CONTACT 108904_en_00 Mounting and installation 3.2.1 Pin assignment 3.2.1.1 Current transformer Maximum tightening torque for the relevant screws: 0.5 Nm ... 0.6 Nm. I1 I2 I3 S1 S2 S1 S2 S1 S2 ETH Figure 3-3  DO DI - + - + VN V3 V2 V1 N(L) L Pin assignment example I1, I2, I3 Current measuring input, current transformer DI+, DI- Digital input DO+, DO- Digital output L, N(L) Supply V1, V2, V3, VN Voltage measuring input  FE Functional ground RJ45 Ethernet connection (Modbus) LED Status Optional (depending on the version): 1 x RS-485 RS-485 connection (Modbus/RTU) 2 x ETH RJ45 Ethernet connection (PROFINET) Ethernet connection (EtherNet/IP) 108904_en_00 PHOENIX CONTACT 19 / 192 EMpro - multi-functional energy measuring devices for front panel installation 3.2.1.2 Rogowski coil RC1 RC2 RC3 W1 B1 W2 B2 W3 B3 ETH Figure 3-4  DO DI - + - + VN V3 V2 V1 N(L) L Pin assignment example RC1, RC2, RC3 Current measuring input, Rogowski coil DI+, DI- Digital input DO+, DO- Digital output L, N(L) Supply V1, V2, V3, VN Voltage measuring input  FE Functional ground RJ45 Ethernet connection (Modbus) LED Status Optional (depending on the version): 1 x RS-485 RS-485 connection (Modbus/RTU) 2 x ETH RJ45 Ethernet connection (PROFINET) Ethernet connection (EtherNet/IP) 20 / 192 PHOENIX CONTACT 108904_en_00 Mounting and installation 3.2.2 Supply You can connect the device supply as follows: 1. Connection (L/N) 2. Connection (L/L) Connection L/N L N(L) L1´ L2´ L3´ N´ PE´ L1 L2 L3 N PE Figure 3-5 Connection L/N Connection L/L L L L1´ L2´ L3´ N´ PE´ L1 L2 L3 N PE Figure 3-6 Connection L/L Supply voltage range: 100 V AC ... 400 V AC ±20% 150 V DC ... 250 V DC ±20% Fuse: 108904_en_00 16 A PHOENIX CONTACT 21 / 192 EMpro - multi-functional energy measuring devices for front panel installation 3.2.3 Grid types The device is designed for connection to various network types in two-, three- or four-conductor networks with symmetrical or asymmetrical load. Where current sensors are concerned, a differentiation is made between current transformers and Rogowski coils, depending on the device type. The definitions of the grid types are as follows: 1PH One-phase network 2W Two conductors 1CT One current transformer Alternative: 1RC 3.2.3.1 One Rogowski coil Current transformer (CT) 1PH-2W-1CT V1 V2 V3 VN 6 I1 I2 I3 S1 S2 S1 S2 S1 S2 L1 L2 L3 N PE L1´ L2´ L3´ N´ PE´ Figure 3-7 One-phase network, two conductors, one current transformer 2PH-2W-1CT V1 V2 V3 VN L1 L2 L3 N PE Figure 3-8 22 / 192 PHOENIX CONTACT 6 I1 I2 I3 S1 S2 S1 S2 S1 S2 L1´ L2´ L3´ N´ PE´ Two-phase network, two conductors, one current transformer 108904_en_00 Mounting and installation 3PH-3W-1CT V1 V2 V3 VN 6 I1 I2 I3 S1 S2 S1 S2 S1 S2 L1 L2 L3 N PE L1´ L2´ L3´ N´ PE´ Figure 3-9 Three-phase network, three conductors, one current transformer 3PH-3W-2CT V1 V2 V3 VN 6 I1 I2 I3 S1 S2 S1 S2 S1 S2 L1 L2 L3 L1´ L2´ L3´ PE PE´ Figure 3-10 Three-phase network, three conductors, two current transformers 3PH-3W-3CT V1 V2 V3 VN 6 I1 I2 I3 S1 S2 S1 S2 S1 S2 L1 L2 L3 N PE L1´ L2´ L3´ N´ PE´ Figure 3-11 Three-phase network, three conductors, three current transformers 3PH-4W-1CT V1 V2 V3 VN L1 L2 L3 N PE Figure 3-12 108904_en_00 6 I1 I2 I3 S1 S2 S1 S2 S1 S2 L1´ L2´ L3´ N´ PE´ Three-phase network, four conductors, one current transformer PHOENIX CONTACT 23 / 192 EMpro - multi-functional energy measuring devices for front panel installation 3PH-4W-3CT V1 V2 V3 VN 6 I1 I2 I3 S1 S2 S1 S2 S1 S2 L1 L2 L3 N PE L1´ L2´ L3´ N´ PE´ Figure 3-13 Three-phase network, four conductors, three current transformers 2PH-3W-2CT V1 V2 V3 VN L1 L2 L3 N PE Figure 3-14 24 / 192 PHOENIX CONTACT 6 I1 I2 I3 S1 S2 S1 S2 S1 S2 L1´ L2´ L3´ N´ PE´ Two-phase network, three conductors, two current transformers 108904_en_00 Mounting and installation 3.2.3.2 Rogowski coil (RCP) 1PH-2W-1RC V1 V2 V3 VN 6 RC1 RC2 RC3 W1 B1 W2 B2 W3 B3 L1 L2 L3 N PE L1´ L2´ L3´ N´ PE´ Figure 3-15 One-phase network, two conductors, one Rogowski coil 2PH-2W-1RC V1 V2 V3 VN 6 RC1 RC2 RC3 W1 B1 W2 B2 W3 B3 L1 L2 L3 N PE L1´ L2´ L3´ N´ PE´ Figure 3-16 Two-phase network, two conductors, one Rogowski coil 3PH-3W-1RC V1 V2 V3 VN 6 RC1 RC2 RC3 W1 B1 W2 B2 W3 B3 L1 L2 L3 N PE L1´ L2´ L3´ N´ PE´ Figure 3-17 Three-phase network, three conductors, one Rogowski coil 3PH-3W-3RC V1 V2 V3 VN L1 L2 L3 N PE Figure 3-18 108904_en_00 6 RC1 RC2 RC3 W1 B1 W2 B2 W3 B3 L1´ L2´ L3´ N´ PE´ Three-phase network, three conductors, three Rogowski coils PHOENIX CONTACT 25 / 192 EMpro - multi-functional energy measuring devices for front panel installation 3PH-4W-1RC V1 V2 V3 VN 6 RC1 RC2 RC3 W1 B1 W2 B2 W3 B3 L1 L2 L3 N PE L1´ L2´ L3´ N´ PE´ Figure 3-19 Three-phase network, four conductors, one Rogowski coil 3PH-4W-3RC V1 V2 V3 VN 6 RC1 RC2 RC3 W1 B1 W2 B2 W3 B3 L1 L2 L3 N PE L1´ L2´ L3´ N´ PE´ Figure 3-20 Three-phase network, four conductors, three Rogowski coils 2PH-3W-2RC V1 V2 V3 VN L1 L2 L3 N PE Figure 3-21 26 / 192 PHOENIX CONTACT 6 RC1 RC2 RC3 W1 B1 W2 B2 W3 B3 L1´ L2´ L3´ N´ PE´ Two-phase network, three conductors, two Rogowski coils 108904_en_00 Operating and indication elements 4 Operating and indication elements EMpro 1 400,00 V U23 400,00 V U31 400,00 V U12 23456 1 1 2 3 2 3 4 2 3 LCD display, two-color backlit Pulse LED Operating buttons 1...4 for displaying measured values and for changing the configuration 4.1 Technical data of the display Technical data 108904_en_00 Display technology FSTN positive, transflective Resolution of devices for installation on front panel 170 x 128 Viewing angle Min. 30° (horizontal and vertical) Backlight White and red PHOENIX CONTACT 27 / 192 EMpro - multi-functional energy measuring devices for front panel installation 4.2 Table 4-1 Icon Displaying the events Displaying the events Meaning Voltage transducer configured Measured values faulty (flashing) Tariff 1 set Tariff 2 set Tariff 3 set Tariff 4 set Network connected Warning User logged in User logged out 28 / 192 PHOENIX CONTACT 108904_en_00 Operating and indication elements 4.3 Table 4-2 Icon Operating elements on the display (softkeys) Meaning of the softkeys Meaning Open/close settings menu Scroll up Scroll down Select menu page Exit menu page Edit setting Apply modified setting Increment (increase) Decrement (decrease) Next position Confirm query Reject query/first configuration: go back to start Reset: The displayed values are reset. 108904_en_00 PHOENIX CONTACT 29 / 192 EMpro - multi-functional energy measuring devices for front panel installation 30 / 192 PHOENIX CONTACT 108904_en_00 Basic device configuration 5 Basic device configuration The first time the energy measuring device is switched on, the installation wizard for the first configuration (basic device configuration) automatically starts. In the basic device configuration, you can edit the default settings of the device. Depending on the requirements, you can perform the basic device configuration via the display or via the integrated web server. Menu-driven configuration is available for the following parameters: – Language – Network settings – Grid type – Current input – Voltage input 5.1 1. To start the first configuration (basic device configuration) of your energy measuring device, press the button. Figure 5-1 5.1.1 Figure 5-2 1. 2. 108904_en_00 Basic device configuration via the display Starting the basic device configuration Step 1: Language selection Language selection Use the and buttons to select the desired language. To proceed, press the button. PHOENIX CONTACT 31 / 192 EMpro - multi-functional energy measuring devices for front panel installation 5.1.2 Figure 5-3 1. 2. Figure 5-4 32 / 192 PHOENIX CONTACT Network settings If you do not want to edit the network settings, press the button. If you want to edit the network settings, press the button. 5.1.3 1. 2. 3. 4. 5. Step 2: Network settings Step 3: IPv4 IPv4 To enter a network setting, use the or button to scroll to the desired setting. To open edit mode, press the button. To scroll through the possible values, use the buttons and . Next, apply the settings by pressing the button. After you have entered all settings, press the button to proceed. 108904_en_00 Basic device configuration 5.1.4 Step 4: Grid type Current transformer Figure 5-5 Selection of grid type with current transformers Rogowski coil Figure 5-6 1. 2. Selection of grid type with Rogowski coils Use the or button to select the desired grid type. To proceed, press the button. Explanations and information on the various grid types are available in Section “Grid types” on page 22. 108904_en_00 PHOENIX CONTACT 33 / 192 EMpro - multi-functional energy measuring devices for front panel installation 5.1.5 Figure 5-7 1. 2. 3. Step 5a: Current input (energy measuring device with current transformer) Current input (energy measuring device with current transformer) To open the edit mode for the “Primary” device setting, press the To set the primary current, press the buttons and . To apply the change, press the button. button. To set the secondary current, proceed in the same way as for setting the primary current. 4. 5. 34 / 192 PHOENIX CONTACT To invert the current inputs, activate the checkbox below the appropriate current input with the button. To continue the basic device configuration, press the button. 108904_en_00 Basic device configuration 5.1.6 Figure 5-8 1. 2. 3. Step 5b: Current input (energy measuring device with Rogowski coil) Current input (energy measuring device with Rogowski coil) Use the button to open the edit mode of the “Manufacturer” device setting. To make changes, use the buttons and . To apply the change, press the button. The same procedure applies to editing the nominal current. 4. 5. To activate or deactivate a checkbox, press the button. To continue the basic device configuration, press the button. 5.1.7 Figure 5-9 1. 2. 3. 4. 5. 6. 108904_en_00 Step 6: Voltage input Voltage input If you use a voltage transducer, activate the checkbox using the button. When you activate the checkbox, the primary and secondary voltage is displayed. If no voltage transducer is used, enter the nominal voltage by means of the buttons and . Select it with the button. Use the buttons and to make changes. To save the changes, press the button. To proceed, press the button. PHOENIX CONTACT 35 / 192 EMpro - multi-functional energy measuring devices for front panel installation 5.1.8 Figure 5-10 1. 2. 3. Figure 5-11 2. 36 / 192 PHOENIX CONTACT Configuration conclusion Use the buttons and to check your configured settings. If you are satisfied with the first configuration, finish it by pressing the To restart the first configuration, press the button. 5.1.9 1. Step 7: Configuration overview button. Step 8: Setting a personal PIN Setting a personal pin To ensure safe operation, you can select a personal PIN. To this end, press the button. If you do not want to change the PIN, press the button. 108904_en_00 Basic device configuration 5.1.10 Step 9: Activating the PIN Figure 5-12 1. 2. 3. 4. Activating the PIN To activate the PIN, press the button. Use the buttons and to enter the desired PIN. To apply the changes, press the button. To finish the basic device configuration, press the button. To ensure safe operation, we recommend changing the access data for the display! For additional information, please refer to Section “Configuration” on page 69. 5.2 Basic device configuration via the web server We recommend using the integrated web server to perform the device configuration. You can access the web server directly after you have switched on the device. An installation wizard guides you through the basic device configuration process. By default, a static IP address is set for the device. To start the basic device configuration via the web server, open the Internet browser. Enter the following URL: IP address: 192.168.1.2 Subnet mask: 255.255.255.0 Default gateway: 0.0.0.0 DHCP: Off DNS server: 0.0.0.0 Make sure that your computer and the energy measuring device are in the same network. 108904_en_00 PHOENIX CONTACT 37 / 192 EMpro - multi-functional energy measuring devices for front panel installation 5.2.1 Step 1: Network settings The first step in the basic device configuration is the network settings. Navigation on the web server “Network settings” Figure 5-13 Network settings Status Here, an overview of the current network configuration is displayed. Settings Enter the desired network settings as appropriate for the respective application. 38 / 192 PHOENIX CONTACT 108904_en_00 Basic device configuration 5.2.2 Step 2: Selecting the grid type The second step is the selection of the grid type for the application. Figure 5-14 Grid type Taking the device installation into account, select the desired grid type from the options provided in the overview. 108904_en_00 PHOENIX CONTACT 39 / 192 EMpro - multi-functional energy measuring devices for front panel installation 5.2.3 Step 3: Configuration of the current input (current transformer) Depending on the device selection and the associated device-specific current sensors, the current input setting may vary. Configuring the current input is the third step of the basic device configuration. Figure 5-15 Current input, current transformer Primary Enter the primary current of the application here. Secondary Select the secondary current (1 A or 5 A) of the current transformer. Invert With this function, the respective phase of the current transformer is inverted by the firmware. It is no longer necessary to rewire the two conductors. 40 / 192 PHOENIX CONTACT 108904_en_00 Basic device configuration 5.2.4 Step 3: Configuration of the current input (Rogowski coil) Depending on the device selection and the associated device-specific current sensors, the current input setting may vary. Configuring the current input is the third step of the basic device configuration. Figure 5-16 Current input (Rogowski coil) Primary Enter the primary current of the application here. Preselection Select a Rogowski coil from Phoenix Contact. You do not have to configure any other settings. 108904_en_00 PHOENIX CONTACT 41 / 192 EMpro - multi-functional energy measuring devices for front panel installation Invert I1 With this function, the respective phase of the Rogowski coil is inverted by the firmware. It is no longer necessary to rewire the two conductors. If you use Rogowski coils from manufacturers other than Phoenix Contact, you have to configure additional settings. Transmission factor Enter the amplitude transmission factor (mV/kA) of the Rogowski coil. Refer to the documentation of the Rogowski coil for the amplitude transmission factor. Internal resistance Enter the internal resistance (Ω) of the Rogowski coil. Refer to the documentation of the Rogowski coil for the internal resistance. Invert 42 / 192 With this function, the respective phase of the Rogowski coil is inverted by the firmware. It is no longer necessary to rewire the two conductors. PHOENIX CONTACT 108904_en_00 Basic device configuration 5.2.5 Step 4: Voltage input If you use a voltage transducer in your application, activate the checkbox here. Subsequently follow the next steps. Figure 5-17 108904_en_00 Voltage input PHOENIX CONTACT 43 / 192 EMpro - multi-functional energy measuring devices for front panel installation 5.2.6 Figure 5-18 Optional: Voltage transducer Voltage input with voltage transducer Primary Enter the primary voltage of the voltage transducer. Secondary Enter the secondary voltage of the voltage transducer. 44 / 192 PHOENIX CONTACT 108904_en_00 Basic device configuration 5.2.7 Figure 5-19 Step 5: Configuration overview Configuration overview Check all settings and close the basic device configuration. For your own safety, we recommend changing the access data for the web server! 108904_en_00 PHOENIX CONTACT 45 / 192 EMpro - multi-functional energy measuring devices for front panel installation 46 / 192 PHOENIX CONTACT 108904_en_00 Navigation structure and display 6 Navigation structure and display 6.1 Figure 6-1 108904_en_00 Menu structure on the display Menu structure on the display PHOENIX CONTACT 47 / 192 EMpro - multi-functional energy measuring devices for front panel installation 6.2 Figure 6-2 48 / 192 PHOENIX CONTACT Menu structure on the web server Menu structure on the web server 108904_en_00 Navigation structure and display The figure shows the start screen of the web server in operating mode after the basic device configuration has been completed. The following information appears in the header: – Order designation – Equipment identification (EID) of the device, which you can name as desired – A defined measuring point, which you can name as desired – Language selection The menu tree contains the following: 108904_en_00 Home: Reading measured data and measurement values Settings: Configuring the device and device parameters System: Managing rights and provision of information and data PHOENIX CONTACT 49 / 192 EMpro - multi-functional energy measuring devices for front panel installation 50 / 192 PHOENIX CONTACT 108904_en_00 Device settings and information 7 Device settings and information 7.1 Selecting the language The languages for the display and the web server can differ. Thus, changing the language via the display does not affect the language set in the web server, and vice versa. Navigation on the display “Language” Figure 7-1 “Language” menu Figure 7-2 Language selection You can select the display language via the display. The default setting for the language is English. 108904_en_00 PHOENIX CONTACT 51 / 192 EMpro - multi-functional energy measuring devices for front panel installation 7.2 Date and time When the device is switched off, or in the event of a power loss, the device retains the system time for at least one day. This is usually adequate for maintenance and installation work. 7.2.1 Navigation on the display Reading the date and time “Date / Time” Figure 7-3 “Date / Time” menu Figure 7-4 Settings: “Date / Time” On the device display, you can only read the date and time settings. The date and time settings can only be changed via the integrated web server or the Modbus communication interface. The web server provides the following modes for setting the date and time: – Manually – SNTP server 52 / 192 PHOENIX CONTACT 108904_en_00 Device settings and information 7.2.2 Navigation on the web server Setting the date and time manually “Settings, Date / Time, Settings, Manually” mode Figure 7-5 “Settings, Date / Time, Settings, Manually” mode Status Here, the current date and current time are shown. Settings Here, you can change the settings for the date and time. Time zone Here, you can select a time zone. You can find a list of all time zones in Section “Time zones” on page 55. Summer time rule Here, you can select a summer time rule. A description of the summer time rules can be found in Section “Summer time rule” on page 57. 108904_en_00 PHOENIX CONTACT 53 / 192 EMpro - multi-functional energy measuring devices for front panel installation 7.2.3 Navigation on the web server Synchronizing the date and time with an SNTP server “Settings, Date / Time, Settings, SNTP Server” mode Figure 7-6 Menu: “Settings, Date / Time, Settings, SNTP Server” mode Settings Here, you can change the settings for the date and time. Mode Via the “SNTP server” Modbus, the internal clock of the device is automatically synchronized with an SNTP server (Simple Network Time Protocol). SNTP server Enter the address or the URL of the SNTP server and check the entered address by clicking “check connection”. Polling cycle Enter the desired polling rate in seconds (s). Time zone Here, you can select a time zone. You can find a list of all time zones in Section “Time zones” on page 55. Summer time rule Here, you can select a summer time rule. A description of the summer time rules can be found in Section “Summer time rule” on page 57. 54 / 192 PHOENIX CONTACT 108904_en_00 Device settings and information 7.2.4 Navigation on the web server Time zones “Settings, Date / Time, Settings, Time zone” GMT -12:00 GMT -11:00 Pacific (Midway, Niue, Samoa) GMT -10:00 Pacific (Hawaii, Honolulu, Tahiti) GMT -09:30 Pacific (Marquesas) GMT -09:00 America (Anchorage, Yakutat, Alaska) GMT -08:00 America (Los Angeles, Vancouver, Tijuana) GMT -07:00 America (Denver, Edmonton, Phoenix, Yellowknife) GMT -06:00 America (Chicago, Cancun, Mexico City, Costa Rica, Winnipeg) GMT -05:00 America (Cayman, Bogota, Havana, Lima, New York, Panama, Toronto) GMT -04:30 America (Caracas) GMT -04:00 America (Asuncion, Barbados, Grenada, Santiago) GMT -03:30 America (St. Johns), Canada (Newfoundland) GMT -03:00 America (Buenos Aires, Cordoba, Bahia, Recife, Sao Paulo) GMT -02:00 America (Noronha), Atlantic (South Georgia) GMT -01:00 Atlantic (Azores, Cape Verde) GMT 00:00 Africa (Accra, Dakar) Europa (Lisbon, Madeira, Reykjavik, Dublin, London) GMT +01:00 Africa (Lagos, Tunis) Europe (Amsterdam, Belgrade, Berlin, Brussels, Copenhagen, Paris, Rome) GMT +02:00 Africa (Cairo, Johannesburg) Europe (Helsinki, Athens, Riga, Sofia) GMT +03:00 Africa (Mogadishu, Nairobi), Asia (Baghdad, Bahrain, Kuwait, Qatar), Europe (Minsk, Kaliningrad) GMT +04:00 Asia (Tehran, Baku, Dubai) Europe (Moscow, Volgograd) India (Mahe, Mauritius, Reunion) GMT +04:30 Asia (Kabul) GMT +05:00 Asia (Dushanbe, Tashkent) India (Maldives) 108904_en_00 GMT +05:30 Asia (Calcutta, Colombo) GMT +05:45 Asia (Kathmandu) GMT +06:00 Asia (Almaty, Bishkek, Dacca, Yekaterinburg, Thimbu) GMT +06:30 Asia (Rangoon), India (Cocos) GMT +07:00 Asia (Bangkok, Jakarta, Novosibirsk, Omsk) PHOENIX CONTACT 55 / 192 EMpro - multi-functional energy measuring devices for front panel installation GMT +08:00 Asia (Brunei, Hong Kong, Kuala Lumpur, Singapore, Taipei, Manila), Australia (Perth, West) GMT +08:45 Australia (Eucla) GMT +09:00 Asia (Irkutsk, Seoul, Tokyo) GMT +09:30 Australia (Adelaide, Darwin, North, South) GMT +10:00 Asia (Yakutsk) Australia (Brisbane, Melbourne, Queensland, Sydney, Tasmania) GMT +11:00 Asia (Vladivostok) GMT +11:30 Pacific (Norfolk) GMT +12:00 Asia (Kamchatka) Pacific (Guadalcanal) Pacific (Auckland, Fiji, Majuro) 56 / 192 PHOENIX CONTACT GMT +12:45 Pacific (Chatham) GMT +13:00 Pacific (Apia, Enderbury, Tongatapu) GMT +14:00 Pacific (Kiritimati) 108904_en_00 Device settings and information 7.2.5 Navigation on the web server Summer time rule “Settings, Date / Time, Settings, Summer time rule” Figure 7-7 Menu: “Settings, Date / Time, Settings, Summer time rule” Status Here, the current date and current time are shown. Settings Here, you can change the settings for the date and time. You can select the summer time rule for Europe or the USA, or set a summer time rule manually. If you set the summer time rule manually, you can specify the start and end of the summer time rule: – Month – Day of week – Hours – Minutes 108904_en_00 PHOENIX CONTACT 57 / 192 EMpro - multi-functional energy measuring devices for front panel installation 7.3 7.3.1 Navigation on the display Adjusting the display (contrast, brightness, illumination time of backlight) Adjusting the contrast of the display “Display, Contrast” Contrast Figure 7-8 Menu: “Display, Contrast” Figure 7-9 Settings: “Display, Contrast” You can set the contrast of the display. The default setting for the contrast is 50%. 58 / 192 PHOENIX CONTACT 108904_en_00 Device settings and information 7.3.2 Navigation on the display Adjusting the brightness of the display “Display, Brightness“ Figure 7-10 Menu: “Display, Brightness“ Figure 7-11 Settings: “Display, Brightness“ You can adjust the brightness of the display. The default setting for the brightness of the display is 100%. 108904_en_00 PHOENIX CONTACT 59 / 192 EMpro - multi-functional energy measuring devices for front panel installation 7.3.3 Navigation on the display 60 / 192 PHOENIX CONTACT Adjusting the illumination time of the backlight “Display, Permanent light” Figure 7-12 Menu: “Display, Permanent light” Figure 7-13 Settings: “Display, Permanent light” 108904_en_00 Device settings and information Permanent light When the “Permanent light” checkbox is enabled, the white backlight of the display is on permanently. Figure 7-14 Settings: “Illumination time” Permanent light When the “Permanent light” checkbox is disabled, the white backlight of the display is off. Illumination duration When the “Permanent light” checkbox is disabled, you can freely define the duration for which the backlight remains lit. The default setting for the illumination time is 20 seconds. You can also change the settings for the illumination time via the web server. 108904_en_00 PHOENIX CONTACT 61 / 192 EMpro - multi-functional energy measuring devices for front panel installation 7.3.4 Navigation on the display Standard display Selecting the format of the standard display (IEC or IEEE) “Display, Standard display” Figure 7-15 Menu: “Display, Standard display” Figure 7-16 Settings: “Display, Standard display” You can choose between the formats IEC and IEEE for displaying the measured values and the associated units. The default setting is IEC. You can also change the format for the standard displays via the web server (see Section “Adjusting the display via the web server” on page 65). 62 / 192 PHOENIX CONTACT 108904_en_00 Device settings and information 7.3.5 Navigation on the display Alarm light Activating color change for alarm “Display, Alarm light” Figure 7-17 Menu: “Display, Alarm light” Figure 7-18 Settings: “Display, Alarm light” The backlight of the display can change from white to red in the event of an error (color change). When the “Alarm light” checkbox is enabled, the color change is active. In the default setting, the color change is enabled. You can also change the settings for the alarm light via the web server (see “Red color change in case of error” on page 65). 108904_en_00 PHOENIX CONTACT 63 / 192 EMpro - multi-functional energy measuring devices for front panel installation 7.3.6 Navigation on the display Refresh time Selecting the refresh time for displaying measured values “Display, Refresh time” Figure 7-19 Menu: “Display, Refresh time” Figure 7-20 Settings: “Display, Refresh time” You can choose between three refresh times for displaying the measured values: – 500 ms – 1s – 2s The default setting for the refresh time is 1 s. 64 / 192 PHOENIX CONTACT 108904_en_00 Device settings and information 7.3.7 Navigation on the web server Adjusting the display via the web server “Settings, Display” Figure 7-21 Web server: “Settings, Display” Status Here, the current settings for the display are shown. It is also possible to modify them here. Standard display Here, you can choose between the formats “IEC” or “IEEE”. Activate configuration via display If this checkbox has been enabled, you can configure the device via the display. Illumination duration Here, you can select between: – Steady off – Set duration (in hh:mm:ss) – Steady on Red color change in case of error If this checkbox is enabled, the color change in the event of an error is active. If this checkbox is disabled, the color change in the event of an error is inactive. In the default setting, this checkbox is enabled. 108904_en_00 PHOENIX CONTACT 65 / 192 EMpro - multi-functional energy measuring devices for front panel installation 7.4 Navigation on the display Device information “Device info” Figure 7-22 Menu “Device info” Figure 7-23 Display “Device info” The following device information can be read on the display: – Hardware version – Firmware version – Device label – Article number – UUID – Date and time of production – Serial number 66 / 192 PHOENIX CONTACT 108904_en_00 Device settings and information – Bootloader revision 7.5 Navigation on the display Resetting the device to default settings “System, Factory reset” Figure 7-24 Menu: “System, Factory reset” Figure 7-25 Menu: “System, Factory reset” With the device PIN, the device can be reset to the default settings. In the process, all configurations are lost and the device is returned to the delivery state. 108904_en_00 PHOENIX CONTACT 67 / 192 EMpro - multi-functional energy measuring devices for front panel installation 68 / 192 PHOENIX CONTACT 108904_en_00 Configuration 8 Configuration The device configuration is set by default as follows. Configuration via the display You can use the control buttons on the front of the device to enter the basic device configuration and configure settings on the display. Configuration via web server The web server is the tool provided for device configuration. In addition to offering intuitive operation, it has been designed for not only entering the basic device configuration, but also for performing all other configurations. Configuration via Modbus In addition to the web server, the Modbus communication interface can also be used for device configuration. 108904_en_00 PHOENIX CONTACT 69 / 192 EMpro - multi-functional energy measuring devices for front panel installation 8.1 Access and passwords For your own safety, change the access data. 8.1.1 Navigation on the display Editing access data via the display “System, PIN xxxx” Figure 8-1 Menu: “System, PIN xxxx” Figure 8-2 Settings: “System, PIN xxxx” The default setting for the PIN is “0100”. 1. 2. Under “PIN”, change the preset PIN for access permission. Subsequently apply it by confirming the change. In addition to the option to change the PIN, the device also offers an option for deactivating the PIN. 70 / 192 PHOENIX CONTACT 108904_en_00 Configuration 8.1.2 Navigation on the web server Editing access data via the web server “System, User management, Change password” Figure 8-3 Menu: “System, User management, Change password” The default setting for the password is “adm1n”. 1. 2. 108904_en_00 Under “Change password”, change the preset password for access permission. Confirm the change by clicking the “Change password” button. PHOENIX CONTACT 71 / 192 EMpro - multi-functional energy measuring devices for front panel installation 8.1.3 Navigation on the web server Deactivating the configuration via the display “Settings, Display” Figure 8-4 Menu: “Settings, Display” The device provides an option for protection against manipulative access: You can prevent access to the device and thus changes to the configured data by disabling the “Activate configuration via display” checkbox. You can continue to use the control buttons of the device to read measurement values. If the “Activate configuration via display” checkbox is disabled, it is not possible to use the function for deactivating the web server. The display and web server cannot be deactivated simultaneously. 72 / 192 PHOENIX CONTACT 108904_en_00 Configuration 8.1.4 Deactivating the Modbus communication interface You can prevent device access via the Modbus communication interface by deactivating the communication interface (“WBM active”). Navigation on the display 108904_en_00 “System, PIN active/WBM active (web-based management)” Figure 8-5 Menu: “System, PIN active/WBM active” Figure 8-6 Setting: “System, WBM active” Figure 8-7 Setting: “System, PIN active” PHOENIX CONTACT 73 / 192 EMpro - multi-functional energy measuring devices for front panel installation If you disable the “WBM active” checkbox, the device no longer allows access via the communication interface. Through this deactivation, access to the web server is also prohibited. This precludes use of the function for deactivating the control buttons. The display and web server cannot be deactivated simultaneously. 74 / 192 PHOENIX CONTACT 108904_en_00 Configuration 8.2 Transferring configuration data If you want to apply existing configurations to other devices, you can transmit the configuration data as follows: – Exporting configuration data – Importing configuration data – Direct transfer of configuration data 8.2.1 Navigation on the web server Exporting configuration data “System, Configuration data, Export configuration” Figure 8-8 Menu “System, Configuration data, Export configuration” If you want to export the entire device configuration, all checkboxes except the network configuration are enabled. 108904_en_00 PHOENIX CONTACT 75 / 192 EMpro - multi-functional energy measuring devices for front panel installation To perform a 1:1 device exchange, or to download an identical device configuration, click “Select all”. All checkboxes in the overview are enabled. Another option is to perform a partial configuration by only enabling the required checkboxes. In this case, only the selected configuration is downloaded. Press the “Download” button to download the configuration. 8.2.2 Navigation on the web server Importing configuration data “System, Configuration data, Import configuration“ Figure 8-9 Menu: “System, Configuration data, Import configuration” If you want to load an existing configuration file onto the device, you can use the “Choose file” button to select it. Use the “Import” button to load the selected file onto the device. 76 / 192 PHOENIX CONTACT 108904_en_00 Configuration 8.2.3 Navigation on the web server “System, Configuration data, Transfer configuration” Figure 8-10 108904_en_00 Direct transfer of configuration data Menu: “System, Configuration data, Transfer configuration” PHOENIX CONTACT 77 / 192 EMpro - multi-functional energy measuring devices for front panel installation By directly transferring the configuration data, you prevent caching on a local computer. If you want to transfer the entire device configuration directly from one device to another, use the “Select all” button to enable all checkboxes in the overview. The network connection is not activated. If you want to include the network configuration, select it additionally. Observe the following: – You have to know the IP addresses and passwords of the devices. – All devices have to be accessible via the network. In addition to transferring the entire device configuration, you can also perform a partial transfer of the configuration by selecting the required checkboxes. Enter the device addresses and passwords into the respective fields. To check the connection to the entered device, click the “Check connection” button. Click the “Transfer” button to transfer the selected configuration data to the devices. 78 / 192 PHOENIX CONTACT 108904_en_00 Measuring technology 9 Measuring technology 9.1 Navigation on the web server Meter readings “Home, Meter readings” Figure 9-1 Menu: “Home, Meter readings” The device provides various meter readings for measuring the energy data. These are described in the following sections. 108904_en_00 PHOENIX CONTACT 79 / 192 EMpro - multi-functional energy measuring devices for front panel installation Navigation on the display 9.1.1 Energy meters 9.1.1.1 Energy meter, total “E, Energy total” Navigation on the display Energy total Figure 9-2 Menu: “E, Energy total” Figure 9-3 Menu: “E, Energy total” This energy meter is always counting. This energy meter cannot be reset. The following energy data is recorded: – Active energy: supply (Ea+), consumption (Ea-) – Reactive energy: supply (Er+), consumption (Er-) – Apparent energy (Es) 80 / 192 PHOENIX CONTACT 108904_en_00 Measuring technology 9.1.2 Navigation on the display Energy resettable “E, Energy resettable” Navigation on the display Figure 9-4 Menu: “E, Energy resettable” Figure 9-5 Menu: “E, Energy resettable” Energy resettable This energy meter is always counting. This energy meter can be reset. Reset The reset can be performed by means of the web server, the control buttons on the display, or the Modbus communication interface. The following energy data is recorded: – Active energy: supply (Ea+), consumption (Ea-) – Reactive energy: supply (Er+), consumption (Er-) – Apparent energy (Es) 108904_en_00 PHOENIX CONTACT 81 / 192 EMpro - multi-functional energy measuring devices for front panel installation 9.1.3 Navigation on the display Tariff meter “Tar, Tariff meter 1...4“ Figure 9-6 Menu: “Tar, Tariff meter 1...4” Figure 9-7 Menu: “Tar, Tariff meter 1” Tariff meter (1…4) If a tariff meter is selected/activated, counting is always performed on this meter. Tariff meters 1...4 can be reset. Reset The reset can be performed by means of the web server, the control buttons on the display, or the Modbus communication interface. The following energy data is recorded for each tariff meter: – Active energy: supply (Ea+), consumption (Ea-) – Reactive energy: supply (Er+), consumption (Er-) – Apparent energy (Es) 82 / 192 PHOENIX CONTACT 108904_en_00 Measuring technology 9.1.4 Navigation on the display Operating hours counter “Device info, Operating hours/Load operation” Figure 9-8 Menu: “Device info, Operating hours/Load operation” Figure 9-9 Menu: “Device info, Operating hours/Load operation” The device provides two different operating hour counters. Operating hours (T_tot) This counter keeps running as long as the device is supplied with voltage. Load operation (T_load) This counter is a load counter that starts running from a configurable power threshold (in W). The default setting for the power threshold is 100 W. The value can be configured via the Modbus communication interface. 108904_en_00 PHOENIX CONTACT 83 / 192 EMpro - multi-functional energy measuring devices for front panel installation 9.2 9.2.1 Statistics Average values The device makes it possible to determine average values based on the available measurement data. The average is generated for the following measurement values: – Voltages: phase to phase U12, U23, U31 – Voltages: phase to neutral conductor U1, U2, U3 – Frequency – Currents I1, I2, I3, IN – Active power: consumption, supply – Reactive power: consumption, supply – Apparent power The measurement values are divided into groups. These groups can be configured independently of each other. The following groups have been formed: – Voltages – Frequency – Currents – Power – Predictions For each average value, the minimum and maximum averages are always recorded and displayed. The data can be called up via the web server, the display and via the communication interface. There are three different types of average value generation: – AVG over fixed interval – AVG over rolling interval – AVG over sliding interval The average value types are described in the following sections. The figures show the three different types of average value calculation. Select a time interval that the measuring device will then use for calculating the average. 84 / 192 PHOENIX CONTACT 108904_en_00 Measuring technology Navigation on the web server “Settings, Average values” Figure 9-10 Status 108904_en_00 Menu: “Settings, Average values” Here, the current status of the average value generation is shown. PHOENIX CONTACT 85 / 192 EMpro - multi-functional energy measuring devices for front panel installation Figure 9-11 Settings 86 / 192 Menu: “Average values, Settings” Here, enter the configuration in hh:mm:ss for the average value generation. If the checkbox is enabled, the average values are synchronized via the digital input. PHOENIX CONTACT 108904_en_00 Measuring technology 9.2.1.1 Interval with fixed measuring interval length The intervals follow each other consecutively at the measurement interval length. The requirement is calculated and updated at the end of each interval. Figure 9-12 9.2.1.2 Interval with sliding measuring interval length AVG over fixed interval (fixed block) Sliding average value (sliding block) The intervals slide and have a set measuring interval length. The average value is generated and updated with the sliding speed. During each update, the average is generated for the last completed interval. Figure 9-13 108904_en_00 AVG over fixed interval (fixed block) Sliding average value (sliding block) PHOENIX CONTACT 87 / 192 EMpro - multi-functional energy measuring devices for front panel installation 9.2.1.3 Interval with rolling block There is a set interval and a subinterval. The subinterval has to be an integer factor of the interval. Example: If the selected interval is 15 minutes, three 5-minute subintervals have to be selected to match it. The average value is generated and updated at the end of each completed subinterval. Figure 9-14 88 / 192 PHOENIX CONTACT Rolling average value (rolling block) Rolling average value (rolling block) 108904_en_00 Measuring technology 9.2.1.4 Interval with fixed measuring interval length The intervals follow each other consecutively at the measurement interval length. All recorded individual values within the generated average values have the same valency. Figure 9-15 9.2.1.5 Interval with fixed measuring interval length Prediction calculation (equally weighted average) Prediction calculation (weighted average) The intervals follow each other consecutively at the measurement period length. The last acquired, individual value within the generated average values has the highest valency. As each new value is recorded, the valency of the individual values decreases (exponentially). Figure 9-16 108904_en_00 Trend calculation (equally weighted average) Prediction generation (weighted average) PHOENIX CONTACT 89 / 192 EMpro - multi-functional energy measuring devices for front panel installation 90 / 192 PHOENIX CONTACT 108904_en_00 Functions 10 Functions 10.1 Digital input The digital input complies with IEC 61131-2 Type 3. It includes the following functions: – Impulse counter – Tariff selection – Synchronization of average values – Acknowledgment of alarms 108904_en_00 PHOENIX CONTACT 91 / 192 EMpro - multi-functional energy measuring devices for front panel installation Figure 10-1 Digital input Status The “Status” area shows the current status of the digital input. Linked functions The digital input has been configured with a defined function. By clicking the respective link, you can access the configuration page for the function. Settings An identifier can be assigned to the digital input. With the checkbox, it can be activated or deactivated. In the default settings, the digital input is activated. 92 / 192 PHOENIX CONTACT 108904_en_00 Functions 10.1.1 Impulse counter The impulse counter counts the pulses generated by an external device. It is possible to assign a measuring unit (volume, weight, distance, electrical power or an own unit), as well as the valency. Navigation on the web server “Settings, Impulse counter” Figure 10-2 Menu: “Settings, Impulse counter” Status The “Status” area shows the current status of the digital input. Settings Set the impulse counter in accordance with your requirements. Activate The impulse counter can be activated/deactivated with the checkbox. Valency The impulse corresponds to the set value and is thus an additional multiplier. The valid value range is 1 … 65535. Unit Select a unit from the drop-down menu, or assign an own unit by selecting “Custom”. 108904_en_00 PHOENIX CONTACT 93 / 192 EMpro - multi-functional energy measuring devices for front panel installation Unit: You can select between the following units: – kWh – kVAh – kvarh – ml – l – m³ – g – kg – t – m – km – Custom You can use the “Custom” option to define an own unit. 94 / 192 PHOENIX CONTACT 108904_en_00 Functions 10.1.2 Tariff selection A switchover from one tariff to another can be performed via the digital input. Depending on the status of the input signal, tariff meter 1 or tariff meter 2 is used. Two of the four tariffs of the device can be used via the digital input. Via the web server, you can manually configure up to four tariffs (identifiers 1...4) and read them via the communication interface. Navigation on the web server “Settings, Tariffs” Figure 10-3 108904_en_00 Menu: “Settings, Tariffs, Digital input” PHOENIX CONTACT 95 / 192 EMpro - multi-functional energy measuring devices for front panel installation Status The “Status” area shows the current status of the digital input. Settings Set the impulse counter according to your requirements. Identifier Define the two identifiers (names) for your tariffs. Mode Specify the digital input as method for using the tariff selection. Digital input Define the status of the digital input in relation to the identifier. 96 / 192 PHOENIX CONTACT 108904_en_00 Functions 10.1.3 Synchronization of average values By means of the digital input, the synchronization pulse can be used for starting the respective average value generation. Navigation on the display 108904_en_00 “UL-L, UL-L ...” Figure 10-4 Menu: “UL-L” Figure 10-5 Menu: “UL-L, UL-L instantaneous” (instantaneous values, instantaneous) Figure 10-6 Menu: “UL-L, UL-L min” (minimum values, min) PHOENIX CONTACT 97 / 192 EMpro - multi-functional energy measuring devices for front panel installation 98 / 192 PHOENIX CONTACT Figure 10-7 Menu: “UL-L, UL-L max” (maximum values, Max) Figure 10-8 Menu: “UL-L, UL-L AVG min” (minimum average values, AVG Min) Figure 10-9 Menu: “UL-L, UL-L AVG” (average values, AVG) Figure 10-10 Menu: “UL-L, UL-L AVG max“ (maximum average values, AVG max) 108904_en_00 Functions Navigation on the web server “Settings, Average values” Figure 10-11 Menu: “Settings, Average values, Status” The digital input can be used to synchronize the average value generation. This function is used, e.g., when energy requirements have been defined that are not to be exceeded. When the average values are not synchronized, the measuring results might not correspond to the relevant energy requirements. 10.1.4 Acknowledgment of alarms In most applications, configured alarms that occur in the event of an error in the application are self-acknowledging. After the error status has been restored to the normal status (operation) of the applications, the alarm message disappears again. You can save an error status in the application until it is manually reset via the digital input. 108904_en_00 PHOENIX CONTACT 99 / 192 EMpro - multi-functional energy measuring devices for front panel installation 10.2 Digital output The digital output complies with IEC 61131-2 Type 3. It can be configured via the web server or the Modbus communication interface. Navigation on the web server “Settings, Digital output” Figure 10-12 Menu: “Settings, Digital output” Status The “Status” area shows the current status of the digital output. Identifier The identifier can be used to assign a user-specific designation to the digital output. Idle level There are two possible statuses for the idle level. 100 / 192 PHOENIX CONTACT 108904_en_00 Functions – – NC: Normally closed NO: Normally open The default setting for the digital output is NC (normally closed). Only one function can be configured at a time. – Impulse – Device status – Manual – Alarm – Rotary field direction – Deactivated The digital output is deactivated by default. 108904_en_00 PHOENIX CONTACT 101 / 192 EMpro - multi-functional energy measuring devices for front panel installation 10.2.1 Navigation on the web server Impulse “Settings, Digital output”, “Impulse” function Figure 10-13 102 / 192 PHOENIX CONTACT Menu: “Settings, Digital output”, “Impulse” function 108904_en_00 Functions With the “Impulse” function, the following electrical parameters can be transmitted to a higher-level evaluation unit: – Active energy (positive, negative) – Reactive energy (positive, negative) – Apparent energy Other configuration parameters are: Valency The impulse corresponds to the set value. The valid value range is 0.01 … 655.35 in kWh. Impulse duration 108904_en_00 The valid value range is 30 … 900 in ms. PHOENIX CONTACT 103 / 192 EMpro - multi-functional energy measuring devices for front panel installation 10.2.2 Device status The “Device status” function can be used to check whether the device is on or off. Here, it is also possible to define whether the output is normally closed (NC) or normally open (NO) in idle state. Navigation on the web server “Settings, Digital output”, “Device status” function Figure 10-14 104 / 192 PHOENIX CONTACT Menu: “Settings, Digital output”, “Device status” function 108904_en_00 Functions Status The “Status” area shows the current status of the digital output. Identifier The identifier can be used to assign a user-specific designation to the digital output. Idle level There are two possible statuses for the idle level. – NC: Normally closed – NO: Normally open The default setting for the digital output is NO. 108904_en_00 PHOENIX CONTACT 105 / 192 EMpro - multi-functional energy measuring devices for front panel installation 10.2.3 Manually With the “Manually” function, the digital output can be enabled and disabled via the Modbus communication interface. Here, you also have to define whether the output is normally closed (NC) or normally open (NO) in idle state. Navigation on the web server “Settings, Digital output”, “Manually” function Figure 10-15 Menu: “Settings, Digital output”, “Manually” function Status The “Status” area shows the current status of the digital output. Identifier The identifier can be used to assign a user-specific designation to the digital output. Idle level There are two possible statuses for the idle level. 106 / 192 PHOENIX CONTACT 108904_en_00 Functions – – NC: Normally closed NO: Normally open The default setting for the digital output is NO. 10.2.4 Alarm The “Alarm” function can be used to react to changes to the measurement values. You can define upper and lower thresholds for the domain. If the measured values are outside of these thresholds, the alarm function is activated and sent via the digital output. 108904_en_00 PHOENIX CONTACT 107 / 192 EMpro - multi-functional energy measuring devices for front panel installation Navigation on the web server Menu: “Settings, Digital output”, “Alarm” function Figure 10-16 108 / 192 PHOENIX CONTACT Menu: “Settings, Digital output”, “Alarm” function 108904_en_00 Functions Status The “Status” area shows the current status of the digital output. Identifier The identifier can be used to assign a user-specific designation to the digital output. Idle level There are two possible statuses for the idle level. – NC: Normally closed – NO: Normally open Function Select the “Alarm” function. Navigation on the web server “Settings, Alarm” Figure 10-17 Status 108904_en_00 Menu: “Settings, Alarm, Status” The “Status” area shows the current status of the alarms. PHOENIX CONTACT 109 / 192 EMpro - multi-functional energy measuring devices for front panel installation Settings Set the alarm according to your requirements. Figure 10-18 Menu: “Settings, Alarm” Confirm with digital input You can use the checkbox to define that manual acknowledgment of an alarm is required. The acknowledgment is performed via the digital input, which has to be configured for this purpose. Identifier) The identifier can be used to assign a user-specific designation to the alarms. Alarm 1…4 You can use the four tabs to define the alarm configuration for each alarm. Data source Select the measurement value to be monitored. High limit and low limit Use the checkbox to select the monitoring function. Depending on which function you selected, enter the value to be monitored. Delay Enter the tripping delay for the alarm in seconds. Hysteresis For the switching threshold, a hysteresis in percent is required. Enter it here. 110 / 192 PHOENIX CONTACT 108904_en_00 Functions Self-cleared With this checkbox, you can define that the alarm self-acknowledges after the normal status has been restored. This way, no manual acknowledgment via the digital input is required. The integrated logic gate enables multiple use of the digital output for the alarm function. 108904_en_00 PHOENIX CONTACT 111 / 192 EMpro - multi-functional energy measuring devices for front panel installation 10.2.5 Rotary field direction The recognition of the rotary field direction is used to inform the digital output about the state of the application. The rotary field direction can be configured for both directions (left, right). Navigation on the web server “Digital output, Settings, “Rotary field direction” function Figure 10-19 112 / 192 PHOENIX CONTACT Menu: “Digital output, Settings, “Rotary field direction” 108904_en_00 Functions Status The “Status” area shows the current status of the alarms. Settings Set the alarm according to your requirements. Identifier The identifier can be used to assign a user-specific designation to the function. Idle level There are two possible statuses for the idle level. – NC: Normally closed – NO: Normally open The default setting for the digital output is NO. Function Select the “Rotary field direction” function from the drop-down menu. Rotary field direction Select the appropriate rotary field direction. 108904_en_00 PHOENIX CONTACT 113 / 192 EMpro - multi-functional energy measuring devices for front panel installation 10.2.6 Deactivating the digital output The digital output can be deactivated, so that no function is assigned to it. Navigation on the web server “Digital output, Settings“, “Deactivated” function Figure 10-20 Menu: “Digital output, Settings“, “Deactivated” function Status The “Status” area shows the current status of the digital output. Settings Set the digital output according to your requirements. Identifier The identifier can be used to assign a user-specific designation to the function. 114 / 192 PHOENIX CONTACT 108904_en_00 Functions Idle level There are two possible statuses for the idle level. – NC: Normally closed – NO: Normally open The default setting for the digital output is NO. Function 108904_en_00 Select the “Deactivated” function from the drop-down menu. PHOENIX CONTACT 115 / 192 EMpro - multi-functional energy measuring devices for front panel installation 10.3 Navigation on the display Tariff selection “Tar, Tariff meter 1...4“ Figure 10-21 Menu: “Tar, Tariff meter” Figure 10-22 Menu: “Tar, Tariff meter 1” The device offers various options for selecting between up to four tariffs. The following procedures are possible: – Using the digital input: 2 tariffs can be used – Using manual switching via a communication interface: 4 tariffs can be used – Using a time schedule: 4 tariffs can be used 116 / 192 PHOENIX CONTACT 108904_en_00 Functions 10.3.1 Tariff selection via the communication interface The individual tariffs can also be selected via the Modbus communication interface. With the addresses in the register tables, a user-specific usage of all tariff meters can be defined, which is configured completely by means of the controller. Navigation on the web server “Tariffs, Settings” Figure 10-23 Menu: “Tariffs, Settings” Status The “Status” area shows the current status of the tariff function. Settings Configure the tariff selection according to your requirements. Identifier Define the identifiers for your tariffs. Mode Set the mode to “Manually”. Tariff meter Select the desired tariff from the drop-down menu. 108904_en_00 PHOENIX CONTACT 117 / 192 EMpro - multi-functional energy measuring devices for front panel installation 10.3.2 Tariff selection using a time schedule The individual tariffs can also be selected by using time control. A custom application can be configured using a configurable time. The switchover to the respective tariff meter thus purely depends on the time. 118 / 192 PHOENIX CONTACT 108904_en_00 Functions Navigation on the web server “Tariffs, Settings” Figure 10-24 Menu: “Tariffs, Settings” Status The “Status” area shows the current status of the tariff function. Settings Configure the tariff selection according to your requirements. Identifier Define the identifiers for your tariffs. Mode Set the mode to “Time controlled”. 108904_en_00 PHOENIX CONTACT 119 / 192 EMpro - multi-functional energy measuring devices for front panel installation Tariff meter Select the desired tariff from the drop-down menu. Depending on the number of tariffs, you can configure the individual tabs for the tariffs. Days Use the checkboxes to select the days of the week. From/Until Enter the times for using the tariffs as appropriate for your application. In the appendix, the configured weekdays and times are shown. 120 / 192 PHOENIX CONTACT 108904_en_00 Functions 10.4 Logic gate The integrated logic gate makes it possible to define several alarm messages for the alarm function of the digital output. The digital output can be used for this type of multiple assignment, depending on up to four alarms/thresholds. Navigation on the web server 108904_en_00 “Digital output, Settings”, “Alarm” function PHOENIX CONTACT 121 / 192 EMpro - multi-functional energy measuring devices for front panel installation Figure 10-25 122 / 192 PHOENIX CONTACT Menu: “Settings, Digital output”, “Alarm” function 108904_en_00 Functions Alarm 1…4: Select the alarms that are to be linked to the logic gate. You can use the checkbox to invert the signal. Logic gate An operator has to be defined for the function of the logic gate. Select a logic operator from the drop-down menu: – AND – OR – XOR – NAND – NOR – NXOR The alarms themselves are configured via “Settings, Alarms”. Function description of the logic gate The logic gate links configured statuses of the respective alarms with an assigned logic function. Various application-specific statuses can be monitored, depending on how the connections are combined. Below, you can find explanations on how the logic operators work: AND operator Figure 10-26 Logic gate with AND operator When all alarms are active at the same time, this signal output is set. If one of the alarms is no longer active, this signal output is reset. NAND operator Figure 10-27 Logic gate with NAND operator When none of the alarms are active, this signal output is set. 108904_en_00 PHOENIX CONTACT 123 / 192 EMpro - multi-functional energy measuring devices for front panel installation If one of the alarms is active, this signal output is reset. OR operator Figure 10-28 Logic gate with OR operator When one of the alarms is active, the signal output is set. If none of the alarms are active, this signal output is reset. NOR operator Figure 10-29 Logic gate with NOR operator When none of the alarms are active, this signal output is set. If one of the alarms is active, this signal output is reset. XOR operator Figure 10-30 Logic gate with XOR operator If an alarm is active, this signal output is set. If none or several of the alarms are active, this signal output is reset. 124 / 192 PHOENIX CONTACT 108904_en_00 Functions NXOR operator Figure 10-31 Logic gate with NXOR operator If none or several of the alarms are active, this signal output is set. If only one of the alarms is active, this signal output is reset. 108904_en_00 PHOENIX CONTACT 125 / 192 EMpro - multi-functional energy measuring devices for front panel installation 10.5 Data logging Figure 10-32 Status 126 / 192 Menu: “Logging” The “Status” area shows an overview of the current logging data. PHOENIX CONTACT 108904_en_00 Functions Figure 10-33 “Menu: Logging, Settings” Log 1...8 Here, you can configure up to eight different logging parameters. Data source Select the desired electrical parameter for the logging from the drop-down menu. Interval Enter the interval time in minutes. The shortest duration that can be set is 1 minute. The maximum logging duration depends on the configured interval. For an interval of 15 minutes, the logging capacity is approx. 90 days. If you shorten the interval, the logging capacity is also reduced (e.g., 10 minute interval/60 days logging capacity). Circular buffer Activate the circular buffer if you want to use the FIFO principle (first-in/first-out) for the data logging. Deactivate the circular buffer if you want to define a fixed starting point. The logging automatically stops once the memory is full. 108904_en_00 PHOENIX CONTACT 127 / 192 EMpro - multi-functional energy measuring devices for front panel installation Figure 10-34 Menu: “Logging, Saved data” You can view all configured logging data as a chart in the web server. To do so, select the desired logging data from the drop-down menu. With your mouse, you can zoom in on the saved data. By means of the selection box to the right next to the chart, you can also export the logging data as CSV, XLS or PDF file. 128 / 192 PHOENIX CONTACT 108904_en_00 Functions 10.6 Firmware update The device provides a function for updating the firmware. New versions can contain bug fixes, optimize the performance and expand the functionality. Update files are provided by Phoenix Contact GmbH & Co. KG. The respective update containers can be downloaded from the product-specific pages at phoenixcontact.com. 10.6.1 Execution Figure 10-35 Firmware update Execution of a firmware update In this area, you can load a new firmware update onto the device. To perform the update, you need administrator rights. An update can only be performed via the web server of the device. File 108904_en_00 Upload the new firmware file. Click the “Upload” button to begin the process. PHOENIX CONTACT 129 / 192 EMpro - multi-functional energy measuring devices for front panel installation Figure 10-36 Progress and state Progress and state Once the firmware file has been uploaded, you can start the update on the device by clicking “Perform update”. Observe the following when performing a firmware update: – The update process can take several minutes and should not be interrupted. – Do not exit the subpage for updating the firmware of the web-based management. – During the update process, the device restarts and is thus unavailable for a certain period of time. – During certain steps of the update process, it is possible that the energy meters of the system are stopped. 130 / 192 PHOENIX CONTACT 108904_en_00 Functions 10.6.2 Security Executing a firmware update requires read access to the system. Since execution is only possible via the web server, the access is password-protected. The update file is protected against manipulation. The system detects and rejects manipulated update files. The update process is safeguarded against unintentional interruption or failure. An executable firmware version is always retained on the system. 108904_en_00 PHOENIX CONTACT 131 / 192 EMpro - multi-functional energy measuring devices for front panel installation 132 / 192 PHOENIX CONTACT 108904_en_00 Communication 11 Communication All devices are equipped with an Ethernet interface with an RJ45 socket. Other communication interfaces can also be available optionally. – RS-485 – PROFINET – EtherNet/IP™ 11.1 Ethernet All device versions are Ethernet-capable via an RJ45 interface. The devices support 10/100 Mbit full/half duplex. It is recommended to use at least Cat.5 cables (EIA/TIA-568) for installation. 11.1.1 IP addressing The EMpro devices can be assigned both a static and a dynamic IP configuration. Current devices support IPv4. In the delivery state, the devices use a static IP configuration with the following parameters: Table 11-1 IP address 192.168.1.2 Subnet mask 255.255.255.0 Default gateway 0.0.0.0 DNS server 0.0.0.0 The entry IP 0.0.0.0, e.g., for the default gateway, indicates that no default gateway has been configured. When the dynamic IP assignment is used, the device receives its IP configuration via the DHCP protocol from another DHCP server in the same network. 108904_en_00 PHOENIX CONTACT 133 / 192 EMpro - multi-functional energy measuring devices for front panel installation 11.1.2 Configuration of the communication interface You can adapt the following parameters of the network interface: Table 11-2 Adaptable parameters of the network interface Function Information Web server Display Register Mode The mode is used to define whether a static IP configuration from the device memory has to be used, or a dynamic configuration should be performed via DHCP instead. x x x IP address This setting is only used in static mode. Here, the static IP address of the device is configured. In dynamic mode, this parameter is supplied by the DHCP server. x x x Subnet mask This setting is only used in static mode. Here, the static subnet mask of the device is configured. In dynamic mode, this parameter is supplied by the DHCP server. x x x Default gateway This setting is only used in static mode. Here, the static IP address of the default gateway to be used is configured. In dynamic mode, this parameter is supplied by the DHCP server. The default gateway is required to allow communication across network boundaries. This is defined by means of the subnet mask. x x x DNS server This setting is only used in static mode.Here, the static IP address of the DNS server to be used is configured. In dynamic mode, this parameter is supplied by the DHCP server. The DNS server is used to perform name resolutions, e.g., for an NTP time server. x x x Device name The device supports the NetBios name service. With this protocol, the device can be addressed using a host name, without knowing the IP address of the device. The device has three NetBios names. Two of these names are manufacturer-specific and cannot be modified. You can change the third name. The following names have been defined: x x (read only) x First manufacturer-specific NetBios name: (e.g., EEM-MA770) Second manufacturer-specific NetBios name: eem (e.g., eem1234567890) User-specific NetBios name: (default: ) 134 / 192 PHOENIX CONTACT 108904_en_00 Communication 11.1.3 Status of the communication interface If the network interface is ready, this is indicated by the icon on the display. The following conditions must be met for the network interface to be ready: – Device start completed – Network link established – IP configuration valid – Always true for static configurations – True for dynamic configurations after the IP configuration has been received by the DHCP server The current status of the network interface can be viewed via the WBM, the display and Modbus. There are two LEDs on the RJ45 socket: – Green LED for link status, to the left of the RJ45 connector – Green LED for sending activity, to the right of the RJ45 connector 11.1.4 Security The users are responsible for securing their networks against unauthorized access. Up to four clients can access the interface simultaneously. 11.2 11.2.1 Modbus Function The Modbus protocol defines both a protocol on the application layer and a transmission protocol. The application layer protocol is identical for all interface versions. The differences between Modbus/TCP and Modbus/RTU lie in the transmission protocol. On the application layer, Modbus supplies a 16-bit address space that can be used to address 16-bit registers. Using various function codes, read and write operations can be performed on registers. For detailed information about the Modbus specification refer to www.modbus.org/. The EMpro supports the following function codes: – 03 (0x03) Read holding registers – 04 (0x04) Read input registers – 06 (0x06) Write single register – 16 (0x10) Write multiple registers Here, it has to be noted that the device does not differentiate between holding and input registers. Both function codes return the same registers. 108904_en_00 PHOENIX CONTACT 135 / 192 EMpro - multi-functional energy measuring devices for front panel installation 11.2.2 Modbus/RTU In the case of Modbus/RTU, the Modbus application layer protocol is supplemented with additional information and physically sent via an RS-485 interface. The start and end of a Modbus message is coordinated by means of timings. Modbus/RTU describes a master/slave protocol. Here, the EMpro acts as Modbus/RTU slave. An exception here is the gateway mode. The additional information consists of a byte for addressing the device. Valid device addresses are in the range from 1-247. The default setting for the devices is address 1. Address 0 is reserved for broadcast messages in the network and cannot be assigned as an address to a device. According to the specification, addresses 248-255 are reserved and cannot be assigned to the device either. A cyclic redundancy check (CRC) is attached to the Modbus message as additional information. The CRC is used to detect transmission errors. The calculation and the polynomial used are documented in the Modbus specification. The Modbus/RTU protocol is supported by all EMpro versions with an RS-485 interface. 11.2.2.1 Topology The smallest network via RS-485 (Modbus) that makes sense consists of two devices: – 1 x master 1 x slave The typical limit is 32 devices. – 1 x master 31 x slaves The largest network via RS-485 (Modbus) that makes sense consists of 248 devices, because of the addressing: – 1 x master 247 x slaves Figure 11-1 136 / 192 PHOENIX CONTACT Topology 108904_en_00 Communication 11.2.2.2 Using connections and designations Internal GND BΩ A+ Ω Figure 11-2 Connections and designations The RS-485 interface has four assigned terminals. GND: Shield of signal line B- and A+: Signal lines Ω: 120 Ω resistor The non-inverted signal can have the following designations: A, +, A+, TxD+/RxD+, D+ The inverted signal can have the following designations: B, -, B-, TxD-/RxD-, D- To ensure that the communication is guaranteed even in the event of malfunctions, ensure that the following conditions are met in the RS-485 network: – Twisted pair conductors (A and B) (stranding) – Shielded conductors (GND) – Termination resistors (and a bias network) NOTE: If you want to activate the integrated 120 Ω resistor, bridge the terminals Ω and A+. 108904_en_00 PHOENIX CONTACT 137 / 192 EMpro - multi-functional energy measuring devices for front panel installation 11.2.2.3 Figure 11-3 Status 138 / 192 Parameters for using Modbus via RS-485 Modbus status The “Status” area gives an overview of the current Modbus configuration. PHOENIX CONTACT 108904_en_00 Communication Figure 11-4 Modbus settings Please observe the following: – Each slave is assigned an address between 1 and 247. – Each address is used only once. – There is only one master per RS-485 network. – All devices use the same parameters for the baud rate, stop bits and parity. You can configure the following parameters that are supported by the RS-485 interface: – Baud rates: 2400, 4800, 9600, 19200, 38400, 57600 and 115200 bps – Stop bits: 1, 2 – Parity: even, odd, none The parameters can also be set via Modbus/TCP. 108904_en_00 PHOENIX CONTACT 139 / 192 EMpro - multi-functional energy measuring devices for front panel installation 11.2.3 Modbus/TCP In the case of Modbus/TCP, a special header (Modbus Application Header [MBAP]) is prefixed to the Modbus message. This Modbus/TCP message is then transmitted via an IPbased network in a TCP frame. The EMpro acts as Modbus/TCP server and opens port 502 for communication with any Modbus/TCP clients. This port cannot be configured by the user. Since TCP is a connection-oriented protocol, a client first has to establish a TCP connection with the EMpro to exchange data via Modbus/TCP. The number of Modbus/TCP connections that can be open in parallel on each version of the EMpro product family is limited to four. If there are already four open Modbus/TCP connections on the EMpro, additional connection queries on port 502 are rejected. Additionally, to enable Modbus/TCP communication, the user has to make sure that this port is enabled in the network. The MBAP contains a field that is declared as unit identifier in the specification. This unit identifier is comparable with the device address of Modbus/RTU. However, it is not relevant for the EMpro in the case of Modbus/TCP and is ignored by the device since through its IP address the device already has a unique address in a network . An exception applies if the device is operated in gateway mode (see Section “Modbus gateway” on page 140). The Modbus TCP specification recommends using 255 as unit identifier for queries. All EMpro versions support the Modbus TCP protocol. 11.2.4 Modbus gateway EMpro versions with an RS-485 interface can optionally be operated in gateway mode. By default upon delivery, the gateway mode is not active. In this case, the device acts as Modbus TCP server on the Ethernet interface and as Modbus/RTU slave on the RS-485 interface. When the gateway function is activated, the device behaves as Modbus gateway on the Ethernet interface and, in parallel, continues to operate as Modbus TCP server (can be reached via unit identifier == 255). On the RS-485 interface, the device now acts as Modbus/RTU master. As master, the EMpro can now independently send queries in the network (note: there must be no other master in the system). As Modbus gateway, the device converts an incoming Modbus TCP message (that does not have the unit identifier 255 in the MBAP header) into a Modbus RTU message and forwards it to the appropriate receiver in the Modbus RTU network. On the TCP side, the unit identifier is used for addressing the Modbus RTU receiver. In turn, the response is converted from Modbus/RTU format back to Modbus/TCP format and is sent to the querying client as Modbus/TCP response. Broadcast messages in gateway mode The Modbus specification does not describe the behavior of a gateway device when the unit identifier in the MBAP header has a value of 0. In the Modbus/RTU network, this value represents a broadcast message. There are different interpretations of the behavior of a gateway in this case. 140 / 192 PHOENIX CONTACT 108904_en_00 Communication The following questions regarding the behavior of a gateway remain open: – Forwarding the broadcast in the RTU network. Since there is no broadcast in the case of Modbus/TCP, it is not defined whether or not the MBAP address 0 is forwarded in the RTU network by the Modbus gateway. – Response messages with the unit identifier 0. Neither is there a definition on whether the gateway itself generates an answer to messages with a unit identifier of 0. By default upon delivery, devices of the EMpro product family behave as follows: The EMpro does not forward messages with unit identifier 0 to the RTU network as broadcast. Furthermore, the EMpro itself responds to the query as Modbus TCP server. Timing in gateway mode As gateway, the EMpro acts as Modbus master on the Modbus/RTU side and forwards queries to the addressed slaves. As Modbus/RTU master, the device requires a time-out for queries. If this time-out has expired without a response from the Modbus/RTU slave, the gateway replies to the Modbus/TCP client with an error message. By default upon delivery, the duration for the time-out is 250 ms. Unsuitable time-out settings both at the gateway and and at the querying Modbus/TCP client can cause unwanted problems. Problems can occur if the time-out times at the Modbus/TCP client or EMpro in gateway mode are too short, or if the ratios between these two time-out times are unfavorable. The time-out setting has to be individually configured based on the application. Nevertheless, the following recommendations can be given; they should work in normal cases. – The default setting of the EMpro is adequate for most applications. – If there are slaves with slow response times in the RTU network, the time-out setting of the gateway should be increased. – If very slow Baud rates are used on the RS-485, the time-out setting of the gateway should be increased. – The time-out duration of the querying Modbus/TCP client should always be longer than that of the gateway. 108904_en_00 PHOENIX CONTACT 141 / 192 EMpro - multi-functional energy measuring devices for front panel installation 11.3 PROFINET 11.3.1 1. 2. Software Check whether the firmware of your energy measuring device is up to date with the firmware available on the Phoenix Contact homepage. If the firmware is not up to date, download the current firmware from the specific product site at phoenixcontact.com (see Section “Firmware update” on page 129). Download the current GSDML file for your energy measuring device from the Phoenix Contact website. Additional requirements: – Pertinent knowledge of the preferred PROFINET engineering system – Executable project with configured controller 11.3.2 1. Preparing the GSDML file Unpack the ZIP file on your file system. 11.3.3 Integrating the GSDML file Integrate the GSDML file into your existing engineering system. An example of the integration is shown below, using the TIA portal V15. 1. Select “Options, Manage general station description files (GSD)”. Figure 11-5 142 / 192 PHOENIX CONTACT “Options, Manage general station description files (GSD)” 108904_en_00 Communication 2. 3. 4. Select the file that you want to install. Checkmark the file that you want to install. Click on “Install”. Figure 11-6 108904_en_00 Installing the station description file PHOENIX CONTACT 143 / 192 EMpro - multi-functional energy measuring devices for front panel installation The dialog shows that installation has been successful. 5. Close the window by clicking “Close”. Figure 11-7 144 / 192 PHOENIX CONTACT Dialog: “Manage general station description files” 108904_en_00 Communication 11.3.4 1. Create a project with any PROFINET-capable controller. Figure 11-8 108904_en_00 Integrating hardware “Devices & networks” in the network view PHOENIX CONTACT 145 / 192 EMpro - multi-functional energy measuring devices for front panel installation 2. Select “Devices & networks, Network view, Hardware catalog, Other field devices, PROFINET IO , Sensors, Phoenix Contact, EMpro“ and select your installed EMpro (e.g., EMM-MB371-PN). Figure 11-9 146 / 192 PHOENIX CONTACT Selecting the EMpro from the hardware catalog 108904_en_00 Communication 3. Drag and drop the EMpro from the hardware catalog to the network view. Figure 11-10 108904_en_00 Adding the EMpro to network view PHOENIX CONTACT 147 / 192 EMpro - multi-functional energy measuring devices for front panel installation The EMpro appears in the network view. Figure 11-11 148 / 192 PHOENIX CONTACT EMpro in the network view 108904_en_00 Communication 4. 5. Right-click on the EMpro in the network view. Select “Assign to a new IO controller”. Figure 11-12 6. 7. Assigning an I/O controller to the EMpro Select the desired network interface. Confirm with “OK”. Figure 11-13 Selecting the I/O controller The assignment has now been set up. 108904_en_00 PHOENIX CONTACT 149 / 192 EMpro - multi-functional energy measuring devices for front panel installation Figure 11-14 150 / 192 PHOENIX CONTACT Networking controller and energy measuring device 108904_en_00 Communication 11.3.5 1. 2. 3. Integrating modules and submodules In the structure tree, switch to the “Device configuration” view. In the hardware catalog, mark the desired module. Drag and drop it to the device overview. Figure 11-15 108904_en_00 Adding a module to the device overview PHOENIX CONTACT 151 / 192 EMpro - multi-functional energy measuring devices for front panel installation Subsequently, the associated submodules appear in the catalog. Figure 11-16 152 / 192 PHOENIX CONTACT Submodules in the hardware catalog 108904_en_00 Communication 4. 5. Select the desired submodules. Add the submodules under the respective main module using drag-and-drop. Figure 11-17 108904_en_00 Inserting submodules PHOENIX CONTACT 153 / 192 EMpro - multi-functional energy measuring devices for front panel installation The device overview shows the available modules and submodules. Figure 11-18 154 / 192 PHOENIX CONTACT Available modules and submodules 108904_en_00 Communication 6. Select a configured submodule in the device overview. If you are a Siemens user, refer to the register table for the respective energy measuring device for descriptions of the individual process data, which can be downloaded at phoenixcontact.net/products . Figure 11-19 108904_en_00 Selecting a submodule in the device overview PHOENIX CONTACT 155 / 192 EMpro - multi-functional energy measuring devices for front panel installation 11.3.6 1. 2. Linking process data Create PLC variables with unique designations. Connect these with the I/O variables. Figure 11-20 156 / 192 PHOENIX CONTACT Creating PLC variables and connecting them with I/O variables 108904_en_00 Communication 11.3.7 1. 2. Assigning a device name Right-click on the device to which you want to assign a name. Select “Assign device name”. Figure 11-21 108904_en_00 “Assign device name” PHOENIX CONTACT 157 / 192 EMpro - multi-functional energy measuring devices for front panel installation 3. Click “Update list”. Figure 11-22 158 / 192 PHOENIX CONTACT “Update list” 108904_en_00 Communication 4. 5. Select the device from the table. Click “Assign name”. Figure 11-23 108904_en_00 “Assign name” PHOENIX CONTACT 159 / 192 EMpro - multi-functional energy measuring devices for front panel installation The device name has been assigned successfully. Figure 11-24 160 / 192 PHOENIX CONTACT Assigning a PROFINET device name 108904_en_00 Communication Figure 11-25 108904_en_00 Assigning a PROFINET device name PHOENIX CONTACT 161 / 192 EMpro - multi-functional energy measuring devices for front panel installation 11.3.8 Function check You can perform a function check by creating a monitoring table for viewing the online values. 1. Compile the project. 2. Load it onto your controller. 3. Connect to the controller. 4. To perform a function check, switch to online mode and activate the monitoring by clicking on the glasses icon. Figure 11-26 162 / 192 PHOENIX CONTACT Monitoring table 108904_en_00 Communication 11.4 Configuration 11.4.1 Modbus/RTU Table 11-3 Function Information Activation of Modbus/RTU The Modbus/RTU protocol is activated by default, but can be deactivated by the user. x x x Modbus address The default setting is address 1. x x x Baud rate The default setting for the RS485 interface is 19200 bps. x x x Stop bits The default setting for the RS485 interface is 1 stop bit. x x x Parity The default setting for the RS485 interface is even parity. x x x 11.4.2 108904_en_00 Register Modbus/TCP Table 11-4 Modbus/TCP Function Information Activation of Modbus/TCP The Modbus/TCP protocol is activated by default, but can be deactivated by the user. 11.4.3 Web server Display Web server x Display Register x x Modbus gateway Table 11-5 Modbus gateway Function Information Activation of the gateway mode By default, the gateway mode is deactivated. Modbus gateway time-out The default setting is 250 ms. Web server x Display Register x PHOENIX CONTACT x 163 / 192 EMpro - multi-functional energy measuring devices for front panel installation 11.5 Security On most registers, write commands are PIN-protected. To change register values, the correct PIN is required. The PIN corresponds to the display PIN. The PIN can be changed by the user. To prevent unauthorized write access to the device, change the default PIN during initial commissioning of the device. Table 11-6 164 / 192 PHOENIX CONTACT PIN Function Information PIN change The default PIN is 0100. Web server Display x Register x 108904_en_00 Communication 11.6 Data types and registers The Modbus specifications does not include requirements on how various data types are to be displayed on the respective register. The specification only defines that the register has to be represented as “big endian”. This means that the high byte of a register is sent first, followed by the low byte. 8-bit integer types: Example: Value = 1 (0x01) Table 11-7 8-bit integer types Register address Register contents (hex) n 0x0001 16-bit integer types: Example: Value = 4660 (0x1234) Table 11-8 16-bit integer types Register address Register contents (hex) n 0x1234 32-bit integer types: Example: Value = 305419896 (0x12345678) Table 11-9 32-bit integer types Register address Register contents (hex) n 0x5678 n +1 0x1234 32-bit IEE 754 floating point: Example: Value = 123.456 (0x42F6E979) Table 11-10 108904_en_00 32-bit IEE 754 floating point Register address Register contents (hex) n 0xE979 n +1 0x42F6 PHOENIX CONTACT 165 / 192 EMpro - multi-functional energy measuring devices for front panel installation ASCII strings: Example: Value = EEM-MA (0x45, 0x45, 0x4D, 0x2D, 0x4D, 0x41, 0x33, 0x37, 0x30 -> ASCII coded) Table 11-11 166 / 192 PHOENIX CONTACT ASCII strings Register address Register contents (hex) n 0x4545 n +1 0x2D4D n +2 0x414D n +3 0x3733 n +4 0x0030 108904_en_00 Communication 11.7 Register table The register table is available for download from the Phoenix Contact website. 1. Open phoenixcontact.net/products. 2. Enter the order number of your energy measuring device into the search field. 3. In the download area of the product, you will find the register table under “Miscellaneous”. 11.8 Contents of the register table The register table contains information that concerns the contents and functions of the communication interfaces. The register table encompasses the entire Modbus register. To get the PROFINET-specific register, filter the empty cells from the “GSDML Module Name” column, so that only cells that are filled with content remain. 11.9 Description of the register table Figure 11-27 Register table Content of the line (CH) The first line of the register table contains information about the content of the respective line or column. H1 … Hn: Heading An “H” with a number indicates a heading. The number behind it indicates the hierarchical level. To keep the register entries structured and readable, they are divided by headings. 108904_en_00 PHOENIX CONTACT 167 / 192 EMpro - multi-functional energy measuring devices for front panel installation R: Register The “R” stands for Register and designates the lines that each describe a register. Only lines that also contain registers are relevant for automatic processing of the register table. U: Unused The “U” describes unused entries. These can be, e.g., address ranges that do not have a function (yet) and are reserved. E: End The “E” describes the end of the table. Dec: Decimal address The second column of the register table contains register addresses in decimal form. Hex: Hexadecimal address The third column of the register table contains register addresses in hexadecimal form. Count The “Count” column displays the number of registers required for the function described in this line. The required number is directly dependent on the data type. Short designation The “Short designation” column contains the abbreviated designations of the registers. The short designations are unique, so that all other data can be referenced using the short designations. Unit The unit for the process values is given in the “Unit” column. For example, the unit for the voltages is volt [V]. Divider The “Divider” column states the divider by which the value is to be divided to get the correct value. This is necessary, e.g., if the data type is an integer value, but a decimal fraction has to be entered. Example: If the harmonics are specified as percentage with signed integer, but have to be output with a precision of a tenth of a percent. In this case, for example, 15.2% is used as 152 with divider 10. R/W: Read/write access This column specifies which access is permitted for the respective register. R: Read only These registers can only be read. Attempting write access to these registers causes an error. 168 / 192 PHOENIX CONTACT 108904_en_00 Communication R/W: Read and write It is possible to both read and write to these registers. W: Write only These registers can only be written. Attempting read access to these registers causes an error. W/R0: Write only and read 0 These registers can only be written. Read access to these registers results in a zero as response. Datatype This column contains the data type to be used for decoding the contents of each respective register. ASCII Each register (16 Bit) contains two ASCII characters. When the number is entered, the number of individual registers contained in the character string is determined. Example: Dez:1234567 Hex: 0X31, 0X32, 0X33, 0X34, 0X35, 0X36, 0X37 Zero-terminated: “12345670” Hex: 0X31, 0X32, 0X33, 0X34, 0X35, 0X36, 0X37, 0X00 Number of registers = 4: Hex: 0X3231, 0X3433, 0X3534, 0X0037 Bit mask Each bit (bit 15-bit 0) of the register (16 bit) is evaluated individually. Example: “Resetting the tariff meter” Bit 0: Reset tariff 1 Bit 1: Reset tariff 2 Bit 2: Reset tariff 3 Bit 3: Reset tariff 4 An individual tariff meter, or any combination of meters from all tariff meters can be reset. Bool This data type makes a logical statement. 0: false 1: true Fl32 IEEE-754-single number 1.8.23 (32 bits, two 16-bit registers): 1 sign bit: positive and negative 108904_en_00 PHOENIX CONTACT 169 / 192 EMpro - multi-functional energy measuring devices for front panel installation 8 exponent bits:≈ value range of 38 decimal places 23 mantissa bits ≈ precision of 6 decimal places Decimal value range: ±1.175·10-38 to 3.40282·10+38 Register in float 32-bit value from the registers: 0X41340000 = 01000001 00110100 00000000 00000000b Bit31 = 0: SB, sign bit. This number is positive. Bit30 - Bit23: E, exponent. In this case: 130. Bit22 - Bit0: M, mantissa. Here it is 3,407,872. Z = 11.25 Float in register Floating-point number X = 11.25 SB, sign bit. This number is positive => Bit31 = 0 / 0X00 / 0b In this case 130 => Bit30 - Bit23 = 130 / 0X82 / 10000010b mantissa. Here it is 3,407,872 => Bit22 - Bit0 = 3407872 / 0x340000 / 0110100 00000000 00000000b 32-bit value for the register: 0X41340000 = 01000001 00110100 00000000 00000000b SInt16 Signed integer: 2 byte, 16 bit Value range: -215 … 215-1 -32,768 … 32,767 UInt16 Unsigned integer: 2 byte, 16 bit Value range: 0 … 216-1 0 … 65,535 UInt32 Unsigned integer: 4 byte, 32 bit Value range: 0 … 232-1 0 … 4294967295 SInt32 Signed integer: 4 byte, 32 bit Value range: -231 … 231-1 -2,147,483,648 … 2,147,483,647 170 / 192 PHOENIX CONTACT 108904_en_00 Communication UInt8 Only the low byte of the register is evaluated. 1 byte, 8 bit Value range: 0 … 28-1 = 0 … 255 UInt[] Array of UInt8 values. Their order follows that of the ASCII registers. These data types are used, e.g., for the MAC addresses. Three registers are required for the six bytes. E.g., 00:A00:45:66:4F:41 Name Here, the name of the respective register is entered. It may be longer than the short designation, so that it is readable and expresses the function of the register. Description In this column, the function of the register is described in detail. 108904_en_00 PHOENIX CONTACT 171 / 192 EMpro - multi-functional energy measuring devices for front panel installation 172 / 192 PHOENIX CONTACT 108904_en_00 Technical data 12 Technical data Technical data General data Measuring principle True r.m.s. value measurement (TRMS) up to 63rd harmonic Measurement value AC sine Nominal frequency 50/60 Hz Frequency range 45 ... 65 Hz Sampling rate 256 times the signal frequency: 12800 Hz @ FSignal = 50 Hz 15360 Hz @ FSignal = 60 Hz Degree of protection IP 54 (display with seal) IP20 (housing) Dimensions Width/height/depth EEM-MA77x 96 mm x 96 mm x 73.25 mm EEM-MA77x(-R) 96 mm x 96 mm x 73.25 mm EEM-MA77x(-PN, -EIP): Without PN-/EIP socket 96 mm x 96 mm x 81.25 mm With PN-/EIP socket 96 mm x 96 mm x 89.8 mm Installation depth EEM-MA77x: 58.25 mm EEM-MA77x(-R): 61.6 mm EEM-MA77x(-PN, -EIP): 66.25 mm - to the housing edge 74.8 mm - to the plug edge (PN/EIP) Plugs that are plugged in from behind are not considered in these specifications Voltage measurement Input measuring range, direct 18 V AC ... 690 V AC (Ph/Ph) 11 V AC ... 400 V AC (Ph/N) Input measuring range using transformer Primary 60 V AC ... 2,000,000 V AC Secondary 60 V AC ... 400 V AC Power consumption
2908301 价格&库存

很抱歉,暂时无法提供与“2908301”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2908301
  •  国内价格 香港价格
  • 1+5780.430301+717.05970
  • 10+5459.2749510+677.22052

库存:1