2908670

2908670

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    Soft Starter 9A 120VAC 480VAC 5HP 50Hz/60Hz DIN Rail

  • 数据手册
  • 价格&库存
2908670 数据手册
https://www.phoenixcontact.com/us/products/2908670 Hybrid motor starter - ELR H5-IES-PT/500AC-9-IOL - 2908670 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and Push-in connection. Connection to IO-Link. Key Commercial Data Packing unit 1 GTIN GTIN 4055626321257 Custom tariff number 85371098 Technical data Device supply Rated control circuit supply voltage US 24 V DC Control supply voltage range 19.2 V DC ... 30 V DC Rated control supply current IS 65 mA Type of protection Surge protection Reverse polarity protection Input data Input name Enable input Rated actuating voltage UC 24 V DC Triggering voltage range 19.2 V DC ... 30 V DC Rated actuating current IC 7 mA Switching threshold 9.6 V (“0” signal) 19.2 V (“1” signal) 04/10/2017   Page 1 / 5 https://www.phoenixcontact.com/us/products/2908670 Hybrid motor starter - ELR H5-IES-PT/500AC-9-IOL - 2908670 Technical data Input data Switching level < 5 V DC (For EMERGENCY STOP) Typical turn-off time < 30 ms Output data load output Output name AC output Rated operating voltage Ue 500 V AC Operating voltage range 42 V AC ... 550 V AC Rated operating current Ie 9 A (AC-51) 7 A (AC-53a) Mains frequency 50/60 Hz Load current range 1.5 A ... 9 A (see to derating) Trigger characteristic in acc. with IEC 60947-4-2 Class 10A Cooling time 20 min. (for auto reset) Leakage current 0 mA Type of protection Surge protection Overspeed tripping Operate threshold > 60 A Response time < 0.5 s General Switching frequency ≤ 2 Hz (Load-dependent) Mounting position vertical (horizontal DIN rail, motor output below) Mounting type DIN rail mounting Assembly instructions alignable, for spacing see derating Operating mode 100% operating factor Maximum power dissipation 7W Minimum power dissipation 0.88 W Operating voltage display Green LED Status display Yellow LED Indication Red LED Connection data, input side Connection name Control circuits Connection method Push-in connection Stripping length 10 mm Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 04/10/2017   Page 2 / 5 https://www.phoenixcontact.com/us/products/2908670 Hybrid motor starter - ELR H5-IES-PT/500AC-9-IOL - 2908670 Technical data Connection data, output side Connection name Load circuit Connection method Push-in connection Stripping length 10 mm Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 Ambient conditions Ambient temperature (operation) -5 °C ... 55 °C (observe derating) Ambient temperature (storage/transport) -40 °C ... 80 °C Degree of protection IP20 Dimensions Width 22.5 mm Height 99 mm Depth 114.5 mm UL data SCCR 100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault))) 5 kA (480 V AC (fuse: 20 A RK5 (standard fault))) FLA 7.6 A (480 V AC) Group installation 20 A (class RK5, SCCR 5kA (480 V AC), #24 - 14 AWG max. solid and stranded) 30 A (class CC or J, SCCR 100kA (480 V AC), #24 - 14 AWG max, solid and stranded) Category code NLDX / NRNT Horsepower ratings 2 hp (120 V AC / 208 V AC) 5 hp (277 V AC / 480 V AC) Insulation characteristics Rated insulation voltage 550 V Rated surge voltage 6 kV Overvoltage category III Degree of pollution 2 Designation Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit Insulation Safe isolation (IEC 60947-1) Designation Isolation characteristics between the control input and control supply voltage to auxiliary circuit Insulation Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC 04/10/2017   Page 3 / 5 https://www.phoenixcontact.com/us/products/2908670 Hybrid motor starter - ELR H5-IES-PT/500AC-9-IOL - 2908670 Technical data Standards and Regulations Designation Standards/regulations Standards/regulations IEC 60947-1 EN 60947-4-2 IEC 61508 ISO 13849 Approvals/conformities Safety Integrity Level according to IEC 61508 ≤ 3 (Safe shutdown) Category acc. to EN ISO 13849 ≤ 3 (Safe shutdown) Performance level according to ISO 13849 e (Safe shutdown) UL certificate NLDX.E228652 NRNT.E172140 Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings Block diagram ENEN+ Reset Enable + Logic µP A2/LNC NC IO-Link A1/L+ 1/L1 3/L2 5/L3 2/T1 4/T2 6/T3 C/Q Approvals Approvals Approvals UL Listed / UL Listed / cUL Listed / cUL Listed / cULus Listed Ex Approvals 04/10/2017   Page 4 / 5 https://www.phoenixcontact.com/us/products/2908670 Hybrid motor starter - ELR H5-IES-PT/500AC-9-IOL - 2908670 Approvals Approval details UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 172140 UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 228652 cUL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 172140 cUL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 228652 cULus Listed       Phoenix Contact 2017 © - all rights reserved http://www.phoenixcontact.com 04/10/2017   Page 5 / 5
2908670 价格&库存

很抱歉,暂时无法提供与“2908670”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2908670
  •  国内价格 香港价格
  • 1+2469.631671+317.38214

库存:1