0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2909575

2909575

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    AC/DC DIN RAIL SUPPLY 24V 31W

  • 数据手册
  • 价格&库存
2909575 数据手册
https://www.phoenixcontact.com/us/products/2909575 Power supply unit - QUINT4-PS/1AC/24DC/1.3/PT - 2909575 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Primary-switched power supply unit, QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 1.3 A Product Description In the power range of up to 100 W, QUINT POWER provides superior system availability in the smallest size. Preventative function monitoring and exceptional power reserves are available for applications in the low-power range. Your advantages  Starting of heavy loads with dynamic boost  Preventive function monitoring indicates critical operating states before errors occur  High efficiency and long service life, with low power dissipation and low heating  Space savings in the control cabinet, thanks to a narrow, slim-line design  Free selection between Push-in and screw connection Key Commercial Data Packing unit 1 pc GTIN GTIN 4055626356471 Weight per Piece (excluding packing) 240.000 g Custom tariff number 85044030 Country of origin Germany Technical data Dimensions Width 22.5 mm Height 106 mm 12/29/2019   Page 1 / 14 https://www.phoenixcontact.com/us/products/2909575 Power supply unit - QUINT4-PS/1AC/24DC/1.3/PT - 2909575 Technical data Dimensions Depth 90 mm Ambient conditions Degree of protection IP20 Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) Ambient temperature (start-up type tested) -40 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing) Climatic class 3K3 (in acc. with EN 60721) Degree of pollution 2 Installation height ≤ 5000 m (> 2000 m, observe derating) Input data Input voltage range 100 V AC ... 240 V AC -15 % ... +10 % 110 V DC ... 250 V DC -20 % ... +40 % Dielectric strength maximum 300 V AC 30 s Frequency range (fN) 50 Hz ... 60 Hz -10 % ... +10 % Discharge current to PE < 0.25 mA (264 V AC, 60 Hz) Current consumption 0.46 A (100 V AC) 0.37 A (120 V AC) 0.2 A (230 V AC) 0.2 A (240 V AC) Nominal power consumption 37 VA Inrush current typ. 5.9 A (at 25 °C) Mains buffering time typ. 43 ms (120 V AC) typ. 43 ms (230 V AC) Input fuse 3.15 A (slow-blow, internal) Type of protection Transient surge protection Protective circuit/component Varistor Output data Nominal output voltage 24 V DC Setting range of the output voltage (USet) 24 V DC ... 28 V DC (constant capacity) Nominal output current (IN) 1.3 A Static Boost (IStat.Boost) 1.625 A (≤ 40 °C) Dynamic Boost (IDyn.Boost) 2.6 A (≤ 60 °C (5 s)) Derating > 60 °C (2.5%/K) Connection in parallel Yes, for redundancy and increased capacity Connection in series yes 12/29/2019   Page 2 / 14 https://www.phoenixcontact.com/us/products/2909575 Power supply unit - QUINT4-PS/1AC/24DC/1.3/PT - 2909575 Technical data Output data Feedback voltage resistance ≤ 35 V DC Protection against overvoltage at the output (OVP) ≤ 32 V DC Control deviation < 0.5 % (Static load change 10 % ... 90 %) < 2 % (Dynamic load change 10 % ... 90 %, (10 Hz)) < 0.1 % (change in input voltage ±10 %) Residual ripple < 40 mVPP (with nominal values) Output power 30 W Typical response time 500 ms Maximum power dissipation in no-load condition < 0.4 W (230 V AC) < 0.4 W (120 V AC) Power loss nominal load max. < 3.7 W (120 V AC) < 3.1 W (230 V AC) General Net weight 0.188 kg Efficiency typ. 89.2 % (120 V AC) typ. 90.7 % (230 V AC) Insulation voltage input/output 4 kV AC (type test) 3 kV AC (routine test) Protection class II Degree of protection IP20 MTBF (IEC 61709, SN 29500) > 1904000 h (25 °C) > 1107000 h (40 °C) > 486000 h (60 °C) Assembly instructions DIN rail mounting Connection data, input Connection method Push-in connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 14 Stripping length 10 mm Connection data, output Connection method Push-in connection Conductor cross section solid min. 0.2 mm² 12/29/2019   Page 3 / 14 https://www.phoenixcontact.com/us/products/2909575 Power supply unit - QUINT4-PS/1AC/24DC/1.3/PT - 2909575 Technical data Connection data, output Conductor cross section solid max. 2.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 14 Stripping length 10 mm Connection data for signaling Connection method Push-in connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 14 Stripping length 10 mm Standards EMC requirements for noise immunity EN 61000-6-1 EN 61000-6-2 EMC requirements for noise emission EN 61000-6-3 EN 61000-6-4 Standard - Safety of transformers EN 61558-2-16 Standard - Electrical safety IEC 61010-2-201 (SELV) Standard - safety for equipment for measurement, control, and laboratory use IEC 61010-1 Standard – Safety extra-low voltage IEC 61010-1 (SELV) IEC 61010-2-201 (PELV) Standard - Safe isolation IEC 61558-2-16 Standard - power supply devices for low voltage with DC output EN 61204-3 Standard – Limitation of mains harmonic currents EN 61000-3-2 Conformance/approvals UL approvals UL Listed UL 61010-1 UL Listed UL 61010-2-201 UL 1310 Class 2 Power Units ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location) SIQ CB-Scheme (IEC 61010-1, IEC 61010-2-201) 12/29/2019   Page 4 / 14 https://www.phoenixcontact.com/us/products/2909575 Power supply unit - QUINT4-PS/1AC/24DC/1.3/PT - 2909575 Technical data EMC data Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Conducted noise emission EN 55016 EN 61000-6-3 (Class B) Noise emission EN 55016 EN 61000-6-3 (Class B) Harmonic currents EN 61000-3-2 EN 61000-3-2 (Class A) Flicker EN 61000-3-3 Electrostatic discharge EN 61000-4-2 Contact discharge 8 kV (Test Level 4) Discharge in air 8 kV (Test Level 3) Electromagnetic HF field EN 61000-4-3 Frequency range 80 MHz ... 1 GHz Test field strength 20 V/m (Test Level 3) Frequency range 1 GHz ... 6 GHz Test field strength 10 V/m (Test Level 3) Comments Criterion A Fast transients (burst) EN 61000-4-4 Input 4 kV (Test Level 4 - asymmetrical) Output 4 kV (Test Level X - asymmetrical) Signal 4 kV (Test Level X - asymmetrical) Comments Criterion A Surge voltage load (surge) EN 61000-4-5 Input 2 kV (Test Level 4 - symmetrical) 4 kV (Test Level 4 - asymmetrical) Output 1 kV (Test Level 3 - symmetrical) 2 kV (Test Level 3 - asymmetrical) Signal 0.5 kV (Test Level 2 - symmetrical) Comments Criterion A I/O/S asymmetrical Frequency range 0.15 MHz ... 80 MHz Voltage 10 V (Test Level 3) Comments Criterion A Frequency 16.67 Hz 50 Hz 60 Hz Test field strength 100 A/m 12/29/2019   Page 5 / 14 https://www.phoenixcontact.com/us/products/2909575 Power supply unit - QUINT4-PS/1AC/24DC/1.3/PT - 2909575 Technical data EMC data Additional text 60 s Comments Criterion A Frequency 50 Hz 60 Hz Test field strength 1 kA/m Additional text 3s Frequency 0 Hz Test field strength 300 A/m Additional text DC, 60 s Voltage dips EN 61000-4-11 Voltage 100 V AC Frequency 60 Hz Voltage dip 70 % Number of periods 0.5 / 1 / 30 periods Additional text Test Level 2 Comments Criterion A Voltage dip 40 % Number of periods 5 / 10 / 50 periods Additional text Test Level 2 Comments Criterion B Voltage dip 0% Number of periods 0.5 / 1 / 5 / 50 periods Additional text Test Level 2 Comments Criterion B Pulse-shape magnetic field EN 61000-4-9 Test field strength 1000 A/m Comments Criterion A Attenuated sinusoidal oscillations (ring wave) EN 61000-4-12 Input 2 kV (symmetrical) 4 kV (asymmetrical) Comments Criterion A Asymmetrical conducted disturbance variables EN 61000-4-16 Test level 1 16.67 Hz 50 Hz 60 Hz (Test Level 2) Voltage 30 V (10 s) Test level 2 16.67 Hz 50 Hz 60 Hz (Test Level 4) Voltage 300 V (1 s) Comments Criterion A 12/29/2019   Page 6 / 14 https://www.phoenixcontact.com/us/products/2909575 Power supply unit - QUINT4-PS/1AC/24DC/1.3/PT - 2909575 Technical data EMC data Criterion A Criterion A Normal operating behavior within the specified limits. Criterion B Temporary impairment to operational behavior that is corrected by the device itself. Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. Environmental Product Compliance Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 25; For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings 12/29/2019   Page 7 / 14 https://www.phoenixcontact.com/us/products/2909575 Power supply unit - QUINT4-PS/1AC/24DC/1.3/PT - 2909575 Dimensional drawing 12/29/2019   Page 8 / 14 https://www.phoenixcontact.com/us/products/2909575 Power supply unit - QUINT4-PS/1AC/24DC/1.3/PT - 2909575 Schematic diagram 12/29/2019   Page 9 / 14 https://www.phoenixcontact.com/us/products/2909575 Power supply unit - QUINT4-PS/1AC/24DC/1.3/PT - 2909575 Diagram Diagram 12/29/2019   Page 10 / 14 https://www.phoenixcontact.com/us/products/2909575 Power supply unit - QUINT4-PS/1AC/24DC/1.3/PT - 2909575 Diagram Block diagram 12/29/2019   Page 11 / 14 https://www.phoenixcontact.com/us/products/2909575 Power supply unit - QUINT4-PS/1AC/24DC/1.3/PT - 2909575 Classifications eCl@ss eCl@ss 5.1 27242213 eCl@ss 6.0 27049000 eCl@ss 7.0 27049002 eCl@ss 8.0 27049002 eCl@ss 9.0 27040701 ETIM ETIM 6.0 EC002540 ETIM 7.0 EC002540 UNSPSC UNSPSC 13.2 39121004 UNSPSC 18.0 39121004 UNSPSC 19.0 39121004 UNSPSC 20.0 39121004 UNSPSC 21.0 39121004 Approvals Approvals Approvals DNV GL / UL Listed / IECEE CB Scheme / cUL Listed / EAC / cULus Listed Ex Approvals UL Listed / cUL Listed / cULus Listed Approval details DNV GL    https://approvalfinder.dnvgl.com/  TAA00001SN UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 123528 12/29/2019   Page 12 / 14 https://www.phoenixcontact.com/us/products/2909575 Power supply unit - QUINT4-PS/1AC/24DC/1.3/PT - 2909575 Approvals IECEE CB Scheme    http://www.iecee.org/  SI-6241 cUL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 123528 EAC      RU CDE.A*30.B.01082 cULus Listed       Accessories Accessories Device circuit breakers Electronic device circuit breaker - CBMC E4 24DC/1-10A NO - 2906032 Multi-channel electronic device circuit breaker for protecting four loads at 24 V DC in the event of overload and short circuit. With electronic locking of the set nominal currents. For installation on DIN rails.     Electronic device circuit breaker - CBMC E4 24DC/1-4A NO - 2906031 Multi-channel electronic device circuit breaker for protecting four loads at 24 V DC in the event of overload and short circuit. With electronic locking of the set nominal currents. For installation on DIN rails.     12/29/2019   Page 13 / 14 https://www.phoenixcontact.com/us/products/2909575 Power supply unit - QUINT4-PS/1AC/24DC/1.3/PT - 2909575 Accessories Electronic device circuit breaker - CBMC E4 24DC/1-4A NO-C - 2908713 Multi-channel electronic device circuit breaker that can be preconfigured, for protecting four loads at 24 V DC in the event of overload and short circuit. With electronic locking of the set nominal currents. For installation on DIN rails.     Device protection Type 3 surge protection device - PLT-SEC-T3-230-FM-PT - 2907928 Type 2/3 surge protection, consisting of protective plug and base element with Push-in connection. For single-phase power supply network with integrated status indicator and remote signaling. Nominal voltage 230 V AC/DC.     Type 3 surge protection device - PLT-SEC-T3-24-FM-PT - 2907925 Type 3 surge protection, consisting of protective plug and base element, with integrated status indicator and remote signaling for single-phase power supply networks. Nominal voltage 24 V AC/DC.     Screwdriver tools Screwdriver - SF-SL 0,4X2,0-60 - 1212546 Screwdriver, flat bladed, size: 0.4 x 2.0 x 60 mm, 2-component grip, with non-slip grip     Phoenix Contact 2019 © - all rights reserved http://www.phoenixcontact.com 12/29/2019   Page 14 / 14
2909575 价格&库存

很抱歉,暂时无法提供与“2909575”相匹配的价格&库存,您可以联系我们找货

免费人工找货