0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2909669

2909669

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    通用 继电器 SPDT(1 Form C) 120VAC/DC 线圈 DIN 轨道

  • 数据手册
  • 价格&库存
2909669 数据手册
https://www.phoenixcontact.com/us/products/2909669 Relay Module - PLC-RPT-120UC/21/MS - 2909669 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) PLC-INTERFACE, consisting of PLC-BPT.../21 basic terminal block with Push-in connection and plug-in miniature relay with power contact and manual operation, 1 changeover contact, 120 V AC/110 V DC input voltage The figure shows the 24 V DC version Why buy this product  Slim design  Efficient connection to system cabling using V8 adapter  RT III sealed relay  Safe isolation according to DIN EN 50178 between coil and contact  Functional plug-in bridges  Integrated input circuit and interference suppression circuit Key Commercial Data Packing unit 1 GTIN GTIN 4055626378022 Custom tariff number 85364900 Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 6.2 mm Height 80 mm 04/10/2017   Page 1 / 5 https://www.phoenixcontact.com/us/products/2909669 Relay Module - PLC-RPT-120UC/21/MS - 2909669 Technical data Dimensions Depth 94 mm Ambient conditions Ambient temperature (operation) -40 °C ... 55 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Coil side Nominal input voltage UN 120 V AC 110 V DC Typical input current at UN 3.5 mA (at UN = 120 V AC) 3 mA (at UN = 110 V DC) Typical response time 6 ms Typical release time 15 ms Protective circuit Bridge rectifier Bridge rectifier Operating voltage display Yellow LED Power dissipation for nominal condition 0.42 W Contact side Contact type 1 PDT Type of switch contact Single contact Contact material AgSnO Maximum switching voltage 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) Minimum switching voltage 5 V (at 100 mA) Min. switching current 10 mA (at 12 V) Maximum inrush current 10 A (4 s) Limiting continuous current 6A Interrupting rating (ohmic load) max. 140 W (at 24 V DC) 20 W (at 48 V DC) 18 W (at 60 V DC) 23 W (at 110 V DC) 40 W (at 220 V DC) 1500 VA (for 250 V AC) Switching capacity in acc. with DIN VDE 0660/IEC 60947 2 A (at 24 V, DC13) 0.2 A (at 110 V, DC13) 0.1 A (at 220 V, DC13) 3 A (at 24 V, AC15) 3 A (at 120 V, AC15) 04/10/2017   Page 2 / 5 https://www.phoenixcontact.com/us/products/2909669 Relay Module - PLC-RPT-120UC/21/MS - 2909669 Technical data Contact side 3 A (at 230 V, AC15) Connection data input side Connection name Coil side Connection method Push-in connection Stripping length 8 mm Conductor cross section solid 0.14 mm² ... 2.5 mm² Conductor cross section flexible 0.14 mm² ... 2.5 mm² Conductor cross section AWG 26 ... 14 Connection data output side Connection name Contact side Connection method Push-in connection Stripping length 8 mm Conductor cross section solid 0.14 mm² ... 2.5 mm² Conductor cross section flexible 0.14 mm² ... 2.5 mm² Conductor cross section AWG 26 ... 14 General Note Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or FBST 500.... Test voltage relay winding/relay contact 4 kV AC (50 Hz, 1 min.) Operating mode 100% operating factor Degree of protection RT II (flux-proof) (Relay) IP20 (Relay socket) Mechanical service life 1 x 10 cycles Flammability rating according to UL 94 V0 Mounting position any Assembly instructions In rows with zero spacing 7 Standards and Regulations Designation Standards/regulations Standards/regulations IEC 60664 IEC 60664A DIN VDE 0110 DIN EN 50178/DIN VDE 0160 (in relevant parts) DIN EN 50178/VDE 0160 IEC 60255/DIN VDE 0435 (in relevant parts) Degree of pollution 3 04/10/2017   Page 3 / 5 https://www.phoenixcontact.com/us/products/2909669 Relay Module - PLC-RPT-120UC/21/MS - 2909669 Technical data Standards and Regulations Overvoltage category III Flammability rating according to UL 94 V0 Conformance CE-compliant Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings Diagram Circuit diagram A2 11 A1 14 12 Interrupting rating Articles in set Relay socket - PLC-BPT-120UC/21 - 2900280 6.2 mm PLC basic terminal block with push-in connection, without relay or solid-state relay, for mounting on DIN rail NS 35/7,5, 1 PDT, input voltage 120 V AC/DC     Single relay - REL-MR- 60DC/21/MS - 2909643 Plug-in miniature power relay, with power contact, 1 changeover contact, manual operation, 60 V DC input voltage     04/10/2017   Page 4 / 5 https://www.phoenixcontact.com/us/products/2909669 Relay Module - PLC-RPT-120UC/21/MS - 2909669 Articles in set Phoenix Contact 2017 © - all rights reserved http://www.phoenixcontact.com 04/10/2017   Page 5 / 5
2909669 价格&库存

很抱歉,暂时无法提供与“2909669”相匹配的价格&库存,您可以联系我们找货

免费人工找货