https://www.phoenixcontact.com/us/products/2910374
Type 1 surge protection device - VAL-US-277/40/3+1-FM - 2910374
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Surge protective device, four channel with remote indicator contact for 277/480 V AC, 4-wire plus ground.
Your advantages
With floating remote indication contact
Optical, mechanical status indication for the individual arresters
Mechanical coding of all slots
Multi-channel type 2 arresters
Key Commercial Data
Packing unit
1 pc
GTIN
GTIN
4055626445137
Weight per Piece (excluding packing)
280.000 g
Custom tariff number
85363030
Country of origin
Germany
Technical data
Dimensions
Height
98.7 mm
Width
71.2 mm
Depth
65.5 mm
Horizontal pitch
4 Div.
Ambient conditions
06/28/2020 Page 1 / 12
https://www.phoenixcontact.com/us/products/2910374
Type 1 surge protection device - VAL-US-277/40/3+1-FM - 2910374
Technical data
Ambient conditions
Degree of protection
IP20 (only when all terminal points are used)
Ambient temperature (operation)
-40 °C ... 80 °C
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Altitude
≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)
5 % ... 95 %
Shock (operation)
25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)
5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
General
IEC test classification
II
T2
EN type
T2
IEC power supply system
TN-S
TT
Mode of protection
L-N
L-PE
N-PE
Mounting type
DIN rail: 35 mm
Color
jet black RAL 9005
Housing material
PA 6.6
PBT
Degree of pollution
2
Flammability rating according to UL 94
V-0
Type
DIN rail module, two-section, divisible
Number of positions
4
Surge protection fault message
Optical, remote indicator contact
Protective circuit
Nominal voltage UN
277/480 V AC (TN-S/TT)
Nominal frequency fN
50 Hz (60 Hz)
Maximum continuous operating voltage UC (L-N)
385 V AC
Maximum continuous voltage UC (N-PE)
305 V AC
Residual current IPE
≤ 5 µA
Nominal discharge current In (8/20) µs
20 kA
Maximum discharge current Imax (8/20) µs
40 kA
Follow current interrupt rating Ifi (N-PE)
100 A (305 V AC)
Short-circuit current rating ISCCR
25 kA
Voltage protection level Up (L-N)
≤ 2 kV
06/28/2020 Page 2 / 12
https://www.phoenixcontact.com/us/products/2910374
Type 1 surge protection device - VAL-US-277/40/3+1-FM - 2910374
Technical data
Protective circuit
Voltage protection level Up (L-PE)
≤ 2.2 kV
Voltage protection level Up (N-PE)
≤ 1.5 kV
Residual voltage Ures (L-N)
≤ 2 kV (at In)
≤ 1.7 kV (at 10 kA)
≤ 1.5 kV (at 5 kA)
≤ 1.3 kV (at 3 kA)
Residual voltage Ures (L-PE)
≤ 2.2 kV (at In)
≤ 1.7 kV (at 10 kA)
≤ 1.5 kV (at 5 kA)
≤ 1.4 kV (at 3 kA)
Residual voltage Ures (N-PE)
≤ 0.4 kV (at In)
≤ 0.25 kV (at 10 kA)
≤ 0.15 kV (at 5 kA)
≤ 0.1 kV (at 3 kA)
TOV behavior at UT (L-N)
480 V AC (5 s / withstand mode)
530 V AC (120 min / safe failure mode)
TOV behavior at UT (N-PE)
1200 V AC (200 ms / withstand mode)
Max. backup fuse with branch wiring
125 A (gG)
Indicator/remote signaling
Switching function
PDT contact
Operating voltage
5 V AC ... 250 V AC
30 V DC
Operating current
5 mA AC ... 750 mA AC
1 A DC
Connection method
Plug-in/screw connection via COMBICON
Screw thread
M2
Tightening torque
0.25 Nm
Stripping length
7 mm
Conductor cross section flexible
0.14 mm² ... 1.5 mm²
Conductor cross section solid
0.14 mm² ... 1.5 mm²
Conductor cross section AWG
28 ... 16
Connection data
Connection method
Screw connection
Screw thread
M5
Tightening torque
3 Nm (1.5 mm² ... 16 mm²)
4.5 Nm (25 mm² ... 35 mm²)
06/28/2020 Page 3 / 12
https://www.phoenixcontact.com/us/products/2910374
Type 1 surge protection device - VAL-US-277/40/3+1-FM - 2910374
Technical data
Connection data
Stripping length
16 mm
Conductor cross section flexible
1.5 mm² ... 25 mm²
Conductor cross section solid
1.5 mm² ... 35 mm²
Conductor cross section AWG
15 ... 2
Connection method
Fork-type cable lug
Conductor cross section flexible
1.5 mm² ... 16 mm²
UL specifications
SPD Type
1
Maximum continuous operating voltage MCOV (L-L)
750 V AC
Maximum continuous operating voltage MCOV (L-N)
385 V AC
Maximum continuous operating voltage MCOV (L-G)
385 V AC
Maximum continuous operating voltage MCOV (N-G)
305 V AC
Nom. voltage
277/480 V AC (Wye)
Mode of protection
L-N
N-G
L-G
Power distribution system
Wye
Nominal frequency
50/60 Hz
Voltage protection rating VPR (L-L)
2500 V
Voltage protection rating VPR (L-N)
1500 V
Voltage protection rating VPR (L-G)
2000 V
Voltage protection rating VPR (N-G)
1200 V
Nominal discharge current In
20 kA
Maximum Surge Current per Phase
40 kA
Short-circuit current rating (SCCR)
200 kA
UL indicator/remote signaling
Operating voltage
125 V AC
Operating current
1 A AC
Tightening torque
2 lbf-in. ... 4 lbf-in.
Conductor cross section AWG
30 ... 14
UL connection data
Conductor cross section AWG
10 ... 2
Tightening torque
30 lbf-in.
Standards and Regulations
Standards/regulations
IEC 61643-11 2011
06/28/2020 Page 4 / 12
https://www.phoenixcontact.com/us/products/2910374
Type 1 surge protection device - VAL-US-277/40/3+1-FM - 2910374
Technical data
Standards and Regulations
EN 61643-11 2012
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
Drawings
Dimensional drawing
06/28/2020 Page 5 / 12
https://www.phoenixcontact.com/us/products/2910374
Type 1 surge protection device - VAL-US-277/40/3+1-FM - 2910374
Circuit diagram
Classifications
eCl@ss
eCl@ss 10.0.1
27130805
eCl@ss 6.0
27130800
eCl@ss 7.0
27130805
eCl@ss 8.0
27130805
eCl@ss 9.0
27130805
ETIM
ETIM 5.0
EC000941
ETIM 6.0
EC000941
ETIM 7.0
EC000941
Approvals
Approvals
06/28/2020 Page 6 / 12
https://www.phoenixcontact.com/us/products/2910374
Type 1 surge protection device - VAL-US-277/40/3+1-FM - 2910374
Approvals
Approvals
UL Listed / cUL Listed / cULus Listed
Ex Approvals
Approval details
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 330181
cUL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 330181
cULus Listed
Accessories
Accessories
Bridge
Wiring bridge - MPB F600X16/ 1GS - 2818355
Wiring bridge flexible, diameter: 16 mm², with a fork-type cable lug on one side, length: 600 mm
Wiring bridge - MPB F600X16/ 1GS - 2818355
Wiring bridge flexible, diameter: 16 mm², with a fork-type cable lug on one side, length: 600 mm
06/28/2020 Page 7 / 12
https://www.phoenixcontact.com/us/products/2910374
Type 1 surge protection device - VAL-US-277/40/3+1-FM - 2910374
Accessories
Wiring bridge - MPB F200X16/ 1GS - 2818339
Wiring bridge flexible, diameter 16 mm², with a fork-type cable lug on one side, length: 200 mm
Wiring bridge - MPB 18/1-10/1.0.0 - 2830443
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 10 pitches with contact sequence 1-0-0
Wiring bridge - MPB 18/4-12 - 2809296
Wiring bridge for modules with connecting pitch 17.5 mm, 4-phase, 12-pos.
Wiring bridge - MPB 18/4- 8 - 2809283
Wiring bridge for modules with connecting pitch 17.5 mm, 4-phase, 8-pos.
Wiring bridge - MPB 18/3- 6 - 2809241
Wiring bridge for modules with connecting pitch 17.5 mm, 3-phase, 6-pos.
06/28/2020 Page 8 / 12
https://www.phoenixcontact.com/us/products/2910374
Type 1 surge protection device - VAL-US-277/40/3+1-FM - 2910374
Accessories
Wiring bridge - MPB 18/1-57 - 2809238
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 57-pos.
Wiring bridge - MPB 18/1-12 - 2748593
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 12-pos.
Wiring bridge - MPB 18/1- 9 - 2748580
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 9-pos.
Wiring bridge - MPB 18/1- 8 - 2748577
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 8-pos.
Wiring bridge - MPB 18/1- 6 - 2748564
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 6-pos.
06/28/2020 Page 9 / 12
https://www.phoenixcontact.com/us/products/2910374
Type 1 surge protection device - VAL-US-277/40/3+1-FM - 2910374
Accessories
Wiring bridge - MPB 18/1- 4 - 2809225
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 4-pos.
Wiring bridge - MPB 18/1- 3 - 2809212
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 3-pos.
Wiring bridge - MPB 18/1- 2 - 2809209
Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 2-pos.
Device marking
Zack marker strip - ZBN 18:UNBEDRUCKT - 2809128
Zack marker strip, Strip, white, unlabeled, can be labeled with: CMS-P1-PLOTTER, PLOTMARK, mounting type: snap
into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5
Feed-through terminal block
Feed-through terminal block - DK-BIC-35 - 2749880
Feed-through terminal block for VAL and FLT applications
06/28/2020 Page 10 / 12
https://www.phoenixcontact.com/us/products/2910374
Type 1 surge protection device - VAL-US-277/40/3+1-FM - 2910374
Accessories
Labeled device marker
Marker for terminal blocks - ZBN 18,LGS:ERDE - 2749589
Marker for terminal blocks, Strip, white, labeled, horizontal: Grounding symbol, mounting type: snap into tall marker
groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5
Marker for terminal blocks - ZBN 18,LGS:L1-N,ERDE - 2749576
Marker for terminal blocks, Strip, white, labeled, horizontal: L1, L2, L3, N, GND, mounting type: snap into tall marker
groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5
Marker pen
Marker pen - B-STIFT - 1051993
Marker pen, for manual labeling of unprinted Zack strips, smear-proof and waterproof, line thickness 0.5 mm
Spare parts
Type 1 surge protection plug - VAL-US-277/40-P - 2910338
UL Recognized type 1 SPD and IEC type 2 surge protection plug with a varistor and thermal disconnect for use with VALUS base elements, mechanical and visual fault warning
06/28/2020 Page 11 / 12
https://www.phoenixcontact.com/us/products/2910374
Type 1 surge protection device - VAL-US-277/40/3+1-FM - 2910374
Accessories
Type 1 surge protection plug - GDT-US-NG/40-P - 2910342
UL Recognized type 1 SPD and IEC type 2 surge protection plug with a gas discharge tube and thermal disconnect for
use with VAL-US base elements, mechanical and visual fault warning
Phoenix Contact 2020 © - all rights reserved
http://www.phoenixcontact.com
06/28/2020 Page 12 / 12