2924854

2924854

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    TC-D37SUB-ADIO16-EX-P-UNI

  • 数据手册
  • 价格&库存
2924854 数据手册
https://www.phoenixcontact.com/us/products/2924854 Module carrier - TC-D37SUB-ADIO16-EX-P-UNI - 2924854 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Universal termination carrier for connecting 16 MACX Analog Ex i signal conditioners to digital or analog I/O cards, via D-SUB connector, 37-pos. (1:1 connection) Your advantages  Mechanically decoupled, passive PCB  Robust aluminum profile with integrated DIN rail  Side parts with integrated end clamps  D-SUB pin strip system connection, 37-pos. (1:1 connection)  Simple or redundant supply (decoupled from diode, protected against polarity reversal) and monitoring function implemented via separate DIN rail module  Cable sets for signal connection are supplied as standard and do not have to be ordered separately Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356592017 Weight per Piece (excluding packing) 1.160 g Custom tariff number 85366990 Country of origin Germany Technical data Dimensions Width 242 mm Height 170 mm Depth 160 mm 09/10/2019   Page 1 / 14 https://www.phoenixcontact.com/us/products/2924854 Module carrier - TC-D37SUB-ADIO16-EX-P-UNI - 2924854 Technical data Ambient conditions Ambient temperature (operation) -20 °C ... 60 °C (Please observe module specifications) Ambient temperature (storage/transport) -40 °C ... 80 °C Maximum altitude ≤ 2000 m Permissible humidity (operation) 5 % ... 95 % (non-condensing) Degree of protection IP00 Shock 15g, according to IEC 60068-2-27 Vibration (operation) 2g, according to IEC 60068-2-6 General Nominal voltage UN < 30 V DC (Per signal/channel) Max. permissible current 1 A (Signal/channel) Color gray Supply Designation Power module Note Power supply via 2904673 TC-MACX-MCR-PTB power supply and error signaling module. Input voltage 24 V DC Input voltage range 19.2 V DC ... 30 V DC Input current ≤2A Redundant supply yes, decoupled from diodes Polarization and surge protection Yes Output name Switching output Contact type 1 N/C contact (alarm = open) Maximum switching voltage 50 V DC (0.3 A) Fuse 2x 2.5 A on PCB, slow-blow (replaceable) Status display 1 x red LED (error) 2x green LEDs (PWR1 and PWR2) Connection data Connection name Power supply Connection method Screw connection Stripping length 7 mm Number of connections 1 Number of positions 6 Conductor cross section solid 0.14 mm² ... 2.5 mm² Conductor cross section flexible 0.14 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 12 Connection data 2 09/10/2019   Page 2 / 14 https://www.phoenixcontact.com/us/products/2924854 Module carrier - TC-D37SUB-ADIO16-EX-P-UNI - 2924854 Technical data Connection data 2 Connection name Controller level Connection method D-SUB pin strip Number of connections 1 Number of positions 37 Standards and Regulations Designation Air clearances and creepage distances Standards/regulations DIN EN 50178 Rated insulation voltage 50 V Rated surge voltage 0.5 kV Insulation Basic insulation Degree of pollution 2 Overvoltage category II Shock 15g, according to IEC 60068-2-27 Vibration (operation) 2g, according to IEC 60068-2-6 ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA/Canada UL 61010 Listed Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, Group IIC Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings 09/10/2019   Page 3 / 14 https://www.phoenixcontact.com/us/products/2924854 Module carrier - TC-D37SUB-ADIO16-EX-P-UNI - 2924854 Circuit diagram Articles in set Cable set - TC-C-MAX2-SC-31320000 - 2902425 Cable set for signal transmission on the Termination Carrier for modules from the MACX Analog Ex series. Connection of terminal points 3.1 and 3.2 (signal transmission) to the signal PCB.     Cable set - TC-C-PTB3-SC-SET1 - 2905216 Cable set for TC-MACX-MCR-PTB power and fault signaling module (Order No. 2904673), for use on the Termination Carrier for signal conditioners from the MACX Analog Ex series.     DIN rail bus connectors - ME 17,5 TBUS 1,5/ 5-ST-3,81 GN - 2709561 DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold-plated contacts, 5-pos.     09/10/2019   Page 4 / 14 https://www.phoenixcontact.com/us/products/2924854 Module carrier - TC-D37SUB-ADIO16-EX-P-UNI - 2924854 Articles in set DIN rail bus connectors - ME 6,2 TBUS-2 1,5/5-ST-3,81 GN - 2869728 DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold-plated contacts, 5-pos.     Classifications eCl@ss eCl@ss 4.0 27210100 eCl@ss 4.1 27210100 eCl@ss 5.0 27371600 eCl@ss 5.1 27371600 eCl@ss 6.0 27371600 eCl@ss 7.0 27141152 eCl@ss 8.0 27141152 eCl@ss 9.0 27141152 ETIM ETIM 4.0 EC002780 ETIM 5.0 EC002780 ETIM 6.0 EC002780 ETIM 7.0 EC002780 UNSPSC UNSPSC 6.01 30211811 UNSPSC 7.0901 39121410 UNSPSC 11 39121410 UNSPSC 12.01 39121410 UNSPSC 13.2 39121432 Approvals Approvals Approvals UL Listed / cUL Listed / EAC / cULus Listed 09/10/2019   Page 5 / 14 https://www.phoenixcontact.com/us/products/2924854 Module carrier - TC-D37SUB-ADIO16-EX-P-UNI - 2924854 Approvals Ex Approvals ATEX / UL Listed / cUL Listed / cULus Listed Approval details  UL Listed   http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm     Nominal voltage UN 50 V Nominal current IN 1A  cUL Listed   http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm     Nominal voltage UN 50 V Nominal current IN 1A EAC  cULus Listed   FILE E 330267  FILE E 330267     RU CDE.A*30.B.01742      Accessories Necessary add-on products Power and error message module - TC-MACX-MCR-PTB - 2904673 Power and fault signaling module with screw connection, only for use on the Termination Carrier, excluding corresponding DIN rail bus connector     09/10/2019   Page 6 / 14 https://www.phoenixcontact.com/us/products/2924854 Module carrier - TC-D37SUB-ADIO16-EX-P-UNI - 2924854 Accessories Power/input isolating amplifier - MACX MCR-EX-SL-RPSSI-I - 2865340 Ex i repeater power supply and input signal conditioner, HART. Transmits supplied or active 0/4 - 20 mA signals from the hazardous area to a load (active or passive) in the safe area. 3-way electrical isolation; SIL 2 according to IEC 61508, with screw connection     Temperature measuring transducer - MACX MCR-EX-SL-RTD-I - 2865939 Ex i temperature transducer: converts signals from resistance temperature detectors installed in the Ex area and transmits a 0/4 - 20 mA signal to a load in the safe area. Freely programmable. 3-way isolation, screw connection, order configuration.     Temperature measuring transducer - MACX MCR-EX-SL-TC-I - 2865942 Ex i temperature measuring transducer: Converts signals from thermocouples installed in Ex areas and mV sources and transmits a 0/4-20 mA signal to a load in the safe area. Freely programmable. 3-way isolation, custom-configured.     Output signal conditioner - MACX MCR-EX-SL-IDSI-I - 2865405 Ex i output signal conditioner, HART Isolates and sends intrinsically safe 0/4-20 mA signals to a load (I/P converters, control valves, displays) in Ex areas. Electrical 3-way isolation, wire break recognition, SIL 2 in accordance with IEC 61508.     Isolation amplifier - MACX MCR-EX-SL-NAM-R - 2865434 Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via a relay output (PDT contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.     09/10/2019   Page 7 / 14 https://www.phoenixcontact.com/us/products/2924854 Module carrier - TC-D37SUB-ADIO16-EX-P-UNI - 2924854 Accessories Isolation amplifier - MACX MCR-EX-SL-NAM-2RO - 2865450 Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via 2 relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.     Isolation amplifier - MACX MCR-EX-SL-NAM-2T - 2865463 Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via 2 transistor outputs (passive) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.     Signal isolator - MACX MCR-EX-SL-NAM-NAM - 2866006 Ex i NAMUR signal conditioner. For operating Ex i proximity sensors and switches in the Ex area. Passive transistor output (resistive according to EN 60947-5-6), line fault transparency, up to SIL 2 according to IEC 61508; screw connection.     Isolation amplifier - MACX MCR-EX-SL-NAM-HO - 2907404 Ex i NAMUR signal conditioners. For operating Ex i proximity sensors and switches in hazardous areas. Passive transistor output (resistive, Honeywell-compatible), line fault transparency, up to SIL 2 according to IEC 61508; screw connection.     Solenoid driver - MACX MCR-EX-SL-SD-21-25-LP - 2865492 Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 25 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Screw connection.     09/10/2019   Page 8 / 14 https://www.phoenixcontact.com/us/products/2924854 Module carrier - TC-D37SUB-ADIO16-EX-P-UNI - 2924854 Accessories Solenoid driver - MACX MCR-EX-SL-SD-21-40-LP - 2865764 Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 40 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Screw connection.     Solenoid driver - MACX MCR-EX-SL-SD-24-48-LP - 2865609 Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 48 mA. For gases up to Group IIC, loop-powered, electrical isolation, SIL 3. Screw connection.     Solenoid driver - MACX MCR-EX-SL-SD-21-60-LP - 2865515 Ex i solenoid driver. For the intrinsically safe control of Ex i solenoid valves, alarm modules or LEDs installed in the Ex area. Current limitation at 58 mA. For gases up to Group IIB, loop-powered, electrical isolation, SIL 3. Screw connection.     Solenoid driver - MACX MCR-EX-SL-SD-21-25-LFD - 2905669 Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 21.1 V, current limitation at 25.1 mA, line fault transparency, error message output, up to SIL 3 according to IEC 61508; screw connection.     Solenoid driver - MACX MCR-EX-SL-SD-23-48-LFD - 2924867 Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 22.6 V, current limitation at 48 mA, , line fault transparency, error message output, up to SIL 3 according to IEC 61508, screw connection     09/10/2019   Page 9 / 14 https://www.phoenixcontact.com/us/products/2924854 Module carrier - TC-D37SUB-ADIO16-EX-P-UNI - 2924854 Accessories Solenoid driver - MACX MCR-EX-SL-SD-24-48-LFD - 2906155 Ex i solenoid driver for controlling Ex i solenoid valves in hazardous areas, logic input, off-load voltage 24.3 V, current limitation at 48 mA, line fault transparency, error message output, up to SIL 3 according to IEC 61508; screw connection.     Cable - CABLE-D37SUB/B/B/ 100/KONFEK/S - 2305509 Assembled shielded round cable; connection 1: D-SUB socket strip (1x 37-position); connection 2: D-SUB socket strip (1x 37-position); cable length: 1 m     Cable - CABLE-D37SUB/B/B/ 200/KONFEK/S - 2305512 Assembled shielded round cable; connection 1: D-SUB socket strip (1x 37-position); connection 2: D-SUB socket strip (1x 37-position); cable length: 2 m     Cable - CABLE-D37SUB/B/B/ 300/KONFEK/S - 2305525 Assembled shielded round cable; connection 1: D-SUB socket strip (1x 37-position); connection 2: D-SUB socket strip (1x 37-position); cable length: 3 m     Cable - CABLE-D37SUB/B/B/ 400/KONFEK/S - 2900759 Assembled shielded round cable; connection 1: D-SUB socket strip (1x 37-position); connection 2: D-SUB socket strip (1x 37-position); cable length: 4 m     09/10/2019   Page 10 / 14 https://www.phoenixcontact.com/us/products/2924854 Module carrier - TC-D37SUB-ADIO16-EX-P-UNI - 2924854 Accessories Cable - CABLE-D37SUB/B/B/ 600/KONFEK/S - 2900760 Assembled shielded round cable; connection 1: D-SUB socket strip (1x 37-position); connection 2: D-SUB socket strip (1x 37-position); cable length: 6 m     Cable - CABLE-D37SUB/B/B/ 800/KONFEK/S - 2900761 Assembled shielded round cable; connection 1: D-SUB socket strip (1x 37-position); connection 2: D-SUB socket strip (1x 37-position); cable length: 8 m     Cable - CABLE-D37SUB/B/B/1000/KONFEK/S - 2900762 Assembled shielded round cable; connection 1: D-SUB socket strip (1x 37-position); connection 2: D-SUB socket strip (1x 37-position); cable length: 10 m     Cable - CABLE-D37SUB/B/B/1500/KONFEK/S - 2900763 Assembled shielded round cable; connection 1: D-SUB socket strip (1x 37-position); connection 2: D-SUB socket strip (1x 37-position); cable length: 15 m     Cable - CABLE-D37SUB/B/B/2000/KONFEK/S - 2900764 Assembled shielded round cable; connection 1: D-SUB socket strip (1x 37-position); connection 2: D-SUB socket strip (1x 37-position); cable length: 20 m     09/10/2019   Page 11 / 14 https://www.phoenixcontact.com/us/products/2924854 Module carrier - TC-D37SUB-ADIO16-EX-P-UNI - 2924854 Accessories Cable - CABLE-D-37SUB/F/OE/0,25/S/0,5M - 2926221 Assembled shielded round cable; connection 1: Single wires (37-position) (The wires are marked and fitted with ferrules. The braided shield is routed to a separate cable end.); connection 2: D-SUB socket strip (1x 37-position); cable length: 0.5 m     Cable - CABLE-D-37SUB/F/OE/0,25/S/1,0M - 2926234 Assembled shielded round cable; connection 1: Single wires (37-position) (The wires are marked and fitted with ferrules. The braided shield is routed to a separate cable end.); connection 2: D-SUB socket strip (1x 37-position); cable length: 1 m     Cable - CABLE-D-37SUB/F/OE/0,25/S/1,5M - 2926247 Assembled shielded round cable; connection 1: Single wires (37-position) (The wires are marked and fitted with ferrules. The braided shield is routed to a separate cable end.); connection 2: D-SUB socket strip (1x 37-position); cable length: 1.5 m     Cable - CABLE-D-37SUB/F/OE/0,25/S/2,0M - 2926250 Assembled shielded round cable; connection 1: Single wires (37-position) (The wires are marked and fitted with ferrules. The braided shield is routed to a separate cable end.); connection 2: D-SUB socket strip (1x 37-position); cable length: 2 m     Cable - CABLE-D-37SUB/F/OE/0,25/S/3,0M - 2926263 Assembled shielded round cable; connection 1: Single wires (37-position) (The wires are marked and fitted with ferrules. The braided shield is routed to a separate cable end.); connection 2: D-SUB socket strip (1x 37-position); cable length: 3 m     09/10/2019   Page 12 / 14 https://www.phoenixcontact.com/us/products/2924854 Module carrier - TC-D37SUB-ADIO16-EX-P-UNI - 2924854 Accessories Cable - CABLE-D-37SUB/F/OE/0,25/S/4,0M - 2926276 Assembled shielded round cable; connection 1: Single wires (37-position) (The wires are marked and fitted with ferrules. The braided shield is routed to a separate cable end.); connection 2: D-SUB socket strip (1x 37-position); cable length: 4 m     Cable - CABLE-D-37SUB/F/OE/0,25/S/6,0M - 2926289 Assembled shielded round cable; connection 1: Single wires (37-position) (The wires are marked and fitted with ferrules. The braided shield is routed to a separate cable end.); connection 2: D-SUB socket strip (1x 37-position); cable length: 6 m     Cable set - TC-C-MAX2-SC-32220000 - 2904446 Cable set for signal transmission and power supply on the Termination Carrier for signal conditioners from the MACX Analog Ex series. Connection of terminal points 3.2 and 2.2 (signal transmission for active input cards) to the signal PCB.     Additional products Label, highly flexible - EMLF (108XE)R - 0800549 Label, highly flexible, Roll, white, unlabeled, can be labeled with: THERMOMARK ROLLMASTER 300/600, THERMOMARK X1.2, THERMOMARK ROLL X1, THERMOMARK ROLL 2.0, THERMOMARK ROLL, mounting type: adhesive, lettering field size: 108 x 48000 mm, Number of individual labels: 1     Zack Marker strip, flat - ZBF 15:UNBEDRUCKT - 0811202 Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type: snap into flat marker groove, for terminal block width: 15 mm, lettering field size: 15 x 5.2 mm, Number of individual labels: 5     09/10/2019   Page 13 / 14 https://www.phoenixcontact.com/us/products/2924854 Phoenix Contact 2019 © - all rights reserved http://www.phoenixcontact.com 09/10/2019   Page 14 / 14
2924854 价格&库存

很抱歉,暂时无法提供与“2924854”相匹配的价格&库存,您可以联系我们找货

免费人工找货