    Module 24VDC Supply 8A 110 ~ 433 V Load

  • 详情介绍
  • 数据手册
  • 价格&库存
2963514 数据手册
ELR W 3/x-... MM Electronic Reversing-Load Relay With Motor Management Data Sheet 01/2005 Features Electronic load relays with motor management (ELR-MM) combine fast, wear-resistant, semiconductor switches and modern measurement and evaluation electronics. The active-power input of electrical drives is calculated every 6.6 ms from three currents, voltages, and the phase angle. This enables continuous status monitoring. Freely parameterizable signaling and switching thresholds for detecting under/overloads provide functions that far exceed standard motor protection. All relevant electrical values such as apparent power, active power, reactive power, currents, voltages, and phase angles, as well as the values of the internal cycle counter and elapsed-time meter can be requested via the display. Actuators and variable-speed drives, pumps, and tools are switched using the ELR-MM load relay and at the same time monitored and protected against dirt or wear. As an option, the devices can be coupled to fieldbus systems via a defined interface for online monitoring. Technical Data Input Data Operating voltage UB Maximum current consumption Control voltage right/left Input current right/left Input wiring ELR W 3/9-400 MM ELR W 3/2-400 MM ELR W 3/9-500 MM 24 V DC ±20% 80 mA 24 V DC ±20% 7 mA 5 mA 7 mA LED, diode for protection against polarity reversal, surge protection Output Data Confirmation Contacts O1 - O4 With 1 signal UB - 1 V/50 mA, maximum Output Data Load Side Operating voltage (conductor voltage) 50 Hz/60 Hz Reverse voltage Load current (see derating curve on page 2) 102149_00_en ELR W 3/9-400 MM ELR W 3/2-400 MM ELR W 3/9-500 MM 110 V AC 110 V AC - 550 V AC 435 V AC 1000 V 1500 V 3x8A 3 x 1.8 A 3x8A (100% operating (100% operating (100% operating factor) factor) factor) 1 ELR W 3/x-... MM Output Data Load Side (Continued) Load current depending on the ambient operating temperature ELR W 3/9-400 MM ELR W 3/2-400 MM ELR W 3/9-500 MM Load current [A] Operating time: 100% operating factor Surge current Minimum load current Residual voltage at IN Residual current in the OFF state Reversing frequency right rotation/left rotation (cos ϕ = 0.5) Shutdown time when overload or underload occurs Output wiring General Data Housing dimensions (length x width x height) Insulating housing version Test voltage I/O Ambient operating temperature range Standards/specifications Safe isolation input/output Degree of protection according to IEC 60529/EN 60529/DIN VDE 0470-1 Mounting position Mounting 2 Ambient operating temperature [°C] Figure 1 Load current depending on the ambient operating temperature 360 A (t = 10 ms) 150 mA 1.4 V, typical 4 mA, typical 2.5 Hz, maximum 45 ms, typical (worst case 70 ms) RCV circuit 94 mm x 62 mm x 122 mm (3.701 x 2.441 x 4.803 in.) Polycarbonate (PC), color: green 2.5 kVrms -20°C to +60°C (-4°F to +140°F) EN 61000-4-2/DIN EN 61000-4-2/VDE 0847-4-2; EN 61000-4-3/DIN EN 61000-4-3/VDE 0847-4-3; EN 61000-4-4/DIN EN 61000-4-4/VDE 0847-4-4; EN 61000-4-5/DIN EN 61000-4-5/VDE 0847-4-5; EN 61000-4-6/DIN EN 61000-4-6/VDE 0847-4-6; IEC 60664/IEC 60664 A/DIN VDE 0110 DIN EN 50178 (VDE 0160) IP20 Vertical (DIN rail horizontal) Can be mounted with spacing ≥ 20 mm (0.787 in.) 102149_00_en ELR W 3/x-... MM Connection Data Figure 2 Connection data The following cable cross sections can be connected: Solid [mm2] 0.2 - 6 Stranded [mm2] 0.2 - 4 AWG 25 - 10 Stripping Length L [mm] 8 mm (0.31 in.) Block Diagram Parameterization 24 V DC Logic µP Confirmation 24 V DC Memory 24 V DC V.24 Alarm Figure 3 102149_00_en Serial (RS-232) Block diagram 3 ELR W 3/x-... MM Ordering Data Description Electronic reversing-load relay with motor management. Order Designation Order No. ELR W 3/9-400 MM 29 63 51 4 ELR W 3/2-500 MM 29 82 62 1 ELR W 3/9-500 MM 29 63 54 3 For marking systems and assembly material, see CLIPLINE catalog. © PHOENIX CONTACT 01/2005 Technical modifications reserved Make sure you always use the latest documentation. It can be downloaded from www.download.phoenixcontact.com. PHOENIX CONTACT GmbH & Co. KG Flachsmarktstr. 8 32825 Blomberg Germany +49 - 52 35 - 30 0 +49 - 52 35 - 34 12 00 www.phoenixcontact.com Worldwide Locations: www.phoenixcontact.com/salesnetwork 4 102149_00_en
2963514
物料型号:ELR W3/9-400 MM、ELR W3/2-400 MM、ELR W3/9-500 MM。

器件简介:电子负载继电器结合了快速、耐用的半导体开关和现代测量评估电子技术,能够每6.6毫秒计算一次电动机驱动的有功功率输入,实现连续状态监控。

引脚分配:文档提供了详细的连接数据,包括M3螺钉和电缆横截面积。

参数特性:包括工作电压、最大电流消耗、控制电压、输入电流、输出数据确认接触点、负载侧操作电压、反向电压、负载电流等。

功能详解:继电器可以监测和保护执行器、变速驱动器、泵和工具免受污垢或磨损的影响,并且可以作为选项通过定义的接口连接到现场总线系统进行在线监控。

应用信息:适用于需要电机管理和保护的应用场景。

封装信息:包括外壳尺寸、绝缘材料、测试电压、环境工作温度范围、标准/规格、安全隔离输入/输出、防护等级、安装位置和方式等。
2963514 价格&库存

很抱歉,暂时无法提供与“2963514”相匹配的价格&库存,您可以联系我们找货

免费人工找货