https://www.phoenixcontact.com/us/products/2963721
Safety relays - PSR-SCP- 24UC/THC4/2X1/1X2 - 2963721
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Safety relay for two-hand control devices according to EN 574 type IIIC up to SIL 3 or Cat. 4, PL e according to
EN ISO 13849, synchronous activation monitoring < 0.5 s, 2 N/O contacts, 1 N/C contact, safe isolation, plug-in
screw terminal blocks, width: 22.5 mm
Product Features
■
■
■
■
■
■
For two-hand control devices according to EN 574 Type IIIC
Up to Cat. 4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508
Two-channel control
Synchronous activation monitoring < 0.5 s
Automatic activation
Two enabling and one signaling current path
Key Commercial Data
Packing unit
1 pc
Weight per Piece (excluding packing)
245.1 g
Custom tariff number
85371099
Country of origin
Germany
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
22.5 mm
Height
99 mm
Depth
114.5 mm
04/11/2016 Page 1 / 6
https://www.phoenixcontact.com/us/products/2963721
Safety relays - PSR-SCP- 24UC/THC4/2X1/1X2 - 2963721
Technical data
Ambient conditions
Ambient temperature (operation)
-20 °C ... 55 °C
Ambient temperature (storage/transport)
-40 °C ... 70 °C
Max. permissible relative humidity (operation)
75 % (on average, 85% infrequently, non-condensing)
Max. permissible humidity (storage/transport)
75 % (on average, 85% infrequently, non-condensing)
Shock
15g
Vibration (operation)
10 Hz ...150 Hz, 2g
Maximum altitude
max. 2000 m (Above sea level)
Input data
Nominal input voltage UN
24 V AC/DC
Input voltage range in reference to UN
0.85 ... 1.1
Typical input current at UN
125 mA AC
60 mA DC
Voltage at input/start and feedback circuit
approx. 24 V DC
Typical response time
50 ms
Typical release time
20 ms
Concurrence input 1/2
< 0.5 s
Recovery time
1s
Status display
Green LED
Output data
Contact type
2 enabling current paths
1 signaling current path
Contact material
AgSnO2, + 0.2 µm Au
Minimum switching voltage
15 V AC/DC
Maximum switching voltage
250 V AC/DC
Limiting continuous current
6A
Inrush current, minimum
25 mA
Maximum inrush current
6A
Interrupting rating (ohmic load) max.
144 W (24 V DC, τ = 0 ms)
288 W (48 V DC, τ = 0 ms)
110 W (110 V DC, τ = 0 ms)
88 W (220 V DC, τ = 0 ms)
1500 VA (250 V AC, τ = 0 ms)
Maximum interrupting rating (inductive load)
42 W (24 V DC, τ = 40 ms)
42 W (48 V DC, τ = 40 ms)
42 W (110 V DC, τ = 40 ms)
42 W (220 V DC, τ = 40 ms)
04/11/2016 Page 2 / 6
https://www.phoenixcontact.com/us/products/2963721
Safety relays - PSR-SCP- 24UC/THC4/2X1/1X2 - 2963721
Technical data
Output data
Switching capacity min.
0.4 W
Output fuse
10 A gL/gG NEOZED (N/O contact)
6 A gL/gG NEOZED (N/C contact)
General
Relay type
Electromechanical relay with forcibly guided contacts in accordance with
EN 50205
Mechanical service life
Approx. 10 cycles
Net weight
193.3 g
Mounting type
DIN rail mounting
Degree of protection
IP54
7
IP20
Min. degree of protection of inst. location
IP54
Mounting position
any
Connection data
Connection method
Screw connection
pluggable
Yes
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
12
Stripping length
7 mm
Screw thread
M3
Safety-related characteristic data
Stop category
0
Designation
IEC 61508 - High demand
Safety Integrity Level (SIL)
3
Designation
IEC 61508 - Low demand
Safety Integrity Level (SIL)
3
Designation
EN ISO 13849
Performance level (PL)
e
Category
4
Designation
EN 62061
Safety Integrity Level Claim Limit (SIL CL)
3
Standards and Regulations
04/11/2016 Page 3 / 6
https://www.phoenixcontact.com/us/products/2963721
Safety relays - PSR-SCP- 24UC/THC4/2X1/1X2 - 2963721
Technical data
Standards and Regulations
Shock
15g
Designation
Air clearances and creepage distances between the power circuits
Standards/regulations
DIN EN 50178/VDE 0160
Rated insulation voltage
250 V
Rated surge voltage/insulation
6 kV / Safe isolation, increased insulation
Degree of pollution
2
Overvoltage category
III
Vibration (operation)
10 Hz ...150 Hz, 2g
Classifications
eCl@ss
eCl@ss 4.0
27371102
eCl@ss 4.1
27371102
eCl@ss 5.0
27371901
eCl@ss 5.1
27371901
eCl@ss 6.0
27371819
eCl@ss 7.0
27371819
eCl@ss 8.0
27371821
ETIM
ETIM 2.0
EC000196
ETIM 3.0
EC001449
ETIM 4.0
EC001449
ETIM 5.0
EC001452
UNSPSC
UNSPSC 6.01
30211901
UNSPSC 7.0901
39121501
UNSPSC 11
39121501
UNSPSC 12.01
39121501
UNSPSC 13.2
39121501
Approvals
Approvals
04/11/2016 Page 4 / 6
https://www.phoenixcontact.com/us/products/2963721
Safety relays - PSR-SCP- 24UC/THC4/2X1/1X2 - 2963721
Approvals
Approvals
UL Listed / cUL Listed / Functional Safety / EAC / EAC / cUL Listed / Functional Safety / Functional Safety / Functional Safety / cULus Listed
Ex Approvals
Approvals submitted
Approval details
UL Listed
cUL Listed
Functional Safety
EAC
EAC
cUL Listed
Functional Safety
Functional Safety
Functional Safety
cULus Listed
04/11/2016 Page 5 / 6
https://www.phoenixcontact.com/us/products/2963721
Safety relays - PSR-SCP- 24UC/THC4/2X1/1X2 - 2963721
Drawings
Circuit diagram
A1
Y1
»
S11
13
23
31
14
24
32
K1
=
Logic
A2
S21
K2
S14/ S12/
S22 S24
Y2
Circuit diagram
L+
(L1)
Two-hand control switch
S1
S2
S11 S14 S12
A1
S11
(+)
S14
S22
( )
S21 S24 S22
S12 S21
S24 (GND)
( )
13
23
31
K3
14
24
32
K4
PSR-THC4/2x1/1x2
A2
(+)
Y1
( )
Y2
K3
M
K3
K4
K4
M
(N)
Two-hand control device
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com