ELR W 3/9-400 ELR W 3/9-500 Electronic Reversing-Load Relay for 3-Phase Networks Data Sheet m 01/2005 co Features ELR W 3/9... ELR W 3/9... electronic reversing-load relays are the practical and user-friendly further development of electronic load relays for 3-phase networks. The ELR W 3/9... is the fully electronic alternative to mechanical contactors. It features a compact design and low control power. A further advantage is the highquality, safe screw connection technology. om po nt ne These components feature high switching frequencies, virtually unlimited service life, no spark interference, and completely silent switching at zero voltage crossing. The compact, DIN rail-mountable modules meet all the requirements of an electronic reversing contactor circuit that has been designed specifically for industrial applications. Both the interlocking of control inputs and the complete wiring of the load contacts are incorporated in the device. Costly locking switches and contact wiring are thus a thing of the past. s. Electronic Reversing-Load Relay In accordance with DIN VDE 0110 and DIN VDE 0636, a conductor cross section of 1.5 mm2 (16 AWG), which must be fitted with one fuse each (10 A slow-blow as mains protection), is required to connect the electronic load relay to the 3-phase network. in ec Cabling has been reduced to an absolute minimum. Only the following must be applied: – Control voltage, supply voltage input and output – 3-phase load on l The status is clearly indicated by separate LEDs for "right rotation", "left rotation", "operating voltage" or "impermissible control". A short circuit between two phases at the moment of switching is prevented by the integrated delay between the control pulse and the load control. RCV protective circuits on the output side reduce voltage peaks that occur in the load circuit to a safe level and prevent damage to the output electronics. 5104778_03_en 1 ELR W 3/9-400/ELR W 3/9-500 Technical Data co LED, diode for protection against polarity reversal, surge protection The operating voltage and control voltage inputs must be operated with power supply modules according to DIN 19240 (maximum 5% residual ripple). To prevent the inductive or capacitive coupling of disturbing pulses in long control cables, we recommend the use of shielded cables. ne ELR W 3/9-400 400 V AC ELR W 3/9-500 500 V AC 110 V AC - 440 V AC 110 V AC - 550 V AC 1000 V 1200 V 3x9A om po Output Data (Output) Operating voltage (conductor voltage) 50 Hz/60 Hz Operating voltage range Reverse voltage Maximum continuous load current Load current depending on the ambient operating temperature nt s. 1 ELR W 3/9-400 ELR W 3/9-500 24 V DC +25%; -20%1 40 mA 24 V DC +25%; -20%1 6 mA, approximately 20 ms m Input Data (Input) Operating voltage UB Maximum current consumption Control voltage right/left Input current right/left Right rotation/left rotation switchover time (switch-on time) Input wiring Load current [A] on l in ec Operating time: 100% operating factor Ambient operating temperature [°C] Figure 1 2 Load current depending on the ambient operating temperature 5104778_03_en ELR W 3/9-400/ELR W 3/9-500 Output Data (Output) (Continued) Power dissipation depending on the load current ELR W 3/9-400 ELR W 3/9-500 m co s. Power dissipation [W] Operating time: 100% operating factor om nt ne po Surge current Minimum load current Residual voltage at IN Residual current in the OFF state Reversing frequency right rotation/left rotation (cos ϕ = 0.5) Output wiring on l in ec General Data Housing dimensions (length x width x height) Insulating housing version Test voltage I/O Ambient operating temperature range Standards/specifications Degree of protection according to IEC 60529/EN 60529/DIN VDE 0470-1 Mounting position Mounting 5104778_03_en 1.5 4.5 7.5 Current per phase [A] Figure 2 Power dissipation depending on the load current 230 A (t = 10 ms) 150 mA 1.7 V, typical 6 mA, typical 10 Hz, maximum RCV circuit, red LED (error message) 84 mm x 62 mm x 110 mm (3.307 x 2.441 x 4.331 in.) Polycarbonate (PC), color: green 2.5 kVrms -20°C to +60°C (-4°F to +140°F) EN 61000-4-4/DIN EN 61000-4-4/VDE 0847-4-4; EN 61000-4-5/DIN EN 61000-4-5/VDE 0847-4-5; IEC 60664/IEC 60664 A/DIN VDE 0110, basic insulation IP20 Vertical (DIN rail horizontal) Can be mounted with spacing ≥ 20 mm (0.787 in.) 3 ELR W 3/9-400/ELR W 3/9-500 Connection Data Figure 3 Connection data AWG Stripping Length L [mm] 25 - 10 8 mm (0.31 in.) co Stranded [mm2] 0.2 - 4 s. Solid [mm2] 0.2 - 6 m The following cable cross sections can be connected: in ec 24 V "left" 24 V "right" om po ne nt Block diagram Figure 4 4 on l Alarm Block diagram 5104778_03_en ELR W 3/9-400/ELR W 3/9-500 Ordering Data Description Order Designation Order No. Electronic reversing-load relay for directly controlling devices in a 3-phase network, with LED and protective circuit. ELR W 3/9-400 29 64 17 3 ELR W 3/9-500 29 64 18 6 co on l in ec © PHOENIX CONTACT 01/2005 Technical modifications reserved om po ne nt s. Make sure you always use the latest documentation. It can be downloaded from www.download.phoenixcontact.com. m For marking systems and assembly material, see CLIPLINE catalog. PHOENIX CONTACT GmbH & Co. KG Flachsmarktstr. 8 32825 Blomberg Germany +49 - 52 35 - 30 0 +49 - 52 35 - 34 12 00 www.phoenixcontact.com Worldwide Locations: www.phoenixcontact.com/salesnetwork 5 5104778_03_en
2964173 价格&库存

很抱歉,暂时无法提供与“2964173”相匹配的价格&库存,您可以联系我们找货

免费人工找货