PLC-OS…/300DC/1
PLC INTERFACE With Integrated Solid-State Relay
INTERFACE
Data Sheet
102491_en_04
1
© PHOENIX CONTACT 2010-12-22
Description
The 6.2 mm PLC-OS…/300DC/1 PLC INTERFACE module
with screw or spring-cage connection has an integrated
solid-state relay.
1.1
Input Voltages From 5 V to 230 V
PLC-OS…/300DC/1 is available on the control side in all
common industrial voltages from 5 V to 230 V. A further
advantage is the ready-integrated input circuit. It consists of
a status indicator and polarity reversal protection function,
and ensures that the operating state is displayed clearly,
also preventing destruction of the optical electronics should
the polarity be accidentally reversed.
1.2
Plug-In Bridges Save Wiring
The PLC INTERFACE module achieves maximum
efficiency with the user-friendly FBST plug-in bridge system.
PLC-OS…/300DC/1 makes effective use of the bridging
options for the A1/A2 connection on the control side and for
the supply at connection 13 on the load side. Especially
efficient here are the 500 mm long color-insulated
continuous plug-in bridges that can easily be cut to the
required length and quickly inserted in the bridge shafts.
They eliminate the need for complicated and timeconsuming loop bridges.
1.3
–
–
–
–
–
Additional Advantages
Switching power of up to 300 V DC/1 A
Wear-resistant switching
Integrated protective circuit
Resistant to vibrations and shocks
4 kVrms electrical isolation between input and output
Make sure you always use the latest documentation.
It can be downloaded at www.phoenixcontact.net/download.
This data sheet is valid for all products listed on the following page:
PLC-OS…/300DC/1
2
Ordering Data
PLC INTERFACE With Screw Connection, Housing Open on One Side
Description
Type
Order No.
PLC INTERFACE with integrated solid-state relay
5 V DC PLC-OSC-5DC/300DC/1
2980652
10
PLC INTERFACE with integrated solid-state relay
12 V DC PLC-OSC-12DC/300DC/1
2980665
10
Pcs./Pck.
PLC INTERFACE with integrated solid-state relay
24 V DC PLC-OSC-24DC/300DC/1
2980678
10
PLC INTERFACE with integrated solid-state relay
48 V DC ... 60 V DC PLC-OSC-60DC/300DC/1
2980681
10
PLC INTERFACE with integrated solid-state relay
110 V DC PLC-OSC-110DC/300DC/1
2980694
10
PLC INTERFACE with integrated solid-state relay
125 V DC PLC-OSC-125DC/300DC/1
2982210
10
PLC INTERFACE with integrated solid-state relay
220 V DC PLC-OSC-220DC/300DC/1
2980704
10
PLC INTERFACE with integrated solid-state relay
120 V AC PLC-OSC-120AC/300DC/1
2980717
10
PLC INTERFACE with integrated solid-state relay
230 V AC1 PLC-OSC-230AC/300DC/1
2980720
10
PLC INTERFACE With Spring-Cage Connection, Housing Open on One Side
Description
Type
Order No.
Pcs./Pck.
PLC INTERFACE with integrated solid-state relay
5 V DC PLC-OSP-5DC/300DC/1
2980814
10
PLC INTERFACE with integrated solid-state relay
12 V DC PLC-OSP-12DC/300DC/1
2980827
10
PLC INTERFACE with integrated solid-state relay
24 V DC PLC-OSP-24DC/300DC/1
2980830
10
PLC INTERFACE with integrated solid-state relay
48 V DC ... 60 V DC PLC-OSP-60DC/300DC/1
2980843
10
PLC INTERFACE with integrated solid-state relay
110 V DC PLC-OSP-110DC/300DC/1
2980856
10
PLC INTERFACE with integrated solid-state relay
125 V DC PLC-OSP-125DC/300DC/1
2982223
10
PLC INTERFACE with integrated solid-state relay
220 V DC PLC-OSP-220DC/300DC/1
2980869
10
PLC INTERFACE with integrated solid-state relay
120 V AC PLC-OSP-120AC/300DC/1
2980872
10
PLC INTERFACE with integrated solid-state relay
230 V AC1 PLC-OSP-230AC/300DC/1
2980885
10
1
The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules
(see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging.
For the protection of input and output, inductive loads must be dampened with an effective protective circuit.
Accessories
Description
Type
Order No.
Pcs./Pck.
Insulating plate
PLC-ATP BK
2966841
25
The PLC-ATP BK insulating plate should be used in the following cases: always fit at the start and end of a PLC terminal strip for voltages
greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules (FBST 8-PLC... or FBST 500... can be used for
potential bridging) and for safe isolation between adjacent modules.
For additional accessories such as power terminal blocks and plug-in bridges, please refer to the INTERFACE catalog or www.phoenixcontact.com.
102491_en_04
PHOENIX CONTACT
2
PLC-OS…/300DC/1
3
Technical Data
Input Data
Nominal input voltage1
DC
5 V DC
12 V DC
24 V DC
Permissible range (with reference to UN)
48 ... 60 V
DC
AC
110 V DC
125 V DC
220 V DC
120 V AC
230 V AC
0.8 ... 1.2 x UN
0.8 ... 1.1 x UN
1 signal ("H")
≥ 0.8 x UN
≥ 0.8 x UN
0 signal ("L")
≤ 0.4 x UN
Switching level
Typical input current at UN
≤ 0.4 x UN
5 mA
6 mA
8 mA
5 mA
5 mA
6 mA
3 mA
3 mA
3 mA
Typical response time at UN
800 µs
300 µs
300 µs
300 µs
400 µs
400 µs
400 µs
19 ms
19 ms
Typical release time at UN
1.5 ms
800 µs
700 µs
700 µs
700 µs
700 µs
1.4 ms
6 ms
Transmission frequency flimit
Input circuit
1
6 ms
50 Hz
50 Hz
Yellow LED, polarity protection, surge protection
Yellow LED,
surge protection,
bridge rectifier
The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules
(see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging.
Output Data
Nominal output voltage range1
12 V DC ... 300 V DC
Limiting continuous current
1 A (see "Derating Curve" on page 4)
Output configuration
2-wire floating
Output circuit
Protection against polarity reversal, surge protection
Voltage drop at maximum limiting continuous current
< 500 mV
1
The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules
(see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging.
General Data
Rated insulation voltage
300 V
Impulse voltage withstand level
4 kV, 50 Hz, 1 minute
Ambient temperature range
-20°C ... 60°C
Nominal operating mode
100% operating factor
Inflammability class according to UL 94 (housing)
V0
Air and creepage distances between the circuits1
DIN EN 50178 (basic insulation)
Pollution degree
2
Surge voltage category
III
Mounting position
Any
Assembly
Can be aligned without spacing
Conductor cross section
Screw connection
0.14 mm2 ... 2.5 mm2
Spring-cage connection
0.2 mm2 ... 2.5 mm2
Stripping length
8 mm
Dimensions (W x H x D)
6.2 mm x 86 mm x 80 mm
Housing material
Polybutylene terephthalate PBT non-reinforced, green
1
The PLC-ATP BK insulating plate must be installed for safe isolation between adjacent modules (see "Accessories"). FBST 8-PLC... or FBST 500... is
then used for potential bridging.
Tests/Approvals
CE
c
UL
Applied for
CUL
Applied for
GL
Applied for
102491_en_04
PHOENIX CONTACT
3
PLC-OS…/300DC/1
Block Diagram
5
A1
14
14
A2
13+
A2
13+
Derating Curve
Load current [A]
4
1
0,7
0
1
30
40
50
60
Ambient temperature [°C]
1 For input voltages of 220 V DC and 230 V AC
102491_en_04
PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49-(0) 5235-3-00
PHOENIX CONTACT • P.O.Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300
www.phoenixcontact.com