Coupling relay - PSR-SCP-120UC/URM/5X1/2X2
2981402
https://www.phoenixcontact.com/us/products/2981402
Please be informed that the data shown in this PDF document is generated from our Online Catalog. Please find the complete data in the user
documentation. Our General Terms of Use for Downloads are valid.
Safe coupling relay with force-guided contacts, 5 N/O contacts, 2 N/C contacts, 1-channel, plugin screw terminal block, width: 22.5 mm
Your advantages
• Suitable up to category 1, PL c (EN ISO 13849-1), SIL 1 (EN 62061), SIL 1 (IEC 61508)
• Safe readback due to force-guided signal contact in accordance with EN 50205
• Easy proof test according to IEC 61508 thanks to integrated signal contact
• 1 or 2-channel control
• 5 enabling current paths, 2 confirmation current paths
• 120 V version
Commercial Data
Item number
2981402
Packing unit
1 pc
Minimum order quantity
1 pc
Sales Key
C18
Product Key
DNA162
Catalog Page
Page 245 (C-6-2019)
GTIN
4017918944179
Weight per Piece (including packing)
177.03 g
Weight per Piece (excluding packing)
150.18 g
Customs tariff number
85364900
Country of origin
DE
Oct 27, 2022, 5:10 PM
Page 1 (9)
Coupling relay - PSR-SCP-120UC/URM/5X1/2X2
2981402
https://www.phoenixcontact.com/us/products/2981402
Technical Data
Product properties
Product type
Coupling relay
Application
Safe switch off
High demand
Low demand
Mechanical service life
10x 106 cycles
Relay type
Electromechanical relay with force-guided contacts in
accordance with IEC/EN 61810-3
Insulation characteristics
Overvoltage category
III
Times
Restart time
< 1 s (Boot time)
Electrical properties
Maximum power dissipation for nominal condition
8.8 W (at UB = 132 V DC, US = 120 V, IS = 11 mA, n = 1,
IL² = 72 A², Rcontact = 0.1 )
Nominal operating mode
100% operating factor
Rated insulation voltage
250 V
Rated insulation voltage
250 V
Rated surge voltage/insulation
4 kV basic insulation (4 kV safe isolation, reinforced insulation
between A1/A2, 13/14, 23/24, 33/34 to 43/44, 53/54, 61/62,
71/72)
Input data
General
Rated control circuit supply voltage US
120 V AC/DC -20 % ... +10 %
Power consumption at US
typ. 1.32 W
Rated control supply current IS
typ. 11 mA
Input voltage range
19.2 V AC/DC ... 26.4 V AC/DC
Inrush current
typ. 600 mA (Δt = 200 µs at Us)
Typ. starting time with Us
typ. 20 ms (when controlled via A1)
Typical release time
typ. 20 ms (when controlled via A1)
Recovery time
< 500 ms
Maximum switching frequency
0.5 Hz
Protective circuit
Surge protection; Varistor
Operating voltage display
1 x green LED
Output data
Contact type
5 enabling current paths
2 confirmation current paths
Contact material
AgSnO2
Oct 27, 2022, 5:10 PM
Page 2 (9)
Coupling relay - PSR-SCP-120UC/URM/5X1/2X2
2981402
https://www.phoenixcontact.com/us/products/2981402
Maximum switching voltage
230 V AC/DC (Observe the load curve)
Minimum switching voltage
5 V AC/DC
Limiting continuous current
6 A (N/O contact)
3 A (N/C contact)
Maximum inrush current
6A
Inrush current, minimum
10 mA
Sq. Total current
72 A2
Interrupting rating (ohmic load) max.
144 W (N/O contact, 24 V DC, τ = 0 ms)
288 W (N/O contact, 48 V DC, τ = 0 ms)
240 W (N/O contact, 60 V DC, τ = 0 ms)
110 W (N/O contact, 110 V DC, τ = 0 ms)
88 W (N/O contact, 220 V DC, τ = 0 ms)
1380 VA (N/O contact, 230 V AC, τ = 0 ms)
Maximum interrupting rating (inductive load)
42 W (N/O contact, 24 V DC, τ = 40 ms)
42 W (N/O contact, 48 V DC, τ = 40 ms)
42 W (N/O contact, 60 V DC, τ = 40 ms)
42 W (N/O contact, 110 V DC, τ = 40 ms)
42 W (N/O contact, 220 V DC, τ = 40 ms)
Switching capacity
min. 50 mW
Switching capacity according to IEC 60947-5-1
3 A (24 V (DC13))
3 A (230 V (AC 15))
Switching capacity (360/h cycles)
4 A (24 V (DC13))
4 A (230 V (AC15))
Output fuse
10 A gL/gG (N/O contact)
4 A gL/gG (N/O contact, for low-demand applications)
6 A gL/gG (N/C contact)
Connection data
Connection technology
pluggable
yes
Conductor connection
Connection method
Screw connection
Conductor cross section solid
0.2 mm² ... 2.5 mm²
Conductor cross section flexible
0.2 mm² ... 2.5 mm²
Conductor cross-section AWG
24 ... 12
Stripping length
7 mm
Screw thread
M3
Tightening torque
0.6 Nm
Dimensions
Width
22.5 mm
Height
114.5 mm
Depth
99 mm
Oct 27, 2022, 5:10 PM
Page 3 (9)
Coupling relay - PSR-SCP-120UC/URM/5X1/2X2
2981402
https://www.phoenixcontact.com/us/products/2981402
Material specifications
Housing material
Polyamide
Housing color
yellow
Characteristics
Safety data
Stop category
0
Safety data: EN ISO 13849
Category
1
Performance level (PL)
c
Safety data: IEC 61508 - High demand
Equipment type
Type A
Safety Integrity Level (SIL)
1
Probability of a hazardous failure per hour (PFHD)
1.00 x 10-7 (3 A AC15; 8760 switching cycles/year; 5 % of the
total SIL)
Proof test interval
240 Months
Duration of use
240 Months
Safety data: IEC 61508 - Low demand
Equipment type
Type A
Safety Integrity Level (SIL)
1
Probability of a hazardous failure on demand (PFDAVG)
4.05 x 10-3
Proof test interval
56 Months
Duration of use
240 Months
Environmental and real-life conditions
Ambient conditions
Degree of protection
IP20
Min. degree of protection of inst. location
IP54
Ambient temperature (operation)
-20 °C ... 55 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Maximum altitude
≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport)
75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation)
75 % (on average, 85% infrequently, non-condensing)
Shock
15g (In the event of stress caused by shock, contact reactions
are possible for up to 2 ms.)
Vibration (operation)
10 Hz ... 150 Hz, 2g (In the event of stress caused by vibration,
contact reactions are possible for up to 1 ms.)
Approval data
CE
Certificate
CE-compliant
Oct 27, 2022, 5:10 PM
Page 4 (9)
Coupling relay - PSR-SCP-120UC/URM/5X1/2X2
2981402
https://www.phoenixcontact.com/us/products/2981402
Standards and regulations
Air clearances and creepage distances between the power circuits
Standards/regulations
DIN EN 50178
Mounting
Mounting type
DIN rail mounting
Mounting position
vertical or horizontal
Oct 27, 2022, 5:10 PM
Page 5 (9)
Coupling relay - PSR-SCP-120UC/URM/5X1/2X2
2981402
https://www.phoenixcontact.com/us/products/2981402
Drawings
Application drawing
U1
0
1
2
3
4
5
6
7
A1
A2
13
14
A1
A2
13
14
23
24
33
34
23
24
33
34
Power
PSR-URM
STOP
RUN
STOP
MRES
0
1
2
3
4
5
6
7
PSR-URM
SF
BATF
DC5V
FRCE
RUN
RUN-P
Power
43
44
53
54
43
44
53
54
61
62
71
72
61
62
71
72
SF
BATF
DC5V
FRCE
RUN
RUN-P
STOP
RUN
STOP
MRES
U2
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
Reliable signal exchange between two systems with confirmation function.
Block diagram
13 23 33 43 53 61 71
PSR-URM/5x1/2x2
A1
A2
PWR
K1
120V UC
14 24 34 44 54 62 72
Block diagram
Oct 27, 2022, 5:10 PM
Page 6 (9)
Coupling relay - PSR-SCP-120UC/URM/5X1/2X2
2981402
https://www.phoenixcontact.com/us/products/2981402
Approvals
EAC
Approval ID: RU C-DE.A*30.B.01082
UL Listed
cUL Listed
Functional Safety
Functional Safety
Approval ID: FILE E 140324
Approval ID: FILE E 140324
Approval ID: 44-780-15124312
Approval ID: 44-205-15124312
cULus Listed
Oct 27, 2022, 5:10 PM
Page 7 (9)
Coupling relay - PSR-SCP-120UC/URM/5X1/2X2
2981402
https://www.phoenixcontact.com/us/products/2981402
Classifications
ECLASS
ECLASS-9.0
27371601
ECLASS-10.0.1
27371601
ECLASS-11.0
27371819
ETIM
ETIM 8.0
EC001449
UNSPSC
UNSPSC 21.0
39122200
Oct 27, 2022, 5:10 PM
Page 8 (9)
Coupling relay - PSR-SCP-120UC/URM/5X1/2X2
2981402
https://www.phoenixcontact.com/us/products/2981402
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the
manufacturer’s declaration available under “Downloads”
Phoenix Contact 2022 © - all rights reserved
https://www.phoenixcontact.com
Phoenix Contact USA
586 Fulling Mill Road
Middletown, PA 17057, United States
(+717) 944-1300
info@phoenixcon.com
Oct 27, 2022, 5:10 PM