Test adapter, Touch proof against unintentional direct contact according to DIN EN 50274 when
plugged in, for 4 mm test plug and terminal blocks with 8.2 mm pitch, color: green
Your advantages
• Make contact and latch securely to any point in the function shaft
• Test adapter for accommodating safety test plugs with a 4 mm diameter
Commercial Data
Item number
3032758
Packing unit
1 pc
Minimum order quantity
10 pc
Sales Key
B02
Product Key
BE2Z3X
Catalog Page
Page 116 (C-1-2019)
GTIN
4046356280334
Weight per Piece (including packing)
2.43 g
Weight per Piece (excluding packing)
2.3 g
Customs tariff number
85366990
Country of origin
PL
Dec 2, 2022, 5:13 PM
Page 1 (6)
Test adapter - PAI-4-FIX GN
3032758
https://www.phoenixcontact.com/us/products/3032758
Technical Data
Notes
General
Touch proof against unintentional direct contact according to DIN
EN 50274 when plugged in
General
Do not plug in while the power is connected
General
Latching testing accessories, therefore only suitable for being
plugged in once
Product properties
Product type
Test socket
Number of positions
1
Electrical properties
Maximum load current
10 A
Max. voltage
250 V
Connection data
Maximum load current
10 A
Dimensions
Width
5.8 mm
Height
51.5 mm
Length
5.8 mm
Diameter
5.8 mm
Pin diameter
2.4 mm
Material specifications
Color
green
Material
PA
Flammability rating according to UL 94
V0
Insulating material
PA
Static insulating material application in cold
-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE
0304-21))
130 °C
Relative insulation material temperature index (Elec., UL 746 B)
130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354)
28 MJ/kg
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Dec 2, 2022, 5:13 PM
Page 2 (6)
Test adapter - PAI-4-FIX GN
3032758
https://www.phoenixcontact.com/us/products/3032758
Mechanical properties
Mechanical data
Insertion/withdrawal cycles
1
Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)
-60 °C ... 105 °C (max. short-term operating temperature RTI
Elec.)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to
+70 °C)
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Permissible humidity (storage/transport)
30 % ... 70 %
Dec 2, 2022, 5:13 PM
Page 3 (6)
Test adapter - PAI-4-FIX GN
3032758
https://www.phoenixcontact.com/us/products/3032758
Approvals
EAC
Approval ID: RU C-DE.BL08.B.00511
Dec 2, 2022, 5:13 PM
Page 4 (6)
Test adapter - PAI-4-FIX GN
3032758
https://www.phoenixcontact.com/us/products/3032758
Classifications
ECLASS
ECLASS-9.0
27440313
ECLASS-10.0.1
27440313
ECLASS-11.0
27141148
ETIM
ETIM 8.0
EC002555
UNSPSC
UNSPSC 21.0
20122000
Dec 2, 2022, 5:13 PM
Page 5 (6)
Test adapter - PAI-4-FIX GN
3032758
https://www.phoenixcontact.com/us/products/3032758
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Phoenix Contact 2022 © - all rights reserved