  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    CONNTERMBLKDISCONN12-28AWG

  • 数据手册
  • 价格&库存
3038436 数据手册
https://www.phoenixcontact.com/us/products/3038436 Disconnect terminal block - ST 2,5-TG RD - 3038436 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Disconnect terminal block, Connection type: Spring-cage connection, Cross section: 0.08 mm² - 4 mm², AWG: 28 - 12, Nominal current: 20 A, Nominal voltage: 400 V, Length: 60.5 mm, Width: 5.2 mm, Color: red, Assembly: NS 35/7,5, NS 35/15 The illustration shows the gray version Key Commercial Data Packing unit 1 pc Minimum order quantity 50 pc Weight per Piece (excluding packing) 7.6 g Custom tariff number 85369010 Country of origin Germany Technical data General Number of levels 1 Number of connections 2 Nominal cross section 2.5 mm² Color red Insulating material PA Flammability rating according to UL 94 V0 Rated surge voltage 6 kV Degree of pollution 3 Overvoltage category III Insulating material group I Connection in acc. with standard IEC 60947-7-1 Nominal current IN 20 A (current is determined by the plug used) Maximum load current 20 A (with 4 mm² conductor cross section) 05/20/2016   Page 1 / 5 https://www.phoenixcontact.com/us/products/3038436 Disconnect terminal block - ST 2,5-TG RD - 3038436 Technical data General Nominal voltage UN 400 V (voltage is determined by the plug used) Open side panel Yes Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11 Back of the hand protection guaranteed Finger protection guaranteed Result of surge voltage test Test passed Surge voltage test setpoint 7.3 kV Result of power-frequency withstand voltage test Test passed Power frequency withstand voltage setpoint 1.89 kV Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed Result of bending test Test passed Bending test rotation speed 10 rpm Bending test turns 135 Bending test conductor cross section/weight 0.08 mm² / 0.1 kg 2.5 mm² / 0.7 kg 4 mm² / 0.9 kg Tensile test result Test passed Conductor cross section tensile test 0.08 mm² Tractive force setpoint 5N Conductor cross section tensile test 2.5 mm² Tractive force setpoint 50 N Conductor cross section tensile test 4 mm² Tractive force setpoint 60 N Result of tight fit on support Test passed Tight fit on carrier NS 35 Setpoint 1N Result of voltage-drop test Test passed Requirements, voltage drop ≤ 6,4 mV Result of temperature-rise test Test passed Short circuit stability result Test passed Conductor cross section short circuit testing 2.5 mm² Short-time current 0.3 kA Result of aging test Test passed Ageing test for screwless modular terminal block temperature cycles 192 Result of thermal test Test passed Proof of thermal characteristics (needle flame) effective duration 30 s 05/20/2016   Page 2 / 5 https://www.phoenixcontact.com/us/products/3038436 Disconnect terminal block - ST 2,5-TG RD - 3038436 Technical data General Oscillation, broadband noise test result Test passed Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03 Test spectrum Service life test category 2, bogie mounted Test frequency f1 = 5 Hz to f2 = 250 Hz ASD level 6.12 (m/s ) /Hz Acceleration 3.12 g Test duration per axis 5h Test directions X-, Y- and Z-axis Shock test result Test passed Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03 Shock form Half-sine Acceleration 30g Shock duration 18 ms Number of shocks per direction 3 Test directions X-, Y- and Z-axis (pos. and neg.) 2 2 Dimensions Width 5.2 mm Length 60.5 mm Height NS 35/7,5 36.5 mm Height NS 35/15 44 mm Connection data Conductor cross section solid min. 0.08 mm² Conductor cross section solid max. 4 mm² Conductor cross section flexible min. 0.08 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 28 Conductor cross section AWG max. 12 Conductor cross section flexible, with ferrule without plastic sleeve min. 0.14 mm² Conductor cross section flexible, with ferrule without plastic sleeve max. 2.5 mm² Conductor cross section flexible, with ferrule with plastic sleeve min. 0.14 mm² Conductor cross section flexible, with ferrule with plastic sleeve max. 2.5 mm² 2 conductors with same cross section, stranded, TWIN ferrules with plastic 0.5 mm² sleeve, max. Connection method Spring-cage connection Stripping length 8 mm ... 10 mm Internal cylindrical gage A3 05/20/2016   Page 3 / 5 https://www.phoenixcontact.com/us/products/3038436 Disconnect terminal block - ST 2,5-TG RD - 3038436 Technical data Standards and Regulations Connection in acc. with standard IEC 60947-7-1 Flammability rating according to UL 94 V0 Classifications eCl@ss eCl@ss 4.0 27141120 eCl@ss 4.1 27141120 eCl@ss 5.0 27141120 eCl@ss 5.1 27141120 eCl@ss 6.0 27141120 eCl@ss 7.0 27141126 eCl@ss 8.0 27141126 eCl@ss 9.0 27141126 ETIM ETIM 4.0 EC000897 ETIM 5.0 EC000902 UNSPSC UNSPSC 6.01 30211811 UNSPSC 7.0901 39121410 UNSPSC 11 39121410 UNSPSC 12.01 39121410 UNSPSC 13.2 39121410 Approvals Approvals Approvals EAC / RS Ex Approvals Approvals submitted 05/20/2016   Page 4 / 5 https://www.phoenixcontact.com/us/products/3038436 Disconnect terminal block - ST 2,5-TG RD - 3038436 Approvals Approval details EAC  RS  Drawings Circuit diagram Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 05/20/2016   Page 5 / 5
3038436 价格&库存

很抱歉,暂时无法提供与“3038436”相匹配的价格&库存,您可以联系我们找货

免费人工找货