0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3040368

3040368

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    TERM BLOCK PLUG 12POS STR

  • 数据手册
  • 价格&库存
3040368 数据手册
ST-COMBI Pluggable Spring Cage Terminal Blocks The base terminal blocks of the ST-COMBI series provide solutions for a wide variety of applications. The series includes feed-through terminal blocks with one or two connector entries, four-conductor terminal blocks with two or four connector entries and space-saving double-level terminal blocks also with two connector entries. The same accessories are used for the base terminal blocks as for the ST standard series. Ground terminal blocks with the same shape and the same pitch are available for the various base terminal blocks. Contact is made by simply snapping the terminal block onto the mounting rail. All the requirements of IEC 60 947-7-2 are fulfilled. ST-COMBI Plugs and ST-COMBI Receptacles As with the base terminal blocks, the plugs also offer the perfect solution for every application. The SP 2,5... plugs are designed for the connection of one conductor. The SPB 2,5... plug fulfills the same purpose but also provides an additional bridging facility. The SPDB 2,5... plug is designed for the connection of two conductors and also provides an additional bridging facility. With the receptacles SC 2,5/..., plug-in contacts can be safely accommodated in cable ducts and distributor shafts without using much space. The standard strain relief can also be used. Large-surface labeling makes it possible to clearly identify the plug connection. The integrated test connection makes it possible to test each contact point using a 2.3 mm test plug. Strain relief PZ/PDZ Strain reliefs are available for the plugs and can be snapped on at the required points as an option. The PZ... strain reliefs for SP... and SPB... plugs are snapped on externally. The PDZ... strain relief for the SPDB plug is snapped on at the plug center. Shield connection PSH PSH... provides a solution for the connection of shielded conductors. PSH... is snapped into PZ... or PRZ after the terminal blocks have been wired and is then permanently secured using a cable tie. The PSH connecting cable is connected to a connector conductor and makes contact directly with the terminal block when inserted. PC coding option Specific connector positions can be defined for all the base terminal blocks using the PC coding star. To do this, the individual branches of the coding star are inserted at the coding position in the base terminal block and the coding lug is removed at the corresponding point of the connector. PZ/PRZ snap-lock fitting The PR... snap-lock fitting can be used for all plug variants. It is snapped into the outside of the plug housing as an option and hooks onto the terminal block housing when the plug is snapped on. PRZ can be used when an application requires strain relief and a snaplock fitting. PRZ is also snapped into the plug housing as an option and offers a combination of snap fitting and strain relief in a single component. Phoenix Contact GmbH & Co. KG • 32823 Blomberg, Germany Phone +49 52 35 3-00 • Fax +49 52 35 3-4 12 00 • www.phoenixcontact.com Local Contact: www.phoenixcontact.com/salesnetwork Pluggable Spring Cage Terminal Blocks ST 2,5/ 1P (IEC) [mm2] Connection data rigid solid flexible stranded AWG I [A] U [V] 0.08-4 0.08-2.5 28-12 24 500 u Technical data Spring cage terminal block, for mounting on 3 gray blue (1) Cover terminal width 5.2 terminal width 5.2 gray (2) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections white Cross section range: 0.08-0.2 mm2 0.25-0.5 mm2 gray 2 black 0.75-1 mm (3) Plug-in bridge, for cross bridging in the terminal center 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. Type Order No. Pcs. Pkt. ST 2,5/ 1P ST 2,5/ 1P BU 30 40 01 2 30 40 65 6 50 50 D-ST 2,5 30 30 41 7 50 ISH 2,5/0,2 ISH 2,5/0,5 ISH 2,5/1 30 02 84 3 30 02 85 6 30 02 86 9 50 50 50 30 30 16 1 30 30 17 4 30 30 18 7 30 30 19 0 30 30 21 3 30 30 22 6 50 50 50 50 10 10 FBS 2-5 FBS 3-5 FBS 4-5 FBS 5-5 FBS 10-5 FBS 20-5 Imax.: 24 A 24 A 24 A 24 A 24 A 24 A (4) Partition plate, for visual and electrical separation of terminal groups, 2 mm thick ATP-ST 4 30 30 72 1 50 (5) Test adapter, for 4 mm ∅ PS test plug and 4 mm ∅ safety test plugs, makes contact in the bridge shaft PAI 4 30 30 92 5 10 MPS-RD 02 01 55 3 10 PS 5 30 30 98 3 10 PC 30 40 58 8 50 WST 2,5 30 30 94 1 50 SZF 1 - 0,6 x 3,5 12 04 51 7 10 (6) 2.3 mm ∅ test plug 1), consisting of metal part and red insulating sleeve (7) Modular test plug, labeling with ZBF 5 (8) Coding star, with 4 coding pins, for mounting in all base terminal blocks (9) Warning cover, for the actuating ducts of the "mini-spring" ST spring cage terminal blocks (10) Screwdriver, for actuating the tension spring (11) Zack strip, flat, for labeling the center and outer marker grooves white ZBF 5:UNPRINTED 08 08 64 2 10 (12) Zack strip, 10-section, for labeling in the terminal center white ZB 5:UNPRINTED 10 50 00 4 10 Dimensions Width / length / end cover width [mm] Height (NS 35/7,5 / NS 35/15) [mm] Technical data in accordance with IEC / DIN VDE Maximum // Rated data [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V]/[A]/AWG CSA/CUL: [V] / [A] / AWG 1 ) Further colors on request. Phoenix Contact page 2 of 27 5.2 / 48.5 / 2.2 36.5 / 44 24 / 4 // 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 10 A3 PA V0 600 / 20 / 26-12 600 / 20 / 26-12 Pluggable Spring Cage Terminal Blocks ST 2,5-TWIN/ 1P (IEC) [mm2] rigid solid flexible stranded AWG I [A] U [V] Connection data 0.08-4 0.08-2.5 28-12 24* 500 * The max. load current must not be exceeded by the total current of all connected conductors. Technical data Spring cage terminal block, for mounting on 3 gray blue (1) Cover terminal width 5.2 terminal width 5.2 gray (2) Cover segment, serves for gray covering multi-conductor terminal blocks when two-conductor terminal blocks are aligned (3) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.08-0.2 mm2 white gray 0.25-0.5 mm2 0.75-1 mm2 black (4) Plug-in bridge, for cross bridging in the terminal center 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. Type Order No. Pcs. Pkt. ST 2,5-TWIN/ 1P ST 2,5-TWIN/ 1P BU 30 42 11 7 30 42 10 4 50 50 D-ST 2,5-TWIN 30 30 48 8 50 DS-ST 2,5 30 36 60 2 50 ISH 2,5/0,2 ISH 2,5/0,5 ISH 2,5/1 30 02 84 3 30 02 85 6 30 02 86 9 50 50 50 30 30 16 1 30 30 17 4 30 30 18 7 30 30 19 0 30 30 21 3 30 30 22 6 50 50 50 50 10 10 FBS 2-5 FBS 3-5 FBS 4-5 FBS 5-5 FBS 10-5 FBS 20-5 Imax.: 24 A 24 A 24 A 24 A 24 A 24 A (5) Partition plate, for visual and electrical separation of terminal groups, 2 mm thick ATP-ST-TWIN 30 30 78 9 50 (6) Test adapter, for 4 mm ∅ PS test plug and 4 mm ∅ safety test plugs, makes contact in the bridge shaft PAI 4 30 30 92 5 10 MPS-RD 02 01 55 3 10 PS 5 30 30 98 3 10 PC 30 40 58 8 50 WST 2,5 30 30 94 1 50 (7) 2.3 mm ∅ test plug 1), consisting of metal part and red insulating sleeve (8) Modular test plug, labeling with ZBF 5 (9) Coding star, with 4 coding pins, for mounting in all base terminal blocks (10) Warning cover, for the actuating ducts of the "mini-spring" ST spring cage terminal blocks (11) Screwdriver, for actuating the tension spring SZF 1 - 0,6 x 3,5 12 04 51 7 10 (12) Zack strip, flat, for center and external labeling, white ZBF 5:UNPRINTED 08 08 64 2 10 (13) Zack strip, 10-section, for center labeling, white ZB 5:UNPRINTED 10 50 00 4 10 Dimensions Width / length / end cover width [mm] Height (NS 35/7,5 / NS 35/15) [mm] Technical data in accordance with IEC / DIN VDE Maximum // Rated data [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG 1 ) Further colors on request. Phoenix Contact page 3 of 27 5.2 / 60.5 / 2.2 36.5 / 44 24 / 4 // – 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 10 A3 PA V0 applied for applied for Pluggable Spring Cage Terminal Blocks ST 2,5-QUATTRO/ 2P (IEC) [mm2] rigid solid flexible stranded AWG I [A] U [V] Connection data 0.08-4 0.08-2.5 28-12 24* 500 * The max. load current must not be exceeded by the total current of all connected conductors. u Technical data Spring cage terminal block, for mounting on 3 gray blue (1) Cover terminal width 5.2 terminal width 5.2 gray (2) Cover segment, serves for gray covering multi-conductor terminal blocks when two-conductor terminal blocks are aligned (3) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.08-0.2 mm2 white gray 0.25-0.5 mm2 0.75-1 mm2 black (4) Plug-in bridge, for cross bridging in the terminal center 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. Type Order No. Pcs. Pkt. ST 2,5-QUATTRO/ 2P ST 2,5-QUATTRO/ 2P BU 30 40 03 8 30 40 66 9 50 50 D-ST 2,5-QUATTRO/ 2P 30 40 08 3 50 DS-ST 2,5/P 30 41 01 1 50 ISH 2,5/0,2 ISH 2,5/0,5 ISH 2,5/1 30 02 84 3 30 02 85 6 30 02 86 9 50 50 50 30 30 16 1 30 30 17 4 30 30 18 7 30 30 19 0 30 30 21 3 30 30 22 6 50 50 50 50 10 10 FBS 2-5 FBS 3-5 FBS 4-5 FBS 5-5 FBS 10-5 FBS 20-5 Imax.: 24 A 24 A 24 A 24 A 24 A 24 A (5) Partition plate, for visual and electrical separation of terminal groups, 2 mm thick ATP-ST QUATTRO 30 30 81 5 50 (6) Test adapter, for 4 mm ∅ PS test plug and 4 mm ∅ safety test plugs, makes contact in the bridge shaft PAI 4 30 30 92 5 10 MPS-RD 02 01 55 3 10 PS 5 30 30 98 3 10 PC 30 40 58 8 50 WST 2,5 30 30 94 1 50 SZF 1 - 0,6 x 3,5 12 04 51 7 10 (7) 2.3 mm ∅ test plug 1), consisting of metal part and red insulating sleeve (8) Modular test plug, labeling with ZBF 5 (9) Coding star, with 4 coding pins, for mounting in all base terminal blocks (10) Warning cover, for the actuating ducts of the "mini-spring" ST spring cage terminal blocks (11) Screwdriver, for actuating the tension spring (12) Zack strip, flat, for center and external labeling , white ZBF 5:UNPRINTED 08 08 64 2 10 (13) Zack strip, 10-section, for center labeling, white ZB 5:UNPRINTED 10 50 00 4 10 Dimensions Width / length / end cover width [mm] Height (NS 35/7,5 / NS 35/15) [mm] Technical data in accordance with IEC / DIN VDE Maximum // Rated data [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG 1) Further colors on request. Phoenix Contact page 4 of 27 5.2 / 81 / 2.2 36.5 / 44 24 / 4 // – 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 10 A3 PA V0 600 / 20 / 26-12 600 / 20 / 26-12 Pluggable Spring Cage Terminal Blocks STTB 2,5/ 2P (IEC) [mm2] Connection data rigid solid flexible stranded AWG I [A] U [V] 0.08-4 0.08-2.5 28-12 24 500 u Technical data Spring cage terminal block, for mounting on 3 gray blue (1) Cover terminal width 5.2 terminal width 5.2 gray (2) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.08-0.2 mm2 white gray 0.25-0.5 mm2 2 black 0.75-1 mm (3) Plug-in bridge, for cross bridging in the terminal center 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. Type Order No. Pcs. Pkt. STTB 2,5/ 2P STTB 2,5/ 2P BU 30 40 05 4 30 40 67 2 50 50 D-STTB 2,5/ 2P 30 40 09 6 50 ISH 2,5/0,2 ISH 2,5/0,5 ISH 2,5/1 30 02 84 3 30 02 85 6 30 02 86 9 50 50 50 30 30 16 1 30 30 17 4 30 30 18 7 30 30 19 0 30 30 21 3 30 30 22 6 50 50 50 50 10 10 FBS 2-5 FBS 3-5 FBS 4-5 FBS 5-5 FBS 10-5 FBS 20-5 Imax.: 24 A 24 A 24 A 24 A 24 A 24 A (4) Partition plate, for visual and electrical separation of terminal groups, 2 mm thick ATP-STTB 4 30 30 74 7 50 (5) Test adapter, for 4 mm ∅ PS test plug and 4 mm ∅ safety test plugs, makes contact in the bridge shaft PAI 4 30 30 92 5 10 MPS-RD 02 01 55 3 10 PS 5 30 30 98 3 10 PC 30 40 58 8 50 WST 2,5 30 30 94 1 50 SZF 1 - 0,6 x 3,5 12 04 51 7 10 ZBF 5:UNPRINTED 08 08 64 2 10 (6) 2.3 mm ∅ test plug 1), consisting of metal part and red insulating sleeve (7) Modular test plug, labeling with ZBF 5 (8) Coding star, with 4 coding pins, for mounting in all base terminal blocks (9) Warning cover, for the actuating ducts of the "mini-spring" ST spring cage terminal blocks (10) Screwdriver, for actuating the tension spring (11) Zack strip, flat, for labeling the outer marker grooves white Dimensions Width / length / end cover width [mm] Height (NS 35/7,5 / NS 35/15) [mm] Technical data in accordance with IEC / DIN VDE Maximum // Rated data [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG 1 ) Further colors on request. Phoenix Contact page 5 of 27 5.2 / 71.5 / 2.2 47.5 / 55 24 / 4 // 20 / 2.5 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 10 A3 PA V0 600 / 20 / 26-12 600 / 20 / 26-12 Pluggable Spring Cage Terminal Blocks STTB 2,5/ 2P-PV (IEC) [mm2] rigid solid flexible stranded AWG I [A] U [V] Connection data 0.08-4 0.08-2.5 28-12 24* 500 * The max. load current must not be exceeded by the total current of all connected conductors. u Technical data Spring cage terminal block, for mounting on 3 gray blue (1) Cover terminal width 5.2 terminal width 5.2 gray (2) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.08-0.2 mm2 white gray 0.25-0.5 mm2 2 black 0.75-1 mm (3) Plug-in bridge, for cross bridging in the terminal center 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. Type Order No. Pcs. Pkt. STTB 2,5/ 2P-PV STTB 2,5/ 2P-PV BU 30 40 07 0 30 40 68 5 50 50 D-STTB 2,5/ 2P 30 40 09 6 50 ISH 2,5/0,2 ISH 2,5/0,5 ISH 2,5/1 30 02 84 3 30 02 85 6 30 02 86 9 50 50 50 30 30 16 1 30 30 17 4 30 30 18 7 30 30 19 0 30 30 21 3 30 30 22 6 50 50 50 50 10 10 FBS 2-5 FBS 3-5 FBS 4-5 FBS 5-5 FBS 10-5 FBS 20-5 Imax.: 24 A 24 A 24 A 24 A 24 A 24 A (4) Partition plate, for visual and electrical separation of terminal groups, 2 mm thick ATP-STTB 4 30 30 74 7 50 (5) Test adapter, for 4 mm ∅ PS test plug and 4 mm ∅ safety test plugs, makes contact in the bridge shaft PAI 4 30 30 92 5 10 MPS-RD 02 01 55 3 10 PS 5 30 30 98 3 10 PC 30 40 58 8 50 WST 2,5 30 30 94 1 50 SZF 1 - 0,6 x 3,5 12 04 51 7 10 ZBF 5:UNPRINTED 08 08 64 2 10 (6) 2.3 mm ∅ test plug 1), consisting of metal part and red insulating sleeve (7) Modular test plug, labeling with ZBF 5 (8) Coding star, with 4 coding pins, for mounting in all base terminal blocks (9) Warning cover, for the actuating ducts of the "mini-spring" ST spring cage terminal blocks (10) Screwdriver, for actuating the tension spring (11) Zack strip, flat, for labeling the outer marker grooves white Dimensions Width / length / end cover width [mm] Height (NS 35/7,5 / NS 35/15) [mm] Technical data in accordance with IEC / DIN VDE Maximum // Rated data [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG 1 ) Further colors on request. Phoenix Contact page 6 of 27 5.2 / 71.5 / 2.2 47.5 / 55 24 / 4 // 20 / 2.5 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 10 A3 PA V0 600 / 20 / 26-12 600 / 20 / 26-12 Pluggable Spring Cage Terminal Blocks ST 2,5/ 2P (IEC) [mm2] Connection data rigid solid flexible stranded AWG I [A] U [V] 0.08-4 0.08-2.5 28-12 24 500 Technical data Type Order No. Pcs. Pkt. ST 2,5/ 2P ST 2,5/ 2P BU 30 42 13 3 30 42 09 4 50 50 gray D-ST 2,5 30 30 41 7 50 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. FBS 2-5 FBS 3-5 FBS 4-5 FBS 5-5 FBS 10-5 FBS 20-5 30 30 16 1 30 30 17 4 30 30 18 7 30 30 19 0 30 30 21 3 30 30 22 6 50 50 50 50 10 10 Spring cage terminal block, for mounting on 3 gray blue (1) Cover (2) Plug-in bridge, for cross bridging in the terminal center terminal width 5.2 terminal width 5.2 Imax.: 24 A 24 A 24 A 24 A 24 A 24 A (3) Partition plate, for visual and electrical separation of terminal groups, 2 mm thick ATP-ST 4 30 30 72 1 50 (4) Test adapter, for 4 mm ∅ PS test plug and 4 mm ∅ safety test plugs, makes contact in the bridge shaft PAI 4 30 30 92 5 10 MPS-RD 02 01 55 3 10 PS 5 30 30 98 3 10 PC 30 40 58 8 50 ZB 5:UNPRINTED 10 50 00 4 10 (5) 2.3 mm ∅ test plug 1), consisting of metal part and red insulating sleeve (6) Modular test plug, labeling with ZBF 5 (7) Coding star, with 4 coding pins, for mounting in all base terminal blocks (8) Zack strip, for labeling the outer marker grooves, white Dimensions Width / length / end cover width [mm] Height (NS 35/7,5 / NS 35/15) [mm] Technical data in accordance with IEC / DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG 1 ) Further colors on request. Phoenix Contact page 7 of 27 5.2 / 48.5 / 2.2 36.5 / 44 24 / 4 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 – – PA V0 applied for applied for Pluggable Spring Cage Terminal Blocks ST 2,5-QUATTRO/ 4P (IEC) [mm2] rigid solid flexible stranded AWG I [A] U [V] Connection data 0.08-4 0.08-2.5 28-12 24* 500 * The max. load current must not be exceeded by the total current of all connected conductors. Technical data Spring cage terminal block, for mounting on 3 gray blue (1) Cover terminal width 5.2 terminal width 5.2 gray (2) Cover segment, serves for gray covering multi-conductor terminal blocks when two-conductor terminal blocks are aligned (3) Plug-in bridge, for cross bridging in the terminal center 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. Type Order No. Pcs. Pkt. ST 2,5-QUATTRO/ 4P ST 2,5-QUATTRO/ 4P BU 30 42 15 9 30 42 08 1 50 50 D-ST 2,5-QUATTRO/4P 30 42 17 5 50 DS-ST 2,5/2P 30 42 33 7 50 30 30 16 1 30 30 17 4 30 30 18 7 30 30 19 0 30 30 21 3 30 30 22 6 50 50 50 50 10 10 FBS 2-5 FBS 3-5 FBS 4-5 FBS 5-5 FBS 10-5 FBS 20-5 Imax.: 24 A 24 A 24 A 24 A 24 A 24 A (4) Partition plate, for visual and electrical separation of terminal groups, 2 mm thick ATP-ST QUATTRO 30 30 81 5 50 (5) Test adapter, for 4 mm ∅ PS test plug and 4 mm ∅ safety test plugs, makes contact in the bridge shaft PAI 4 30 30 92 5 10 MPS-RD 02 01 55 3 10 PS 5 30 30 98 3 10 PC 30 40 58 8 50 ZB 5:UNPRINTED 10 50 00 4 10 (6) 2.3 mm ∅ test plug 1), consisting of metal part and red insulating sleeve (7) Modular test plug, labeling with ZBF 5 (8) Coding star, with 4 coding pins, for mounting in all base terminal blocks (9) Zack strip, for labeling the outer marker grooves, white Dimensions Width / length / end cover width [mm] Height (NS 35/7,5 / NS 35/15) [mm] Technical data in accordance with IEC / DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG 1 ) Further colors on request. Phoenix Contact page 8 of 27 5.2 / 89.5 / 2.2 36.5 / 44 24 / 4 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 – – PA V0 applied for applied for Pluggable Spring Cage Ground Terminal Blocks ST 2,5/ 1P-PE IEC [mm2] rigid solid flexible stranded AWG Connection data 0.08-4 0.08-2.5 28-12 Observe the current carrying capacity of the mounting rails. u Technical data Spring cage terminal block, for mounting on 3 green-yellow (1) Cover terminal width 5.2 gray (2) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.08-0.2 mm2 white gray 0.25-0.5 mm2 2 black 0.75-1 mm (3) Partition plate, for visual and electrical separation of terminal groups, 2 mm thick (4) Coding star, with 4 coding pins, for mounting in all base terminal blocks (5) Warning cover, for the actuating ducts of the "mini-spring" ST spring cage terminal blocks (6) Screwdriver, for actuating the tension spring Type Order No. Pcs. Pkt. ST 2,5/ 1P-PE 30 40 02 5 50 D-ST 2,5 30 30 41 7 50 ISH 2,5/0,2 ISH 2,5/0,5 ISH 2,5/1 30 02 84 3 30 02 85 6 30 02 86 9 50 50 50 ATP-ST 4 30 30 72 1 50 PC 30 40 58 8 50 WST 2,5 30 30 94 1 50 SZF 1 - 0,6 x 3,5 12 04 51 7 10 (7) Zack strip, flat, for labeling the outer marker grooves white ZBF 5:UNPRINTED 08 08 64 2 10 (8) Zack strip, 10-section, for labeling in the terminal center white ZB 5:UNPRINTED 10 50 00 4 10 Dimensions Width / length / end cover width [mm] Height (NS 35/7,5 / NS 35/15) [mm] Technical data in accordance with IEC / DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG Phoenix Contact page 9 of 27 5.2 / 48.5 / 2.2 36.5 / 44 – 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 10 A3 PA V0 – / – / 26-12 – / – / 26-12 Pluggable Spring Cage Ground Terminal Blocks ST 2,5-TWIN/ 1P-PE IEC [mm2] rigid solid flexible stranded AWG Connection data 0.08-4 0.08-2.5 28-12 Observe the current carrying capacity of the mounting rails. Technical data Spring cage terminal block, for mounting on 3 green-yellow (1) Cover terminal width 5.2 gray (2) Cover segment, serves for gray covering multi-conductor terminal blocks when two-conductor terminal blocks are aligned (3) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.08-0.2 mm2 white gray 0.25-0.5 mm2 black 0.75-1 mm2 (4) Plug-in bridge, for cross bridging in the terminal center 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. Type Order No. Pcs. Pkt. ST 2,5-TWIN/ 1P-PE 30 42 12 0 50 D-ST 2,5-TWIN 30 30 48 8 50 DS-ST 2,5 30 36 60 2 50 ISH 2,5/0,2 ISH 2,5/0,5 ISH 2,5/1 30 02 84 3 30 02 85 6 30 02 86 9 50 50 50 30 30 16 1 30 30 17 4 30 30 18 7 30 30 19 0 30 30 21 3 30 30 22 6 50 50 50 50 10 10 ATP-ST-TWIN 30 30 78 9 50 PC 30 40 58 8 50 WST 2,5 30 30 94 1 50 SZF 1 - 0,6 x 3,5 12 04 51 7 10 FBS 2-5 FBS 3-5 FBS 4-5 FBS 5-5 FBS 10-5 FBS 20-5 (5) Partition plate, for visual and electrical separation of terminal groups, 2 mm thick (6) Coding star, with 4 coding pins, for mounting in all base terminal blocks (7) Warning cover, for the actuating ducts of the "mini-spring" ST spring cage terminal blocks (8) Screwdriver, for actuating the tension spring Imax.: 24 A 24 A 24 A 24 A 24 A 24 A (9) Zack strip, flat, for labeling the outer marker grooves white ZBF 5:UNPRINTED 08 08 64 2 10 (10) Zack strip, 10-section, for labeling in the terminal center white ZB 5:UNPRINTED 10 50 00 4 10 Dimensions Width / length / end cover width [mm] Height (NS 35/7,5 / NS 35/15) [mm] Technical data in accordance with IEC / DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG Phoenix Contact page 10 of 27 5.2 / 60.5 / 2.2 36.5 / 44 – 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 10 A3 PA V0 applied for applied for Pluggable Spring Cage Ground Terminal Blocks ST 2,5-QUATTRO/ 2P-PE IEC [mm2] rigid solid flexible stranded AWG Connection data 0.08-4 0.08-2.5 28-12 Observe the current carrying capacity of the mounting rails. u Technical data Spring cage terminal block, for mounting on 3 green-yellow (1) Cover terminal width 5.2 gray (2) Cover segment, serves for gray covering multi-conductor terminal blocks when two-conductor terminal blocks are aligned (3) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.08-0.2 mm2 white gray 0.25-0.5 mm2 black 0.75-1 mm2 (4) Partition plate, for visual and electrical separation of terminal groups, 2 mm thick (5) Coding star, with 4 coding pins, for mounting in all base terminal blocks (6) Warning cover, for the actuating ducts of the "mini-spring" ST spring cage terminal blocks (7) Screwdriver, for actuating the tension spring Type Order No. Pcs. Pkt. ST 2,5-QUATTRO/ 2P-PE 30 40 04 1 50 D-ST 2,5-QUATTRO/ 2P 30 40 08 3 50 DS-ST 2,5/P 30 41 01 1 50 ISH 2,5/0,2 ISH 2,5/0,5 ISH 2,5/1 30 02 84 3 30 02 85 6 30 02 86 9 50 50 50 ATP-ST QUATTRO 30 30 81 5 50 PC 30 40 58 8 50 WST 2,5 30 30 94 1 50 SZF 1 - 0,6 x 3,5 12 04 51 7 10 (8) Zack strip, flat, for labeling the outer marker grooves white ZBF 5:UNPRINTED 08 08 64 2 10 (9) Zack strip, 10-section, for labeling in the terminal center white ZB 5:UNPRINTED 10 50 00 4 10 Dimensions Width / length / end cover width [mm] Height (NS 35/7,5 / NS 35/15) [mm] Technical data in accordance with IEC / DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG Phoenix Contact page 11 of 27 5.2 / 81 / 2.2 36.5 / 44 – 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 10 A3 PA V0 – / – / 26-12 – / – / 26-12 Pluggable Spring Cage Ground Terminal Blocks STTB 2,5/ 2P-PE (IEC) [mm2] rigid solid flexible stranded AWG Connection data 0.08-4 0.08-2.5 28-12 Observe the current carrying capacity of the mounting rails. u Technical data Spring cage terminal block, for mounting on 3 green-yellow (1) Cover terminal width 5.2 gray (2) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.08-0.2 mm2 white gray 0.25-0.5 mm2 2 black 0.75-1 mm (3) Partition plate, for visual and electrical separation of terminal groups, 2 mm thick (4) Coding star, with 4 coding pins, for mounting in all base terminal blocks (5) Warning cover, for the actuating ducts of the "mini-spring" ST spring cage terminal blocks (6) Screwdriver, for actuating the tension spring (7) Zack strip, flat, for labeling the outer marker grooves white Type Order No. Pcs. Pkt. STTB 2,5/ 2P-PE 30 40 06 7 50 D-STTB 2,5/ 2P 30 40 09 6 50 ISH 2,5/0,2 ISH 2,5/0,5 ISH 2,5/1 30 02 84 3 30 02 85 6 30 02 86 9 50 50 50 ATP-STTB 4 30 30 74 7 50 PC 30 40 58 8 50 WST 2,5 30 30 94 1 50 SZF 1 - 0,6 x 3,5 12 04 51 7 10 ZBF 5:UNPRINTED 08 08 64 2 10 Dimensions Width / length / end cover width [mm] Height (NS 35/7,5 / NS 35/15) [mm] Technical data in accordance with IEC / DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG Phoenix Contact page 12 of 27 5.2 / 71.5 / 2.2 47.5 / 55 – 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 10 A3 PA V0 – / – / 26-12 – / – / 26-12 Pluggable Spring Cage Ground Terminal Blocks ST 2,5/ 2P-PE (IEC) [mm2] rigid solid flexible stranded AWG Connection data 0.08-4 0.08-2.5 28-12 Observe the current carrying capacity of the mounting rails. Technical data Type Order No. Pcs. Pkt. ST 2,5/ 2P-PE 30 42 14 6 50 gray D-ST 2,5 30 30 41 7 50 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. FBS 2-5 FBS 3-5 FBS 4-5 FBS 5-5 FBS 10-5 FBS 20-5 30 30 16 1 30 30 17 4 30 30 18 7 30 30 19 0 30 30 21 3 30 30 22 6 50 50 50 50 10 10 (3) Partition plate, for visual and electrical separation of terminal groups, 2 mm thick ATP-ST 4 30 30 72 1 50 (4) Test adapter, for 4 mm ∅ PS test plug and 4 mm ∅ safety test plugs, makes contact in the bridge shaft PAI 4 30 30 92 5 10 MPS-RD 02 01 55 3 10 PS 5 30 30 98 3 10 PC 30 40 58 8 50 ZB 5:UNPRINTED 10 50 00 4 10 Spring cage terminal block, for mounting on 3 green-yellow (1) Cover (2) Plug-in bridge, for cross bridging in the terminal center terminal width 5.2 (5) 2.3 mm ∅ test plug 1), consisting of metal part and red insulating sleeve (6) Modular test plug, labeling with ZBF 5 (7) Coding star, with 4 coding pins, for mounting in all base terminal blocks (8) Zack strip, for labeling the outer marker grooves, white Dimensions Width / length / end cover width [mm] Height (NS 35/7,5 / NS 35/15) [mm] Technical data in accordance with IEC / DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG 1 ) Further colors on request. Phoenix Contact page 13 of 27 5.2 / 48.5 / 2.2 36.5 / 44 – 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 – – PA V0 applied for applied for Pluggable Spring Cage Ground Terminal Blocks ST 2,5-QUATTRO/ 4P-PE IEC [mm2] rigid solid flexible stranded AWG Connection data 0.08-4 0.08-2.5 28-12 Observe the current carrying capacity of the mounting rails. Technical data Type Order No. Pcs. Pkt. ST 2,5-QUATTRO/ 4P-PE 30 42 16 2 50 D-ST 2,5-QUATTRO/4P 30 42 17 5 50 DS-ST 2,5/2P 30 42 33 7 50 FBS 2-5 FBS 3-5 FBS 4-5 FBS 5-5 FBS 10-5 FBS 20-5 30 30 16 1 30 30 17 4 30 30 18 7 30 30 19 0 30 30 21 3 30 30 22 6 50 50 50 50 10 10 (4) Partition plate, for visual and electrical separation of terminal groups, 2 mm thick ATP-ST QUATTRO 30 30 81 5 50 (5) Test adapter, for 4 mm ∅ PS test plug and 4 mm ∅ safety test plugs, makes contact in the bridge shaft PAI 4 30 30 92 5 10 MPS-RD 02 01 55 3 10 PS 5 30 30 98 3 10 PC 30 40 58 8 50 ZB 5:UNPRINTED 10 50 00 4 10 Spring cage terminal block, for mounting on 3 green-yellow (1) Cover terminal width 5.2 gray (2) Cover segment, serves for gray covering multi-conductor terminal blocks when two-conductor terminal blocks are aligned (3) Plug-in bridge, for cross bridging in the terminal center 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. (6) 2.3 mm ∅ test plug 1), consisting of metal part and red insulating sleeve (7) Modular test plug, labeling with ZBF 5 (8) Coding star, with 4 coding pins, for mounting in all base terminal blocks (9) Zack strip, for labeling the outer marker grooves white Dimensions Width / length / end cover width [mm] Height (NS 35/7,5 / NS 35/15) [mm] Technical data in accordance with IEC / DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG 1 ) Further colors on request. Phoenix Contact page 14 of 27 5.2 / 89.5 / 2.2 36.5 / 44 – 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 – – PA V0 applied for applied for ST-COMBI Receptacles SC 2,5/... (IEC) [mm2] Connection data rigid solid flexible stranded AWG I [A] U [V] 0.08-4 0.08-2.5 28-12 24 500 Technical data ST-COMBI receptacle, single, not bridgeable, 5.2 mm wide gray gray gray gray gray gray gray gray gray gray gray gray gray gray 2-pos. 3-pos. 4-pos. 5-pos. 6-pos. 7-pos. 8-pos. 9-pos. 10-pos. 11-pos. 12-pos. 13-pos. 14-pos. 15-pos. (1) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.08-0.2 mm2 white gray 0.25-0.5 mm2 2 black 0.75-1 mm (2) Strain relief, (3) Zack strip, flat, for labeling the outer marker grooves black black 2-pos. 4-pos. white Type Order No. Pcs. Pkt. SC 2,5/2 SC 2,5/3 SC 2,5/4 SC 2,5/5 SC 2,5/6 SC 2,5/7 SC 2,5/8 SC 2,5/9 SC 2,5/10 SC 2,5/11 SC 2,5/12 SC 2,5/13 SC 2,5/14 SC 2,5/15 30 41 31 2 30 42 26 9 30 42 27 2 30 42 28 5 30 42 29 8 30 41 36 7 30 42 30 8 30 41 38 3 30 42 31 1 30 41 40 6 30 42 32 4 30 41 42 2 30 41 43 5 30 41 44 8 50 50 50 50 25 25 25 25 25 10 10 10 10 10 ISH 2,5/0,2 ISH 2,5/0,5 ISH 2,5/1 30 02 84 3 30 02 85 6 30 02 86 9 50 50 50 PDZ/2 PDZ/4 30 40 56 2 30 40 57 5 50 50 ZBF 5:UNPRINTED 08 08 64 2 10 Technical data in accordance with IEC / DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG Phoenix Contact page 15 of 27 24 / 4 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 10 A3 PA V0 applied for applied for ST-COMBI Receptacles SC 2,5-RZ/... (IEC) [mm2] Connection data rigid solid flexible stranded AWG I [A] U [V] 0.08-4 0.08-2.5 28-12 24 500 Technical data ST-COMBI receptacle, single, not bridgeable, 5.2 mm wide with engagement pin gray gray gray gray gray gray gray gray gray gray gray gray gray gray 2-pos. 3-pos. 4-pos. 5-pos. 6-pos. 7-pos. 8-pos. 9-pos. 10-pos. 11-pos. 12-pos. 13-pos. 14-pos. 15-pos. (1) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.08-0.2 mm2 white gray 0.25-0.5 mm2 2 black 0.75-1 mm (2) Strain relief, (3) Zack strip, flat, for labeling the outer marker grooves black black 2-pos. 4-pos. white Type Order No. Pcs. Pkt. SC 2,5-RZ/2 SC 2,5-RZ/3 SC 2,5-RZ/4 SC 2,5-RZ/5 SC 2,5-RZ/6 SC 2,5-RZ/7 SC 2,5-RZ/8 SC 2,5-RZ/9 SC 2,5-RZ/10 SC 2,5-RZ/11 SC 2,5-RZ/12 SC 2,5-RZ/13 SC 2,5-RZ/14 SC 2,5-RZ/15 30 41 51 6 30 41 52 9 30 41 53 6 30 41 54 5 30 41 55 8 30 41 56 1 30 41 57 4 30 41 59 0 30 41 58 7 30 41 60 0 30 41 61 3 30 41 62 6 30 41 63 9 30 41 64 2 50 50 50 50 25 25 25 25 25 10 10 10 10 10 ISH 2,5/0,2 ISH 2,5/0,5 ISH 2,5/1 30 02 84 3 30 02 85 6 30 02 86 9 50 50 50 PDZ/2 PDZ/4 30 40 56 2 30 40 57 5 50 50 ZBF 5:UNPRINTED 08 08 64 2 10 Technical data in accordance with IEC / DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG 24 / 4 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 10 A3 PA V0 3,5 applied for applied for 5,2 n x 5,2 Drilling plan: SC 2,5-RZ... Example: 1 x SC 2,5-RZ/6 Plate thickness: 0.8-1.5 mm Phoenix Contact page 16 of 27 ST-COMBI Receptacles for Self-Assembly With the ST-COMBI receptacles for self-assembly, we offer a solution for every task and it can be implemented by the user himself. The receptacle is assembled directly on site by snapping together oneposition receptacle elements. For receptacle types SC 2,5/1-L and SC 2,5-RZ/1-L, one-position base versions are available in gray, blue and green-yellow. Example for the structure of a 6-position receptacle: : SC 2,5/1-L Structure of a receptacle For multi-position receptacles, the corresponding number of one-position receptacle elements and a cover are required. The individual receptacle elements and the cover are connected by pushing them together and are held by the engagement pins. When mounting receptacles with engagement pins, an element with an engagement pin should be mounted at the beginning and end of the receptacle. For longer receptacles, we recommend that an element with engagement pin is used after at least every 6th position. To ensure a secure fit, the bore holes must be burr-free. Phoenix Contact page 17 of 27 SC 2,5/1-L BU SC 2,5/1-L GNYE D-SC 2,5 ST-COMBI Receptacles SC 2,5/1-L (IEC) [mm2] Connection data rigid solid flexible stranded AWG I [A] U [V] 0.08-4 0.08-2.5 28-12 24 500 Technical data Type Order No. Pcs. Pkt. SC 2,5/1-L SC 2,5/1-L BU SC 2,5/1-L GNYE 30 42 18 8 30 42 19 1 30 42 20 1 50 50 50 D-SC 2,5 30 42 24 3 50 (2) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.08-0.2 mm2 white gray 0.25-0.5 mm2 2 black 0.75-1 mm ISH 2,5/0,2 ISH 2,5/0,5 ISH 2,5/1 30 02 84 3 30 02 85 6 30 02 86 9 50 50 50 (3) 2.3 mm Ø test plugs 1), consisting of metal part and red insulating sleeve MPS-RD 02 01 55 3 10 WST 2,5 30 30 94 1 50 PDZ/2 PDZ/4 30 40 56 2 30 40 57 5 50 50 SZF 1 - 0,6 x 3,5 12 04 51 7 10 ZBF 5:UNPRINTED 08 08 64 2 10 ST-COMBI receptacle, single, not bridgeable, 5.2 mm wide gray blue green-yellow (1) Cover, 1-pos. 1-pos. 1-pos. gray (4) Warning cover, for the actuating ducts of the "mini-spring" ST spring cage terminal blocks (5) Strain relief, black black 2-pos. 4-pos. (6) Screwdriver, for actuating the tension spring (7) Zack strip, flat, for labeling the outer marker grooves white Technical data in accordance with IEC / DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG 1 ) Further colors on request. Phoenix Contact page 18 of 27 24 / 4 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 10 A3 PA V0 applied for applied for ST-COMBI Receptacles SC 2,5-RZ/1-L (IEC) [mm2] Connection data rigid solid flexible stranded AWG I [A] U [V] 0.08-4 0.08-2.5 28-12 24 500 Technical data Type Order No. Pcs. Pkt. SC 2,5-RZ/1-L SC 2,5-RZ/1-L BU SC 2,5-RZ/1-L GNYE 30 42 21 4 30 42 22 7 30 42 23 0 50 50 50 D-SC 2,5 30 42 24 3 50 (2) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.08-0.2 mm2 white gray 0.25-0.5 mm2 2 black 0.75-1 mm ISH 2,5/0,2 ISH 2,5/0,5 ISH 2,5/1 30 02 84 3 30 02 85 6 30 02 86 9 50 50 50 (3) 2.3 mm Ø test plugs 1), consisting of metal part and red insulating sleeve MPS-RD 02 01 55 3 10 WST 2,5 30 30 94 1 50 PDZ/2 PDZ/4 30 40 56 2 30 40 57 5 50 50 SZF 1 - 0,6 x 3,5 12 04 51 7 10 ZBF 5:UNPRINTED 08 08 64 2 10 ST-COMBI receptacle, single, not bridgeable, 5.2 mm wide with engagement pin gray blue green-yellow (1) Cover, 1-pos. 1-pos. 1-pos. gray (4) Warning cover, for the actuating ducts of the "mini-spring" ST spring cage terminal blocks (5) Strain relief, black black 2-pos. 4-pos. (6) Screwdriver, for actuating the tension spring (7) Zack strip, flat, for labeling the outer marker grooves white Technical data in accordance with IEC / DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG 0.25 - 2.5 0.25 - 2.5 0.5 10 A3 PA V0 applied for applied for ) Further colors on request. 3,5 1 24 / 4 6/3 III / I 5,2 n x 5,2 Drilling plan: SC 2,5-RZ... Example: 6 x SC 2,5-RZ/1-L Plate thickness: 0.8-1.5 mm Phoenix Contact page 19 of 27 ST-COMBI Plugs SP 2,5 (IEC) [mm2] Connection data rigid solid flexible stranded AWG I [A] U [V] 0.08-4 0.08-2.5 28-12 24 500 u Technical data ST-COMBI plug, single, not bridgeable, 5.2 mm wide gray gray gray gray gray gray gray gray gray gray gray gray gray gray gray blue green-yellow 1-pos. 2-pos. 3-pos. 4-pos. 5-pos. 6-pos. 7-pos. 8-pos. 9-pos. 10-pos. 11-pos. 12-pos. 13-pos. 14-pos. 15-pos. 1-pos. 1-pos. (1) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.08-0.2 mm2 white gray 0.25-0.5 mm2 black 0.75-1 mm2 (2) Strain relief, (3) Snap-lock fitting, for all plugs (4) Snap-lock fitting and strain relief, for all connectors Order No. Pcs. Pkt. SP 2,5/1 SP 2,5/2 SP 2,5/3 SP 2,5/4 SP 2,5/5 SP 2,5/6 SP 2,5/7 SP 2,5/8 SP 2,5/9 SP 2,5/10 SP 2,5/11 SP 2,5/12 SP 2,5/13 SP 2,5/14 SP 2,5/15 SP 2,5/1 BU SP 2,5/1 GNYE 30 40 25 8 30 40 26 1 30 40 27 4 30 40 28 7 30 40 29 0 30 40 30 0 30 40 31 3 30 40 32 6 30 40 33 9 30 40 34 2 30 40 35 5 30 40 36 8 30 40 37 1 30 40 38 4 30 40 39 7 30 40 69 8 30 40 70 8 50 50 50 50 50 25 25 25 25 25 10 10 10 10 10 50 50 ISH 2,5/0,2 ISH 2,5/0,5 ISH 2,5/1 30 02 84 3 30 02 85 6 30 02 86 9 50 50 50 black black 2-pos. 4-pos. PZ/2 PZ/4 30 40 62 7 30 40 64 3 50 50 orange orange 1-pos. 2-pos. PR PR/2 30 40 55 9 30 40 63 0 50 50 orange 2-pos. PRZ 30 40 61 4 50 PSH 3-6 PSH 5-10 30 40 59 1 30 40 60 1 50 50 ZBF 5:UNPRINTED 08 08 64 2 10 (5) Shielding, for mounting on PZ/... and PRZ, for shielded conductors with (6) Zack strip, flat, for labeling the outer marker grooves Type 3-6 mm ∅ 5-10 mm ∅ white Technical data in accordance with IEC / DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG Phoenix Contact page 20 of 27 24 / 4 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 10 A3 PA V0 600 / 20 / 26-12 600 / 20 / 26-12 ST-COMBI Plugs SPB 2,5 (IEC) [mm2] Connection data rigid solid flexible stranded AWG I [A] U [V] 0.08-4 0.08-2.5 28-12 24 500 u Technical data ST-COMBI plug, single, bridgeable, 5.2 mm wide gray gray gray gray gray gray gray gray gray gray gray gray gray gray gray blue green-yellow (1) Plug-in bridge, for cross bridging in the bridge shaft 1-pos. 2-pos. 3-pos. 4-pos. 5-pos. 6-pos. 7-pos. 8-pos. 9-pos. 10-pos. 11-pos. 12-pos. 13-pos. 14-pos. 15-pos. 1-pos. 1-pos. 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. (4) Snap-lock fitting, for all plugs (5) Snap-lock fitting and strain relief, for all plugs Pcs. Pkt. SPB 2,5/1 SPB 2,5/2 SPB 2,5/3 SPB 2,5/4 SPB 2,5/5 SPB 2,5/6 SPB 2,5/7 SPB 2,5/8 SPB 2,5/9 SPB 2,5/10 SPB 2,5/11 SPB 2,5/12 SPB 2,5/13 SPB 2,5/14 SPB 2,5/15 SPB 2,5/1 BU SPB 2,5/1 GNYE 30 40 10 6 30 40 11 9 30 40 12 2 30 40 13 5 30 40 14 3 30 40 15 1 30 40 16 4 30 40 17 7 30 40 18 0 30 40 19 3 30 40 20 3 30 40 21 6 30 40 22 9 30 40 23 2 30 40 24 5 30 40 72 4 30 40 71 1 50 50 50 50 50 25 25 25 25 25 10 10 10 10 10 50 50 30 30 16 1 30 30 17 4 30 30 18 7 30 30 19 0 30 30 21 3 30 30 22 6 50 50 50 50 10 10 ISH 2,5/0,2 ISH 2,5/0,5 ISH 2,5/1 30 02 84 3 30 02 85 6 30 02 86 9 50 50 50 Imax.: 24 A 24 A 24 A 24 A 24 A 24 A black black 2-pos. 4-pos. PZ/2 PZ/4 30 40 62 7 30 40 64 3 50 50 orange orange 1-pos. 2-pos. PR PR/2 30 40 55 9 30 40 63 0 50 50 orange 2-pos. PRZ 30 40 61 4 50 PSH 3-6 PSH 5-10 30 40 59 1 30 40 60 1 50 50 ZBF 5:UNPRINTED 08 08 64 2 10 (6) Shielding, for mounting on PZ/... and PRZ, for shielded conductors with (7) Zack strip, flat, for labeling the outer marker grooves Order No. FBS 2-5 FBS 3-5 FBS 4-5 FBS 5-5 FBS 10-5 FBS 20-5 (2) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.08-0.2 mm2 white gray 0.25-0.5 mm2 black 0.75-1 mm2 (3) Strain relief, Type 3-6 mm ∅ 5-10 mm ∅ white Technical data in accordance with IEC / DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG Phoenix Contact page 21 of 27 24 / 4 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 10 A3 PA V0 600 / 20 / 26-12 600 / 20 / 26-12 ST-COMBI Plugs SPDB 2,5 (IEC) [mm2] Connection data rigid solid flexible stranded AWG I [A] U [V] 0.08-4 0.08-2.5 28-12 24 500 u Technical data ST-COMBI plug, double, bridgeable, 5.2 mm wide gray gray gray gray gray gray gray gray gray gray gray gray gray gray gray blue green-yellow (1) Plug-in bridge, for cross bridging in the bridge shaft 1-pos. 2-pos. 3-pos. 4-pos. 5-pos. 6-pos. 7-pos. 8-pos. 9-pos. 10-pos. 11-pos. 12-pos. 13-pos. 14-pos. 15-pos. 1-pos. 1-pos. 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. (4) Snap-lock fitting, for all plugs (5) Snap-lock fitting and strain relief, for all plugs Pcs. Pkt. SPDB 2,5/1 SPDB 2,5/2 SPDB 2,5/3 SPDB 2,5/4 SPDB 2,5/5 SPDB 2,5/6 SPDB 2,5/7 SPDB 2,5/8 SPDB 2,5/9 SPDB 2,5/10 SPDB 2,5/11 SPDB 2,5/12 SPDB 2,5/13 SPDB 2,5/14 SPDB 2,5/15 SPDB 2,5/1 BU SPDB 2,5/1 GNYE 30 40 40 7 30 40 41 0 30 40 42 3 30 40 43 6 30 40 44 9 30 40 45 2 30 40 46 5 30 40 47 8 30 40 48 1 30 40 49 4 30 40 50 4 30 40 51 7 30 40 52 0 30 40 53 3 30 40 54 6 30 40 73 7 30 40 74 0 50 50 50 50 50 25 25 25 25 25 10 10 10 10 10 50 50 30 30 16 1 30 30 17 4 30 30 18 7 30 30 19 0 30 30 21 3 30 30 22 6 50 50 50 50 10 10 ISH 2,5/0,2 ISH 2,5/0,5 ISH 2,5/1 30 02 84 3 30 02 85 6 30 02 86 9 50 50 50 Imax.: 24 A 24 A 24 A 24 A 24 A 24 A black black 2-pos. 4-pos. PDZ/2 PDZ/4 30 40 56 2 30 40 57 5 50 50 orange orange 1-pos. 2-pos. PR PR/2 30 40 55 9 30 40 63 0 50 50 orange 2-pos. PRZ 30 40 61 4 50 PSH 3-6 PSH 5-10 30 40 59 1 30 40 60 1 50 50 ZBF 5:UNPRINTED 08 08 64 2 10 (6) Shielding, for mounting on PZ/... and PRZ, for shielded conductors with (7) Zack strip, flat, for labeling the outer marker grooves Order No. FBS 2-5 FBS 3-5 FBS 4-5 FBS 5-5 FBS 10-5 FBS 20-5 (2) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.08-0.2 mm2 white gray 0.25-0.5 mm2 black 0.75-1 mm2 (3) Strain relief, Type 3-6 mm ∅ 5-10 mm ∅ white Technical data in accordance with IEC / DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG Phoenix Contact page 22 of 27 24 / 4 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 10 A3 PA V0 600 / 20 / 26-12 600 / 20 / 26-12 ST-COMBI Plugs for Self-Assembly Withden Mit theselbstkonfektionierbaren ST-COMBI plugs for self-assembly, ST-COMBI-Steckern we offer a ist für jede solution for Aufgabenstellung every task and it can einebeLösung implemented vorhanden, by the die vom user himself. Anwender The plug selbst is assembled realisiert werden directlykann. on site Der by Stecker wird snapping together hierbeione-position direkt vor Ort plug anwendungsgerecht elements. aus einpoligen Steckerelementen zusammengerastet. For plug types SP 2,5…, SPB 2,5… and SPDB 2,5…, Für one-position die vorhandenen base versions Steckertypen are available SP 2,5…, in gray, blue SPB and green-yellow: 2,5… und SPDB 2,5… stehen jeweils einpolige Grundvarianten in den Farben grau, blau, grün-gelb zur Verfügung: Structure of a plug For each multiple-position plug, a left element (at the beginning of the plug) and a right element (at the end of the plug) is required. How many middle elements need to be inserted depends on the number of positions of the desired plug. The individual elements are connected by pushing them together and are held by the engagement pins. Example for the structure of a 6-position plug: SPB 2,5-L left element SP…2,5-L left side: smooth right side: open SPB 2,5-M middle element SP…2,5-M left side: engagement pin right side: open right element SP…2,5-R left side: engagement pin right side: end cover In this view, the open side of the plug is on the right. The different color versions can be combined with each other in any order for the various plug types. Phoenix Contact page 23 of 27 SPB 2,5-M BU SPB 2,5-R GNYE Plugs for Self-Assembly SP 2,5/1… (IEC) [mm2] Connection data rigid solid flexible stranded AWG I [A] U [V] 0.28-4 0.08-2.5 28-12 24 500 u Technical data Type Order No. Pcs. Pkt. ST-COMBI plug, single, not bridgeable, 5.2 mm wide, left element gray blue green-yellow SP 2,5/1-L SP 2,5/1-L BU SP 2,5/1-L GNYE 30 43 01 9 30 43 02 2 30 43 03 5 50 50 50 ST-COMBI plug, single, not bridgeable, 5.2 mm wide, middle element gray blue green-yellow SP 2,5/1-M SP 2,5/1-M BU SP 2,5/1-M GNYE 30 43 04 3 30 43 05 1 30 43 06 4 50 50 50 ST-COMBI plug, single, not bridgeable, 5.2 mm wide, right element gray blue green-yellow SP 2,5/1-R SP 2,5/1-R BU SP 2,5/1-R GNYE 30 43 07 7 30 43 08 0 30 43 09 3 50 50 50 (1) Strain relief, (2) Snap-lock fitting, for all plugs (3) Snap-lock fitting and strain relief, for all plugs black black 2-pos. 4-pos. PZ/2 PZ/4 30 40 62 7 30 40 64 3 50 50 orange orange 1-pos. 2-pos. PR PR/2 30 40 55 9 30 40 63 0 50 50 orange 2-pos. PRZ 30 40 61 4 50 PSH 3-6 PSH 5-10 30 40 59 1 30 40 60 1 50 50 ZBF 5:UNPRINTED 08 08 64 2 10 (4) Shielding, for mounting on PZ/... and PRZ, for shielded conductors with (5) Zack marker sheet, flat, for labeling the outer marker grooves 3-6 mm ∅ 5-10 mm ∅ white Technical data in accordance with IEC / DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG Phoenix Contact page 24 of 27 24 / 4 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 10 A3 PA V0 600 / 20 / 26-12 600 / 20 / 26-12 Plugs for Self-Assembly SPB 2,5/1… (IEC) [mm2] Connection data rigid solid flexible stranded AWG I [A] U [V] 0.08-4 0.08-2.5 28-12 24 500 u Technical data Type Order No. Pcs. Pkt. ST-COMBI plug, single, bridgeable, 5.2 mm wide, left element gray blue green-yellow SPB 2,5/1-L SPB 2,5/1-L BU SPB 2,5/1-L GNYE 30 43 10 3 30 43 11 6 30 43 12 9 50 50 50 ST-COMBI plug, single, bridgeable, 5.2 mm wide, middle element gray blue green-yellow SPB 2,5/1-M SPB 2,5/1-M BU SPB 2,5/1-M GNYE 30 43 13 2 30 43 14 5 30 43 15 8 50 50 50 ST-COMBI plug, single, bridgeable, 5.2 mm wide, right element gray blue green-yellow SPB 2,5/1-R SPB 2,5/1-R BU SPB 2,5/1-R GNYE 30 43 16 1 30 43 17 4 30 43 18 7 50 50 50 30 30 16 1 30 30 17 4 30 30 18 7 30 30 19 0 30 30 21 3 30 30 22 6 50 50 50 50 10 10 (1) Plug-in bridge, for cross bridging in the bridge shaft (2) Strain relief, (3) Snap-lock fitting, for all plugs (4) Snap-lock fitting and strain relief, for all plugs 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. Imax.: 24 A 24 A 24 A 24 A 24 A 24 A black black 2-pos. 4-pos. PZ/2 PZ/4 30 40 62 7 30 40 64 3 50 50 orange orange 1-pos. 2-pos. PR PR/2 30 40 55 9 30 40 63 0 50 50 orange 2-pos. PRZ 30 40 61 4 50 PSH 3-6 PSH 5-10 30 40 59 1 30 40 60 1 50 50 ZBF 5:UNPRINTED 08 08 64 2 10 (5) Shielding, for mounting on PZ/... and PRZ, for shielded conductors with (6) Zack strip, flat, for labeling the outer marker grooves FBS 2-5 FBS 3-5 FBS 4-5 FBS 5-5 FBS 10-5 FBS 20-5 3-6 mm ∅ 5-10 mm ∅ white Technical data in accordance with IEC / DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG Phoenix Contact page 25 of 27 24 / 4 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 10 A3 PA V0 600 / 20 / 26-12 600 / 20 / 26-12 Plugs for Self-Assembly SPDB 2,5/1… (IEC) [mm2] Connection data rigid solid flexible stranded AWG I [A] U [V] 0.08-4 0.08-2.5 28-12 24 500 u Technical data Type Order No. Pcs. Pkt. Plug, double, bridgeable, 5.2 mm wide, left element gray blue green-yellow SPDB 2,5/1-L SPDB 2,5/1-L BU SPDB 2,5/1-L GNYE 30 43 19 0 30 43 20 0 30 43 21 3 50 50 50 Plug, double, bridgeable, 5.2 mm wide, middle element gray blue green-yellow SPDB 2,5/1-M SPDB 2,5/1-M BU SPDB 2,5/1-M GNYE 30 43 22 6 30 43 23 9 30 43 24 2 50 50 50 Plug, double, bridgeable, 5.2 mm wide, right element gray blue green-yellow SPDB 2,5/1-R SPDB 2,5/1-R BU SPDB 2,5/1-R GNYE 30 43 25 5 30 43 26 8 30 43 27 1 50 50 50 30 30 16 1 30 30 17 4 30 30 18 7 30 30 19 0 30 30 21 3 30 30 22 6 50 50 50 50 10 10 (1) Plug-in bridge, for cross bridging in the bridge shaft (2) Strain relief, (3) Snap-lock fitting, for all plugs (4) Snap-lock fitting and strain relief, for all plugs 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. Imax.: 24 A 24 A 24 A 24 A 24 A 24 A black black 2-pos. 4-pos. PDZ/2 PDZ/4 30 40 56 2 30 40 57 5 50 50 orange orange 1-pos. 2-pos. PR PR/2 30 40 55 9 30 40 63 0 50 50 orange 2-pos. PRZ 30 40 61 4 50 PSH 3-6 PSH 5-10 30 40 59 1 30 40 60 1 50 50 ZBF 5:UNPRINTED 08 08 64 2 10 (5) Shielding, for mounting on PZ/... and PRZ, for shielded conductors with (6) Zack strip, flat, for labeling the outer marker grooves FBS 2-5 FBS 3-5 FBS 4-5 FBS 5-5 FBS 10-5 FBS 20-5 3-6 mm ∅ 5-10 mm ∅ white Technical data in accordance with IEC / DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulation material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulation material Inflammability class acc. to UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG Phoenix Contact page 26 of 27 24 / 4 6/3 III / I 0.25 - 2.5 0.25 - 2.5 0.5 10 A3 PA V0 600 / 20 / 26-12 600 / 20 / 26-12 ST-COMBI Accessories Technical data Strain relief, for SP ... and SPB ... plugs Strain relief, for SPDB ... plugs and receptacle SC... Snap-lock fitting, for all plugs Snap-lock fitting and strain relief for all plugs Type Order No. Pcs. Pkt. black black 2-pos. 4-pos. PZ/2 PZ/4 30 40 62 7 30 40 64 3 50 50 black black 2-pos. 4-pos. PDZ/2 PDZ/4 30 40 56 2 30 40 57 5 50 50 orange orange 1-pos. 2-pos. PR PR/2 30 40 55 9 30 40 63 0 50 50 orange 2-pos. PRZ 30 40 61 4 50 PSH 3-6 PSH 5-10 30 40 59 1 30 40 60 1 50 50 PC 30 40 58 8 50 Shielding, for mounting on PZ/... and PRZ, for shielded conductors with 3-6 mm-∅ 5-10 mm-∅ Coding star, with 4 coding branches, can be inserted in all base terminal blocks Recommendation for the use of optional accessories Number of positions Strain relief Snap-lock fitting 1 – 1 x PR 2-4 1 x P…/2 1 x PR/2 or 2 x PR 1 x P…/4 or 2 x P…/2 2 x PR/2 or 4 x PR 2 x P…/4 or 4 x P…/2 3 x PR/2 or 6 x PR TNR 5125812/15.03.2003-02  Phoenix Contact 5 - 10 11 - 15 Phoenix Contact page 27 of 27
3040368 价格&库存

很抱歉,暂时无法提供与“3040368”相匹配的价格&库存,您可以联系我们找货

免费人工找货
3040368
  •  国内价格 香港价格
  • 1+158.504031+19.73227

库存:30