3042829

3042829

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    TERMBLOCKPLUG1POSSTR

  • 数据手册
  • 价格&库存
3042829 数据手册
co s. nt po ne The Þelds of application for the pluggable ST-COMBI spring-cage terminal blocks has been added to with solutions for larger conductor cross sections and a higher nominal current. The product range includes both feed-through terminal blocks with one cable entry and four-wire terminal blocks with two cable entries. Ground terminal blocks with the same shape and the same pitch are available for the various base terminal blocks. Contact is made by simply snapping the terminal block onto the mounting rail. The corresponding plug types SP 4... can either be ordered ready assembled with 1-15 positions, or the individual components can be ordered for applicationspeciÞc assembly. At every connection point of a conductor to the base terminal block or connector there is a testing facility for a 2.3 mm test plug. m ST-COMBI 4 mm2 Pluggable Spring-Cage Terminal Blocks om Strain relief PZ Strain reliefs are available for the plugs which, as an option, can be snapped on the SP 4 ... connectors externally. on l in ec PZ/PRZ snap-lock Þtting The PR... snap-lock Þtting is snapped into the outside of the plug housing as an option and hooks onto the terminal block housing when the plug is snapped on. PRZ can be used when an application requires strain relief and a snap-lock Þtting. PRZ is also snapped into the plug housing as an option and offers a combination of functions in a single component. PC coding option SpeciÞc connector positions can be deÞned for all the base terminal blocks using the PC coding star. To do this, the individual branches of the coding star are inserted at the coding position in the base terminal block and the coding lug is removed at the corresponding point of the connector. Shield connection PSH PSH... provides a solution for the connection of shielded conductors. PSH... is snapped into PZ... or PRZ after the terminal blocks have been wired and is then permanently secured using a cable tie. The PSH connecting cable is connected to a connector conductor and makes contact directly with the terminal block when inserted. Phoenix Contact GmbH & Co. KG • 32823 Blomberg, Germany Phone +49 52 35 3-00 • Fax +49 52 35 3-4 12 00 • www.phoenixcontact.com Local Contact: www.phoenixcontact.com/salesnetwork Pluggable Spring-Cage Terminal Blocks ST 4/ 1P AWG I [A] U [V] 0.08-4 28-10 30* 800 IEC 61 984 0.08-6 * Derating curve see page 9. Technical data Spring-cage terminal block, for mounting on 3 terminal width 6.2 terminal width 6.2 gray Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: gray black ST 4/ 1P ST 4/ 1P BU 30 42 71 9 30 42 87 4 50 50 D-ST 4 30 30 42 0 50 0.25-0.5 mm2 0.75-1 mm2 ISH 4/0,5 ISH 4/1 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. FBS 2-6 FBS 3-6 FBS 4-6 FBS 5-6 FBS 10-6 FBS 20-6 50 50 30 30 33 6 30 30 24 2 30 30 25 5 30 30 34 9 30 30 27 1 30 30 36 5 50 50 50 50 10 10 30 30 72 1 50 PAI 4 30 30 92 5 10 MPS-RD 02 01 55 3 10 PS-6 30 30 99 6 10 PC 30 40 58 8 50 WST 4 30 30 95 4 50 SZF 1 - 0,6 x 3,5 12 04 51 7 10 white ZBF 6:UNBEDRUCKT 08 08 71 0 10 white ZB 6:UNBEDRUCKT 10 51 00 3 10 ATP-ST 4 Coding star, with 4 coding pins, for mounting in all base terminal blocks in ec Warning cover, for the actuating ducts of the "mini-spring" ST spring-cage terminal blocks om 2.3 mm ∅ test plug 1), consisting of metal part and red insulating sleeve Modular test plug, labeling with ZBF 6 po Test adapter, for 4 mm ∅ PS test plug and 4 mm ∅ safety test plugs, makes contact in the bridge shaft Screwdriver, for actuating the tension spring on l Dimensions Width / length / end cover width [mm] Height (NS 35/7,5 / NS 35/15) [mm] Technical data in accordance with IEC/ DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulating material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulating material Inßammability class in acc. with UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG 1 Imax.: 32 A 32 A 32 A 32 A 32 A 32 A ne Partition plate, for visual and electrical separation of terminal groups, 2 mm thick Zack strip, 10-section, for labeling in the terminal center Pcs. Pkt. 30 02 88 5 30 02 89 8 Plug-in bridge, for cross bridging in the terminal center Zack strip, ßat, for labeling the center and outer marker grooves Order No. nt Cover gray blue Type m ßexible stranded co rigid solid s. (IEC) [mm2] ) Further colors on request. Phoenix Contact page 2 of 10 6.2 / 55.8 / 2.2 36.5 / 44 30 / 6 6/3 III / I 0.25 - 4 0.25 - 4 0.5 - 1 10 A4 PA V0 Applied for Applied for Pluggable Spring-Cage Ground Terminal Blocks ST 4/ 1P-PE (IEC) [mm2] rigid solid ßexible stranded AWG IEC 61 984 0.08-6 0.08-4 28-10 Observe the current carrying capacity of the mounting rails. gray Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: gray black 50 D-ST 4 30 30 42 0 50 0.25-0.5 mm2 0.75-1 mm2 ISH 4/0,5 ISH 4/1 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. FBS 2-6 FBS 3-6 FBS 4-6 FBS 5-6 FBS 10-6 FBS 20-6 50 50 30 30 33 6 30 30 24 2 30 30 25 5 30 30 34 9 30 30 27 1 30 30 36 5 50 50 50 50 10 10 30 30 72 1 50 PC 30 40 58 8 50 WST 4 30 30 95 4 50 SZF 1 - 0,6 x 3,5 12 04 51 7 10 white ZBF 6:UNBEDRUCKT 08 08 71 0 10 white ZB 6:UNBEDRUCKT 10 51 00 3 10 ne Partition plate, for visual and electrical separation of terminal groups, 2 mm thick ATP-ST 4 Screwdriver, for actuating the tension spring in ec om Warning cover, for the actuating ducts of the "mini-spring" ST spring-cage terminal blocks po Coding star, with 4 coding pins, for mounting in all base terminal blocks Zack strip, 10-section, for labeling in the terminal center 30 42 72 2 30 02 88 5 30 02 89 8 Plug-in bridge, for cross bridging in the terminal center Zack strip, ßat, for labeling the center and outer marker grooves ST 4/ 1P-PE m terminal width 6.2 Pcs. Pkt. nt Cover greenyellow Order No. s. Spring-cage terminal block, for mounting on 3 Type co Technical data on l Dimensions Width / length / end cover width [mm] Height (NS 35/7,5 / NS 35/15) [mm] Technical data in accordance with IEC/ DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulating material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulating material Inßammability class in acc. with UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG Phoenix Contact page 3 of 10 6.2 / 55.8 / 2.2 36.5 / 44 – 6/3 III / I 0.25 - 4 0.25 - 4 0.5 - 1 10 A4 PA V0 Applied for Applied for Pluggable Spring-Cage Terminal Blocks ST 4-QUATTRO/ 2P (IEC) [mm2] rigid solid ßexible stranded I [A] AWG U [V] terminal width 6.2 terminal width 6.2 gray Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: gray black Plug-in bridge, for cross bridging in the terminal center 30 43 74 7 50 30 43 75 0 50 30 02 88 5 30 02 89 8 50 50 Imax.: 32 A 32 A 32 A 32 A 32 A 32 A 30 30 33 6 30 30 24 2 30 30 25 5 30 30 34 9 30 30 27 1 30 30 36 5 50 50 50 50 10 10 ATP-ST QUATTRO 30 30 81 5 50 PAI 4 30 30 92 5 10 MPS-RD 02 01 55 3 10 PS-6 30 30 99 6 10 PC 30 40 58 8 50 WST 4 30 30 95 4 50 ISH 4/0,5 ISH 4/1 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. FBS 2-6 FBS 3-6 FBS 4-6 FBS 5-6 FBS 10-6 FBS 20-6 po Warning cover, for the actuating ducts of the "mini-spring" ST spring-cage terminal blocks Screwdriver, for actuating the tension spring on l D-ST 4-QUATTRO/ 2P 0.25-0.5 mm2 0.75-1 mm2 in ec Coding star, with 4 coding pins, for mounting in all base terminal blocks 50 50 DS-ST 4/P om 2.3 mm ∅ test plug 1), consisting of metal part and red insulating sleeve Modular test plug, labeling with ZBF 6 30 42 84 5 30 42 86 1 gray Partition plate, for visual and electrical separation of terminal groups, 2 mm thick Test adapter, for 4 mm ∅ PS test plug and 4 mm ∅ safety test plugs, makes contact in the bridge shaft ST 4-QUATTRO/ 2P ST 4-QUATTRO/ 2P BU nt End cover segment, serves for covering multi-conductor terminal blocks when twoconductor terminal blocks are aligned Pcs. Pkt. ne Cover gray blue Order No. m Spring-cage terminal block, for mounting on 3 Type co Technical data s. IEC 61 984 0.08-6 0.08-4 28-10 30 1)* 800 1) The max. load current must not be exceeded by the total current of all connected conductors. * Derating curve see page 9. SZF 1 - 0,6 x 3,5 12 04 51 7 10 Zack strip, ßat, for center and external labeling white ZBF 6:UNBEDRUCKT 08 08 71 0 10 Zack strip, 10-section, for labeling in the terminal center white ZB 6:UNBEDRUCKT 10 51 00 3 10 Dimensions Width / length / end cover width [mm] Height (NS 35/7,5 / NS 35/15) [mm] Technical data in accordance with IEC/ DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulating material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulating material Inßammability class in acc. with UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG 1 ) Further colors on request. Phoenix Contact page 4 of 10 6.2 / 97.3 / 2.2 36.5 / 44 30 / 6 6/3 III / I 0.25 - 4 0.25 - 4 0.5 - 1 10 A4 PA V0 Applied for Applied for Pluggable Spring-Cage Ground Terminal Blocks ST 4-QUATTRO/ 2P-PE (IEC) [mm2] rigid solid ßexible stranded AWG IEC 61 984 0.08-6 0.08-4 28-10 Observe the current carrying capacity of the mounting rails. gray Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: gray black Plug-in bridge, for cross bridging in the terminal center Zack strip, ßat, for labeling the center and outer marker grooves 50 30 43 75 0 50 30 02 88 5 30 02 89 8 50 50 30 30 33 6 30 30 24 2 30 30 25 5 30 30 34 9 30 30 27 1 30 30 36 5 50 50 50 50 10 10 ATP-ST QUATTRO 30 30 81 5 50 PC 30 40 58 8 50 WST 4 30 30 95 4 50 SZF 1 - 0,6 x 3,5 12 04 51 7 10 ZBF 6:UNBEDRUCKT 08 08 71 0 10 ZB 6:UNBEDRUCKT 10 51 00 3 10 ISH 4/0,5 ISH 4/1 2-pos. 3-pos. 4-pos. 5-pos. 10-pos. 20-pos. FBS 2-6 FBS 3-6 FBS 4-6 FBS 5-6 FBS 10-6 FBS 20-6 po white on l Zack strip, 10-section, for labeling in the terminal center 30 43 74 7 0.25-0.5 mm2 0.75-1 mm2 in ec Screwdriver, for actuating the tension spring D-ST 4-QUATTRO/ 2P DS-ST 4/P om Warning cover, for the actuating ducts of the "mini-spring" ST spring-cage terminal blocks 50 gray Partition plate, for visual and electrical separation of terminal groups, 2 mm thick Coding star, with 4 coding pins, for mounting in all base terminal blocks 30 42 85 8 nt End cover segment, serves for covering multi-conductor terminal blocks when twoconductor terminal blocks are aligned ST 4-QUATTRO/ 2P-PE white m terminal width 6.2 Pcs. Pkt. ne Cover greenyellow Order No. co Spring-cage terminal block, for mounting on 3 Type s. Technical data Dimensions Width / length / end cover width [mm] Height (NS 35/7,5 / NS 35/15) [mm] Technical data in accordance with IEC/ DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulating material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulating material Inßammability class in acc. with UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG Phoenix Contact page 5 of 10 6.2 / 97.3 / 2.2 36.5 / 44 – 6/3 III / I 0.25 - 4 0.25 - 4 0.5 - 1 10 A4 PA V0 Applied for Applied for ST-COMBI Plugs SP 4 AWG I [A] U [V] 0.08-4 28-10 30* 800 Technical data 0.25-0.5 mm2 0.75-1 mm2 Strain relief, Snap-lock Þtting and strain relief for all plugs 2-pos. orange orange 1-pos. 2-pos. 2-pos. in ec orange Shielding, for mounting on PZ/... and PRZ, for shielded conductors with 50 50 50 50 50 25 25 25 25 25 10 10 10 10 10 30 02 88 5 30 02 89 8 50 50 PZ/2 30 40 62 7 50 PR PR/2 30 40 55 9 30 40 63 0 50 50 PRZ 30 40 61 4 50 3-6 mm ∅ 5-10 mm ∅ PSH 3-6 PSH 5-10 30 40 59 1 30 40 60 1 50 50 white ZBF 6:UNBEDRUCKT 08 08 71 0 10 on l Zack strip, ßat, for labeling the outer marker grooves 30 42 88 7 30 42 89 0 30 42 90 0 30 42 92 6 30 42 93 9 30 42 94 2 30 42 95 5 30 42 96 8 30 42 97 1 30 42 98 4 30 42 99 7 30 43 00 6 30 43 37 8 30 43 72 1 30 43 73 4 ISH 4/0,5 ISH 4/1 om Snap-lock Þtting, for all plugs black SP 4/1 SP 4/2 SP 4/3 SP 4/4 SP 4/5 SP 4/6 SP 4/7 SP 4/8 SP 4/9 SP 4/10 SP 4/11 SP 4/12 SP 4/13 SP 4/14 SP 4/15 nt Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: gray black 1-pos. 2-pos. 3-pos. 4-pos. 5-pos. 6-pos. 7-pos. 8-pos. 9-pos. 10-pos. 11-pos. 12-pos. 13-pos. 14-pos. 15-pos. Pcs. Pkt. ne gray gray gray gray gray gray gray gray gray gray gray gray gray gray gray Order No. po ST-COMBI plug, single, not bridgeable, 6.2 mm wide Type m Connection data 0.08-6 * Derating curve see page 9. ßexible stranded co rigid solid s. (IEC) [mm2] Technical data in accordance with IEC/ DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulating material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulating material Inßammability class in acc. with UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG Phoenix Contact page 6 of 10 30 / 6 8/3 III / I 0.25 - 4 0.25 - 4 0.5 - 1 10 A4 PA V0 Applied for Applied for ST-COMBI Plugs for Self-Assembly co m Structure of a plug For each multiple-position plug, a left element (at the beginning of the plug) and a right element (at the end of the plug) is required. How many middle elements need to be inserted depends on the number of positions of the desired plug. The individual elements are connected by pushing them together and are held by the engagement pins. Example for the structure of a 6-position plug: nt s. Withden Mit theselbstkonfektionierbaren ST-COMBI plugs for self-assembly, ST-COMBI-Steckern we offer a ist für jede solution for Aufgabenstellung every task and it can einebeLösung implemented vorhanden, by the die vom user himself. Anwender The plug selbst is assembled realisiert werden directlykann. on site Der by Stecker wird snapping together hierbeione-position direkt vor Ort plug anwendungsgerecht elements. aus einpoligen Steckerelementen zusammengerastet. For the existing SP 4… plug a one-position base version Für die vorhandenen is available in Steckertypen gray, blue andSP green-yellow: 2,5…, SPB 2,5… und SPDB 2,5… stehen jeweils einpolige Grundvarianten in den Farben grau, blau, grün-gelb zur Verfügung: SP 4/1-L om po ne left element SP…4/1-L left side: smooth right side: open on l in ec middle element SP…4/1-M left side: engagement pin right side: open right element SP…4/1-R left side: engagement pin right side: end cover In this view, the open side of the plug is on the right. The different color versions can be combined with each other in any order. Phoenix Contact page 7 of 10 SP 4/1-M SP 4/1-M BU SP 4/1-R GNYE Plugs for Self-Assembly SP 4/1… (IEC) [mm2] rigid solid Connection data 0.08-6 * Derating curve see page 9. ßexible stranded AWG I [A] U [V] 0.08-4 28-10 30* 800 Technical data Type Order No. Pcs. Pkt. gray blue green-yellow SP 4/1-L SP 4/1-L BU SP 4/1-L GNYE 30 42 75 1 30 42 76 4 30 42 77 7 50 50 50 ST-COMBI plug, single, not bridgeable, 6.2 mm wide, middle element gray blue green-yellow SP 4/1-M SP 4/1-M BU SP 4/1-M GNYE 30 42 78 0 30 42 79 3 30 42 80 3 50 50 50 ST-COMBI plug, single, not bridgeable, 6.2 mm wide, right element gray blue green-yellow SP 4/1-R SP 4/1-R BU SP 4/1-R GNYE 30 42 81 6 30 42 82 9 30 42 83 2 50 50 50 black 2-pos. PZ/2 30 40 62 7 50 orange orange 1-pos. 2-pos. PR PR/2 30 40 55 9 30 40 63 0 50 50 orange 2-pos. PRZ 30 40 61 4 50 PSH 3-6 PSH 5-10 30 40 59 1 30 40 60 1 50 50 ZBF 6:UNBEDRUCKT 08 08 71 0 10 Shielding, for mounting on PZ/... and PRZ, for shielded conductors with Zack strip, for labeling the outer marker grooves 3-6 mm∅ 5-10 mm ∅ white co nt ne Snap-lock Þtting and strain relief for all plugs po Snap-lock Þtting, for all plugs s. Strain relief, m ST-COMBI plug, single, not bridgeable, 6.2 mm wide, left element on l in ec om Technical data in accordance with IEC/ DIN VDE Maximum load current / cross section [A] / [mm2] Rated surge voltage / contamination class [kV] / – Surge voltage category / insulating material group –/– Connection capacity Stranded with ferrule with plastic sleeve [mm2] Stranded with ferrule without plastic sleeve [mm2] Stranded with TWIN ferrule with plastic sleeve [mm2] Stripping length [mm] Internal cylindrical gauge (IEC 60 947-1) Insulating material Inßammability class in acc. with UL 94 Approval data (UL and CSA/CUL) Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG CSA/CUL: [V] / [A] / AWG Phoenix Contact page 8 of 10 30 / 6 8/3 III / I 0.25 - 4 0.25 - 4 0.5 - 1 10 A4 PA V0 Applied for Applied for Derating curve for ST-COMBITerminal Blocks Max. load current [A] ! # !  2-pos. 5-pos. # 10-pos. 15-pos.   #     "  $  &      m #  co Ambient temperature[°C] s. Derating curve for ST 4/1P. Is valid for all connector versions SP... . nt ne !  2-pos. 5-pos. # po 10-pos. 15-pos.  om  #     in ec # "  $  &       Ambient temperature [°C] Derating curve for ST 4-QUATTRO/ 2P. Is valid for all connector versions SP... . on l Max. load current [A] ! # Phoenix Contact page 9 of 10 Additional technical data ≤ 3.2 mV ≤ 45 K Immunity to vibration (DIN EN 60 068-2-6:1996-05) - Frequency - Amplitude - Acceleration - Duration per axis 10-150 Hz 0.35 mm (10-60 Hz) 50 m/s2 2.5 h Resistance to industrial atmospheres (DIN 50 018:1997-06) - Level - No. of cycles KFW 1.0 S 2 Assessment of Þre risk ( DIN EN 60 695-2-11/VDE 0471 Part 2-11:2001-11) - Test temperature - Duration 960°C 30 s TNR: 101429-00-en/15.03.04  Phoenix Contact 2004 on l in ec om po ne nt s. co m Voltage drop over two terminal points (DIN EN 60 947-7-1/2) Rise in temperature (DIN EN 60 947-7-1/2) Phoenix Contact page 10 of 10
3042829 价格&库存

很抱歉,暂时无法提供与“3042829”相匹配的价格&库存,您可以联系我们找货

免费人工找货
3042829
  •  国内价格 香港价格
  • 50+29.9855750+3.87385

库存:0