Test disconnect terminal block - RT 5-T - 3049039
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Test disconnect terminal block, Connection type: Bolt connection, Cross section: 0.1 mm² - 6 mm², AWG: 26 - 10,
Nominal current: 41 A, Nominal voltage: 1000 V, Length: 91.4 mm, Width: 16.3 mm, Color: gray, Assembly: NS
35/7,5, NS 35/15
Product Features
■
■
■
■
■
■
■
■
■
The special clamping nuts can be actuated with a normal screwdriver
Quick and easy connection thanks to hinged cover flaps which hold the clamping nuts captive. When the flaps are open, the connection bolt is
freely accessible and the cable lugs can be hooked in; after closing and engaging the flaps
Easy bridging and potential distribution using the patented plug-in bridges from the CLIPLINE complete system
The screws are secured against loosening by captive spring-loaded spacers
Large-surface labeling options in the terminal center and above the terminal points
The use of the switching lock effectively prevents unintentional switching
The hinged cover cover the live metal parts including the insulated cable lugs in the clamping area so that they are touch proof
Testing with the standardized test adapters and test plugs of the CLIPLINE complete system
Tested for railway applications
Key Commercial Data
Packing unit
50 pc
Minimum order quantity
25 pc
Weight per Piece (excluding packing)
50.056 g
Custom tariff number
85369010
Country of origin
China
Technical data
General
Note
Note: the BE-RT... path extension is to be used for non-insulated cable
lugs (see accessories).
Number of levels
1
Number of connections
2
03/14/2016 Page 1 / 7
https://www.phoenixcontact.com/us/products/3049039
Test disconnect terminal block - RT 5-T - 3049039
Technical data
General
Nominal cross section
6 mm²
Color
gray
Insulating material
PA
Flammability rating according to UL 94
V0
Area of application
Railway industry
Mechanical engineering
Plant engineering
Rated surge voltage
6 kV
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Connection in acc. with standard
IEC 60947-7-1
Maximum load current
41 A (with 6 mm² conductor cross section)
Nominal current IN
41 A
Nominal voltage UN
1000 V (Rated voltage for open disconnect point 500 V)
Open side panel
Yes
Shock protection test specification
DIN EN 50274 (VDE 0660-514):2002-11
Back of the hand protection
guaranteed
Finger protection
guaranteed
Result of surge voltage test
Test passed
Surge voltage test setpoint
7.3 kV
Result of power-frequency withstand voltage test
Test passed
Power frequency withstand voltage setpoint
1.89 kV
Result of the test for mechanical stability of terminal points (5 x conductor
connection)
Test passed
Result of tight fit on support
Test passed
Tight fit on carrier
NS 35
Setpoint
5N
Result of voltage-drop test
Test passed
Result of temperature-rise test
Test passed
Short circuit stability result
Test passed
Conductor cross section short circuit testing
6 mm²
Short-time current
0.72 kA
Result of thermal test
Test passed
Proof of thermal characteristics (needle flame) effective duration
30 s
Oscillation, broadband noise test result
Test passed
Test specification, oscillation, broadband noise
DIN EN 50155 (VDE 0115-200):2008-03
03/14/2016 Page 2 / 7
https://www.phoenixcontact.com/us/products/3049039
Test disconnect terminal block - RT 5-T - 3049039
Technical data
General
Test spectrum
Service life test category 1, class B, body mounted
Test frequency
f1 = 5 Hz to f2 = 150 Hz
ASD level
0.02 g²/Hz
Acceleration
0.8g
Test duration per axis
5h
Test directions
X-, Y- and Z-axis
Shock test result
Test passed
Test specification, shock test
DIN EN 50155 (VDE 0115-200):2008-03
Shock form
Half-sine
Acceleration
5g
Shock duration
30 ms
Number of shocks per direction
3
Test directions
X-, Y- and Z-axis (pos. and neg.)
Relative insulation material temperature index (Elec., UL 746 B)
130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 120 °C
Dimensions
Width
16.3 mm
End cover width
2.2 mm
Length
91.4 mm
Height NS 35/7,5
51 mm
Height NS 35/15
58.5 mm
Connection data
Note
Connection bolts
Connection method
Bolt connection
Connection in acc. with standard
IEC 60947-7-1
Conductor cross section solid min.
0.1 mm²
Conductor cross section solid max.
6 mm²
Conductor cross section AWG min.
26
Conductor cross section AWG max.
10
Conductor cross section flexible min.
0.1 mm²
Conductor cross section flexible max.
6 mm²
Min. AWG conductor cross section, flexible
26
Max. AWG conductor cross section, flexible
10
Cable lug connection according to standard
DIN 46 234
Min. cross section for cable lug connection
0.5 mm²
Max. cross section for cable lug connection
6 mm²
03/14/2016 Page 3 / 7
https://www.phoenixcontact.com/us/products/3049039
Test disconnect terminal block - RT 5-T - 3049039
Technical data
Connection data
Hole diameter, min.
5.3 mm
Cable lug width, max.
10 mm
Bolt diameter
5 mm
Cable lug connection according to standard
DIN 46237
Min. cross section for cable lug connection
1 mm²
Max. cross section for cable lug connection
6 mm²
Hole diameter, min.
5.3 mm
Cable lug width, max.
10 mm
Bolt diameter
5 mm
Screw thread
M5
Tightening torque, min
2.5 Nm
Tightening torque max
3 Nm
Screw thread
M4
Tightening torque, min
1.5 Nm
Tightening torque max
1.8 Nm
Standards and Regulations
Connection in acc. with standard
CUL
IEC 60947-7-1
DIN 46 234
DIN 46237
Flammability rating according to UL 94
V0
Classifications
eCl@ss
eCl@ss 4.0
27141126
eCl@ss 4.1
27141126
eCl@ss 5.0
27141126
eCl@ss 5.1
27141126
eCl@ss 6.0
27141126
eCl@ss 7.0
27141126
eCl@ss 8.0
27141126
ETIM
ETIM 2.0
EC000902
ETIM 3.0
EC000902
ETIM 4.0
EC000902
03/14/2016 Page 4 / 7
https://www.phoenixcontact.com/us/products/3049039
Test disconnect terminal block - RT 5-T - 3049039
Classifications
ETIM
ETIM 5.0
EC000902
UNSPSC
UNSPSC 6.01
30211811
UNSPSC 7.0901
39121410
UNSPSC 11
39121410
UNSPSC 12.01
39121410
UNSPSC 13.2
39121410
Approvals
Approvals
Approvals
UL Recognized / cUL Recognized / EAC / ABS / EAC / cULus Recognized
Ex Approvals
Approvals submitted
Approval details
UL Recognized
B
C
Nominal current IN
30 A
30 A
Nominal voltage UN
600 V
600 V
B
C
Nominal current IN
30 A
30 A
Nominal voltage UN
600 V
600 V
cUL Recognized
03/14/2016 Page 5 / 7
https://www.phoenixcontact.com/us/products/3049039
Test disconnect terminal block - RT 5-T - 3049039
Approvals
EAC
ABS
EAC
cULus Recognized
Drawings
Circuit diagram
Connection diagram
1
2
1
2
1
2
1
2
k
l
k
l
k
l
k
l
a
b
c
d
Simple current transformer test circuit
a = normal operation
b = measured value testing
c = transformer testing
d = relay testing
03/14/2016 Page 6 / 7
https://www.phoenixcontact.com/us/products/3049039
Test disconnect terminal block - RT 5-T - 3049039
Connection diagram
Connection diagram
1
2
3
4
5
6
1
2
3
4
5
6
k
l
k
l
k
l
k
k
k
l
l
l
L1
L1
L2
L2
L3
L3
Three-phase transducer test set
Three-phase linked transducer test set
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
03/14/2016 Page 7 / 7