https://www.phoenixcontact.com/us/products/3214014
Potential distributors - PTU 16/14X2,5 BU - 3214014
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Potential distributors, Connection method: Push-in connection, Cross section: 1 mm² - 2.5 mm², AWG: 18 - 14,
Width: 17.5 mm, Color: blue, Mounting type: NS 35/7,5, NS 35/15
Product Features
■
■
■
■
The terminal block base is ideal for use in building installation and machine building applications
The Push-in connection terminal blocks are characterized by the system features of the CLIPLINE complete system and by easy and tool-free
wiring of conductors with ferrules or solid conductors
The compact design and front connection enable wiring in a confined space
In addition to the testing facility in the double function shaft, all terminal blocks provide an additional test connection
Key Commercial Data
Packing unit
1 pc
Minimum order quantity
10 pc
Weight per Piece (excluding packing)
41.0 g
Custom tariff number
85369010
Country of origin
Germany
Technical data
General
Number of levels
1
Number of connections
15
Color
blue
Insulating material
PA
Flammability rating according to UL 94
V0
Rated surge voltage
8 kV
Degree of pollution
2
Overvoltage category
III
Insulating material group
I
03/13/2016 Page 1 / 5
https://www.phoenixcontact.com/us/products/3214014
Potential distributors - PTU 16/14X2,5 BU - 3214014
Technical data
General
Connection method
Push-in connection
Connection in acc. with standard
VDE 0609, Part 1/EN 60999-1
Maximum load current
25 A (The sum of the individual currents may not exceed the max. value of
80 A)
Nominal current IN
25 A (The sum of the individual currents may not exceed the max. value of
80 A)
Nominal voltage UN
1000 V
Connection method
Screw connection
Connection in acc. with standard
VDE 0609, Part 1/EN 60999-1
Maximum load current
80 A (with 25 mm² conductor cross section)
Nominal current IN
80 A (with 16 mm² conductor cross section)
Nominal voltage UN
1000 V
Open side panel
Yes
Dimensions
Width
17.5 mm
Length
89.5 mm
Height NS 35/7,5
36 mm
Height NS 35/15
43.5 mm
Connection data
Connection method
Push-in connection
Connection in acc. with standard
VDE 0609, Part 1/EN 60999-1
Conductor cross section solid min.
1 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section AWG min.
18
Conductor cross section AWG max.
14
Conductor cross section flexible, with ferrule without plastic sleeve min.
0.75 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
1.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.
0.75 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
1.5 mm²
Nominal current IN
25 A (The sum of the individual currents may not exceed the max. value of
80 A)
Maximum load current
25 A (The sum of the individual currents may not exceed the max. value of
80 A)
Nominal voltage UN
1000 V
Internal cylindrical gage
A3
Connection method
Screw connection
Connection in acc. with standard
VDE 0609, Part 1/EN 60999-1
03/13/2016 Page 2 / 5
https://www.phoenixcontact.com/us/products/3214014
Potential distributors - PTU 16/14X2,5 BU - 3214014
Technical data
Connection data
Screw thread
M5
Tightening torque, min
2 Nm
Tightening torque max
3 Nm
Stripping length
12 mm
Conductor cross section solid min.
1.5 mm²
Conductor cross section solid max.
25 mm²
Conductor cross section AWG min.
16
Conductor cross section AWG max.
4
Conductor cross section flexible min.
1 mm²
Conductor cross section flexible max.
16 mm²
Min. AWG conductor cross section, flexible
18
Max. AWG conductor cross section, flexible
6
Conductor cross section flexible, with ferrule without plastic sleeve min.
1 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
16 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.
1 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.
16 mm²
2 conductors with same cross section, solid min.
1.5 mm²
2 conductors with same cross section, solid max.
10 mm²
2 conductors with same cross section, stranded min.
1.5 mm²
2 conductors with same cross section, stranded max.
6 mm²
2 conductors with same cross section, stranded, ferrules without plastic
sleeve, min.
1.5 mm²
2 conductors with same cross section, stranded, ferrules without plastic
sleeve, max.
6 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic
1.5 mm²
sleeve, min.
2 conductors with same cross section, stranded, TWIN ferrules with plastic
6 mm²
sleeve, max.
Nominal current IN
80 A (with 16 mm² conductor cross section)
Maximum load current
80 A (with 25 mm² conductor cross section)
Nominal voltage UN
1000 V
Standards and Regulations
Connection in acc. with standard
VDE 0609, Part 1/EN 60999-1
VDE 0609, Part 1/EN 60999-1
Flammability rating according to UL 94
V0
03/13/2016 Page 3 / 5
https://www.phoenixcontact.com/us/products/3214014
Potential distributors - PTU 16/14X2,5 BU - 3214014
Classifications
eCl@ss
eCl@ss 4.0
27141127
eCl@ss 4.1
27141127
eCl@ss 5.0
27141127
eCl@ss 5.1
27141111
eCl@ss 6.0
27141148
eCl@ss 7.0
27141148
eCl@ss 8.0
27141120
eCl@ss 9.0
27141120
ETIM
ETIM 3.0
EC000897
ETIM 4.0
EC000897
ETIM 5.0
EC000897
UNSPSC
UNSPSC 6.01
30211812
UNSPSC 7.0901
39121410
UNSPSC 11
39121411
UNSPSC 12.01
39121411
UNSPSC 13.2
39121411
Approvals
Approvals
Approvals
EAC / EAC
Ex Approvals
Approvals submitted
Approval details
EAC
03/13/2016 Page 4 / 5
https://www.phoenixcontact.com/us/products/3214014
Potential distributors - PTU 16/14X2,5 BU - 3214014
Approvals
EAC
Drawings
Circuit diagram
1
12
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com