PTFIX 6/12X2,5-NS15A GN - Distribution block
3274196
https://www.phoenixcontact.com/us/products/3274196
Please be informed that the data shown in this PDF document is generated from our online catalog. Please find the complete data in the user
documentation. Our general terms of use for downloads are valid.
Distribution block, Block with horizontal alignment and integrated supply, nom. voltage: 690 V, nominal current: 24 A, number of
connections: 13, connection method: Push-in connection, Load contact, cross section: 0.14 mm2 - 4 mm2, Push-in connection, Line
contact, Rated cross section: 6 mm2, cross section: 0.5 mm2 - 10 mm2, mounting type: NS 15, color: green
Your advantages
• Space savings of up to 50 % on the DIN rail, thanks to transverse mounting
• Flexible use, thanks to DIN rail mounting, direct mounting or adhesive mounting
• Time-saving conductor connection, thanks to tool-free Push-in direct connection technology
• Time savings of up to 80 %, thanks to ready-to-mount blocks without manual bridging
• Clear wiring, thanks to eleven different color variants
Commercial data
Item number
3274196
Packing unit
1 pc
Minimum order quantity
8 pc
Sales key
BE09
Product key
BEA123
Catalog page
Page 445 (C-1-2019)
GTIN
4055626393933
Weight per piece (including packing)
33.512 g
Weight per piece (excluding packing)
33.512 g
Customs tariff number
85369010
Country of origin
PL
Jan 8, 2024, 10:58 AM
Page 1 (10)
PTFIX 6/12X2,5-NS15A GN - Distribution block
3274196
https://www.phoenixcontact.com/us/products/3274196
Technical data
Notes
General
the blocks can be bridged with one another via the conductor
shaft, for corresponding plug-in bridges, see accessories
General
Note
The maximum load current of a single clamping unit must not be
exceeded.
For power distribution applications, IEC 60364-4-43.2008;
modified + corrigendum Okt. 2008 (DIN VDE 0100-430:2010-10)
section 433.2 ff must be observed!
Product properties
Product type
Distributor terminal block
Number of connections
13
Number of rows
1
Potentials
1
Insulation characteristics
Overvoltage category
III
Degree of pollution
3
Electrical properties
Rated surge voltage
8 kV
Maximum power dissipation for nominal condition
0.77 W
Connection data
Service Entrance
yes
Number of connections per level
13
Nominal cross section
2.5 mm²
Rated cross section AWG
14
Load contact
Stripping length
8 mm ... 10 mm
Internal cylindrical gage
A3
Connection in acc. with standard
IEC 60947-7-1
Conductor cross section rigid
0.14 mm² ... 4 mm²
Cross section AWG
26 ... 12 (converted acc. to IEC)
Conductor cross section flexible
0.14 mm² ... 2.5 mm²
Conductor cross section, flexible [AWG]
26 ... 14 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
0.14 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
0.14 mm² ... 2.5 mm²
Nominal current
24 A
Maximum load current
32 A (with 4 mm² conductor cross section)
Maximum total current
57 A (with 10 mm² conductor cross section)
Jan 8, 2024, 10:58 AM
Page 2 (10)
PTFIX 6/12X2,5-NS15A GN - Distribution block
3274196
https://www.phoenixcontact.com/us/products/3274196
Nominal voltage
690 V
Line contact
Stripping length
10 mm ... 12 mm
Connection in acc. with standard
IEC 60947-7-1
Conductor cross section rigid
0.5 mm² ... 10 mm²
Cross section AWG
20 ... 8 (converted acc. to IEC)
Conductor cross section flexible
0.5 mm² ... 10 mm²
Conductor cross section, flexible [AWG]
20 ... 10 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
0.5 mm² ... 6 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
0.5 mm² ... 6 mm²
Conductor cross-section flexible (2 conductors with the same
cross-section, with TWIN ferrule and plastic sleeve)
0.5 mm² ... 1.5 mm²
2 conductors with the same cross section, flexible, with TWIN
ferrule with plastic sleeve
0.5 mm² ... 1.5 mm²
Nominal current
41 A (with 6 mm² conductor cross section)
Maximum load current
57 A (with 10 mm² conductor cross section)
Nominal cross section
6 mm²
Load contact Connection cross sections directly pluggable
Conductor cross section rigid
0.34 mm² ... 4 mm²
Conductor cross section, rigid [AWG]
24 ... 12 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
0.34 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
0.34 mm² ... 2.5 mm²
Line contact Connection cross sections directly pluggable
Conductor cross section rigid
1 mm² ... 10 mm²
Conductor cross-section flexible (ferrule without plastic sleeve)
1 mm² ... 6 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
1 mm² ... 6 mm²
Dimensions
Width
41 mm
Height
28.6 mm
Depth on NS 15
31.4 mm
Material specifications
Color
green
Flammability rating according to UL 94
V0
Insulating material group
I
Insulating material
PA
Static insulating material application in cold
-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE
0304-21))
130 °C
Relative insulation material temperature index (Elec., UL 746 B)
130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Jan 8, 2024, 10:58 AM
Page 3 (10)
PTFIX 6/12X2,5-NS15A GN - Distribution block
3274196
https://www.phoenixcontact.com/us/products/3274196
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354)
28 MJ/kg
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Electrical tests
Surge voltage test
Test voltage setpoint
9.8 kV
Result
Test passed
Temperature-rise test
Requirement temperature-rise test
Increase in temperature ≤ 45 K
Result
Test passed
Short-time withstand current 6 mm²
0.72 kA
Short-time withstand current 10 mm²
1.2 kA
Result
Test passed
Power-frequency withstand voltage
Test voltage setpoint
1.89 kV
Result
Test passed
Mechanical properties
Mechanical data
Open side panel
No
Mechanical tests
Mechanical strength
Result
Test passed
Attachment on the carrier
DIN rail/fixing support
NS 35
Test force setpoint
5N
Result
Test passed
Note
When aligning several blocks, it is recommended to either place
a DIN rail adapter underneath the connection point or a flange
element between the blocks.
For versions with 6 or 7 connections, it is enough to place one
DIN rail adapter centrally per block and place flange elements
after every other block.
When using the DIN rail adapter PTFIX-NS35, an aligned block
must not protrude by more than a half.
Test for conductor damage and slackening
Rotation speed
10 rpm
Jan 8, 2024, 10:58 AM
Page 4 (10)
PTFIX 6/12X2,5-NS15A GN - Distribution block
3274196
https://www.phoenixcontact.com/us/products/3274196
Revolutions
135
Conductor cross section/weight
0.5 mm² / 0.3 kg
6 mm² / 1.4 kg
10 mm² / 2 kg
Result
Test passed
Test for conductor damage and slackening
Rotation speed
10 rpm
Revolutions
135
Conductor cross section/weight
0.14 mm² / 0.2 kg
2.5 mm² / 0.7 kg
4 mm² / 0.9 kg
Result
Test passed
Environmental and real-life conditions
Aging
Temperature cycles
192
Result
Test passed
Needle-flame test
Time of exposure
30 s
Result
Test passed
Oscillation/broadband noise
Specification
DIN EN 50155 (VDE 0115-200):2008-03
Spectrum
Service life test category 2, bogie-mounted
Frequency
f1 = 5 Hz to f2 = 250 Hz
ASD level
6.12 (m/s²)²/Hz
Acceleration
3.12g
Test duration per axis
5h
Test directions
X-, Y- and Z-axis
Result
Test passed
Shocks
Specification
DIN EN 50155 (VDE 0115-200):2008-03
Pulse shape
Half-sine
Acceleration
30g
Shock duration
18 ms
Number of shocks per direction
3
Test directions
X-, Y- and Z-axis (pos. and neg.)
Result
Test passed
Ambient conditions
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to
+70 °C)
Ambient temperature (assembly)
-5 °C ... 70 °C
Jan 8, 2024, 10:58 AM
Page 5 (10)
PTFIX 6/12X2,5-NS15A GN - Distribution block
3274196
https://www.phoenixcontact.com/us/products/3274196
Ambient temperature (actuation)
-5 °C ... 70 °C
Permissible humidity (storage/transport)
30 % ... 70 %
Standards and regulations
Connection in acc. with standard
IEC 60947-7-1
IEC 60947-7-1
Mounting
Mounting type
NS 15
Jan 8, 2024, 10:58 AM
Page 6 (10)
PTFIX 6/12X2,5-NS15A GN - Distribution block
3274196
https://www.phoenixcontact.com/us/products/3274196
Approvals
To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/3274196
DNV
Approval ID: TAE00002TT-04
Nominal voltage UN
Nominal current IN
Cross section AWG
Cross section mm2
500 V
24 A
-
-
Nominal voltage UN
Nominal current IN
Cross section AWG
Cross section mm2
Output
300 V
20 A
26 - 12
-
Input
300 V
50 A
20 - 8
-
Output
300 V
20 A
26 - 12
-
Input
300 V
50 A
20 - 8
-
600 V
5A
20 - 8
-
Nominal voltage UN
Nominal current IN
Cross section AWG
Cross section mm2
690 V
41 A
-
-
Nominal voltage UN
Nominal current IN
Cross section AWG
Cross section mm2
Output
300 V
20 A
26 - 12
-
Input
300 V
50 A
20 - 8
-
Output
300 V
20 A
26 - 12
-
Input
300 V
50 A
20 - 8
-
Output
600 V
5A
26 - 12
-
Input
600 V
5A
20 - 8
-
CSA
Approval ID: 13631
Use group B
Use group C
Use group D
Input
IECEE CB Scheme
Approval ID: DE1-62701
EAC
Approval ID: RU C-DE.BL08.B.00644
cULus Recognized
Approval ID: E60425
Use group B
Use group C
Use group D
Jan 8, 2024, 10:58 AM
Page 7 (10)
PTFIX 6/12X2,5-NS15A GN - Distribution block
3274196
https://www.phoenixcontact.com/us/products/3274196
LR
Approval ID: LR2002627TA
BV
Approval ID: 59146/A0 BV
VDE Zeichengenehmigung
Approval ID: 40047797
Nominal voltage UN
Nominal current IN
Cross section AWG
Cross section mm2
690 V
41 A
-
-
Jan 8, 2024, 10:58 AM
Page 8 (10)
PTFIX 6/12X2,5-NS15A GN - Distribution block
3274196
https://www.phoenixcontact.com/us/products/3274196
Classifications
ECLASS
ECLASS-11.0
27141120
ECLASS-13.0
27250118
ETIM
ETIM 9.0
EC000897
UNSPSC
UNSPSC 21.0
39121400
Jan 8, 2024, 10:58 AM
Page 9 (10)
PTFIX 6/12X2,5-NS15A GN - Distribution block
3274196
https://www.phoenixcontact.com/us/products/3274196
Environmental product compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Phoenix Contact 2024 © - all rights reserved
https://www.phoenixcontact.com
Phoenix Contact USA
586 Fulling Mill Road
Middletown, PA 17057, United States
(+717) 944-1300
info@phoenixcon.com
Jan 8, 2024, 10:58 AM