3969928

3969928

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    TESTTERMINALSTRIP14POS

  • 数据手册
  • 价格&库存
3969928 数据手册
https://www.phoenixcontact.com/us/products/3969928 Test terminal strip - RSCWE 6-3/14 - 3969928 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Test terminal strip, Connection method: Ring cable lug, Number of connections: 28, Number of positions: 14, Width: 146.7 mm, Height: 70.1 mm, Color: gray, Mounting type: Wall mounting Why buy this product  Cost-effective, thanks to the tailored, modular design and use of standardized CLIPLINE complete accessories  Space saving, thanks to compact, modular test terminal strips  The integrated, robust switch contact is designed for the most stringent demands, and the use of high-quality materials ensures the transmission of signal currents, even after multiple actuations  Maximum safety with leading and automatic transformer short circuit Key Commercial Data Packing unit 1 STK GTIN GTIN 4055626127712 Weight per Piece (excluding packing) 580.000 g Custom tariff number 85366990 Country of origin Poland Technical data General Number of positions 14 Number of levels 1 Number of connections 28 Potentials 14 Nominal cross section 6 mm² Color gray Insulating material PA Flammability rating according to UL 94 V0 Rated surge voltage 4 kV 03/08/2017   Page 1 / 6 https://www.phoenixcontact.com/us/products/3969928 Test terminal strip - RSCWE 6-3/14 - 3969928 Technical data General Overvoltage category III Insulating material group I Maximum power dissipation for nominal condition 1.31 W Ambient temperature (operation) -60 °C ... 100 °C Maximum load current 30 A (with 10 mm² conductor cross section) Current Ith 24 A Nominal voltage UN 400 V AC/DC Open side panel No Terminal block mounting 0.8 Nm ... 1 Nm Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11 Back of the hand protection guaranteed Result of surge voltage test Test passed Surge voltage test setpoint 4.8 kV Result of power-frequency withstand voltage test Test passed Power frequency withstand voltage setpoint 1.89 kV Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed Result of tight fit on support Test passed Setpoint 5N Result of voltage-drop test Test passed Requirements, voltage drop ≤ 4.8 mV Result of temperature-rise test Test passed Short circuit stability result Test passed Conductor cross section short circuit testing 4 mm² Short-time current 300 A Conductor cross section short circuit testing 4 mm² Short-time current 500 A Conductor cross section short circuit testing 4 mm² Short-time current 150 A Result of thermal test Test passed Proof of thermal characteristics (needle flame) effective duration 30 s Oscillation, broadband noise test result Test passed Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03 Test spectrum Service life test category 2, bogie mounted Test frequency f1 = 5 Hz to f2 = 250 Hz ASD level 6.12 (m/s ) /Hz Acceleration 3.12 g 2 2 03/08/2017   Page 2 / 6 https://www.phoenixcontact.com/us/products/3969928 Test terminal strip - RSCWE 6-3/14 - 3969928 Technical data General Test duration per axis 5h Test directions X-, Y- and Z-axis Shock test result Test passed Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03 Shock form Half-sine Acceleration 30g Shock duration 18 ms Number of shocks per direction 3 Test directions X-, Y- and Z-axis (pos. and neg.) Relative insulation material temperature index (Elec., UL 746 B) 130 °C Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C Static insulating material application in cold -60 °C Behavior in fire for rail vehicles (DIN 5510-2) Test passed Flame test method (DIN EN 60695-11-10) V0 Oxygen index (DIN EN ISO 4589-2) >32 % NF F16-101, NF F10-102 Class I 2 NF F16-101, NF F10-102 Class F 2 Surface flammability NFPA 130 (ASTM E 162) passed Specific optical density of smoke NFPA 130 (ASTM E 662) passed Smoke gas toxicity NFPA 130 (SMP 800C) passed Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3 Dimensions Width 146.7 mm Length 81 mm Height 70.1 mm Plate thickness 1 mm ... 4 mm Pitch 8.2 mm Connection data Connection method Ring cable lug Connection in acc. with standard IEC 60947-7-1 Conductor cross section flexible min. 0.5 mm² Conductor cross section flexible max. 10 mm² 03/08/2017   Page 3 / 6 https://www.phoenixcontact.com/us/products/3969928 Test terminal strip - RSCWE 6-3/14 - 3969928 Technical data Connection data Min. AWG conductor cross section, flexible 24 Max. AWG conductor cross section, flexible 8 2 conductors with same cross section, solid min. 0.5 mm² 2 conductors with same cross section, solid max. 6 mm² 2 conductors with same cross section, stranded min. 0.5 mm² 2 conductors with same cross section, stranded max. 6 mm² Cable lug connection according to standard DIN 46234 Min. cross section for cable lug connection 0.5 mm² Max. cross section for cable lug connection 10 mm² Hole diameter, min. 4.3 mm Cable lug width, max. 8 mm Bolt diameter 4.1 mm Cable lug connection according to standard DIN 46237 Min. cross section for cable lug connection 0.5 mm² Max. cross section for cable lug connection 10 mm² Hole diameter, min. 4.3 mm Cable lug width, max. 8 mm Bolt diameter 4.1 mm Stripping length 12 mm Internal cylindrical gage A5 Screw thread No 8 UNC Tightening torque, min 1.5 Nm Tightening torque max 1.8 Nm Assembly Mounting type Wall mounting Plate thickness 1 mm ... 4 mm Min. tightening torque of the mounting screw: 0.8 Nm Max. tightening torque of the mounting screw: 1 Nm Standards and Regulations Connection in acc. with standard IEC 60947-7-1 Flammability rating according to UL 94 V0 Environmental Product Compliance China RoHS Environmentally friendly use period: unlimited = EFUP-e No hazardous substances above threshold values 03/08/2017   Page 4 / 6 https://www.phoenixcontact.com/us/products/3969928 Test terminal strip - RSCWE 6-3/14 - 3969928 Approvals Approvals Approvals CSA / UL Recognized / cUL Recognized / cULus Recognized Ex Approvals Approval details CSA    http://www.csagroup.org/services/testingand-certification/certified-product-listing/   B C mm²/AWG/kcmil 20-8 20-8 Nominal current IN 31 A 31 A Nominal voltage UN 600 V 600 V UL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm   B C mm²/AWG/kcmil 20-8 20-8 Nominal current IN 31 A 31 A Nominal voltage UN 600 V 600 V cUL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm   B C mm²/AWG/kcmil 20-8 20-8 Nominal current IN 31 A 31 A Nominal voltage UN 600 V 600 V cULus Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  13631  FILE E 60425  FILE E 60425   03/08/2017   Page 5 / 6 https://www.phoenixcontact.com/us/products/3969928 Phoenix Contact 2017 © - all rights reserved http://www.phoenixcontact.com 03/08/2017   Page 6 / 6
3969928 价格&库存

很抱歉,暂时无法提供与“3969928”相匹配的价格&库存,您可以联系我们找货

免费人工找货