https://www.phoenixcontact.com/us/products/2901366
Measuring instrument - EEM-MA600 - 2901366
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Energy measurement device to measure electrical parameters in low voltage installations up to 700 V, acquisition
of individual harmonic oscillations - can be extended with communication and special functional modules
Product Features
Can be extended with special function and communication modules
Remote access via web server, integrated in Ethernet communication module
Acquisition of individual harmonics up to 63rd harmonic
Trend calculation for real and reactive power
Key commercial data
Packing unit
1 pc
Weight per Piece (excluding packing)
840.0 GRM
Custom tariff number
90303100
Country of origin
Tunisia
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
96 mm
Height
96 mm
Depth
82 mm
Installation depth with extension module
80 mm
Installation depth without extension module
60 mm
Ambient conditions
10/10/2014 Page 1 / 7
https://www.phoenixcontact.com/us/products/2901366
Measuring instrument - EEM-MA600 - 2901366
Technical data
Ambient conditions
Degree of protection
IP52 (front), IP30 (back)
Ambient temperature (operation)
-10 °C ... 55 °C (14 °F to 131 °F)
Ambient temperature (storage/transport)
-20 °C ... 85 °C (-4 °F ... 185 °F)
Max. permissible relative humidity (operation)
≤ 95 %
Max. salt spray content
≤ 2.5 %
Altitude
≤ 2000 m
Ambient temperature (operation)
0 °C ... 40 °C
Max. permissible relative humidity (operation)
80 % (up to 31°C)
50 % (at 40 °C)
Input data
Measuring principle
True r.m.s. value measurement
Acquisition of harmonics
up to 63rd harmonic
Measured value
AC sine (50/60 Hz)
Input name
Voltage measuring input V1, V2, V3
Input voltage range
18 V AC ... 700 V AC (Phase/Phase)
11 V AC ... 404 V AC (Phase/neutral conductor)
Input voltage
500 kV AC (Primary, via external voltage transducers)
Secondary, 60, 100, 110, 115, 120, 173, 190 V AC
Precision
0.2 %
Input current range
Via external transformers
Input current
9999 A (primary)
1 A and 5 A, secondary
Current measuring range
0 kA ... 11 kA
Overload capacity
6 A (Permanent)
Response threshold from measuring range nominal value
10 mA
Precision
0.2 %
Current overload
10 x IN for 1 s
Messbereich_Leistung
0 MW ... 8000 MW
0 Mvar ... 8000 Mvar
0 MVA ... 8000 MVA
Precision
0.5 %
Active energy (IEC 62053-22)
Class 0.5S
Reactive power (IEC 62053-23)
Class 2
Voltage input signal
Via extension module
Output data
Output description
Via extension module
10/10/2014 Page 2 / 7
https://www.phoenixcontact.com/us/products/2901366
Measuring instrument - EEM-MA600 - 2901366
Technical data
Interfaces
Designation
Via extension module
General
Display
LCD display, backlighting
Measuring rate
approximately
Supply voltage range
110 V AC ... 400 V AC ±10 %
Nominal power consumption
10 VA
Power consumption
20 VA (With maximum number of extension modules)
Mains type
3-phase (3 or 4-wire), 2-phase (2-wire), and single-phase (1-wire)
Color
black
Conformance
CE-compliant
Rated insulation voltage at mains voltage < 300 V AC (L/N)
III
Rated insulation voltage at mains voltage > 300 V AC - 600 V AC (L/N)
II
Test voltage
3.5 kV AC (50 Hz, 1 min.)
Connection data
Conductor cross section stranded min.
0.5 mm²
Conductor cross section stranded max.
2.5 mm²
Conductor cross section solid min.
0.5 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section AWG/kcmil min.
20
Conductor cross section AWG/kcmil max
14
Connection method
COMBICON plug-in screw terminal block
Stripping length
6 mm
Tightening torque
0.4 Nm
Note
Voltage and other connections
Conductor cross section stranded min.
0.5 mm²
Conductor cross section stranded max.
6 mm²
Conductor cross section solid min.
0.5 mm²
Conductor cross section solid max.
6 mm²
Conductor cross section AWG/kcmil min.
20
Conductor cross section AWG/kcmil max
8
Connection method
Screw connection
Stripping length
7 mm
Note
Current connection
UL data
Nominal supply voltage range
110 V AC ... 240 V AC ±10 %
120 V DC ... 250 V DC ±10 %
10/10/2014 Page 3 / 7
https://www.phoenixcontact.com/us/products/2901366
Measuring instrument - EEM-MA600 - 2901366
Technical data
UL data
Power consumption
10 VA
Operating mode
Indoor use
Surge voltages
Surge voltages according to installation classes
Surge voltage category
I, II, III
Surge voltage category of the supply
Min. II
Classifications
eCl@ss
eCl@ss 4.0
27210902
eCl@ss 4.1
27210902
eCl@ss 5.0
27210902
eCl@ss 5.1
27210902
eCl@ss 6.0
27371890
eCl@ss 7.0
27142333
eCl@ss 8.0
27142333
ETIM
ETIM 3.0
EC001505
ETIM 4.0
EC000705
ETIM 5.0
EC000705
UNSPSC
UNSPSC 6.01
30211916
UNSPSC 7.0901
39121535
UNSPSC 11
39121535
UNSPSC 12.01
39121535
UNSPSC 13.2
39121535
Approvals
Approvals
Approvals
UL Listed / cUL Listed / cULus Listed
Ex Approvals
10/10/2014 Page 4 / 7
https://www.phoenixcontact.com/us/products/2901366
Measuring instrument - EEM-MA600 - 2901366
Approvals
Approvals submitted
Approval details
UL Listed
cUL Listed
cULus Listed
Accessories
Accessories
Communication module
Communication module - EEM-RS485-MA600 - 2901367
RS-485 JBUS/MODBUS communication module for EEM-MA600
Communication module - EEM-PB-MA600 - 2901368
PROFIBUS (1.5 Mbps) communication module for EEM-MA600
10/10/2014 Page 5 / 7
https://www.phoenixcontact.com/us/products/2901366
Measuring instrument - EEM-MA600 - 2901366
Accessories
Communication module - EEM-PB 12-MA600 - 2901418
PROFIBUS (12 Mbps) communication module for EEM-MA600
Communication module - EEM-ETH-MA600 - 2901373
Ethernet communication module for EEM-MA600
Communication module - EEM-ETH-RS485-MA600 - 2901374
Gateway RS-485/Ethernet communication module for EEM-MA600
Extension module
Extension module - EEM-IMP-MA600 - 2904313
Pulse output module for EEM-MA600
Function module
Special function module - EEM-MEMO-MA600 - 2901370
Storage module for intermediate storage of values (512 kB) for EEM-MA600
10/10/2014 Page 6 / 7
https://www.phoenixcontact.com/us/products/2901366
Measuring instrument - EEM-MA600 - 2901366
Accessories
Special function module - EEM-2DIO-MA600 - 2901371
Special functional module with two digital inputs and outputs for EEM-MA600
Special function module - EEM-2AO-MA600 - 2901475
Special functional module with two analog outputs (0–20/4-20mA) for EEM-MA600
Mounting material
DIN rail adapter - EEM-MKT-DRA - 2902078
DIN rail adapter for EEM-MA600 and EEM-MA400 energy meters
Phoenix Contact 2014 © - all rights reserved
http://www.phoenixcontact.com
10/10/2014 Page 7 / 7